Delfield F18 Series Refrigerated Work Tables Salad Tables and Freezer Bases Instruction Manual
- June 13, 2024
- DELFIELD
Table of Contents
- F18 Series Refrigerated Work Tables Salad Tables and Freezer Bases
- Important Warning And Safety Information
- Receiving and Inspecting the Equipment
- Warranty Information
- Specifications
- Installation
- Refrigerator Operation
- Temperature Control Settings
- Maintenance
- Replacement Parts
- Replacement Part Assemblies
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
F18 Series Refrigerated Work Tables Salad Tables and Freezer
Bases
Instruction Manual
F18 Series Refrigerated Work Tables Salad Tables and Freezer Bases
Service and Installation Manual
Please read this manual completely before attempting to install or operate
this equipment! Notify carrier of damage! Inspect all components
immediately.Refrigerated Work Tables, Salad Tables & Freezer Bases
Important Information Read Before Use Please Save These Instructions!
Important Warning And Safety Information
WARNING
Read This Manual Thoroughly Before Operating, Installing, Or Performing
Maintenance On The Equipment.
WARNING
Failure To Follow Instructions In This Manual Can Cause Property Damage,
Injury Or Death.
WARNING
Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids In The
Vicinity Of This Or Any Other Appliance.
WARNING
Unless All Cover And Access Panels Are In Place And Properly Secured, Do Not
Operate This Equipment.
WARNING
This Appliance Is Not Intended For Use By Persons Who Lack Experience Or
Knowledge, Unless They Have Been Given Supervision Or Instruction Concerning
Use Of The Appliance By A Person Responsible For Their Safety.
WARNING
This Appliance Is Not To Be Played With.
WARNING
Do Not Clean With Water Jet.
WARNING
Do Not Use Electrical Appliances Inside The Food Storage Compartment Of This
Appliance.
CAUTION
Observe the following:
- Minimum clearances must be maintained from all walls and combustible materials.
- Keep the equipment area free and clear of combustible material.
- Allow adequate clearance for air openings.
- Operate equipment only on the type of electricity indicated on the specification plate.
- Unplug the unit before making any repairs.
- Retain this manual for future reference.
Receiving and Inspecting the Equipment
Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building.
- Visually inspect the exterior of the package an skid or container. Any damage should be noted and reported to the delivering carrier immediately.
- If damaged, open and inspect the contents with the carrier.
- In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier. Notification should be made verbally as well as in written form.
- Request an inspection of the concealed equipment. This should be done within 10 days from receipt of the equipment.
- Check the lower portion of the unit to be sure legs or casters are not bent.
- Also open the compressor compartment housing and
Uncrating the Equipment
First cut and remove the banding from around the crate. Remove the front of
the crate material, use of some tools will be required. If the unit is on legs
remove the top of the crate as well and lift the unit off the skid. If the
unit is on casters it can be “rolled” off the skid.
Serial Number Location
The serial number on all self-contained F18 Series refrigerated work tables
and freezer bases is located on the electrical specifications tag affixed
inside the compressor section next to the pressure control.
On remote refrigerated bases with doors, the tag is inside the unit on the
coil side. On remote refrigerated bases with drawers, the tag is affixed to
the drawer divider. On remote freezer bases, the tag is located on the inside
back of the unit.
Always have the serial number of your unit available when calling for parts or
service. A complete list of authorized Delafield parts depots is available at
www.delfield.com.
©2013 The Delafield Company. All rights reserved. Reproduction without written
permission is prohibited. “Delafield” is a registered trademark of The
Delafield Company.
Warranty Information
Visit http://www.delfield.com/minisite/service/warranty_info to:
- Register your product for warranty.
- Verify warranty information.
- View and download a copy of your warranty.
