DELFIELD 200 Series Drop In Ice Bin Instruction Manual

June 4, 2024
DELFIELD

DELFIELD 200 Series Drop In Ice Bin

DELFIELD 200 Series Drop In Ice Bin
PRODUCT

Original Instructions
Installation, Operation and Maintenance Manual
This manual is updated as new information and models are released. Visit our website for the latest manualDELFIELD 200 Series Drop In Ice Bin FIG
1

Caution
Read this instruction before operating this equipment.

Safety Notices

  • Warning
    Read this manual thoroughly before operating, installing or performing maintenance on the equipment. Failure to follow instructions in this manual can cause property damage, injury or death.

  • DANGER
    Do not lift the condensing unit by the refrigerant tubing or other components. These features will not support the condensing unit weight. Injury and unit damage may occur!

  • DANGER
    Do not install or operate equipment that has been misused, abused, neglected, damaged, or altered/modified from that of original manufactured specifications.

  • DANGER
    All utility connections and fixtures must be maintained in accordance with Local and national codes.

  • DANGER
    Keep power cord AWAY from HEATED surfaces. DO NOT immerse power cord or plug in water. DO NOT let power cord hang over edge of table or counter.

  • Warning
    Authorized Service Representatives are obligated to follow industry standard safety procedures, including, but not limited to, local/national regulations for disconnection / lock out / tag out procedures for all utilities including electric, gas, water and steam.

  • Warning
    This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision concerning use of the appliance by a person responsible for their safety. Do not allow children to play with this appliance.

  • Warning
    Do not store or use gasoline or other flammable vapors or liquids inside or within the vicinity of this or any other appliance. Never use flammable oil soaked cloths or combustible cleaning solutions, for cleaning..

  • Warning
    Use caution when handling metal surface edges of all equipment

  • Warning
    This product contains chemicals known to the State of California to cause cancer and/or birth defects or other reproductive harm. Operation, installation, and servicing of this product could expose you to airborne particles of glass wool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm.

  • Warning
    Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer.

  • Warning
    DO NOT touch refrigeration lines inside units; some may exceed temperatures of 200°F (93.3°C).

  • Caution
    Use caution handling, moving and use of the R290 refrigerators to avoid either damaging the refrigerant tubing or increasing the risk of a leak. Components shall be replaced with like components. Servicing shall be done by factory- authorized service personnel to minimize the risk of possible ignition due to incorrect parts or improper service.

  • Note
    Proper installation, care and maintenance are essential for maximum performance and trouble-free operation of your equipment. Visit our website www. wbtkitchencare.com for manual updates, translations, or contact information for service agents in your area.

  • Note
    These appliances are intended to be used for commercial applications, for example in kitchens of restaurants, canteens, hospitals and in commercial enterprises such as bakeries, butcheries, etc., but not for continuous mass production of food.

  • Note
    Climatic class 4 is defined as ambient conditions of 30°C and 55% relative humidity, according to ISO 23953-2.

  • Note
    This product utilizes Ecomate blowing agent methyl format

General Information

Model NumbersDELFIELD 200 Series Drop In Ice Bin FIG
2 Serial Number Location
Always have the serial number of your unit available when calling for parts or service.


Warranty Information

  • Register your product for warranty,
  • Verify warranty information,
  • View and download a copy of your warranty, at www.delfield.com/warranty

Regulatory Certifications
DOMESTIC MODELS
All domestic models are certified by:

  • National Sanitation Foundation (NSF) All domestic electrical models are certified by:
  • Underwriters Laboratories (UL)
  • Underwriters Laboratories of Canada (cUL)

EXPORT MODELS
All export models are certified by:

  • National Sanitation Foundation (NSF) Export electrical models are certified by:
  • Technical Inspection Association
  • European Conformity

Installation

  • DANGER
    Installation must comply with all applicable fire and health codes in your jurisdiction.

  • DANGER
    Use appropriate safety equipment during installation and servicing.

  • Warning
    Remove all removable panels before lifting and installing.

  • Warning
    Do not damage the refrigeration circuit when installing, maintaining or servicing the unit.

