PANDUIT CJUDCAPBU-X Angled Wire Cap Instruction Manual
- June 13, 2024
- PANDUIT
Table of Contents
45° Up/Down UTP TG Modular Jacks & Wire Caps
Part Numbers: CJUDCAPBU-X, CJUDCAPIW-X, CJUD6X88TG**
INSTALLATION INSTRUCTIONS
- Category 6A (CJUDCAPBU-X)
- Category 6 (CJUDCAPIW-X)
- 45° Up/Down Wire Cap
Compatible Jack Modules with Angled Wire Caps
- 45° ANGLED JACK CJUD6X88TG**
- STANDARD CJ%%88TG
- SPRING SHUTTERED CJH%%88TG*
- KEYED CJK%%88TG
- KEYED CJK%%88TG
Understanding the Label
IMPORTANT! : Determine the desired direction of cable before wiring the cap. The cap, in relation to the jack, must be kept consistent throughout the entire termination.
Up Orientation
IMPORTANT!:
Be sure that strain relief is fully retracted before inserting cable
Down Orientation
IMPORTANT!:
Be sure that strain relief is fully retracted before inserting cable
REMOVAL STEPS
Notes
- For specified performance, follow TIA/EIA 568-C installation guidelines.
- Jack Modules can terminate 22-26 AWG solid data cable with 0.062″ (1.57mm) maximum insulated conductor outside diameter.
- Jack Modules may be re-terminated at least 20 times.
- For technical and performance information, consult Panduit Technical Support
As with all Wiring Accessories, the following statements apply:
- . Never install communications wiring during a lightning storm.
- Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.
- Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
- Use caution when installing or modifying communication wiring.
For Instructions in Local Languages and Technical Support: www.panduit.com
E-mail: techsupport@panduit.com
Phone: 866-405-6654
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>