Delfield 500 Series Refrigerated Display Case Installation Guide
- June 17, 2024
- DELFIELD
Table of Contents
- 500 Series Refrigerated Display Case
- RECEIVING AND INSPECTING THE EQUIPMENT
- INSTALLATION: 500 CD, CR, CRR & OR
- CONTROL SETTINGS: 500 CR & OR
- OPERATION: 500 CH
- CLEANING: ALL MODELS
- REPLACEMENT PARTS LIST FOR 537-CD
- FLUORESCENT LIGHT
- Door Assembly
- REPLACEMENT PARTS LIST
- STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD
- STANDARD ONE YEAR WARRANTY
- ADDITIONAL FOUR YEAR PROTECTION PLAN
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
500 Series
Service and Installation Manual
500 Series Refrigerated Display Case
Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 2.
IMPORTANT INFORMATION READ BEFORE USE PLEASE SAVE THESE INSTRUCTIONS!
SERIAL NUMBER LOCATION
The Serial number on all 500 Series units is located on the rear of the unit,
near the ON/OFF switch.
Always have the serial number of your unit available when calling for parts or
service. A complete list of authorized
Delfield parts depots can be found at
www.delfield.com.
©2010 The Delfield Company. All rights reserved. Reproduction without written
permission is prohibited. “Delfield” is a registered trademark of The Delfield
Company.
RECEIVING AND INSPECTING THE EQUIPMENT
Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building.
- Visually inspect the exterior of the package and skid or container. Any damage should be noted and reported to the delivering carrier immediately.
- If damaged, open and inspect the contents with the carrier.
- In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier. Notification should be made verbally as well as in written form.
- Request an inspection by the shipping company of the damaged equipment. This should be done within 10 days from receipt of the equipment.
- Check the lower portion of the unit to be sure adjustable feet are not bent.
- Also open the compressor compartment housing and visually inspect the refrigeration package. Be sure lines are secure and base is still intact.
- Freight carriers can supply the necessary damage forms upon request.
- Retain all crating material until an inspection has been made or waived.
Uncrating the Equipment
First cut and remove the banding from around the crate.
Remove the front of the crate material, use of some tools will be required. If
the unit is on legs remove the top of the crate as well and lift the unit off
the skid.
MODEL | DELFIELD | VOLTS/HERTZ | AMPS |
---|---|---|---|
NUMBER | PART # | PHASE | (includes lights & fan) |
Dry Storage Display Cases
537-CD| 078-5371| 115/60/1| 5.0|
549-CD| 078-5491| 115/60/1| 5.0|
561-CD| 078-5611| 115/60/1| 5.0|
573-CD| 078-5731| 115/60/1| 5.0|
MODEL| DELFIELD| NUMBER OF| VOLTS/HERTZ|
NUMBER| PART #| 12 X 20 WELLS| PHASE| AMPS
Heated Display Cases
549-CH| 078-5494| 3| 120, 208-240V/60/1| 19.0/21.0
561-CH| 078-5614| 4| 120, 208-240V/60/1| 24.0/27.0
573-CH| 078-5734| 5| 120, 208-240V/60/1| 30.0/34.0
MODEL| DELFIELD| | VOLTS/HERTZ| | EVAPORATOR CAPACITY|
CABINET LOAD
NUMBER| PART #| H.P.*| PHASE| AMPS| BTU/°TD|
BTU/HOUR
Remote Refrigerated Display Cases| | | | |
537-CRR* CONSULT FACTORY| 1/2| 115/60/1| 5.0| 180| 1730
549-CRR 078-5493| 1/2| 115/60/1| 5.0| 190| 2250
561-CRR 078-5613| 3/4| 115/60/1| 6.0| 190| 2770
573-CRR 078-5733| 3/4| 115/60/1| 6.0| 290| 3290
Recommended horsepower
MODEL| DELFIELD| | VOLTS/HERTZ| | CABINET LOAD| SYSTEM
CAPACITY| REFRIGERATION
NUMBER| PART #| H.P.| PHASE| AMPS| BTU/HOUR|
BTU/HOUR| CHARGE 404A
Self-Contained Refrigerated Display Cases
537-CR| 078-5372| 1/2| 115/60/1| 12.0| 1730| 3258| 32 oz.
549-CR| 078-5492| 1/2| 115/60/1| 12.0| 2250| 3316| 32 oz.
561-CR| 078-5612| 3/4| 115/60/1| 16.0| 2770| 4919| 48 oz.
573-CR| 078-5732| 3/4| 115/60/1| 16.0| 3290| 5387| 48 oz.
MODEL| DELFIELD| | VOLTS/HERTZ| | CABINET LOAD| SYSTEM
CAPACITY| REFRIGERATION
NUMBER| PART#| H.P.| PHASE| AMPS| BTU/HOUR|
BTU/HOUR| CHARGE 404A
Open Front Refrigerated Display Cases
549-OR**| 078-5495| 1/2| 115/60/1| 12.0| 2030| 3354| 32 oz.
INSTALLATION: 500 CD, CR, CRR & OR
Location
To meet NSF standards, all units must be sealed to the floor.
Be sure the location chosen has a floor strong enough to support the total
weight of the cabinet and contents.
Contents fully loaded in this product line can weigh as much as 1500 lbs.
Reinforce the floor as necessary to provide for maximum loading.
For the most efficient refrigeration, be sure to provide good air circulation
inside and out. Do not pack the refrigerator so full that air cannot
circulate. Be sure that the exterior of the unit has access to ample air.
Avoid hot corners and locations near stoves and ovens.
Leveling
To level unit, simply lower the four adjustable rubber feet located under the
unit to the floor and adjust until unit is level. A level cabinet will perform
better because the drain will empty properly, the doors will line up with the
frames correctly and the cabinet will not be subject to undue strain.
Plumbing
Self-contained models are standard with a condensate evaporator. If the
evaporator fails, the unit’s drain must have an outlet to an appropriate
drainage area or container.
Moisture collecting from improper drainage can create a slippery surface on
the floor and a hazard to employees. It is the owner’s and operator’s
responsibility to provide a container or outlet for drainage.