Location

  • Warning
    This equipment must be positioned so that the plug is accessible unless other means for disconnection from the power supply (e.g., circuit breaker or disconnect switch) is provided.

  • Warning
    These appliances are to be connected with flexible connections for equipotential bonding and connection to services such as electricity supply, water supply, gas supply, and steam supply such that the appliance can be moved in the direction required for cleaning a distance not less that the dimension of the application in the direction of movement plus 500mm without the flexible connections becoming taught or being subject to strain.

  • Warning
    To avoid instability the installation area must be capable of supporting the combined weight of the equipment and product. Additionally the equipment must be level side to side and front to back.

  • Warning
    This equipment is intended for indoor use only. Do not install or operate this equipment in outdoor areas.

  • Caution
    Do not position the air intake vent near steam or heat exhaust of another appliance.

The location selected for the equipment must meet the following criteria. If any of these criteria are not met, select another location.

  • Units are intended for indoor use only.
  • The location MUST be level, stable and capable of supporting the weight of the equipment.
  • The location MUST be free from and clear of combustible materials.
  • Equipment MUST be level both front to back and side to side.
  • Position the equipment so it will not tip or slide.
  • Recommended air temperature is 41° – 86°F (5° – 30°C).
  • Proper air supply for ventilation is REQUIRED AND CRITICAL for safe and efficient operation. Refer to Clearance Requirements chart on page 7.
  • Do not obstruct the flow of ventilation air. Make sure the air vents of the equipment are not blocked.
  • Do not install the equipment directly over a drain. Steam rising up out of the drain will adversely affect operation, air circulation, and damage electrical /electronic components.

Clearance Requirements

DANGER
Minimum clearance requirements are the same for noncombustible locations as for combustible locations. The flooring under the appliance must be made of a noncombustible material.

DANGER
Risk of fire/shock. All minimum clearances must be maintained. Do not obstruct vents or openings.

Condensing Unit Bottom & Sides
0” (0cm)

  • Keep the vents clean and free of obstruction.

Weight Of EquipmentDELFIELD 200 Series Drop In Ice Bin FIG
2

Cutout Installation Dimension

Mounting Studs
Mark the stud locations according to the measurements or place the equipment in the cutout to mark the stud locations. Drill 0.37” (1cm) diameter holes through the counter for the studs.
203 Details
When mounting a 203 ice chest into a wood counter secure it with provided clips. When mounting into a stainless steel counter, use silicone.
204 & 204P Cutout Details DELFIELD 200 Series Drop In Ice Bin FIG
5

240 Details
Ice chest with cover, model 240 can be set on a counter or plate shelf. Select the desired location. Mark the drain location and drill a 1.50” (4cm) diameter hole. DELFIELD 200 Series Drop In Ice Bin FIG
6

305 Cutout Details

307 Cutout DetailsDELFIELD 200 Series Drop In Ice Bin FIG
8

N225 & N227 STANDARD INSTALLATION DETAILS
For any non-standard installation consult the factory.

  1. Install a GFCI receptacle a minimum of 14” (36cm) up from the cabinet bottom inside the partitions.

  2. Cabinet interior minimum dimensions: DELFIELD 200 Series Drop In Ice Bin FIG 10

  3. Place the condensing unit through the counter cutout.

  4. Extend the telescoping duct from the front of the condensing unit to the back of the louver. Export models do not have a telescoping duct, skip to step 6.

  5. Put eight provided screws through the telescoping duct side walls to hold it at the desired depth.
    Use Screws to Secure Desired Depth 3 of 8 Screws Shown

  6. Partitions must fully extend front to back and top to bottom.

  7. Louver cutout must extend to bottom of cabinet and align with condenser face.
    NOTE: The louver provided must be installed in front of the condensing unit’s finned coil. Any restriction to the proper air flow will void the compressor warranty.

    • Louver measures 13.00” x 25.00” (33cm x 64cm).
    • Louver Cutout Size is 11.50” x 22.50” (29cm x 57cm)(typical installation).

