TRANE 4WCA4036C1000A RunTru Heat Pump Package Unit User Manual
- June 13, 2024
- Trane
Table of Contents
TRANE 4WCA4036C1000A RunTru Heat Pump Package Unit User Manual
Product Specifications
MODEL | 4WCA4036C1000A |
---|---|
RATED Volts/PH/Hz | 208–230/1/60 |
Performance Cooling BTUH (a) | 34200 |
Indoor Airflow (CFM) | 1105 |
Power Input (KW) | 3.77 |
EER2/SEER2 (BTU/Watt-Hr.) (b) | 10.6/13.4 |
Sound Power Rating [dB(A)] (c) | 79.3 |
PERFORMANCE HEATING | |
(High Temp.) BTUH | 30200 |
Power Input (KW) | 2.53 |
(Low Temp.) BTUH | 18000 |
Power Input (KW) | 2.2 |
HSPF2 (BTUH/Watt-Hr) | 6.7 |
POWER CONN. — V/Ph/Hz | 208/230/1/60 |
Min. Brch. Cir. Ampacity (d) | 25 |
Fuse Size — Max. (amps) | 35 |
Fuse Size — Recmd. (amps) | 35 |
COMPRESSOR | SCROLL |
VOLTS/PH/HZ | 208/230/1/60 |
R.L. Amps — L.R. Amps | 14.1/87.4 |
OUTDOOR COIL — TYPE | PLATE FIN |
Rows/F.P.I | 1/22 |
Face Area (sq. ft.) | 13.2 |
Tube Size (in.) | 5/16 |
Refrigerant Control | EXPANSION VALVE |
INDOOR COIL — TYPE | PLATE FIN |
Rows/F.P.I | 3/16 |
Face Area (sq. ft.) | 4.56 |
Tube Size (in.) | 5/16 |
Refrigeration Control | EXPANSION VALVE |
Drain Conn. Size (in.) | 3/4 MALE NPT |
OUTDOOR FAN — TYPE | PROPELLER |
DIA. (IN.) | 23 |
--- | --- |
DRIVE/NO. SPEEDS | DIRECT / 1 |
CFM @ 0.0 in. w.g. (e) | 3540 |
Motor — HP/R.P.M | 1/5 / 825 |
Volts/Ph/Hz | 200/230 / 1 / 60 |
F.L. Amps/L.R Amps | 1.10/2.51 |
INDOOR FAN — TYPE | CENTRIFUGAL |
Dia. x Width (in.) | 11 X 8 |
Drive/No. Speeds | DIRECT / 3 |
CFM @ 0.0 in. w.g. (f) | SEE FAN PERFORMANCE TABLE |
Motor — HP/R.P.M. | 3/4 / VARIABLE |
Volts/Ph/Hz | 208–230/1/60 |
F.L. Amps | 6.3 |
FILTER / FURNISHED | NO |
Type Recommended | THROWAWAY |
Recmd. Face Area (sq. ft) (g) | 4.0 |
REFRIGERANT | R-410A |
Charge (lbs.) | 4.88 |
CHARGING SPECIFICATIONS | |
Subcooling | 14˚ |
DIMENSIONS | H X W X L |
Crated (in.) | 40 7/8 x 36 3/8 x 61 1/8 |
WEIGHT | |
Shipping (lbs.) / Net (lbs.) | 475 |
(a) Rated in accordance with AHRI Standard 210/240.
(b) Rated in accordance with D.O.E. test procedure.
(c) Sound Power values are not adjusted for AHRI 270–95 tonal
corrections.
(d) Calculated in accordance with currently prevailing Nat’l Electrical
Code.
(e) Standard Air — Dry Coil — Outdoor.
