Delfield 549-CR 500 Series Refrigerated Display Case Instruction Manual
- June 13, 2024
- DELFIELD
Table of Contents
549-CR 500 Series Refrigerated Display Case
Product Information
The 500 Series is a line of display cases manufactured by
Delfield. This Service and Installation Manual provides detailed
instructions for the installation, operation, care, and cleaning of
the equipment. The manual also includes specifications and wiring
diagrams for different models.
Specifications
Model Number | Delfield Part # | Volts/Hertz Phase | Amps (includes lights & fan) |
---|---|---|---|
537-CD | 078-5371 | 115/60/1 | 5.0 |
549-CD | 078-5491 | 115/60/1 | 5.0 |
561-CD | 078-5611 | 115/60/1 | 5.0 |
573-CD | 078-5731 | 115/60/1 | 5.0 |
549-CH | 078-5494 | 120, 208-240V/60/1 | 19.0/21.0 |
561-CH | 078-5614 | 120, 208-240V/60/1 | 24.0/27.0 |
573-CH | 078-5734 | 120, 208-240V/60/1 | 24.0/27.0 |
Product Usage Instructions
Please follow the instructions below for receiving, inspecting,
and uncrating the equipment:
Receiving and Inspecting the Equipment
-
Visually inspect the exterior of the package and skid or
container. Note any damage and report it to the delivering carrier
immediately. -
If damaged, open and inspect the contents with the
carrier. -
If there is concealed damage to the equipment upon opening,
notify the carrier verbally and in written form. -
Request an inspection by the shipping company within 10 days
from receipt of the equipment if there is concealed damage. -
Check the lower portion of the unit to ensure adjustable feet
are not bent. -
Open the compressor compartment housing and visually inspect
the refrigeration package. Ensure lines are secure and the base is
intact. -
Freight carriers can supply the necessary damage forms upon
request. -
Retain all crating material until an inspection has been made
or waived.
Uncrating the Equipment
-
Cut and remove the banding from around the crate.
-
Remove the front of the crate material using appropriate
tools. -
If the unit is on legs, remove the top of the crate and lift
the unit off the skid.
For customer service, call 800-733-8829
or 800-773-8821. You
can also fax them at 989-773-3210. More
information can be found
on their website at www.delfield.com.
500 Series
Service and Installation Manual
Please read this manual completely before attempting to install or operate
this equipment! Notify carrier of damage! Inspect all components immediately.
See page 2.
PLEAIMSEPOSRRAETVAAEDNTTBHEIENFSOFEORIRENMSUTASRTEIUOCNTIONS!
April 2010
500 Series Display Cases Service and Installation Manual
CONTENTS
RECEIVING & INSPECTING EQUIPMENT…………………………2 SPECIFICATIONS
…………………………………………………………3 PRESSURE CONTROL SETTINGS …………………………………..5
INSTALLATION……………………………………………………….. 5, 6 OPERATION …………………………………………………………… 5,
6 CARE & CLEANING……………………………………………………..6 WIRING DIAGRAMS
500-CR self-contained refrigerated units …………………..7 500-OR open refrigerated
units ……………………………….7 500-CD dry storage units ……………………………………….8 500-CH curved
heated units ……………………………………8 EXPLODED VIEWS & PARTS LISTS 537-CD
………………………………………………………………..9 549-CD ………………………………………………………………..9 561-CD
………………………………………………………………10 573-CD ………………………………………………………………10 537-CR, CRR
………………………………………………………11 549-CR, CRR ………………………………………………………11 561-CR, CRR
………………………………………………………12 573-CR, CRR ………………………………………………………12 549-CH
………………………………………………………………13 561-CH ………………………………………………………………13 573-CH
………………………………………………………………14 549-OR ………………………………………………………………14 FLUORESCENT LIGHT
ASSEMBLY ……………………………….15 DOOR ASSEMBLY………………………………………………………16 REFRIGERATION
ASSEMBLES……………………………………..17 FOOD WELL ASSEMBLY ……………………………………………..18
REPLACEMENT PARTS LIST ……………………………………….19 STANDARD LABOR
GUIDELINES………………………………….20 STANDARD WARRANTIES…………………………………….. 21-22 NOTES
……………………………………………………………………..23
SERIAL NUMBER LOCATION
The Serial number on all 500 Series units is located on the rear of the unit,
near the ON/OFF switch. Always have the serial number of your unit available
when calling for parts or service. A complete list of authorized Delfield
parts depots can be found at www.delfield.com.
©2010 The Delfield Company. All rights reserved. Reproduction without written
permission is prohibited. “Delfield” is a registered trademark of The Delfield
Company.
RECEIVING AND INSPECTING THE EQUIPMENT
Even though most equipment is shipped crated, care should be taken during
unloading so the equipment is not damaged while being moved into the building.
1. Visually inspect the exterior of the package and skid or container. Any
damage should be noted and reported to the delivering carrier immediately.
2. If damaged, open and inspect the contents with the carrier.
3. In the event that the exterior is not damaged, yet upon opening, there is
concealed damage to the equipment notify the carrier. Notification should be
made verbally as well as in written form.
4. Request an inspection by the shipping company of the damaged equipment.
This should be done within 10 days from receipt of the equipment.
5. Check the lower portion of the unit to be sure adjustable feet are not
bent.
6. Also open the compressor compartment housing and visually inspect the
refrigeration package. Be sure lines are secure and base is still intact.
7. Freight carriers can supply the necessary damage forms upon request.
8. Retain all crating material until an inspection has been made or waived.
Uncrating the Equipment First cut and remove the banding from around the
crate. Remove the front of the crate material, use of some tools will be
required. If the unit is on legs remove the top of the crate as well and lift
the unit off the skid.