N225 & N227 ALTERNATE INSTALLATION DETAILS
NOTE: This installation is not recommended as it will limit access to the control DELFIELD 200 Series Drop In Ice Bin FIG 15

  1. Install partitions between drop-in freezer and other electrical appliances if they are located in the same cabinet. Partitions must fully extend front to back and top to bottom.
  2. Install a GFCI receptacle a minimum of 14” (36cm) up from the cabinet bottom inside the partitions. Run the outlet to a switch. With limited access to the control, a switch will make it easy to turn the unit off for defrost.
  3. Louver cutout must extend to bottom of cabinet. NOTE: Any restriction to the proper air flow will void the compressor warranty.
    • Louver measures 13.00” x 25.00” (33cm x 64cm).
    • Louver Cutout Size is 11.50” x 22.50” (29cm x 57cm)(typical installation).
    • An additional opening in cabinet to permit removal of heated air is recommended. Cut opening 8”x11”, a total of 88 square inches (20cm x 28cm, a total of 568 square centimeters).
  4. Remove the telescoping duct from the condensing unit.
  5. Place the condensing unit through the counter cutout.
  6. Construct a 9”x9” air duct (not provided) connecting the condenser face to the louver.DELFIELD 200 Series Drop In Ice Bin FIG 17

Electrical Service

  • DANGER
    Check all wiring connections, including factory terminals, before operation. Connections can become loose during shipment and installation.

  • Warning
    This appliance must be grounded and all field wiring must conform to all applicable local and national codes. Refer to rating plate for proper voltage. It is the responsibility of the end user to provide the disconnect means to satisfy the authority having jurisdiction.

  • VOLTAGE
    All electrical work, including wire routing and grounding, must conform to local, state and national electrical codes.
    The following precautions must be observed:

    • The equipment must be grounded.
    • A separate fuse/circuit breaker must be provided for each unit.
    • The maximum allowable voltage variation is ±10% of the rated voltage at equipment start-up (when the electrical load is highest).
    • Check all green ground screws, cables and wire connections to verify they are tight before start-up.

GROUND FAULT CIRCUIT INTERRUPTER
Ground Fault Circuit Interrupter (GFCI/GFI) protection is a system that shuts down the electric circuit (opens it) when it senses an unexpected loss of power, presumably to ground. Welbilt does not recommend the use of GFCI/GFI circuit protection to energize our equipment. If code requires the use of a GFCI/GFI then you must follow the local code. The circuit must be dedicated, sized properly and there must be a panel GFCI/GFI breaker. We do not recommend the use of GFCI/GFI outlets to energize our equipment as they are known for more intermittent nuisance trips than panel breakers.

RATED AMPERAGES, HORSEPOWER, VOLTAGE & POWER CORD CHART

  • Note
    These appliances will operate within the marked rated voltage range without adjustment.

  • Note
    This symbol indicates the location of the equipotential bonding conductor connection.

Refrigeration

Export models are temperature class N.

Drain Connections

  • Warning
    If a mechanically cooled refrigerated base does not have a condensate evaporator supplied, you must connect the condensate line to a suitable drain. Otherwise, water will collect on the floor, causing a potentially hazardous situation.

  • Warning
    Moisture collecting from improper drainage can create a slippery surface on the floor and a hazard to employees. It is the owner’s responsibility to provide a container or outlet for drainage.

Water Connection

  • Warning
    Connect to a potable water supply only.

All 1/2” (13mm) IPS water inlets must be field connected following local code requirements.
Drain
Provided 1” (25mm) drain, nut and washer must be field installed to an appropriate container or floor drain following local code requirements. Sinks come standard with 1-1/2” basket strainer assemblies.
Drain Installation Instructions

  1. Drain kit should include a drain, washer and nut.
  2. Remove/drill foam out of drain hole.
  3. Apply thin ring of plumbers putty around the drain.
  4. From the inside drop the drain into the drain hole.
  5. From the outside secure the drain with the washer and nut.
  6. Tighten the nut with channel locks, use a fork to hold the drain in place if necessary.
  7. Clean up excess plumbers’ putty.

Operation

  • DANGER
    The on-site supervisor is responsible for ensuring that operators are made aware of the inherent dangers of operating this equipment.