Electrical connection
Refer to the amperage data on page 3, the serial tag, your local code or the
National Electrical Code to be sure the unit is connected to the proper power
source. A protected circuit of the correct voltage and amperage must be run
for connection of the line cord, or permanent connection to the unit.
Self-contained units have an ON/OFF switch located on the operators side.
Simply turn the switch to ON to begin operation.
The power switch should be turned to OFF and the unit disconnected from the power source whenever performing service or maintenance functions.
OPERATION: 500 CD, CR, CRR & OR
On self-contained models, after turning the ON/OFF switch to ON, the unit’s
compressor will begin operating. Delfield display cases are designed to
maintain an operational temperature of 36°F to 40°F.
Do not load the storage area in a way that restricts the air flow. Overloading
will result in the loss of temperature. Do not throw items into the storage
area. The interior of the cabinet and the blower coil may be damaged by this
type of neglect, which is not covered under your warranty.
These units use HFC-404A refrigerant, and have a lock-out high pressure
limiting device.
Under severe overloading conditions, in the event of a condenser fan failure
or a plugged or blocked condenser, this device may shut down the refrigeration
system. See page 17 for part number information if a replacement is required.
CONTROL SETTINGS: 500 CR & OR
Pressure Control
The temperature is controlled by an adjustable pressure control located in the
machine compartment. An adjustable control has the word COLDER near the knob,
with an arrow to indicate the adjustment direction. These controls are field
adjustable and do not require a service agent. If you have any questions, feel
free to contact the Delfield Service Department.
The refrigeration systems on self-contained CR & OR models were adjusted at
the factory to maintain between 36°F and 40°F. No adjustment should be
necessary. If adjustment does become needed however, the factory recommended
settings are:
Low-pressure settings (CR models): 82 psi cut-in, 47 psi cut-out, 35 psi
differential.
Low-pressure settings (OR models): 82 psi cut-in, 40 psi cut-out, 42 psi
differential.
Operating pressures: High, 170 to 200 psi. Low, 30 to 37 psi.
In attempting to adjust the pressure control, you can do damage to your unit by accidentally adjusting the differential. Please make small incremental adjustments if a temperature adjustment is necessary, please contact the service department at Delfield 800-733-8829 #1, or your local service agent. Delfield is not responsible for charges incurred while having the pressure control adjusted.
INSTALLATION: 500 CH
Installation should be done by personnel certified and licensed to install and
maintain electrical appliances.
Location
Be sure the location chosen has a floor strong enough to support the total
weight of the cabinet and contents.
Contents fully loaded into this product line can weigh as much as 1500 lbs.
Reinforce the floor as necessary to provide for maximum loading.
Leveling
A level cabinet looks better and will perform better because the drain pan
will drain properly, the doors will line up with the frames properly, and the
cabinet will not be subject to undue strain.
Electrical connection
Connections must be made in accordance with all applicable local codes and/or
the National Electrical Code. Refer to the wiring diagrams on pages 6 and 7.
OPERATION: 500 CH
NOTE: Intended for DRY OPERATION ONLY.
Before the unit is used the first time for serving, turn the temperature knob
to “10” and heat the well for 20 minutes.
Do not be alarmed if smoke appears; this preheat should burn off any residue
or dust on the heating element.
Hot surfaces can cause serious burns. Always wear some type of protective covering on your hands and arms when removing lids or pans from the unit.
Never place food directly into the well. Always use pans.
Always place covers on pans when not serving to prevent food from drying out
and to reduce your operating cost.
For most efficient operation, keep covered insets empty in each well during
preheating and when the well is not in use.
Dry operation
- Pre-heat the well on “HIGH” for approximately 15 minutes.
- After pre-heating, set the control to your desired serving temperature.
Only 6” (15.2cm) deep insets should be used with a dry food well. When operated dry, the bottom of the food well will discolor. Refer to cleaning instructions to remove discoloration.
Temperature
Product in pans . . . . . . . . . . . . . . . . . . . . . . 140°F to 160°F
CLEANING: ALL MODELS
Clean the food wells daily. Wash with non-abrasive cleanser and non-abrasive
pad. If necessary, a mild abrasive may be used. Do not use steel wool.
For all stainless steel parts, use mild, non-abrasive soap or detergent and
warm water. This may be followed by an application of stainless steel cleaner
or polish which will eliminate water spotting and fingerprints and will bring
out the finish of the stainless steel.
Do not use a hose or pressure wash on these units. The water will damage the electrical components.
Cleaning the condenser (refrigerated units)
In order to maintain proper refrigeration, the condenser fins must be cleaned
of dust, dirt and grease every three months. If condenser is totally blocked
after three months increase cleaning frequency. Clean the condenser with a
vacuum cleaner or stiff brush. If extremely dirty, use a commercially
available condenser cleaner.
Cleaning the sliding door assembly
All Delfield 500 Series display cases feature a Pike sliding door assembly.
Regular cleaning of door tracks with mild soap and water will keep them free
of foreign matter insuring many years of use. The glass may be cleaned with a
glass cleaner.
WIRING: 500 CR
WIRING: 500 OR
WIRING: 500 CD
WIRING: 500 CH
REPLACEMENT PARTS LIST FOR 537-CD
KEY | QUANTITY | DELFIELD PART# | DESCRIPTION |
---|---|---|---|
1 | 1 | 001-3133 | mirror, acrylic, RH, 500-CD |
2 | 1 | 001-3134 | mirror, acrylic, LH, 500-CD |
3 | 1 | 397-8121 | holder, adj. shelf, RH |
4 | 1 | 397-8120 | holder, adj. shelf, LH |
5 | 2 | 001-5285 | diffuser, air 537-CD/CR |
6 | 2 | XMK00127 | fixture, flour. light, 24 remote |
7 | 4 | 001-5407 | support, shelf, 537-CD/CR |
8 | 2 | 001-5026 | clip, air diffuser, 537-CD |
9 | 1 | 397-8137 | shelf, adjustable, 21” x 33” |
10 | 1 | 397-8138 | shelf, adjustable, 26” x 33” |
11 | 1 | 323-7490 | door set, with lock, 537-CD/CR |
12 | 4 | 932-1095 | stud, threaded, s/s, 1/4-20 x .75 |
13 | 4 | 932-1401 | nut, 1/4-20, locking |
Please Note: Items not shown on exploded view are listed on page 17.