2
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
500 SERIES SPECIFICATIONS
500 Series Display Cases Service and Installation Manual
MODEL NUMBER
DELFIELD PART #
VOLTS/HERTZ PHASE
AMPS (includes lights & fan)
Dry Storage Display Cases
537-CD
078-5371
115/60/1
5.0
549-CD
078-5491
115/60/1
5.0
561-CD
078-5611
115/60/1
5.0
573-CD
078-5731
115/60/1
5.0
MODEL NUMBER
DELFIELD PART #
NUMBER OF 12 X 20 WELLS
VOLTS/HERTZ PHASE
AMPS
Heated Display Cases
549-CH
078-5494
561-CH
078-5614
573-CH
078-5734
3
120, 208-240V/60/1
19.0/21.0
4
120, 208-240V/60/1
24.0/27.0
5
120, 208-240V/60/1
30.0/34.0
MODEL NUMBER
DELFIELD PART #
VOLTS/HERTZ
H.P.*
PHASE
AMPS
EVAPORATOR CAPACITY BTU/°TD
CABINET LOAD BTU/HOUR
Remote Refrigerated Display Cases
537-CRR
CONSULT FACTORY
1/2* 115/60/1
5.0
549-CRR
078-5493
1/2* 115/60/1
5.0
561-CRR
078-5613
3/4* 115/60/1
6.0
573-CRR
078-5733
3/4* 115/60/1
6.0
*Recommended horsepower
180
1730
190
2250
190
2770
290
3290
MODEL NUMBER
DELFIELD PART #
VOLTS/HERTZ
H.P.
PHASE
AMPS
CABINET LOAD SYSTEM CAPACITY
BTU/HOUR
BTU/HOUR
REFRIGERATION CHARGE 404A
Self-Contained Refrigerated Display Cases
537-CR
078-5372
1/2
115/60/1
12.0
549-CR
078-5492
1/2
115/60/1
12.0
561-CR
078-5612
3/4
115/60/1
16.0
573-CR
078-5732
3/4
115/60/1
16.0
1730 2250 2770 3290
3258 3316 4919 5387
32 oz. 32 oz. 48 oz. 48 oz.
MODEL NUMBER
DELFIELD PART#
VOLTS/HERTZ
H.P.
PHASE
AMPS
CABINET LOAD SYSTEM CAPACITY
BTU/HOUR
BTU/HOUR
REFRIGERATION CHARGE 404A
Open Front Refrigerated Display Cases
549-OR
078-5495
1/2
115/60/1
12.0
2030
3354
32 oz.
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
3
500 Series Display Cases Service and Installation Manual
INSTALLATION: 500 CD, CR, CRR & OR
Location
To meet NSF standards, all units must be sealed to the floor.
Be sure the location chosen has a floor strong enough to support the total
weight of the cabinet and contents. Contents fully loaded in this product line
can weigh as much as 1500 lbs. Reinforce the floor as necessary to provide for
maximum loading. For the most efficient refrigeration, be sure to provide good
air circulation inside and out. Do not pack the refrigerator so full that air
cannot circulate. Be sure that the exterior of the unit has access to ample
air. Avoid hot corners and locations near stoves and ovens.
Leveling
To level unit, simply lower the four adjustable rubber feet located under the
unit to the floor and adjust until unit is level. A level cabinet will perform
better because the drain will empty properly, the doors will line up with the
frames correctly and the cabinet will not be subject to undue strain.
Plumbing
Self-contained models are standard with a condensate evaporator. If the evaporator fails, the unit’s drain must have an outlet to an appropriate drainage area or container.
CAUTION
Moisture collecting from improper drainage can create a slippery surface on the floor and a hazard to employees. It is the owner’s and operator’s responsibility to provide a container or outlet for drainage.
Electrical connection
Refer to the amperage data on page 3, the serial tag, your local code or the
National Electrical Code to be sure the unit is connected to the proper power
source. A protected circuit of the correct voltage and amperage must be run
for connection of the line cord, or permanent connection to the unit.
Self-contained units have an ON/OFF switch located on the operators side.
Simply turn the switch to ON to begin operation.
The power switch should be turned to OFF and the unit disconnected from the
power source whenever performing service or maintenance functions.
OPERATION: 500 CD, CR, CRR & OR
On self-contained models, after turning the ON/OFF switch to ON, the unit’s
compressor will begin operating. Delfield display cases are designed to
maintain an operational temperature of 36°F to 40°F.
Do not load the storage area in a way that restricts the air flow. Overloading
will result in the loss of temperature. Do not throw items into the storage
area. The interior of the cabinet and the blower coil may be damaged by this
type of neglect, which is not covered under your warranty.
These units use HFC-404A refrigerant, and have a lock-out high pressure limiting device. Under severe overloading conditions, in the event of a condenser fan failure or a plugged or blocked condenser, this device may shut down the refrigeration system. See page 17 for part number information if a replacement is required.
4
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
500 Series Display Cases Service and Installation Manual
CONTROL SETTINGS: 500 CR & OR
Pressure Control The temperature is controlled by an adjustable pressure
control located in the machine compartment. An adjustable control has the word
COLDER near the knob, with an arrow to indicate the adjustment direction.
These controls are field adjustable and do not require a service agent. If you
have any questions, feel free to contact the Delfield Service Department.
The refrigeration systems on self-contained CR & OR models were adjusted at
the factory to maintain between 36°F and 40°F. No adjustment should be
necessary. If adjustment does become needed however, the factory recommended
settings are: Low-pressure settings (CR models): 82 psi cut-in, 47 psi cut-
out, 35 psi differential. Low-pressure settings (OR models): 82 psi cut-in, 40
psi cut-out, 42 psi differential. Operating pressures: High, 170 to 200 psi.
Low, 30 to 37 psi.
In attempting to adjust the pressure control, you can do damage to your unit
by accidentally adjusting the differential. Please make small incremental
adjustments if a temperature adjustment is necessary, please contact the
service department at Delfield
800-733-8829 #1, or your local service
agent. Delfield is not responsible for charges incurred while having the
pressure control adjusted.
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
5
500 Series Display Cases Service and Installation Manual
INSTALLATION: 500 CH
Installation should be done by personnel certified and licensed to install and
maintain electrical appliances.
Location
Be sure the location chosen has a floor strong enough to support the total
weight of the cabinet and contents. Contents fully loaded into this product
line can weigh as much as 1500 lbs. Reinforce the floor as necessary to
provide for maximum loading.
Leveling
A level cabinet looks better and will perform better because the drain pan
will drain properly, the doors will line up with the frames properly, and the
cabinet will not be subject to undue strain.
Electrical connection
Connections must be made in accordance with all applicable local codes and/or
the National Electrical Code. Refer to the wiring diagrams on pages 6 and 7.
OPERATION: 500 CH
NOTE: Intended for DRY OPERATION ONLY.
Before the unit is used the first time for serving, turn the temperature knob
to “10” and heat the well for 20 minutes. Do not be alarmed if smoke appears;
this preheat should burn off any residue or dust on the heating element.