( f) Standard Air — Dry Coil — Indoor
(g) Filters must be installed in return air stream. Square footages
listed are based on 300 f.p.m. face velocity. If permanent filters are used
size per manufacturer’s recommendation with a clean resistance of 0.05” W.C
Outline Drawings
Figure 1. 2 – 5 Tons
TOP SIDE
FRONT SIDE
BOTTOM SIDE
MODEL| HEIGHT MM/IN .| | | | |
---|---|---|---|---|---|---
A| W1| W2| W3| W4| NET WEIGHT/LBS
4WCA4024C| 918.8 [36-5/32]| 383.9 [15 1/8]| 460.1 [18 1/18]| 568.8 [22 13/32]|
636.1 [25 1/32]| 410
4WCA4030C| 918.8 [36-5/32]| 383.9 [15 1/8]| 460.1 [18 1/18]| 568.8 [22 13/32]|
636.1 [25 1/32]| 410
4WCA4036C| 918.8 [36-5/32]| 383.9 [15 1/8]| 460.1 [18 1/18]| 568.8 [22 13/32]|
636.1 [25 1/32]| 430
4WCA4042C| 918.8 [36-5/32]| 383.9 [15 1/8]| 460.1 [18 1/18]| 568.8 [22 13/32]|
636.1 [25 1/32]| 440
4WCA4048C| 1045.8 [41-5/32]| 460.1 [18 1/8]| 510.9 [20 1/8]| 645.0 [25 13/32]|
712.3 [28 1/32]| 460
4WCA4060C| 1045.8 [41-5/32]| 460.1 [18 1/8]| 510.9 [20 1/8]| 645.0 [25 13/32]|
712.3 [28 1/32]| 460
Indoor Fan Performance (230v)
Table 1. Heater Table
Heater | Minimum Heater Airflow CFM |
---|---|
4WCA4036C1000A | |
BAYHTR1V05LUGAA | 1000 |
BAYHTR1H08LUGAA | 1000 |
BAYHTR1H10LUGAA | 1100 |
BAYHTR1H15BRKAA | 1400 |
Table 2. Airflow Table
4WCA4036C| ESP| 0.1| 0.2| 0.3| 0.4| 0.5|
0.6| 0.7| 0.8| 0.9| 1
---|---|---|---|---|---|---|---|---|---|---|---
**Low| CFM| 1369| 1278| 1178| 1078| 977| | | | |
WATTS| 202| 210| 220| 230| 242| | | | |
****Medium| CFM| | | 1334| 1288| 1241| 1193| 1147| 1103| 1050|
WATTS| | | 322| 332| 343| 353| 364| 374| 384|
****High**| CFM| | | | | | | | | 1392| 1284
WATTS| | | | | | | | | 686| 708
Note: Airflow must not exceed 1350 CFM due to condensate blowoff.
Full Perimeter Roof Mounting Curb
Figure 3. 2.0 — 5.0 Ton Models
BAYCURB060A Full Perimeter Roof Mounting Curb
The drawings on this page are prepared by the manufacturer in order to
provide detail regarding job layout only. These drawings are not intended tobe
used as a basis to construct, build or modify theitems depicted in the
drawings. The manufacturer is not responsible for the unauthorized use of
these drawings and expressly disclaims any liability for damages resulting
from such unauthorized use.
SERVICE CLEARANCE DIMENSIONS
A| B| C| D
12| 42| 42| 36
Supplementary Electric Heaters
Table 3. HP Models Only
UNIT MODEL| ELECTRIC HEATER MODEL| RATED VOLT- AGE| PHASE| AMPS| HEATER
CAPACITY| NO. OFSTAGES| KW/STAGE| MCA| MAX. OVER CURRENT PROTEC- TION
DEVICE
---|---|---|---|---|---|---|---|---|---
KW| BTUH| 1| 2
4WCA40241000A4WCA40301000A4WCA40361000A4WCA40421000A4WCA40481000A4WCA40601000A|
BAYHTR1V05LUGA| 208/240| 1| 17/20| 3.6/4.8| 12300/16400| 1| 3.6/4.8| —|
22/25| 25/25
BAYHTR1H08LUGA| 208/240| 1| 28/32| 5.76/7.68| 19700/26200| 1| 5.76/7.68| —|
35/40| 35/40
BAYHTR1H10LUGA| 208/240| 1| 35/40| 7.2/9.6| 24600/32800| 1| 7.2/9.6| —|
43/50| 45/50
4WCA40361000A4WCA40421000A4WCA40481000A4WCA40601000A| BAYHTR1H15BRKA|
208/240| 1| 52/60| 10.8/14.4| 36900/49100| 2| 7.2/9.6| 3.6/4.8| 65/75|
70/80
4WCA40601000A| BAYHTR1H20BRKA| 208/240| 1| 69/80| 14.4/19.2| 49100/65500| 2|
7.2/9.6| 7.2/9.6| 87/100| 90/100
- Any power supply and circuits must be wired and protected in accordance with local electrical codes.
- The values listed in the above table are for the electric heater only.
- Field wiring must be rated at least 75° C.