Door locks #323-3986 & door keys #323-3988
REPLACEMENT PARTS LIST FOR 549-CD
KEY | QUANTITY | DELFIELD PART# | DESCRIPTION |
---|---|---|---|
1 | 1 | 001-3133 | mirror, acrylic, RH, 500-CD |
2 | 1 | 001-3134 | mirror, acrylic, LH, 500-CD |
3 | 1 | 397-8121 | holder, adj. shelf, RH |
4 | 1 | 397-8120 | holder, adj. shelf, LH |
5 | 2 | XMK00128 | fixture, flour. light, 36 remote |
6 | 4 | 001-5235 | shelf support |
7 | 2 | 397-8122 | shelf, top |
8 | 2 | 397-8123 | shelf, bottom |
9 | 1 | 323-4697 | door assembly, with lock |
10 | 1 | 216-2677 | fan, axial |
Please Note: Items not shown on exploded view are listed on page 17.
Door locks #323-3986 & door keys #323-3988
REPLACEMENT PARTS LIST FOR 561-CD
KEY | QUANTITY | DELFIELD PART# | DESCRIPTION |
---|---|---|---|
1 | 1 | 001-3133 | mirror, acrylic, RH, 500-CD |
2 | 1 | 001-3134 | mirror, acrylic, LH, 500-CD |
3 | 1 | 397-8121 | holder, adj. shelf, RH |
4 | 1 | 397-8120 | holder, adj. shelf, LH |
5 | 2 | XMK00129 | fixture, flour. light, 48 remote |
6 | 4 | 001-5277 | shelf support |
7 | 2 | 397-8122 | shelf, top |
8 | 2 | 397-8123 | shelf, bottom |
9 | 1 | 323-4698 | door assembly, PIKE, with lock |
10 | 1 | 216-2677 | fan, axial |
11 | 1 | 397-8125 | shelf, top center |
12 | 1 | 397-8126 | shelf, bottom center |
Please Note: Items not shown on exploded view are listed on page 17.
Door locks #323-3986 & door keys #323-3988
REPLACEMENT PARTS LIST FOR 573-CD
KEY | QUANTITY | DELFIELD PART# | DESCRIPTION |
---|---|---|---|
1 | 1 | 001-3133 | mirror, acrylic, RH, 500-CD |
2 | 1 | 001-3134 | mirror, acrylic, LH, 500-CD |
3 | 1 | 397-8121 | holder, adj. shelf, RH |
4 | 1 | 397-8120 | holder, adj. shelf, LH |
5 | 2 | XMK00130 | fixture, flour. light, 60 remote |
6 | 4 | 001-5295 | shelf support |
7 | 2 | 397-8122 | shelf, top |
8 | 2 | 397-8123 | shelf, bottom |
9 | 1 | 323-4699 | door assembly, PIKE, with lock |
10 | 1 | 216-2677 | fan, axial |
11 | 1 | 397-8127 | shelf, top center |
12 | 1 | 397-8128 | shelf, bottom center |
Please Note: Items not shown on exploded view are listed on page 17.
Door locks #323-3986 & Pike door keys #323-3988
REPLACEMENT PARTS LIST FOR 537CR/CRR
KEY | QUANTITY | DELFIELD PART# | DESCRIPTION |
---|---|---|---|
1 | 1 | 001-3131 | mirror, acrylic, RH, 500-CR |
2 | 1 | 001-3132 | mirror, acrylic, LH, 500-CR |
3 | 1 | 397-8121 | holder, adj. shelf, RH |
4 | 1 | 397-8120 | holder, adj. shelf, LH |
5 | 2 | 001-5285 | diffuser, air 537-CD/CR |
6 | 2 | XMK00127 | fixture, flour. light, 24 remote |
7 | 4 | 001-5407 | support, shelf, 537-CD/CR |
8 | 1 | 001-5407 | divider, air flow, 537-CR |
9 | 1 | 397-8137 | shelf, adjustable, 21” x 33” |
10 | 1 | 397-8138 | shelf, adjustable, 26” x 33” |
11 | 1 | 323-7490 | door set, with lock, 537-CD/CR |
12 | 4 | 932-1095 | stud, threaded, s/s, 1/4-20 x .75 |
13 | 4 | 932-1401 | nut, 1/4-20, locking |
14 | 1 | 001-5422 | cover, coil, 537-CR |
15 | 4 | 001-5252 | clip, holding, coil cover |
16 | 4 | 932-1238 | screw, #8 x .75, H/N-P-TR-A |
Please Note: Items not shown on exploded view are listed on page 17.
Door locks #323-3986 & door keys #323-3988
REPLACEMENT PARTS LIST FOR 549-CR/CRR
KEY | QUANTITY | DELFIELD PART# | DESCRIPTION |
---|---|---|---|
1 | 1 | 001-3133 | mirror, acrylic, RH |
2 | 1 | 001-3132 | mirror, acrylic, LH |
3 | 1 | 397-8121 | holder, adj. shelf, RH |
4 | 1 | 397-8120 | holder, adj. shelf, LH |
5 | 2 | XMK00128 | fixture, flour. light, 36 remote |
6 | 4 | 001-5235 | shelf support |
7 | 2 | 397-8122 | shelf, top |
8 | 2 | 397-8123 | shelf, bottom |
9 | 1 | 323-4697 | door assembly, with lock |
Please Note: Items not shown on exploded view are listed on page 17.
Door locks #323-3986 & door keys #323-3988
REPLACEMENT PARTS LIST FOR 561-CR/CRR
KEY | QUANTITY | DELFIELD PART# | DESCRIPTION |
---|---|---|---|
1 | 1 | 001-3133 | mirror, acrylic, RH |
2 | 1 | 001-3132 | mirror, acrylic, LH |
3 | 1 | 397-8121 | holder, adj. shelf, RH |
4 | 1 | 397-8120 | holder, adj. shelf, LH |
5 | 2 | XMK00129 | fixture, flour. light, 48 remote |
6 | 4 | 001-5277 | shelf support |
7 | 2 | 397-8122 | shelf, top |
8 | 2 | 397-8123 | shelf, bottom |
9 | 1 | 323-4698 | door assembly, PIKE, with lock |
10 | 1 | 397-8125 | shelf, top center |
11 | 1 | 397-8126 | shelf, bottom center |
Please Note: Items not shown on exploded view are listed on page 17.