Hot surfaces can cause serious burns. Always wear some type of protective
covering on your hands and arms when removing lids or pans from the unit.
Never place food directly into the well. Always use pans. Always place covers
on pans when not serving to prevent food from drying out and to reduce your
operating cost.
For most efficient operation, keep covered insets empty in each well during
preheating and when the well is not in use.
Dry operation
- Pre-heat the well on “HIGH” for approximately 15 minutes.
STEPS 2) After pre-heating, set the control to your desired serving temperature.
Only 6″ (15.2cm) deep insets should be used with a dry food well. When operated dry, the bottom of the food well will discolor. Refer to cleaning instructions to remove discoloration.
Temperature
Product in pans . . . . . . . . . . . . . . . . . . . . . . 140°F to 160°F
CLEANING: ALL MODELS
Clean the food wells daily. Wash with non-abrasive cleanser and non-abrasive
pad. If necessary, a mild abrasive may be used. Do not use steel wool.
For all stainless steel parts, use mild, non-abrasive soap or detergent and
warm water. This may be followed by an application of stainless steel cleaner
or polish which will eliminate water spotting and fingerprints and will bring
out the finish of the stainless steel.
Do not use a hose or pressure wash on these units. The water will damage the
electrical components.
Cleaning the condenser (refrigerated units)
In order to maintain proper refrigeration, the condenser fins must be cleaned
of dust, dirt and grease every three months. If condenser is totally blocked
after three months increase cleaning frequency. Clean the condenser with a
vacuum cleaner or stiff brush. If extremely dirty, use a commercially
available condenser cleaner.
Cleaning the sliding door assembly
All Delfield 500 Series display cases feature a Pike sliding door assembly.
Regular cleaning of door tracks with mild soap and water will keep them free
of foreign matter insuring many years of use. The glass may be cleaned with a
glass cleaner.
6
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
WIRING: 500 CR
500 Series Display Cases Service and Installation Manual
WIRING: 500 OR
NEUTRAL
NEUTRAL
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
7
500 Series Display Cases Service and Installation Manual
WIRING: 500 CD
WHT
WHT WHT
BLK
WIRING: 500 CH
BLK
P
RED
BLK
P
RED
P
BLK RED
P
WHT
WHT
WHT WHT
WHT WHT
208V
P L1 L2
H1
H2
208V
P L1 L2
H1
H2
208V
P L1 L2
H1
H2
120V
P L1 L2
H1
H2
RED BLK
BLK
WHT
BLK
WHT
BLK
WHT
BLK
WHT
J
BLK RED BLK RED BLK RED BLK WHT
HEATED SHELF
8
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
500 Series Display Cases Service and Installation Manual
REPLACEMENT PARTS LIST FOR 537-CD
9
10 2
4 6
7 3 13 12 6
5 1
DELFIELD KEY QUANTITY PART#
DESCRIPTION
1
1
2
1
11
3
1
4
1
5
2
6
2
7
4
8
2
9
1
10
1
11
1
12
4
13
4
001-3133 001-3134 397-8121 397-8120 001-5285 XMK00127 001-5407 001-5026 397-8137 397-8138 323-7490 932-1095 932-1401
mirror, acrylic, RH, 500-CD mirror, acrylic, LH, 500-CD
holder, adj. shelf, RH holder, adj. shelf, LH diffuser, air 537-CD/CR fixture,
flour. light, 24 remote support, shelf, 537-CD/CR clip, air diffuser, 537-CD
shelf, adjustable, 21″ x 33″ shelf, adjustable, 26″ x 33″ door set, with lock,
537-CD/CR stud, threaded, s/s, 1/4-20 x .75 nut, 1/4-20, locking
Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & door keys #323-3988
14 15 16 8
REPLACEMENT PARTS LIST FOR 549-CD
DELFIELD KEY QUANTITY PART#
DESCRIPTION
1
1
2
1
3
1
4
1
5
2
6
4
7
2
8
2
9
1
10
1
001-3133 001-3134 397-8121 397-8120 XMK00128 001-5235 397-8122 397-8123 323-4697 216-2677
mirror, acrylic, RH, 500-CD mirror, acrylic, LH, 500-CD
holder, adj. shelf, RH holder, adj. shelf, LH fixture, flour. light, 36 remote
shelf support shelf, top
shelf, bottom door assembly, with lock
fan, axial
Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & door keys #323-3988
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
9
500 Series Display Cases Service and Installation Manual
REPLACEMENT PARTS LIST FOR 561-CD
DELFIELD KEY QUANTITY PART#
DESCRIPTION
1
1
2
1
3
1
4
1
5
2
6
4
7
2
8
2
9
1
10
1
11
1
12
1
001-3133 001-3134 397-8121 397-8120 XMK00129 001-5277 397-8122 397-8123 323-4698 216-2677 397-8125 397-8126
mirror, acrylic, RH, 500-CD mirror, acrylic, LH, 500-CD
holder, adj. shelf, RH holder, adj. shelf, LH fixture, flour. light, 48 remote
shelf support shelf, top
shelf, bottom door assembly, PIKE, with lock
fan, axial shelf, top center shelf, bottom center
Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & door keys #323-3988
REPLACEMENT PARTS LIST FOR 573-CD
DELFIELD KEY QUANTITY PART#
DESCRIPTION
1
1
2
1
3
1
4
1
5
2
6
4
7
2
8
2
9
1
10
1
11
1
12
1
001-3133 001-3134 397-8121 397-8120 XMK00130 001-5295 397-8122 397-8123 323-4699 216-2677 397-8127 397-8128
mirror, acrylic, RH, 500-CD mirror, acrylic, LH, 500-CD
holder, adj. shelf, RH holder, adj. shelf, LH fixture, flour. light, 60 remote
shelf support shelf, top
shelf, bottom door assembly, PIKE, with lock
fan, axial shelf, top center shelf, bottom center
Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & Pike door keys #323-3988
10
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
500 Series Display Cases Service and Installation Manual
REPLACEMENT PARTS LIST FOR 537CR/CRR
9
10 2
4 6
7 3 13 12 6
5 1
14 15 16 8
DELFIELD KEY QUANTITY PART#
DESCRIPTION
1
1
2
1
11
3
1
4
1
5
2
6
2
7
4
8
1
9
1
10
1
11
1
12
4
13
4
14
1
15
4
16
4
001-3131 001-3132 397-8121 397-8120 001-5285 XMK00127 001-5407 001-5407 397-8137 397-8138 323-7490 932-1095 932-1401 001-5422 001-5252 932-1238
mirror, acrylic, RH, 500-CR mirror, acrylic, LH, 500-CR
holder, adj. shelf, RH holder, adj. shelf, LH diffuser, air 537-CD/CR fixture,
flour. light, 24 remote support, shelf, 537-CD/CR divider, air flow, 537-CR
shelf, adjustable, 21″ x 33″ shelf, adjustable, 26″ x 33″ door set, with lock,
537-CD/CR stud, threaded, s/s, 1/4-20 x .75 nut, 1/4-20, locking cover, coil,
537-CR clip, holding, coil cover screw, #8 x .75, H/N-P-TR-A
Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & door keys #323-3988
REPLACEMENT PARTS LIST FOR 549-CR/CRR
DELFIELD KEY QUANTITY PART#
DESCRIPTION
1
1
2
1
3
1
4
1
5
2
6
4
7
2
8
2
9
1
001-3133 001-3132 397-8121 397-8120 XMK00128 001-5235 397-8122 397-8123 323-4697
mirror, acrylic, RH mirror, acrylic, LH holder, adj. shelf, RH holder, adj.