  • DANGER
    Do not operate any appliance with a damaged cord or plug. All repairs must be performed by a qualified service company.

  • DANGER
    Never stand on the unit! They are not designed to hold the weight of an adult, and may collapse or tip if misused in this manner.

  • Warning
    Do not contact moving parts.

  • Warning
    All covers and access panels must be in place and properly secured, before operating this equipment.

  • Warning
    Damp or wet hands may stick to cold surfaces.

  • Warning
    Never use sharp objects or tools to remove ice or frost. Do not use mechanical devices or other means to accelerate the defrosting process.

  • Warning
    The operator of this equipment is solely responsible for ensuring safe holding temperature levels for all food items. Failure to do so could result in unsafe food products for customers.

  • Warning
    Do not block the supply and return air grills or the air space around the air grills. Keep plastic wrappings, paper, labels, etc. from being airborne and lodging in the grills. Failure to keep the air grills clear will result in the unsatisfactory operation of the system.

115Volt N225P & N227P Operation
The models N225P and N227P are designed to hold refrigerated or frozen product. They are set at the factory at a temperature range of -5°F to 5°F (-21°C to -15°C).Available temperature range is -5°F to 40°F (-21°C to 4°C).
The temperature control is located on the condensing housing.

Temperature Control

  1. At initial start-up or anytime power is disconnected, then reconnected to the unit, the control will go into normal cooling mode.
  2. The temperature control will cycle the compressor and condenser fan motor to maintain proper temperature.

Note
The temperature displayed is for refrigeration set point purposes only. Display does not reflect air or product temps in unit.

Defrost
Mechanically cooled freezers should be defrosted after 3/8” of ice accumulation. To defrost disconnect power to the equipment or put into stand- by mode. Never use sharp objects or tools to clean or scrape ice/frost build up from the refrigerated cold pans. A puncture could cause irreparable damage to the refrigeration system.

TEMPERATURE CONTROL & DISPLAY

All alarms sound for approximately 10 seconds and then are silent for 50 seconds. It will do that for 15 cycles and then remain silent. The alarm code will still be present on the display until the fault clears.

Press the upper or lower right button.

  • Display shows actual set-point (blinking).
  • If buttons are untouched for 3 seconds returns to normal.
  • Increase the set-point by pressing the upper button. Max value depends on parameters in control.
  • Decrease the set-point by pressing the lower button. Min value depends on parameters in control.
  • If buttons are untouched for 3 seconds return to normal and store a new set-point.

Press the lower left button for 5 seconds.

  • Unit goes into stand-by mode.
  • The display will read Off, then a period.
  • Press the lower left button again for 5 seconds.
  • The display will read On.
  • The unit will then start up in normal cooling mode.

Temperature Alarm
The alarm will sound and flash HI or LO 90 minutes after the unit has reached its alarm temperature point or after any power interruption if the temperature is above or below the alarm set points.

CHANGING DISPLAY FROM FAHRENHEIT TO CELSIUS ON ERC112 CONTROL

  1. Simultaneously hold the up and down arrows for 5 seconds to access menu for password-protected parameters.
  2. Screen should temporarily flash PAS and then move to a numeric screen.
  3. Scroll to 187 using the up/down arrows and push the stand-by button (lower left button) to enter.
  4. Scroll to dis using the up/down arrows and push the standby button (lower left button) to enter into the display menu.
  5. Scroll to CFu using the up/down arrows and push the standby button (lower left button) to enter the display unit menu.
  6. F should be displayed indicating Fahrenheit. Use the down arrow to change it to -C for Celsius and hit the stand-by button (lower left button) to enter the change.
  7. Push the defrost button (upper left button) to move out of the display unit menu.
  8. Push the defrost button (upper left button) to move out of the display menu and back to the normal display.
    NOTE: For steps 7 and 8, display will return back to normal display after 30 seconds of inactivity.

230-240V Export N225-E & N227-E Operation
The models N225-E and N227-E are designed to hold frozen products at a temperature range of 5°F to -5°F (-15°C to
-21°C). After installation, the unit will begin operating simply by plugging it into the proper outlet. If the unit does not operate after being plugged in, check to see if the thermostat is in the OFF position.