Door locks #323-3986 & door keys #323-3988
REPLACEMENT PARTS LIST FOR 573-CR/CRR
KEY | QUANTITY | DELFIELD PART# | DESCRIPTION |
---|---|---|---|
1 | 1 | 001-3133 | mirror, acrylic, RH |
2 | 1 | 001-3132 | mirror, acrylic, LH |
3 | 1 | 397-8121 | holder, adj. shelf, RH |
4 | 1 | 397-8120 | holder, adj. shelf, LH |
5 | 2 | XMK00130 | fixture, flour. light, 60 remote |
6 | 4 | 001-5295 | shelf support |
7 | 2 | 397-8122 | shelf, top |
8 | 2 | 397-8123 | shelf, bottom |
9 | 1 | 323-4699 | door assembly, PIKE, with lock |
10 | 1 | 397-8127 | shelf, top center |
11 | 1 | 397-8128 | shelf, bottom center |
Please Note: Items not shown on exploded view are listed on page 17.
Door locks #323-3986 & door keys #323-3988
REPLACEMENT PARTS LIST FOR 549-CH
KEY | DELFIELD PART# | DESCRIPTION |
---|---|---|
1 | 323-4055 | door set, 49” curved glass |
2 | 345-5439 | glass, curved, 1” insulated, 47” |
3 | 219-3959 | bulb, 25W, Teflon coated, clear |
4 | 219-3960 | lamp holder, twin-threaded |
5 | 219-3970 | heater, pad, 115V/90W |
6 | XMK00106 | warmer, food, 208V, no drain |
7 | 219-4212 | switch, 30A 120/277V |
8 | 219-0154 | switch, rocker, 20A/125V, 15A/250V |
9 | 351-6059 | thermometer, digital, solar/batt |
10 | 105-0183 | extrusion, polyethylene, blk, vertical, RH |
11 | 105-0173 | extrusion, polyethylene, blk, vertical, LH |
12 | 105-0184 | extrusion, polyethylene, blk, curved, RH |
13 | 105-0174 | extrusion, polyethylene, blk, curved, LH |
14 | 001-5414 | trim, side, exterior, RH |
15 | 001-5415 | trim, side, exterior, LH |
16 | 001-6855 | trim, front, laminate |
REPLACEMENT PARTS LIST FOR 561-CH
KEY | DELFIELD PART# | DESCRIPTION |
---|---|---|
1 | 323-4068 | door set, 61” curved glass |
2 | 345-5441 | glass, curved, 1” insulated, 59” |
3 | 219-3959 | bulb, 25W, Teflon coated, clear |
4 | 219-3960 | lamp holder, twin-threaded |
5 | 219-3970 | heater, pad, 115V/90W |
6 | XMK00106 | warmer, food, 208V, no drain |
7 | 219-4212 | switch, 30A 120/277V |
8 | 219-0154 | switch, rocker, 20A/125V, 15A/250V |
9 | 351-6059 | thermometer, digital, solar/batt |
10 | 105-0183 | extrusion, polyethylene, blk, vertical, RH |
11 | 105-0173 | extrusion, polyethylene, blk, vertical, LH |
12 | 105-0184 | extrusion, polyethylene, blk, curved, RH |
13 | 105-0174 | extrusion, polyethylene, blk, curved, LH |
14 | 001-5414 | trim, side, exterior, RH |
15 | 001-5415 | trim, side, exterior, LH |
16 | 001-6866 | trim, front, laminate |
REPLACEMENT PARTS LIST FOR 573-CH
KEY | DELFIELD PART# | DESCRIPTION |
---|---|---|
1 | 323-4069 | door set, 73” curved glass |
2 | 345-5443 | glass, curved, 1” insulated, 71” |
3 | 219-3959 | bulb, 25W, Teflon coated, clear |
4 | 219-3960 | lamp holder, twin-threaded |
5 | 219-3970 | heater, pad, 115V/90W |
6 | XMK00106 | warmer, food, 208V, no drain |
7 | 219-4212 | switch, 30A 120/277V |
8 | 219-0154 | switch, rocker, 20A/125V, 15A/250V |
9 | 351-6059 | thermometer, digital, solar/batt |
10 | 105-0183 | extrusion, polyethylene, blk, vertical, RH |
11 | 105-0173 | extrusion, polyethylene, blk, vertical, LH |
12 | 105-0184 | extrusion, polyethylene, blk, curved, RH |
13 | 105-0174 | extrusion, polyethylene, blk, curved, LH |
14 | 001-5414 | trim, side, exterior, RH |
15 | 001-5415 | trim, side, exterior, LH |
16 | 001-6867 | trim, front, laminate |
REPLACEMENT PARTS LIST FOR 549-OR
KEY | DELFIELD PART# | DESCRIPTION |
---|---|---|
1 | 001-5558 | baffle, fan 49” |
2 | 216-2667 | motor, fan, morrill |
3 | 351-6075 | blade, fan, 7” dia., aluminum |
4 | 397-8070 | bracket, fan motor |
5 | 218-2414 | harness, fan motor, 78” |
6 | 351-6097 | coil, evaporator, custom, 49” |
7 | 351-6273 | valve, expansion, 1/4, HI, 404A |
8 | XMK-00132 | fixture, fluorescent light, 36” |
9 | 001-5554 | back, interior, louvered |
10 | 001-5555 | diffuser, air, LH & RH |
11 | 105-0183 | extrusion, polyethylene, blk, vert, RH |
12 | 105-0173 | extrusion, polyethylene, blk, vert, LH |
13 | 105-0184 | extrusion, polyethylene, blk, curved, RH |
14 | 105-0174 | extrusion, polyethylene, blk, curved, LH |
15 | 001-5414 | trim, side, exterior, RH |
16 | 001-5415 | trim, side, exterior LH |
17 | 001-6855 | trim, front, laminate, 549 |
18 | 001-5278 | louvers, s/s, 15 x 17 |
19 | 351-6038 | thermometer, dial |
20 | 001-5243 | panel, access |
21 | 219-3903 | ballast, rapid start, 36” lamp |
22 | 219-3919 | switch, 15A/120V |
23 | 351-6247 | control, pressure, high |
24 | 509-0025 | control, temperature, -30-100 |
25 | 352-6731 | condensing unit, 1/2 hp, R-404A, med |