shelf, LH fixture, flour. light, 36 remote
shelf support shelf, top
shelf, bottom door assembly, with lock
Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & door keys #323-3988
11 For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
500 Series Display Cases Service and Installation Manual
REPLACEMENT PARTS LIST FOR 561-CR/CRR
DELFIELD KEY QUANTITY PART#
DESCRIPTION
1
1
2
1
3
1
4
1
5
2
6
4
7
2
8
2
9
1
10
1
11
1
001-3133 001-3132 397-8121 397-8120 XMK00129 001-5277 397-8122 397-8123 323-4698 397-8125 397-8126
mirror, acrylic, RH mirror, acrylic, LH holder, adj. shelf, RH holder, adj.
shelf, LH fixture, flour. light, 48 remote
shelf support shelf, top
shelf, bottom door assembly, PIKE, with lock
shelf, top center shelf, bottom center
Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & door keys #323-3988
REPLACEMENT PARTS LIST FOR 573-CR/CRR
DELFIELD KEY QUANTITY PART#
DESCRIPTION
1
1
2
1
3
1
4
1
5
2
6
4
7
2
8
2
9
1
10
1
11
1
001-3133 001-3132 397-8121 397-8120 XMK00130 001-5295 397-8122 397-8123 323-4699 397-8127 397-8128
mirror, acrylic, RH mirror, acrylic, LH holder, adj. shelf, RH holder, adj.
shelf, LH fixture, flour. light, 60 remote
shelf support shelf, top
shelf, bottom door assembly, PIKE, with lock
shelf, top center shelf, bottom center
Please Note: Items not shown on exploded view are listed on page 17. Door locks #323-3986 & door keys #323-3988
12
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
500 Series Display Cases Service and Installation Manual
REPLACEMENT PARTS LIST FOR 549-CH
15
11
13 2 12 16
43 10 43
5 6
7 8 9
KEY
1
2
1
3
4
5
6
7
8
9
14
10
11
12
13
14
15
16
DELFIELD PART#
323-4055 345-5439 219-3959 219-3960 219-3970 XMK00106 219-4212 219-0154
351-6059 105-0183 105-0173 105-0184 105-0174 001-5414 001-5415 001-6855
DESCRIPTION
door set, 49″ curved glass glass, curved, 1″ insulated, 47″ bulb, 25W, Teflon
coated, clear
lamp holder, twin-threaded heater, pad, 115V/90W
warmer, food, 208V, no drain switch, 30A 120/277V
switch, rocker, 20A/125V, 15A/250V thermometer, digital, solar/batt
extrusion, polyethylene, blk, vertical, RH extrusion, polyethylene, blk,
vertical, LH extrusion, polyethylene, blk, curved, RH extrusion, polyethylene,
blk, curved, LH
trim, side, exterior, RH trim, side, exterior, LH trim, front, laminate
REPLACEMENT PARTS LIST FOR 561-CH
15
11 13
2 12 16
43 10 43
5 6
7 8 9
KEY
1
2
1
3
4
5
6
7
8
9
14
10
11
12
13
14
15
16
DELFIELD PART#
323-4068 345-5441 219-3959 219-3960 219-3970 XMK00106 219-4212 219-0154
351-6059 105-0183 105-0173 105-0184 105-0174 001-5414 001-5415 001-6866
DESCRIPTION
door set, 61″ curved glass glass, curved, 1″ insulated, 59″ bulb, 25W, Teflon
coated, clear
lamp holder, twin-threaded heater, pad, 115V/90W
warmer, food, 208V, no drain switch, 30A 120/277V
switch, rocker, 20A/125V, 15A/250V thermometer, digital, solar/batt
extrusion, polyethylene, blk, vertical, RH extrusion, polyethylene, blk,
vertical, LH extrusion, polyethylene, blk, curved, RH extrusion, polyethylene,
blk, curved, LH
trim, side, exterior, RH trim, side, exterior, LH trim, front, laminate
13 For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
500 Series Display Cases Service and Installation Manual
REPLACEMENT PARTS LIST FOR 573-CH
15
11
13 2 12
43
10
43 11
5 6
16 7 8 9
KEY
1
1
2
3
4
5
6
7
14
8
9
10
11
12
13
14
15
16
DELFIELD PART#
323-4069 345-5443 219-3959 219-3960 219-3970 XMK00106 219-4212 219-0154
351-6059 105-0183 105-0173 105-0184 105-0174 001-5414 001-5415 001-6867
DESCRIPTION
door set, 73″ curved glass glass, curved, 1″ insulated, 71″ bulb, 25W, Teflon
coated, clear
lamp holder, twin-threaded heater, pad, 115V/90W
warmer, food, 208V, no drain switch, 30A 120/277V
switch, rocker, 20A/125V, 15A/250V thermometer, digital, solar/batt
extrusion, polyethylene, blk, vertical, RH extrusion, polyethylene, blk,
vertical, LH extrusion, polyethylene, blk, curved, RH extrusion, polyethylene,
blk, curved, LH
trim, side, exterior, RH trim, side, exterior, LH trim, front, laminate
REPLACEMENT PARTS LIST FOR 549-OR
14 13 16
10 17 18 17
5
6 7 8
1 234
9
14
15
9
18 10
19
12
20
21 25 23 24 22
KEY
1
2
3
4
5
6
7
8
9
10
11
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
DELFIELD PART#
001-5558 216-2667 351-6075 397-8070 218-2414 351-6097 351-6273 XMK-00132
001-5554 001-5555 105-0183 105-0173 105-0184 105-0174 001-5414 001-5415
001-6855 001-5278 351-6038 001-5243 219-3903 219-3919 351-6247 509-0025
352-6731
DESCRIPTION
baffle, fan 49″ motor, fan, morrill blade, fan, 7″ dia., aluminum bracket, fan
motor harness, fan motor, 78″ coil, evaporator, custom, 49″ valve, expansion,
1/4, HI, 404A fixture, fluorescent light, 36″ back, interior, louvered
diffuser, air, LH & RH extrusion, polyethylene, blk, vert, RH extrusion,
polyethylene, blk, vert, LH extrusion, polyethylene, blk, curved, RH
extrusion, polyethylene, blk, curved, LH trim, side, exterior, RH trim, side,
exterior LH trim, front, laminate, 549 louvers, s/s, 15 x 17 thermometer, dial
panel, access ballast, rapid start, 36″ lamp
switch, 15A/120V control, pressure, high control, temperature, -30-100
condensing unit, 1/2 hp, R-404A, med
14
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
FLUORESCENT LIGHT
500 Series Display Cases Service and Installation Manual
2 7
1
7
8 9
5 4 6
3
DELFIELD
KEY
PART#
DESCRIPTION
1
SMK00571
cap, end, top mtg, pigtail, -rem.