Regulatory Certifications
Models are certified by:
National Sanitation Foundation (NSF)
Underwriters Laboratories (UL) Underwriters Laboratories of Canada (ULC)
Specifications
Remote Refrigerated Work Tables
**Model| ****# Of Doors| Shelf Max Base Volume Load (lbs)
FT3| Shelf Area FT2| Volts/Hertz/ Phase|
****Amps| ****BTU Load| ****EVAP. BTU/°TD
---|---|---|---|---|---|---|---
F18WR31| (1) 19”| 70| 7.56| 2.56| 115/60/1| 3.0| 383| 120/3°
F18WR39| (1) 27”| 124| 10.23| 3.95| 115/60/1| 3.0| 465| 120/4°
F18WR44| (2) 19”| 70| 12.14| 5.12| 115/60/1| 3.0| 605| 120/5°
F18WR52| (1) 19” & (1) 27”| 70/124| 15.12| 6.51| 115/60/1| 3.0| 686|
120/6°
F18WR60| (2) 27”| 124| 18.10| 7.90| 115/60/1| 3.0| 768| 120/6°
F18WR70| (2) 32”| 140| 21.23| 9.64| 115/60/1| 3.0| 869| 120/7°
F18WR79| (2) 27” & (1) 19”| 124/70| 24.48| 10.29| 115/60/1| 6.0| 1050|
240/4°
F18WR87**| (3) 27”| 124| 27.46| 11.85| 115/60/1| 6.0| 1131| 240/5°
Self-Contained Refrigerated Work Tables
**Model| ****# Of Doors| Shelf Max Base
Volume Load
(lbs) FT3| Shelf Area FT2| Volts/Hertz/ Phase|
****Amps| ****BTU Load| ****BTU System Cap.| R-404A
oz.| ****H.P.| NEMA Plug
---|---|---|---|---|---|---|---|---|---|---
F18WC39| (1) 19”| 70| 7.56| 2.56| 115/60/1| 8.0| 383| 1462| 16| 1/5|
5-15P
F18WC47| (1) 27”| 124| 10.23| 3.95| 115/60/1| 8.0| 465| 1462| 16| 1/5|
5-15P
F18WC52| (2) 19”| 70| 12.14| 5.12| 115/60/1| 8.0| 605| 1462| 16| 1/5|
5-15P
F18WC60| (1) 19” & (1) 27”| 70/124| 15.12| 6.51| 115/60/1| 8.0| 686|
1462| 16| 1/5| 5-15P
F18WC68| (2) 27”| 124| 18.10| 7.90| 115/60/1| 10.0| 768| 1462| 16| 1/4|
5-15P
F18WC78| (2) 32”| 140| 21.23| 9.64| 115/60/1| 10.0| 869| 1994| 16| 1/4|
5-15P
F18WC87| (2) 27” & (1) 19”| 124/70| 24.48| 10.29| 115/60/1| 10.0| 1050|
2261| 16| 1/4| 5-15P
F18WC95**| (3) 27”| 124| 27.46| 11.85| 115/60/1| 10.0| 1131| 2261| 16|
1/4| 5-15P
Remote Refrigerated Mega Top Salad Tables
**Model| ****# Of Doors| Shelf Max Base Volume Load (lbs)
FT3| ****# of Pans| Volts/Hertz/ Phase| ****Amps|
BTU Load Base/Rail| EVAP. BTU/°TD Base/Rail
---|---|---|---|---|---|---|---
F18MR31A| (1) 19”| 70| 4.14| 6| 115/60/1| 3.0| 280/265| 120/2°/12/22°
F18MR44A| (2) 19”| 70| 7.15| 6| 115/60/1| 3.0| 444/265| 120/4°/12/22°
F18MR44D| (2) 19”| 70| 7.15| 12| 115/60/1| 3.0| 444/529| 120/4°/22/25°
F18MR52A| (1) 19” & (1) 27”| 70/124| 8.97| 6| 115/60/1| 3.0| 515/265|
120/4°/12/22°
F18MR52D| (1) 19” & (1) 27”| 70/124| 8.97| 12| 115/60/1| 3.0| 515/529|
120/4°/22/25°
F18MR52E**| (1) 19” & (1) 27”| 70/124| 8.97| 18| 115/60/1| 3.0| 515/794|