FLUORESCENT LIGHT
KEY | DELFIELD PART# | DESCRIPTION |
---|---|---|
1 | SMK00571 | cap, end, top mtg, pigtail, -rem. |
2 | SMK00572 | cap, end, top mtg, blank, -rem. |
3 | 170-1045 | diffuser, fluor. light, 24” |
170-1046 | diffuser, fluor. light, 36” | |
170-1047 | diffuser, fluor. light, 48” | |
170-1054 | diffuser, fluor. light, 60” | |
4 | 219-3906 | lamp, fluorescent, 24” |
219-3907 | lamp, fluorescent, 36” | |
219-3908 | lamp, fluorescent, 48” | |
219-3909 | lamp, fluorescent, 60” | |
5 | 219-3939 | lamp holder, left |
6 | 219-3940 | lamp holder, right |
7 | 932-1266 | screw, #8-32 x .50 |
8 | 218-3613 | pigtail, male, 3.5”, rem. ballast |
9 | 218-3595 | pigtail, male, 9”, rem. ballast |
932-1010 | nut, hex, starlock, s/s, #6-32 |
*Refer to the exploded view of unit for a complete assembly part number
Door Assembly
KEY | DELFIELD PART# | DESCRIPTION |
---|---|---|
323-7490 | complete assembly, 537-CD/CR/CRR | |
323-4697 | complete assembly, 549-CD/CR/CRR | |
323-4055 | complete assembly, 549-CH | |
323-4698 | complete assembly, 561-CD | |
323-4699 | complete assembly, 573-CD | |
1 | 323-4636 | |
323-4637 | single roller, 537, 549 & 561 |
double roller, 573
2| order by size
323-3936| bumper gasket, 241/8 & 537
bumper gasket, 245/32, 549, 561 & 573
3| order by size
323-3936| wiper gasket, 537
wiper gasket, 2223/32, 549, 561 & 573
4| 323-3947| spring 12”, green, 537
323-3949| spring 12”, 549
323-3945| spring 23”, gold, 561
323-3946| spring 30”, gold, 573
5| order by size 323-3904
order by size 323-3909
323-3912| bottom track, 34 3/16, 537, black
bottom track, 46 3/16, 549, black bottom track, 46 3/16, 549-CH, black bottom
track, 58 3/16, 561, black
bottom track, 70 3/16, 573, black
6| order by size 323-3904
323-3922
order by size 323-3925| top track, 34 3/16, 537, black
top track, 46 3/16, 549, black
top track, 58 3/16, 561 Alum. top track, 46 3/16, 549-CH
top track, 70 3/16, 573
Please Note: Gaskets & tracks order by dimensions • Plastic door glides order by description reference #323-4055, 549-CH
COMPRESSOR/COIL ASSEMBLY 537/549/561-CR/CRR
KEY | DELFIELD PART# | DESCRIPTION |
---|---|---|
1 | 010-1916 | coil pan assembly |
2 | 001-5251 | bracket, fan mounting |
001-5417 | bracket, fan mounting (537-CR) | |
3 | 219-3919 | switch, toggle, SPST |
4 | 219-3903 | ballast, rapid start (549 & 537-CR) |
219-3904 | ballast, rapid start (561) | |
5 | 219-3942 | control, SPST |
219-3927 | control, SPST (537-CR) | |
6 | 351-6231 | evaporator coil, 404A |
351-6072 | evaporator coil, 404A (537-CR) | |
7 | 216-2667 | motor, fan, 1450 rpm, CW (537, 549 & 561) |
8 | 351-6184 | blade, fan, 7” plastic, CW |
9 | 352-6729 | condensing unit, 1/2 h.p., 404A (549-CR) |
10 | 352-6746 | condensing unit, 1/3 h.p., 404A (537-CR) |
352-6732 | condensing unit, 3/4 h.p., 404A (561-CR) | |
351-6084 | valve, expansion, 1/2”, 404A | |
11 | 218-3445 | harness, evaporator fan |
COMPRESSOR/COIL ASSEMBLY 573-CR/CRR
KEY | DELFIELD PART# | DESCRIPTION |
---|---|---|
1 | 010-1926 | coil pan assembly |
2 | 001-5292 | bracket, fan mounting |
3 | 219-3919 | switch, toggle, SPST |
4 | 219-3905 | ballast, rapid start |
5 | 219-3942 | control, SPST |
6 | 351-6246 | evaporator coil, 404A |
7 | 216-2667 | motor, fan, 1450 rpm, CW |
8 | 351-6184 | blade, fan, 7” plastic, CW |
9 | 352-6732 | condensing unit, 3/4 h.p., 404A (573-CR only) |
10 | 351-6084 | valve, expansion, 1/2”, 404A |
11 | 218-3445 | harness, evaporator fan |
DELFIELD FOOD WELL (DFW) ASSEMBLY: WITH INFINITE CONTROL
For 500-CH Heated Units
KEY | DELFIELD PART# | DESCRIPTION |
---|---|---|
XMK00106 | Complete assembly, infinite w/o drain | |
1 | GMK00061 | Deflector plate |
2 | GMK00062 | Bottom cover |
3 | 016-0014 | Food well, with drain |
4 | 932-1353 | Screw |
5 | 219-4007 | Element |
6 | 932-1379 | Screws (2) |
7 | 343-4663 | Insulation |
8 | 219-4335 | Thermostat non-adjustable |
9 | 932-1007 | Screw |
10 | GMK00063 | Drain cover |
11 | 932-1007 | Screws (2) |
12 | 219-4110 | Infinite control, 240V |
13 | 323-4557 | Infinite control knob |
14 | 219-4095 | Pilot light, amber |
NOTE: If you need four or more component parts, you must buy a complete assembly.
REPLACEMENT PARTS LIST
— NOT SHOWN ON EXPLODED VIEWS
DELFIELD …………………………………………………..DESCRIPTION
PART#
CR & CRR MODELS (MISC. PARTS)
Harness, wiring-female, 84” . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 218-3596
Glass, curved, 1”, insulated, 35” (537). . . . . . . . . . . . . . . . . . . .