2
SMK00572
cap, end, top mtg, blank, -rem.
3
170-1045
diffuser, fluor. light, 24″
170-1046
diffuser, fluor. light, 36″
170-1047
diffuser, fluor. light, 48″
170-1054
diffuser, fluor. light, 60″
4
219-3906
lamp, fluorescent, 24″
219-3907
lamp, fluorescent, 36″
219-3908
lamp, fluorescent, 48″
219-3909
lamp, fluorescent, 60″
5
219-3939
lamp holder, left
6
219-3940
lamp holder, right
7
932-1266
screw, #8-32 x .50
8
218-3613
pigtail, male, 3.5″, rem. ballast
218-3595
pigtail, male, 9″, rem. ballast
9
932-1010
nut, hex, starlock, s/s, #6-32
*Refer to the exploded view of unit for a complete assembly part number
15 For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
500 Series Display Cases Service and Installation Manual
Door Assembly
DELFIELD
KEY
PART#
DESCRIPTION
323-7490
complete assembly, 537-CD/CR/CRR
323-4697
complete assembly, 549-CD/CR/CRR
323-4055
complete assembly, 549-CH
323-4698
complete assembly, 561-CD
323-4699
complete assembly, 573-CD
1
323-4636
323-4637
single roller, 537, 549 & 561 double roller, 573
2
order by size
bumper gasket, 241/8 & 537
323-3936
bumper gasket, 245/32, 549, 561 & 573
3
order by size
wiper gasket, 537
323-3936
wiper gasket, 2223/32, 549, 561 & 573
4
323-3947
spring 12″, green, 537
323-3949 323-3945
spring 12″, 549 spring 23″, gold, 561
323-3946
spring 30″, gold, 573
5
order by size
bottom track, 34 3/16, 537, black
323-3904
bottom track, 46 3/16, 549, black
order by size
bottom track, 46 3/16, 549-CH, black
323-3909
bottom track, 58 3/16, 561, black
323-3912
bottom track, 70 3/16, 573, black
6
order by size
top track, 34 3/16, 537, black
323-3904
top track, 46 3/16, 549, black
323-3922
top track, 58 3/16, 561
order by size 323-3925
Alum. top track, 46 3/16, 549-CH top track, 70 3/16, 573
Please Note: Gaskets & tracks order by dimensions · Plastic door glides order by
description reference #323-4055, 549-CH
6
3 4
2 1
1
1 5
16
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
4 2
1
500 Series Display Cases Service and Installation Manual
COMPRESSOR/COIL ASSEMBLY 537/549/561-CR/CRR
DELFIELD
KEY
PART#
1
010-1916
2
001-5251
001-5417
3
219-3919
4
219-3903
219-3904
5
219-3942
219-3927
6
351-6231
351-6072
7
216-2667
8
351-6184
9
352-6729
352-6746
352-6732
10
351-6084
11
218-3445
DESCRIPTION
coil pan assembly bracket, fan mounting bracket, fan mounting (537-CR) switch,
toggle, SPST ballast, rapid start (549 & 537-CR) ballast, rapid start (561)
control, SPST control, SPST (537-CR) evaporator coil, 404A evaporator coil,
404A (537-CR) motor, fan, 1450 rpm, CW (537, 549 & 561) blade, fan, 7″
plastic, CW condensing unit, 1/2 h.p., 404A (549-CR) condensing unit, 1/3
h.p., 404A (537-CR) condensing unit, 3/4 h.p., 404A (561-CR) valve, expansion,
1/2″, 404A harness, evaporator fan
COMPRESSOR/COIL ASSEMBLY 573-CR/CRR
DELFIELD
KEY
PART#
DESCRIPTION
1
010-1926
coil pan assembly
2
001-5292
bracket, fan mounting
3
219-3919
switch, toggle, SPST
4
219-3905
ballast, rapid start
5
219-3942
control, SPST
6
351-6246
evaporator coil, 404A
7
216-2667
motor, fan, 1450 rpm, CW
8
351-6184
blade, fan, 7″ plastic, CW
9
352-6732
condensing unit, 3/4 h.p., 404A (573-CR only)
10
351-6084
valve, expansion, 1/2″, 404A
11
218-3445
harness, evaporator fan
17 17 For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
500 Series Display Cases Service and Installation Manual
DELFIELD FOOD WELL (DFW) ASSEMBLY: WITH INFINITE CONTROL
For 500-CH Heated Units
DELFIELD
KEY
PART#
DESCRIPTION
XMK00106
Complete assembly, infinite w/o drain
1
GMK00061
Deflector plate
2
2
GMK00062
Bottom cover
3
016-0014
Food well, with drain
4
932-1353
Screw
5
219-4007
Element
6
932-1379
Screws (2)
7
343-4663
Insulation
8
219-4335
Thermostat non-adjustable
9
932-1007
Screw
10
GMK00063
Drain cover
11
932-1007
Screws (2)
12
219-4110
Infinite control, 240V
13
323-4557
Infinite control knob
14
219-4095
Pilot light, amber
10
4 7
NOTE: If you need four or more component parts, you must buy a complete assembly.