- indicates an alpha character ALL VALUES ARE FOR THE ELECTRIC HEATER ONLY
Table 4. BAYSPEK – Single Power Entry Kit
SINGLE CIRCUIT POWER AMPACITY AND OVER CURRENT PROTECTION
UNIT MODEL| SINGLE POWER ENTRY KIT| HEATER MODEL| MIN CKT AMP| MAX OVER-
CURRENT DEVICE
**** 4WCA4036C| **** BAYSPEK070| BAYHTR1H08| 65| 70
BAYHTR1H10| 75| 80
BAYSPEK071| BAYHTR1H15| 100| 100
BAYSPEK072| BAYHTR1V05| 50| 50
Mechanical Specifications
General
The units shall be horizontal airflow as shipped and convertible to downflow.
All units shall be factory assembled, piped, internally wired and fully
charged with refrigerant. Units shall be certified to UL Standard 1995. All
units shall be factory run tested to check cooling operation, fan and blower
rotation and control or TXV sequence. Units shall be designed to operate at
ambient temperatures between 115°F and 55°F in cooling as manufactured.
Cooling performance shall be rated in accordance with AHRI standards.
Unit Casing
All components shall be mounted in a weatherresistant steel cabinet with an
enamel finish. Accesspanels shall be provided for unit controls and indoor
coil and fans. Indoor air section compartment shall be completely insulated
with fireproof, permanent, odorless fiber material. Knockouts shall be
provided for utility and control connections. Drain connections shall be
provided to accommodate indoor water runoff
Compressor (2 and 2 1/2 Ton Models)
The compressor shall be hermetically sealed, high efficiency rotary
compressors. Internal overcurrent and over temperature protection, internal
pressure relief shall be standard. Other features include centrifugal oil
pump, low vibration and noise.
Compressor (3–5 Ton Models)
The compressor shall be hermetically sealed, high efficiency scroll
compressors. Internal overcurrent and over temperature protection, internal
pressure relief shall be standard. Other features include centrifugal oil
pump, low vibration and noise.
Refrigeration System
All units shall have refrigerant control. Service pressure tap ports and a
refrigerant line filter shall be standard. Evaporator Coil Internally enhanced
3/8” OD seamless copper tubing mechanically bonded to aluminum fins, factory
pressure and leak tested at 480 – 650 psig. All units have TXV to control
refrigerant flow.
Condenser Coil
All aluminum micro channel, extruded tubes, mechanically bonded to aluminum
fins, and factory pressure and leak tested at 480 – 650 psig.
Indoor Air Fan
Constant Torgue, forward-curved, centrifugal wheel in a Metallic Blower
housing. Motor shall have thermal overload protection and permanently
lubricated motor bearings. Motor/blower assembly isolated from unit with
rubber mounts.
Outdoor Fan
One direct-drive, statically and dynamically balancedpropeller fan shall be
used in a draw-through vertical discharge configuration. Permanently
lubricated weather proof motor shall have built-in thermal overload
protection.
System Controls
System controls include condenser fan, evaporator fan and compressor
contactors.
Accessories Roof Curb
The roof curb shall be designed to mate with the unit and provide support and
complete weathertight installation when properly installed. Adhesive back
polyurethane sealing strips shall be provided to ensure an airtight seal
between supply and return openings of the curb and unit. The roof curb design
allows field fabricated ductwork to be connected directly to the curb. Curb
ships knocked down for field assembly, and includes factory installed wood
nailer strips.
Electric Heaters
Each heater assembly shall include power supply fusing if over 48 amps,
automatic resetting limit switches and heat limiters for thermal protection.
Heaters shall be provided with polarized plugs for quick connection to unit
low voltage wiring. Electric heat modules shall be UL listed.
Single Source Power Entry
This accessory when used with electric heat accessory shall allow single
source power connection to unit and heater combination. Single source power
entry kits shall have specific matching heater(s). Kit shall include high
voltage terminal blocks, fuse blocks and fuses, cut-to-length interconnecting
wiring, and junction box (if required) to provide power sources with fuse
protection as required for both the unit and accessory heater. Kit components
shall install within the heater cabinet in the heater access section. Single
source branch power circuit shall be protected and wired in accordance with
local codes.
Start Kit
Extra compressor starting capacity for single phase equipment.
Control Options Standard Indoor Thermostats
Two stage heating/cooling or one stage heating/ cooling thermostats shall be
available in either manual or automatic changeover.
Programmable Electronic Night Setting Thermostat
Programmable electronic thermostat shall provide heating setback and cooling
setup with 7–day programming capability. 1H/1C or 2H/2C models available.
About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient indoor
environments for residential applications. For more information, please visit
www.trane.com or
www.americanstandardair.com
The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org.
The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.
4WCA4036C-SUB-1A-EN 28 Oct 2022 Supersedes (New)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>