. . . . . . . 345-5319
Glass, curved, 1”, insulated, 47” (549). . . . . . . . . . . . . . . . . . . .
. . . . . . . 345-5439
Glass, curved, 1”, insulated, 59” (561). . . . . . . . . . . . . . . . . . . .
. . . . . . . 345-5441
Glass, curved, 1”, insulated, 71” (573). . . . . . . . . . . . . . . . . . . .
. . . . . . . 345-5443
Foot, leveler, adj., 1/2-13 . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 323-4696
Fixture, fluorescent light, 24” remote, top light (537) . . . . . . . . . . .
. . . XMKOO131
Fixture, fluorescent light, 36” remote, top light (549) . . . . . . . . . . .
. . . XMKOO132
Fixture, fluorescent light, 48” remote, top light (561) . . . . . . . . . . .
. . . XMKOO133
Fixture, fluorescent light, 60” remote, top light (573) . . . . . . . . . . .
. . . XMKOO134
Louver, s/s, 15 x 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 001-5278
Louver, s/s, 15 x 23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 001-5279
Harness, light/fan motor, 78” . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 218-3414
Switch, 15A/120V, SPST, ivory . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 219-3919
Holder, adj. shelf, beige, RH . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 397-8121
Holder, adj. shelf, beige, LH . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 397-8120
Control, pressure, dual . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 219-3942
Bracket, fan motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 397-8070
Blade, fan, 7” dia., Lexan, clear . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 351-6184
Harness, evaporator fan . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 218-3445
Support, shelf, (549-CR) . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 001-5235
Shelf, top/end, adj., 21 x 22.5. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 397-8122
Shelf, bottom/end, adj., 26 x 22.5 . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . 397-8123
Door set, 49” disp. case, with lock . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 323-4697
Door set, 61” disp. case, with lock . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 323-4698
Shelf, top/center, adj., 21 x 12 . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 397-8125
Shelf, bottom/center, adj., 26 x 12 . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 397-8126
CD MODELS (MISC. PARTS)
Harness, wiring-female, 84” . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 218-3596
Glass, curved, .25”, insulated, 35” (537) . . . . . . . . . . . . . . . . . .
. . . . . . . 345-5400
Glass, curved, .25”, insulated, 47” (549) . . . . . . . . . . . . . . . . . .
. . . . . . . 345-5440
Glass, curved, .25”, insulated, 59” (561) . . . . . . . . . . . . . . . . . .
. . . . . . . 345-5442
Glass, curved, .25”, insulated, 71” (573) . . . . . . . . . . . . . . . . . .
. . . . . . . 345-5444
Fixture, fluorescent light, 24” remote, top light (537) . . . . . . . . . . .
. . . XMKOO131
Fixture, fluorescent light, 36” remote, top light (549) . . . . . . . . . . .
. . . XMKOO132
Fixture, fluorescent light, 48” remote, top light (561) . . . . . . . . . . .
. . . XMKOO133
Fixture, fluorescent light, 60” remote, top light (573) . . . . . . . . . . .
. . . XMKOO134
Foot, leveler, adj., 1/2-13 . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 323-4696
Switch, 15A/120V, (2) SPST, ivory . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . 219-3918
Holder, adj. shelf, beige, RH . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 397-8121
Holder, adj. shelf, beige, LH . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 397-8120
Pigtail, male, 9”, rem. ballast . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 218-3595
Support, shelf, (549) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 001-5235
Shelf, bottom/end, adj., 21 x 22.5 (549 & 561) . . . . . . . . . . . . . . . .
. . . . 397-8122
Shelf, adjustable, 21 x 33 (537) . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 397-8137
Shelf, top, center, adj. 21 x 24 (573) . . . . . . . . . . . . . . . . . . . .
. . . . . . . . 397-8127
Shelf, bottom/end, adj., 26 x 22.5 (549 & 561) . . . . . . . . . . . . . . . .
. . . . 397-8123
Shelf, adjustable, 26 x 33 (537) . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 397-8138
Shelf, bottom, center, adj. 26 x 24 (573) . . . . . . . . . . . . . . . . . .
. . . . . . . 397-8128
OR MODELS (MISC. PARTS)
Motor, evaporator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . 216-2667
Blade, fan, 7” dia., CW, 20 deg, alum . . . . . . . . . . . . . . . . . . . .
. . . . . . . . 351-6075
Harness, light/fan motor, 78’ . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 218-3414
Coil, evap., customer, 49”. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 351-6097
Cond. unit, 1/2 h.p., R-404A, med . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . 352-6731
Control, temperature, -30-100%D . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . 509-0025
Valve, Expansion, 1/4, R-404A . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 351-6273
Ballast, rapid start, 36” lamp . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 219-3903
Switch, 15A/120V, SPST, ivory . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 219-3919
Timer, 24 hours, clock face. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 219-4345
Harness, evaporator fan . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 218-3445
Bracket, fan motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 397-8070
Louver, s/s, 15 x 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 001-5278
Shelf, Lexan, .5” x 10” x 45.5” . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . 354-5339
Dial, Thermometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 351-6038
CH Models (misc. parts)
Lamp holder, twin-threaded . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 219-3960
Bulb, 25W, Teflon coating, clear . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 219-3959
Heater, pad, 115V/90W . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 219-3970
Thermostat, nonadjustable, 480°F . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . 219-4335
Thermometer/digital, solar/batt. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . 351-6059
Switch, rocker, 20A/125V, 15A/250V . . . . . . . . . . . . . . . . . . . . . .
. . . . . . 219-0154
Switch, 30A, 120/277V . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 219-4212
BALLASTS
120V ballast (537) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 219-3902
120V ballast (549) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 219-3903
120V ballast (561) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 219-3904
120V ballast (573) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . 219-3905
220V ballast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . special order
STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD
EQUIPMENT
Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage.
- A maximum of 1-hour is allowed to diagnose a defective component.
- A maximum of 1-hour is allowed for retrieval of parts not in stock.
- A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
- Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work Authorization from Delfield. You must submit the number with the service claim.