19
8
6
5
11
INFINITE CONTROL
KNOB
3
12
18
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
14 13
500 Series Display Cases Service and Installation Manual
REPLACEMENT PARTS LIST — NOT SHOWN ON EXPLODED VIEWS
DELFIELD PART#
DESCRIPTION
CR & CRR MODELS (MISC. PARTS)
Harness, wiring-female, 84″ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218-3596
Glass, curved, 1″, insulated, 35″ (537). . . . . . . . . . . . . . . . . . . . . . . . . . . 345-5319
Glass, curved, 1″, insulated, 47″ (549). . . . . . . . . . . . . . . . . . . . . . . . . . . 345-5439
Glass, curved, 1″, insulated, 59″ (561). . . . . . . . . . . . . . . . . . . . . . . . . . . 345-5441
Glass, curved, 1″, insulated, 71″ (573). . . . . . . . . . . . . . . . . . . . . . . . . . . 345-5443
Foot, leveler, adj., 1/2-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323-4696
Fixture, fluorescent light, 24″ remote, top light (537) . . . . . . . . . . . . . . XMKOO131
Fixture, fluorescent light, 36″ remote, top light (549) . . . . . . . . . . . . . . XMKOO132
Fixture, fluorescent light, 48″ remote, top light (561) . . . . . . . . . . . . . . XMKOO133
Fixture, fluorescent light, 60″ remote, top light (573) . . . . . . . . . . . . . . XMKOO134
Louver, s/s, 15 x 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 001-5278
Louver, s/s, 15 x 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 001-5279
Harness, light/fan motor, 78″ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218-3414
Switch, 15A/120V, SPST, ivory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3919
Holder, adj. shelf, beige, RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8121
Holder, adj. shelf, beige, LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8120
Control, pressure, dual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3942
Bracket, fan motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8070
Blade, fan, 7″ dia., Lexan, clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351-6184
Harness, evaporator fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218-3445
Support, shelf, (549-CR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 001-5235
Shelf, top/end, adj., 21 x 22.5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8122
Shelf, bottom/end, adj., 26 x 22.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8123
Door set, 49″ disp. case, with lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323-4697
Door set, 61″ disp. case, with lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323-4698
Shelf, top/center, adj., 21 x 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8125
Shelf, bottom/center, adj., 26 x 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8126
CD MODELS (MISC. PARTS) Harness, wiring-female, 84″ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218-3596 Glass, curved, .25″, insulated, 35″ (537) . . . . . . . . . . . . . . . . . . . . . . . . . 345-5400 Glass, curved, .25″, insulated, 47″ (549) . . . . . . . . . . . . . . . . . . . . . . . . . 345-5440 Glass, curved, .25″, insulated, 59″ (561) . . . . . . . . . . . . . . . . . . . . . . . . . 345-5442 Glass, curved, .25″, insulated, 71″ (573) . . . . . . . . . . . . . . . . . . . . . . . . . 345-5444 Fixture, fluorescent light, 24″ remote, top light (537) . . . . . . . . . . . . . . XMKOO131 Fixture, fluorescent light, 36″ remote, top light (549) . . . . . . . . . . . . . . XMKOO132 Fixture, fluorescent light, 48″ remote, top light (561) . . . . . . . . . . . . . . XMKOO133 Fixture, fluorescent light, 60″ remote, top light (573) . . . . . . . . . . . . . . XMKOO134 Foot, leveler, adj., 1/2-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323-4696 Switch, 15A/120V, (2) SPST, ivory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3918 Holder, adj. shelf, beige, RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8121 Holder, adj. shelf, beige, LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8120 Pigtail, male, 9″, rem. ballast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218-3595 Support, shelf, (549) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 001-5235 Shelf, bottom/end, adj., 21 x 22.5 (549 & 561) . . . . . . . . . . . . . . . . . . . . 397-8122 Shelf, adjustable, 21 x 33 (537) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8137 Shelf, top, center, adj. 21 x 24 (573) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8127 Shelf, bottom/end, adj., 26 x 22.5 (549 & 561) . . . . . . . . . . . . . . . . . . . . 397-8123 Shelf, adjustable, 26 x 33 (537) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8138 Shelf, bottom, center, adj. 26 x 24 (573) . . . . . . . . . . . . . . . . . . . . . . . . . 397-8128
DELFIELD PART#
DESCRIPTION
OR MODELS (MISC. PARTS) Motor, evaporator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216-2667 Blade, fan, 7″ dia., CW, 20 deg, alum . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351-6075 Harness, light/fan motor, 78′ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218-3414 Coil, evap., customer, 49″. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351-6097 Cond. unit, 1/2 h.p., R-404A, med . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352-6731 Control, temperature, -30-100%D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 509-0025 Valve, Expansion, 1/4, R-404A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351-6273 Ballast, rapid start, 36″ lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3903 Switch, 15A/120V, SPST, ivory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3919 Timer, 24 hours, clock face. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-4345 Harness, evaporator fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218-3445 Bracket, fan motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397-8070 Louver, s/s, 15 x 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 001-5278 Shelf, Lexan, .5″ x 10″ x 45.5″ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354-5339 Dial, Thermometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351-6038 CH Models (misc. parts) Lamp holder, twin-threaded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3960 Bulb, 25W, Teflon coating, clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3959 Heater, pad, 115V/90W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3970 Thermostat, nonadjustable, 480°F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-4335 Thermometer/digital, solar/batt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351-6059 Switch, rocker, 20A/125V, 15A/250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-0154 Switch, 30A, 120/277V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-4212
BALLASTS 120V ballast (537) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3902 120V ballast (549) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3903 120V ballast (561) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3904 120V ballast (573) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219-3905 220V ballast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . special order
19 For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
500 Series Display Cases Service and Installation Manual
STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD EQUIPMENT
Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage.
· A maximum of 1-hour is allowed to diagnose a defective component. · A
maximum of 1-hour is allowed for retrieval of parts not in stock. · A maximum
travel distance of 100 miles round trip and 2-hours will be reimbursed. ·
Overtime, installation/start-up, normal control adjustments, general
maintenance, glass breakage, freight damage, and/or
correcting and end-user installation error will not be reimbursed under
warranty unless pre-approved with a Service Work Authorization from Delfield.
