Gaabor GVCW-M16Y02 Vacuum Cleaner Instruction Manual

June 13, 2024
Gaabor

Gaabor GVCW-M16Y02 Vacuum Cleaner

Gaabor-GVCW-M16Y02-Vacuum-Cleaner-product

Please read this manual carefully before using the product and keep it properly for future reference.

Safety Notice for Using

Please carefully read and follow the “Safety Notice for Using to ensure your safety and prevent property loss.

  1. Please read this manual carefully before use.
  2. Please check whether the voltage required by this product is consistent with the voltage in your home before use.
  3. Do not use this product outside the specified scope.
  4. Please use according to the design function of the vacuum cleaner.
  5. It is not recommended to use this product by the following people (including children): those with physical and mental disabilities or those lacking relevant operating experience and knowledge, unless they are supervised and guided by the person responsible for their safety.
  6. This product is a dry vacuum cleaner. Please do not use it to absorb detergent, kerosene, glass, needles, water wet dust, sewage, matches, etc.
  7. Please keep the vacuum cleaner away from fire sources and other high-temperature places.
  8. Do not use the vacuum cleaner to absorb water and other liquids, and do not flush the whole vacuum cleaner with water.
  9. When you need cleaning and maintenance or do not use the vacuum cleaner, please unplug the power plug and do not pull the power cord.
  10. Please do not block the suction inlet when using the vacuum cleaner to avoid motor damage due to overload.
  11. Please install the dust filter frame when using the vacuum cleaner to prevent dust from entering the motor.
  12. Please do not use the vacuum cleaner to absorb cement, gypsum powder, wall powder and other small particles, so as to avoid clogging of the vacuum cleaner filter or filter screen, resulting in motor burning and other failures.
  13. Please use a wet cloth stained with water or neutral detergent when cleaning the vacuum cleaner. Do not use gasoline, bananas, etc. to avoid cracking or fading of the shell.
  14. Please read the instruction manual and diagram carefully before using this product.
  15. Please do not let children play with this product.
  16. When the power cord is damaged, it must be replaced by the manufacturer, its maintenance department or similar professionals to avoid danger.
  17. Do not use high-power electrical appliances on the same circuit to prevent danger caused by overload of the circuit.
  18. Do not use the product in case of any damage.
  19. Please keep this manual properly.

Technical Parameters

  • Model
    • GVCW-M16Y02
  • Rated voltage
    • 220-240V
  • Rated frequency
    • 50/60Hz
  • Rated power
    • 650W
  • Rated capacity
    • 1.2L

Product Parts

Gaabor-GVCW-M16Y02-Vacuum-Cleaner-fig-1

  1. Host
  2. Connector
  3. Connecting pipe
  4. Floor brush
  5. Long oblate brush

Specifications and components of this product are subject to change without notice.

Installation instructions

Note: Do not plug in power during installation Vertical type (with extension pipe)

Gaabor-GVCW-M16Y02-Vacuum-Cleaner-fig-2

  1. Please insert the connector (1) into the air inlet of the host, then insert the suction head of the floorbrush (3) into the extension pipe (2), and then insert the suction of the floor brush (3) into the extension pipe (2), as shown in Fig. 1

Handheld type (without extension pipe)

Gaabor-GVCW-M16Y02-Vacuum-Cleaner-fig-3

  1. Grasp the holder of the vacuum cleaner by your hand, insert the connector (1) into the suction of the host, and then insert the flat suction (2) into the connector (1), as shown in Fig. 2
  2. Plug in the power socket and press the switch to carry out palm cleaning;
  • Please turn off the power switch after use, pull the plug out of the socket, and then wrap the power cord for storage.
  • Plug in the power socket and press the switch to carry out palm cleaning.
  • Note: The floor brush is applicable to a wide range of places under tables and cabinets, and the two in one flat suction/round brush is applicable to a small range of narrow seams such as sofas, tables and chairs, curtains, etc.

Cleaning and maintenance

Note: Please pull out the power plug before cleaning and maintenance

Use and maintenance

Clean the filter screen assembly (please unplug the power supply before cleaning)

Please clean the filter screen immediately when the suction is weakened due to dust accumulation on the dust collector and filter screen assembly

  1. Remove the dust cup: separate the dust cup according to the steps in Fig. 3.Gaabor-GVCW-M16Y02-Vacuum-Cleaner-fig-4
  2. Clean the dust cup: take the filter cartridge out of the dust cup, just pat the dust accumulated on it gently, and then install it back into the dust cup (as shown in Fig. 4). Since the filter screen will naturally wear, please replace it regularly, please replace it with a new filter screen regularly, and contact the after-sales service department to purchase it before installing it back into use.
  3. Please clean the dust/garbage in the dust cup after each use to avoid accumulation of dust or bacteria. As shown in Fig. (5).
  4. Clean the dust cup and filter cartridge thoroughly after disassembling the dust cup (it can be washed with water but can only be used after being dried), as shown in Fig. 5.

Use and maintenance

Attention

  • Please confirm that the vacuum cleaner is not plugged in before maintenance and parts handling.
  • Please clean the vacuum cleaner frequently to achieve the best vacuum effect.
  • Please contact the distributor to purchase a new filter element to replace one that is too worn or damaged.
  • Please contact the distributor on the package for any questions about the product.
  • Clean the pipe of the dust collector: regular cleaning of the dust collector can increase the dust collection efficiency of the vacuum cleaner and prevent overheating and loss of the vacuum cleaner.
  • Please clean the dust collector immediately after the use of the vacuum cleaner to keep the best suction force for the next use.
  • Do not put the wet dust collector into the vacuum cleaner for use to avoid damage to the product.

Packing list

Gaabor-GVCW-M16Y02-Vacuum-Cleaner-fig-6

Contact

  • Manufacturer: UNITED GAIN LIMITED
  • Entrusting party: HANGZHOU GLOBAL JET ECOMMERCE CO .,LTD
  • Address: 1-1407, 501 2nd Avenue, QianTang New Area, Hangzhou.P.R.China
  • Telephone: 0571-88269187
  • Origin: Made in China