Export Defrosting
Mechanically cooled freezers should be defrosted after 3/8” of ice accumulation. To defrost disconnect power to the equipment or turn the thermostat knob to the OFF position. Never use sharp objects or tools to clean or scrape ice/frost build up from the refrigerated cold pans. A puncture could cause irreparable damage to the refrigeration system.

Maintenance

  • DANGER
    It is the responsibility of the equipment owner to perform a Personal Protective Equipment Hazard Assessment to ensure adequate protection during maintenance procedures.

  • DANGER
    Failure to disconnect the power at the main power supply disconnect could result in serious injury or death. The power switch DOES NOT disconnect all incoming power.

  • DANGER
    Disconnect electric power at the main power disconnect for all equipment being serviced. Observe correct polarity of incoming line voltage. Incorrect polarity can lead to erratic operation.

  • Warning
    Never use sharp objects or tools to remove ice or frost. Do not use mechanical devices or other means to accelerate the defrosting process.DELFIELD
200ASeries Drop In Ice Bin FIG 35

Cleaning and Sanitizing Procedures

  • Warning
    When using cleaning fluids or chemicals, rubber gloves and eye protection (and/or face shield) must be worn.

  • Caution
    Maintenance and servicing work other than cleaning as described in this manual must be done by an authorized service personnel.

  • Note
    When cleaning the unit, care should be taken to avoid the power cord. Keep water and/or cleaning solutions away from these parts.

  • Note
    Never use a high-pressure water jet for cleaning or hose down or flood the units with water. Do not use power cleaning equipment, steel wool, scrapers or wire brushes on stainless steel or painted surfaces.

  • Note
    Never use an acid based cleaning solution! Many food products have an acidic content, which can deteriorate the finish. Be sure to clean the stainless steel surfaces of ALL food products.

INTERIOR & EXTERIOR
You are responsible for maintaining the equipmen in accordance with the instructions in this manual. Maintenance procedures are not covered by the warranty. Clean the lid and the unit daily or more often to maintain cleanliness and efficient operation. Gaskets require daily cleaning to prevent mold and mildew build up and also to retain the elasticity of the gasket. Gasket cleaning can be done with the use of warm soapy water (not citrus based cleaner). Avoid full strength cleaning products on gaskets as this can cause them to become brittle and crack. Never use sharp tools or knives to scrape or clean the gasket. Wipe surfaces with a damp cloth rinsed in water to remove dust and dirt from the unit. Always rub with the “grain” of the stainless steel to avoid marring the finish. If a greasy residue persists, use a damp cloth rinsed in a mild dish soap and water solution. Wipe dry with a clean, soft cloth.

Never use steel wool or abrasive pads for cleaning. Never use chlorinated, citrus based or abrasive cleaners.
Stainless steel has a clear coating that is stain resistant and easy to clean. Products containing abrasives will damage the coating and scratch the panels. Daily cleaning may be followed by an application of stainless steel cleaner which will eliminate water spotting and fingerprints. Early signs of stainless steel breakdown are small pits and cracks. If this has begun, clean thoroughly and start to apply stainless steel cleaners in attempt to restore the steel.

N225 & N227 CLEANING THE CONDENSER COIL
In order to maintain proper refrigeration performance, the condenser fins must be cleaned of dust, dirt and grease regularly. It is recommended that this be done monthly. If conditions are such that the condenser is totally blocked in a month, the frequency of cleaning should be increased. Clean the condenser with a vacuum cleaner or stiff brush. If extremely dirty, a commercially available condenser cleaner may be required.
Failure to maintain a clean condenser coil can initially cause high temperatures and excessive run times. Continuous operation with a dirty or clogged condenser coil can result in compressor failure. Neglecting the condenser coil cleaning procedures will void any warranties associated with the compressor and cost to replace the compressor.

DELFIELD
980 SOUTH ISABELLA ROAD, MOUNT PLEASANT, MI 48858
800-733-8821 WWW.DELFIELD.COM

©2019 Welbilt Inc. except where explicitly stated otherwise. All rights reserved. Part Number 9291456 Rev00 03/21