You must submit the number with the service claim.
LABOR OF 1-HOUR IS ALLOWED TO REPLACE: · Thermostat · Infinite Switch · Door Jamb Switch · Solenoid Coil · Hi-limit/Thermal Protector Switch · Fan Delay/Defrost Termination Switch · Compressor Start Components and Overload Protector · Defrost Timer · Thermometer · Gear Box
· Contactor/Relay · Transformer · Evaporator/Condenser Fan Motor and Blade · Circulating Fan Motor and Blade · Microprocessor Control · Water Level Sensor/Probe · Door Hinges, Locks, and Gaskets · Condensate Element · Springs/Lowerator
LABOR OF 2 HOURS TO REPLACE: · Drawer Tracks/Cartridges · Pressure Control · Solenoid Valve
· Defrost Element · Heating Element · Locate/Repair Leak
LABOR OF 3 HOURS TO REPLACE: · EPR or CPR Valve · Expansion Valve
· Condenser or Evaporator Coil
LABOR OF 4 HOURS TO REPLACE · Compressor This includes recovery of refrigerant and leak check. $55.00 maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor fittings, solder, brazing rod, nitrogen, or similar fees.)
REFRIGERANTS · R22 A maximum of $4.00/lb. or 25¢/oz. will be reimbursed. · R134A A maximum of $5.00/lb. or 31¢/oz. will be reimbursed. · R404A A maximum of $15.00/lb. or $1.00/oz. will be reimbursed.
20
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
500 Series Display Cases Service and Installation Manual
STANDARD ONE YEAR WARRANTY (ONE YEAR PARTS, 90 DAYS LABOR.)
The Delfield Company (“Delfield”) warrants to the Original Purchaser of the
Delfield product (herein called the “Unit”) that such Unit, and all parts
thereof, will be free from defects in material and workmanship under normal
use and service for a period of one (1) year from the date of shipment of the
Unit to the Original Purchaser or, if the Original Purchaser returns the
warranty card completely filled out including the date of installation within
thirty (30) days of receipt of the Unit, one (1) year from the date of
installation. During this one year warranty period, Delfield will repair or
replace any defective part or portion there of returned to Delfield by the
Original Purchaser which Delfield determines was defective due to faulty
material or workmanship. The Original purchaser will pay all labor, crating,
freight and related costs incurred in the removal of the Unit of defective
component and shipment to Delfield, except that during a period of either
ninety (90) days from the date of shipment of the Unit to the Original
Purchaser or, if the Original Purchaser returns the warranty card completely
filled out including the date of installation within thirty (30) days of
receipt of the Unit, ninety (90) days from the date of installation Delfield
will pay all related labor costs. Delfield will pay the return costs if the
Unit or part thereof was defective.
The term “Original Purchaser” as used herein means that person, firm,
association, or corporation for whom the Unit was originally installed.
This warranty does not apply to any Unit or part thereof that has been
subjected to misuse, neglect, alteration, or accident, such as accidental
damage to the exterior finish, operated contrary to the recommendations
specified by Delfield; or repaired or altered by anyone other than Delfield in
any way so as to, in Delfield’s sole judgement, affect its quality or
efficiency. This warranty does not apply to any Unit that has been moved from
the location where it was originally installed. This warranty also does not
cover the refrigerator drier or the light bulbs used in the Unit. The warranty
is subject to the user’s normal maintenance and care responsibility as set
forth in the Service and Installation Manual, such as cleaning the condenser
coil, and is in lieu of all other obligations of Delfield. Delfield neither
assumes, nor authorizes any other person to assume for Delfield, any other
liability in connection with Delfield’s products.
basis, with credit being issued after the part has been received and inspected
at Delfield’s plant and determined by Delfield to be within this warranty.
Under no condition does this warranty give the Original Purchaser the right to
replace the defective Unit with a complete Unit of the same manufacturer or of
another make. Unless authorized by Delfield in writing, this warranty does not
permit the replacement of any part, including the motor-compressor, to be made
with the part of another make or manufacturer.
No claims can be made under this warranty for spoilage of any products for any
reason, including system failure.
The installation contractor shall be responsible for building access, entrance
and field conditions to insure sufficient clearance to allow any hood(s),
vent(s), or Unit(s) if necessary, to be brought into the building. Delfield
will not be responsible for structural changes or damages incurred during
installation of the Unit or any exhaust system.
Delfield shall not be liable in any manner for any default or delay in
performance hereunder caused by or resulting from any contingency beyond
Delfield’s control, including, but not limited to, war, governmental
restrictions or restraints, strike, lockouts, injunctions, fire, flood, acts
of nature, short or reduced supply of raw materials, or discontinuance of the
parts by the original part manufacturer.
Except as provided in any Additional Four Year Protection Plan, if applicable,
and the Service Labor Contract, if applicable, the foregoing is exclusive and
in lieu of all other warranties, whether written or oral, express or implied.
This warranty supersedes and excludes any prior oral or written
representations or warranties. Delfield expressly disclaims any implied
warranties of merchantability, fitness for a particular purpose of compliance
with any law, treaty, rule or regulation relating to the discharge of
substances into the environment. The sole and exclusive remedies of any person
relating to the Unit, and the full liability of Delfield for any breach of
this warranty, will be as provided in this warranty.
Removal or defacement of the original Serial Number or Model Number from any
Unit shall be deemed to release Delfield from all obligations hereunder or any
other obligations, express or implied.
Parts furnished by suppliers to Delfield are guaranteed by Delfield only to
the extent of the original manufacturer’s express warranty to Delfield.
Failure of the Original Purchaser to receive such manufacturer’s express
warranty to Delfield. Failure of the Original Purchaser to receive such
manufacturers warranty shall in no way create any warranty, expressed or
implied, or any other obligation or liability on Delfield’s part in respect
thereof.
IF THE CUSTOMER IS USING A PART THAT RESULTS IN A VOIDED WARRANTY AND A
DELFIELD AUTHORIZED REPRESENTATIVE TRAVELS TO THE INSTALLATION ADDRESS TO
PERFORM WARRANTY SERVICE, THE SERVICE REPRESENTATIVE WILL ADVISE CUSTOMER THE
WARRANTY IS VOID. SUCH SERVICE CALLS WILL BE BILLED TO CUSTOMER AT THE
AUTHORIZED SERVICE CENTER’S THEN APPLICABLE TIME AND MATERIALS RATES.