120/4°/31/26°
Self-Contained Refrigerated Mega Top Salad Tables
**Model| ****# Of Doors| Shelf Max Base Volume Load (lbs)
FT3| # of Pans| Volts/Hertz/ Phase| ****Amps| BTU
Load Base/Rail| BTU System Cap. R-404A Base/Rail oz.|
****H.P.| NEMA Plug
---|---|---|---|---|---|---|---|---|---
F18MC39A| (1) 19”| 70| 4.14| 6| 115/60/1| 10.0| 280/265| 1903/925| 16|
1/4| 5-15P
F18MC39D| (1) 19”| 70| 4.14| 12| 115/60/1| 10.0| 280/529| 1903/1156| 16|
1/4| 5-15P
F18MC52A| (2) 19”| 70| 7.15| 6| 115/60/1| 10.0| 444/265| 1903/925| 16|
1/4| 5-15P
F18MC52D| (2) 19”| 70| 7.15| 12| 115/60/1| 10.0| 444/529| 1903/1156| 16|
1/4| 5-15P
F18MC52E| (2) 19”| 70| 7.15| 18| 115/60/1| 10.0| 444/794| 1903/1321| 16|
1/4| 5-15P
F18MC60A| (1) 19” & (1) 27”| 70/124| 8.97| 6| 115/60/1| 10.0| 515/265|
2314/864| 16| 1/4| 5-15P
F18MC60D| (1) 19” & (1) 27”| 70/124| 8.97| 12| 115/60/1| 10.0| 515/529|
2314/1141| 16| 1/4| 5-15P
F18MC60E| (1) 19” & (1) 27”| 70/124| 8.97| 18| 115/60/1| 10.0| 515/794|
2314/1361| 16| 1/4| 5-15P
F18MC60F**| (1) 19” & (1) 27”| 70/124| 8.97| 24| 115/60/1| 10.0| 515/1058|
2314/1540| 16| 1/4| 5-15P
Remote Refrigerated Salad Top Tables
**Model| ****# Of Doors| Shelf Max
Load (lbs)| Base Volume FT3| # of Pans|
Volts/Hertz/ Phase| ****Amps| BTU Load Base/Rail|
Evap. BTU/°TD Base/Rail
---|---|---|---|---|---|---|---|---
F18SR31A| (1) 19”| 70| 4.14| 6| 115/60/1| 3.0| 280/265| 120/2°/13/21°
F18SR44A| (2) 19”| 70| 7.15| 6| 115/60/1| 3.0| 491/441| 120/4°/13/21°
F18SR44B| (2) 19”| 70| 7.15| 8| 115/60/1| 3.0| 491/441| 120/4°/16/22°
F18SR44C| (2) 19”| 70| 7.15| 10| 115/60/1| 3.0| 491/441| 120/4°/19/23°
F18SR52A| (1) 19” & (1) 27”| 70/124| 8.97| 6| 115/60/1| 3.0| 532/529|
120/4°/13/21°
F18SR52B| (1) 19” & (1) 27”| 70/124| 8.97| 8| 115/60/1| 3.0| 532/529|
120/4°/16/22°
F18SR52C| (1) 19” & (1) 27”| 70/124| 8.97| 10| 115/60/1| 3.0| 532/529|
120/4°/19/23°
F18SR52D**| (1) 19” & (1) 27”| 70/124| 8.97| 12| 115/60/1| 3.0| 532/529|
120/4°/23/23°
Self-Contained Refrigerated Salad Top Tables
**Model| ****# Of Doors| Shelf Max Base Volume Load
(lbs) FT3| # of Pans| Volts/Hertz/ Phase|
****Amps| BTU Load
Base/Rail| BTU System Cap. Base/Rail| R-404A oz.|
****H.P.| NEMA Plug
---|---|---|---|---|---|---|---|---|---|---
F18SC39A| (1) 19”| 70| 4.14| 6| 115/60/1| 10.0| 280/265| 1903/745| 16|
1/4| 5-15P
F18SC39B| (1) 19”| 70| 4.14| 8| 115/60/1| 10.0| 280/353| 1903/867| 16|
1/4| 5-15P
F18SC52A| (2) 19”| 70| 7.15| 6| 115/60/1| 10.0| 444/265| 1903/745| 16|
1/4| 5-15P