LABOR OF 1-HOUR IS ALLOWED TO REPLACE:
- Thermostat
- Infinite Switch
- Door Jamb Switch
- Solenoid Coil
- Hi-limit/Thermal Protector Switch
- Fan Delay/Defrost Termination Switch
- Compressor Start Components and Overload Protector
- Defrost Timer
- Thermometer
- Gear Box
- Contactor/Relay
- Transformer
- Evaporator/Condenser Fan Motor and Blade
- Circulating Fan Motor and Blade
- Microprocessor Control
- Water Level Sensor/Probe
- Door Hinges, Locks, and Gaskets
- Condensate Element
- Springs/Lowerator
LABOR OF 2 HOURS TO REPLACE:
- Drawer Tracks/Cartridges
- Pressure Control
- Solenoid Valve
- Defrost Element
- Heating Element
- Locate/Repair Leak
LABOR OF 3 HOURS TO REPLACE:
- EPR or CPR Valve
- Expansion Valve
- Condenser or Evaporator Coil
LABOR OF 4 HOURS TO REPLACE
• Compressor
This includes recovery of refrigerant and leak check.
$55.00 maximum reimbursement for refrigerant recovery (includes recovery
machine, pump, torch, oil, flux, minor fittings, solder, brazing rod,
nitrogen, or similar fees.)
REFRIGERANTS
- R22 A maximum of $4.00/lb. or 25¢/oz. will be reimbursed.
- R134A A maximum of $5.00/lb. or 31¢/oz. will be reimbursed.
- R404A A maximum of $15.00/lb. or $1.00/oz. will be reimbursed.
STANDARD ONE YEAR WARRANTY
(ONE YEAR PARTS, 90 DAYS LABOR.)
The Delfield Company (“Delfield”) warrants to the Original Purchaser of the
Delfield product (herein called the “Unit”) that such Unit, and all parts
thereof, will be free from defects in material and workmanship under normal
use and service for a period of one (1) year from the date of shipment of the
Unit to the Original Purchaser or, if the Original Purchaser returns the
warranty card completely filled out including the date of installation within
thirty (30) days of receipt of the Unit, one (1) year from the date of
installation. During this one year warranty period, Delfield will repair or
replace any defective part or portion there of returned to Delfield by the
Original Purchaser which Delfield determines was defective due to faulty
material or workmanship. The Original purchaser will pay all labor, crating,
freight and related costs incurred in the removal of the Unit of defective
component and shipment to Delfield, except that during a period of either
ninety (90) days from the date of shipment of the Unit to the Original
Purchaser or, if the Original Purchaser returns the warranty card completely
filled out including the date of installation within thirty (30) days of
receipt of the Unit, ninety (90) days from the date of installation Delfield
will pay all related labor costs. Delfield will pay the return costs if the
Unit or part thereof was defective.
The term “Original Purchaser” as used herein means that person, firm,
association, or corporation for whom the Unit was originally installed. This
warranty does not apply to any Unit or part thereof that has been subjected to
misuse, neglect, alteration, or accident, such as accidental damage to the
exterior finish, operated contrary to the recommendations specified by
Delfield; or repaired or altered by anyone other than Delfield in any way so
as to, in Delfield’s sole judgement, affect its quality or efficiency. This
warranty does not apply to any Unit that has been moved from the location
where it was originally installed. This warranty also does not cover the
refrigerator drier or the light bulbs used in the Unit. The warranty is
subject to the user’s normal maintenance and care responsibility as set forth
in the Service and Installation Manual, such as cleaning the condenser coil,
and is in lieu of all other obligations of Delfield. Delfield neither assumes,
nor authorizes any other person to assume for Delfield, any other liability in
connection with Delfield’s products.
Removal or defacement of the original Serial Number or Model Number from any
Unit shall be deemed to release Delfield from all obligations hereunder or any
other obligations, express or implied.
Parts furnished by suppliers to Delfield are guaranteed by Delfield only to
the extent of the original manufacturer’s express warranty to Delfield.
Failure of the Original Purchaser to receive such manufacturer’s express
warranty to Delfield. Failure of the Original Purchaser to receive such
manufacturers warranty shall in no way create any warranty, expressed or
implied, or any other obligation or liability on Delfield’s part in respect
thereof.
IF THE CUSTOMER IS USINg A PART THAT RESULTS IN A VOIDED WARRANTY AND A
DELFIELD AUTHORIZED REPRESENTATIVE TRAVELS TO THE INSTALLATION ADDRESS TO
PERFORM WARRANTY SERVICE, THE SERVICE REPRESENTATIVE WILL ADVISE CUSTOMER THE
WARRANTY IS VOID. SUCH SERVICE CALLS WILL BE BILLED TO CUSTOMER AT THE
AUTHORIZED SERVICE CENTER’S THEN APPLICABLE TIME AND MATERIALS RATES.
CONSIDER: CUSTOMER MAY INITIATE A SERVICE AgREEMENT WITHOUT PARTS COVERAgE.
If shipment of a replacement part is requested prior to the arrival in the
Delfield factory of the part claimed to be defective, the Original Purchaser
must accept delivery of the replacement part of a C.O.D. basis, with credit
being issued after the part has been received and inspected at Delfield’s
plant and determined by Delfield to be within this warranty.
Under no condition does this warranty give the Original Purchaser the right to
replace the defective Unit with a complete Unit of the same manufacturer or of
another make. Unless authorized by Delfield in writing, this warranty does not
permit the replacement of any part, including the motor-compressor, to be made
with the part of another make or manufacturer.
No claims can be made under this warranty for spoilage of any products for any
reason, including system failure. The installation contractor shall be
responsible for building access, entrance and field conditions to insure
sufficient clearance to allow any hood(s), vent(s), or Unit(s) if necessary,
to be brought into the building.
Delfield will not be responsible for structural changes or damages incurred
during installation of the Unit or any exhaust system. Delfield shall not be
liable in any manner for any default or delay in performance hereunder caused
by or resulting from any contingency beyond Delfield’s control, including, but
not limited to, war, governmental restrictions or restraints, strike,
lockouts, injunctions, fire, flood, acts of nature, short or reduced supply of
raw materials, or discontinuance of the parts by the original part
manufacturer.