CONSIDER: CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE.
If shipment of a replacement part is requested prior to the arrival in the
Delfield factory of the part claimed to be defective, the Original Purchaser
must accept delivery of the replacement part of a C.O.D.
Other than this Delfield Standard One Year Limited Warranty, any applicable
Delfield Additional Four Year Protection Plan or applicable Delfield Service
Labor Contract, the Original Purchaser agrees and acknowledges that no other
warranties are offered or provided in connection with or for the unit or any
other part thereof.
In no event will Delfield be liable for special, incidental or consequential
damages, or for damages in the nature of penalties.
IF DURING THE WARRANTY PERIOD, CUSTOMER USES A PART FOR THIS DELFIELD
EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY
FROM DELFIELD OR ANY OF ITS AUTHORIZED SERVICE CENTERS AND/OR THE PART BEING
USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID.
FURTHER, DELFIELD AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS DAMAGES
OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN
WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART
RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER. If the warranty becomes void,
Customer may purchase from Delfield, if available, a Service Agreement or
service at the then current time and materials rate.
For more information on Delfield warranty’s log on and check out the service
section of our web site at www.delfield.com.
21 For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
500 Series Display Cases Service and Installation Manual
ADDITIONAL FOUR YEAR PROTECTION PLAN (FOR MOTOR-COMPRESSOR ONLY)
Delfield Model# Serial #
Installation Date
In addition to the Standard One Year Warranty on the MotorCompressor contained
in the above listed Delfield product (the “Unit”), The Delfield Company
(“Delfield”) also agrees to repair, or exchange with similar or
interchangeable parts in design and capacity at Delfield’s option, the
defective Motor-Compressor contained in the Unit (the “Motor-Compressor), or
any part thereof, for the Original Purchaser only, at any time during the four
(4) years following the initial one (1) year period commencing on the date of
installation for the Original Purchaser. Failure of the Original Purchaser to
register the registration card containing the Original Purchasers name,
address, date of installation, model number and serial number of the Unit
containing the Motor-Compressor within 30 days from the date of installation
shall void this warranty. This additional warranty is only available if the
Motor-Compressor is inoperative due to defects in material or factory
workmanship, as determined by Delfield in its sole judgement and discretion.
The Original Purchaser shall be responsible for returning the defective Motor-
Compressor to Delfield prepaid, F.O.B. at the address shown on the back cover
of this manual.
The term “Original Purchaser” as used herein means that person, firm,
association, or corporation for whom the Unit was originally installed.
The term “Motor-Compressor” as used herein does not include unit base, air or
water cooled condenser, receiver, electrical accessories such as relay,
capacitors, refrigerant controls, or condenser fan/motor assembly. This
warranty does not cover labor charges incidental to the replacement of parts.
This warranty further does not include any equipment to which said condensing
unit is connected, such as cooling coils, temperature controls or refrigerant
metering devices. This warranty shall be void if the Motor-Compressor, in
Delfield’s sole judgement, has been subjected to misuse, neglect, alteration
or accident, operated contrary to the recommendations specified by the Unit
manufacturer, repaired or altered by anyone other than Delfield in any way so
as, in Delfield’s sole judgment, to affect its quality or efficiency or if the
serial number has been altered, defaced or removed. This Warranty does not
apply to a Motor-Compressor in any Unit that has been moved from the location
where it was originally installed. The addition of methyl chloride to the
condensing unit or refrigeration system shall void this warranty.
General Conditions Delfield shall not be liable in any manner for any default
or delay in performance hereunder caused by or resulting from any contingency
beyond Delfield’s control, including, but not limited to, war, governmental
restrictions or restraints, strike, lockouts, injunctions, fire, flood, acts
of nature, short or reduced supply of raw materials, or discontinuance of any
part or the MotorCompressor by the unit manufacturer.
Replacement of a defective Motor-Compressor is limited to one (1) Motor-
Compressor by us during the four (4) year period. Delfield shall replace the
Motor-Compressor at no charge.
This warranty does not give the Original Purchaser of the MotorCompressor the
right to purchase a complete replacement MotorCompressor of the same make or
of another make. It further does not permit the replacement to be made with a
Motor-Compressor of another kind unless authorized by Delfield. In the event
Delfield authorizes the Original Purchaser to purchase a replacement Motor-
Compressor locally, only the wholesale cost of the MotorCompressor is
refundable.
Expressly excluded from this warranty are damages resulting from spoilage of
goods.
Except as provided in any applicable Standard One Year Limited Warranty or
applicable Service Labor Contract, the foregoing is exclusive and in lieu of
all other warranties, whether written or oral, express or implied. This
Warranty supersedes and excludes any prior oral or written representations or
warranties. Delfield expressly disclaims any implied warranties of
merchantability, fitness for a particular purpose or compliance with any law,
treaty, rule or regulation relating to the MotorCompressor, and the full
liability of Delfield for any breach of this warranty, will be as provided in
this warranty.
Other than any applicable Delfield Standard One year Limited Warranty, this
Delfield Additional Four Year Protection Plan and any applicable Delfield
Service Labor Contract, the Original Purchaser agrees and acknowledges that no
other warranties are offered or provided in connection with or for the Motor-
Compressor or any part thereof.
In no event will Delfield be liable for special, incidental or consequential
damages, or for damages in the nature of penalties.
22
For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
NOTES:
500 Series Display Cases Service and Installation Manual
23 For customer service, call 800-733-8829, 800-773-8821, Fax 989-773-3210, www.delfield.com
TM
Delfield®
Mt. Pleasant, MI
Covington, TN
Thank you for choosing Delfield!
Help is a phone call away. Help our team of professional, courteous customer
service reps by having your model number and serial number
available at the time of your call
800-733-8829.
Model: ____ S/N: ___
Installation Date: ____
For a list of Delfield’s authorized parts depots, visit our website at
www.delfield.com.
TM
Delfield®
980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A. ·
989-773-7981 or
800-733-8829 · Fax
989-773-3210 · www.delfield.com
Delfield reserves the right to make changes in design or specifications
without prior notice. ©2010 The Delfield Company. All rights reserved. Printed
in the U.S.A.
DM500 04/10
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>