Except as provided in any Additional Four Year Protection Plan, if applicable,
and the Service Labor Contract, if applicable, the foregoing is exclusive and
in lieu of all other warranties, whether written or oral, express or implied.
This warranty supersedes and excludes any prior oral or written
representations or warranties. Delfield expressly disclaims any implied
warranties of merchantability, fitness for a particular purpose of compliance
with any law, treaty, rule or regulation relating to the discharge of
substances into the environment. The sole and exclusive remedies of any person
relating to the Unit, and the full liability of Delfield for any breach of
this warranty, will be as provided in this warranty.
Other than this Delfield Standard One Year Limited Warranty, any applicable
Delfield Additional Four Year Protection Plan or applicable Delfield Service
Labor Contract, the Original Purchaser agrees and acknowledges that no other
warranties are offered or provided in connection with or for the unit or any
other part thereof.
In no event will Delfield be liable for special, incidental or consequential
damages, or for damages in the nature of penalties.
IF DURINg THE WARRANTY PERIOD, CUSTOMER USES A PART FOR THIS DELFIELD
EqUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY
FROM DELFIELD OR ANY OF ITS AUTHORIZED SERVICE CENTERS AND/OR THE PART BEING
USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID.
FURTHER, DELFIELD AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS DAMAGES
OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN
WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART
RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER. If the warranty becomes void,
Customer may purchase from Delfield, if available, a Service Agreement or
service at the then current time and materials rate.
For more information on Delfield warranty’s log on and check out the service
section of our web site at www.delfield.com.
ADDITIONAL FOUR YEAR PROTECTION PLAN
(FOR MOTOR-COMPRESSOR ONLY)
Delfield Model#
Serial #
Installation Date
In addition to the Standard One Year Warranty on the MotorCompressor contained
in the above listed Delfield product (the “Unit”), The Delfield Company
(“Delfield”) also agrees to repair, or exchange with similar or
interchangeable parts in design and capacity at Delfield’s option, the
defective Motor-Compressor contained in the Unit (the “Motor-Compressor), or
any part thereof, for the Original Purchaser only, at any time during the four
(4) years following the initial one (1) year period commencing on the date of
installation for the Original Purchaser. Failure of the Original Purchaser to
register the registration card containing the Original Purchasers name,
address, date of installation, model number and serial number of the Unit
containing the Motor-Compressor within 30 days from the date of installation
shall void this warranty. This additional warranty is only available if the
Motor-Compressor is inoperative due to defects in material or factory
workmanship, as determined by Delfield in its sole judgement and discretion.
The Original Purchaser shall be responsible for returning the defective Motor-
Compressor to Delfield prepaid, F.O.B. at the address shown on the back cover
of this manual.
The term “Original Purchaser” as used herein means that person, firm,
association, or corporation for whom the Unit was originally installed.
The term “Motor-Compressor” as used herein does not include unit base, air or
water cooled condenser, receiver, electrical accessories such as relay,
capacitors, refrigerant controls, or condenser fan/motor assembly. This
warranty does not cover labor charges incidental to the replacement of parts.
This warranty further does not include any equipment to which said condensing
unit is connected, such as cooling coils, temperature controls or refrigerant
metering devices. This warranty shall be void if the Motor-Compressor, in
Delfield’s sole judgement, has been subjected to misuse, neglect, alteration
or accident, operated contrary to the recommendations specified by the Unit
manufacturer, repaired or altered by anyone other than Delfield in any way so
as, in Delfield’s sole judgment, to affect its quality or efficiency or if the
serial number has been altered, defaced or removed. This Warranty does not
apply to a Motor-Compressor in any Unit that has been moved from the location
where it was originally installed. The addition of methyl chloride to the
condensing unit or refrigeration system shall void this warranty.
General Conditions
Delfield shall not be liable in any manner for any default or delay in
performance hereunder caused by or resulting from any contingency beyond
Delfield’s control, including, but not limited to, war, governmental
restrictions or restraints, strike, lockouts, injunctions, fire, flood, acts
of nature, short or reduced supply of raw materials, or discontinuance of any
part or the MotorCompressor by the unit manufacturer.
Replacement of a defective Motor-Compressor is limited to one (1) Motor-
Compressor by us during the four (4) year period. Delfield shall replace the
Motor-Compressor at no charge.
This warranty does not give the Original Purchaser of the MotorCompressor the
right to purchase a complete replacement MotorCompressor of the same make or
of another make. It further does not permit the replacement to be made with a
Motor-Compressor of another kind unless authorized by Delfield. In the event
Delfield authorizes the Original Purchaser to purchase a replacement Motor-
Compressor locally, only the wholesale cost of the MotorCompressor is
refundable.
Expressly excluded from this warranty are damages resulting from spoilage of
goods.
Except as provided in any applicable Standard One Year Limited Warranty or
applicable Service Labor Contract, the foregoing is exclusive and in lieu of
all other warranties, whether written or oral, express or implied. This
Warranty supersedes and excludes any prior oral or written representations or
warranties. Delfield expressly disclaims any implied warranties of
merchantability, fitness for a particular purpose or compliance with any law,
treaty, rule or regulation relating to the MotorCompressor, and the full
liability of Delfield for any breach of this warranty, will be as provided in
this warranty.
Other than any applicable Delfield Standard One year Limited Warranty, this
Delfield Additional Four Year Protection Plan and any applicable Delfield
Service Labor Contract, the Original Purchaser agrees and acknowledges that no
other warranties are offered or provided in connection with or for the Motor-
Compressor or any part thereof.
In no event will Delfield be liable for special, incidental or consequential
damages, or for damages in the nature of penalties.
Thank you for choosing Delfield!
Help is a phone call away. Help our team of professional, courteous customer
service reps by having your model number and serial number available at the
time of your call 800-733-8829.
Model: ____ S/N: ___
Installation Date: ____
For a list of Delfield’s authorized parts depots, visit our website at www.delfield.com.
980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A. •
989-773-7981 or
800-733-8829 • Fax
989-773-3210 •
www.delfield.com
Delfield reserves the right to make changes in design or specifications
without prior notice.
©2010 The Delfield Company. All rights reserved. Printed in the U.S.A.
DM500 04/10
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>