F18SC52B| (2) 19”| 70| 7.15| 8| 115/60/1| 10.0| 444/353| 1903/867| 16|
1/4| 5-15P
F18SC52C| (2) 19”| 70| 7.15| 10| 115/60/1| 10.0| 444/441| 1903/971| 16|
1/4| 5-15P
F18SC52D| (2) 19”| 70| 7.15| 12| 115/60/1| 10.0| 444/529| 1903/1061| 16|
1/4| 5-15P
F18SC60A| (1) 19” & (1) 27”| 70/124| 8.97| 6| 115/60/1| 10.0| 515/265|
2314/667| 16| 1/4| 5-15P
F18SC60B| (1) 19” & (1) 27”| 70/124| 8.97| 8| 115/60/1| 10.0| 515/353|
2314/798| 16| 1/4| 5-15P
F18SC60C| (1) 19” & (1) 27”| 70/124| 8.97| 10| 115/60/1| 10.0| 515/441|
2314/916| 16| 1/4| 5-15P
F18SC60D**| (1) 19” & (1) 27”| 70/124| 8.97| 12| 115/60/1| 10.0| 515/529|
2314/1023| 16| 1/4| 5-15P
Remote Refrigerated Reduced Height Rail
**Model| ****# Of Doors| Shelf Max Load (lbs)| Base
Volume FT3| Shelf Area FT2| # of Pans|
Volts/Hertz/ Phase| ****Amps| BTU Load Base/Rail|
Evap. BTU/°TD Base/Rail
---|---|---|---|---|---|---|---|---|---
F18DR44| (2) 19”| 70| 9.54| 5.12| 10| 115/60/1| 3.0| 547/441|
120/5°/19/23°
F18DR52| (1) 19” & (1) 27”| 70/124| 13.89| 6.51| 12| 115/60/1| 3.0|
625/529| 120/5°/23/23°
F18DR60| (2) 27”| 124| 16.64| 7.9| 16| 115/60/1| 5.0| 703/617|
120/6°/26/24°
F18DR70| (2) 32”| 140| 22.96| 9.64| 18| 115/60/1| 5.0| 800/794|
120/7°/32/24°
F18DR79| (1) 19” & (2) 27”| 70/124| 22.47| 10.29| 18| 115/60/1| 5.0|
962/882| 240/4°/36/25°
F18DR87**| (3) 27”| 124| 25.22| 11.85| 22| 115/60/1| 5.0| 1032/970|
240/4°/39/25°
Self-Contained Refrigerated Reduced Height Rail
**Model| ****# Of Doors| Shelf Max Base Volume Load
(lbs) FT3| Shelf Area FT2| # of Pans|
Volts/Hertz/ Phase| ****Amps| BTU Load Base/Rail|
BTU System Cap. Base/Rail| R-404A oz.| ****H.P.| NEMA
Plug
---|---|---|---|---|---|---|---|---|---|---|---
F18DC52| (2) 19”| 70| 9.54| 5.12| 12| 115/60/1| 10.0| 547/529|
1903/1061| 16| 1/4| 5-15P
F18DC60| (1) 19” & (1) 27”| 70/124| 13.89| 6.51| 14| 115/60/1| 12.0|
625/617| 2314/1121| 24| 1/3| 5-15P
F18DC68| (2) 27”| 124| 16.64| 7.9| 18| 115/60/1| 12.0| 703/794|
2314/1544| 24| 1/3| 5-15P
F18DC82| (2) 32”| 140| 22.96| 9.64| 20| 115/60/1| 14.0| 800/882|
3097/1648| 32| 1/2| 5-20P
F18DC91| (1) 19” & (2) 27”| 70/124| 22.47| 10.29| 22| 115/60/1| 14.0|
962/1058| 3807/1839| 32| 1/2| 5-20P
F18DC99**| (3) 27”| 124| 25.22| 11.85| 24| 115/60/1| 14.0| 1032/1147|
3807/1839| 32| 1/2| 5-20P
Remote Refrigerated Reduced Height Rail
**Model| ****# Of Doors| Shelf Max Load (lbs)| Base
Volume FT3| Shelf Area FT2| Volts/Hertz/ Phase|
****Amps| BTU Load Base/Rail| Evap. BTU/°TD
Base/Rail| # of Pans
---|---|---|---|---|---|---|---|---|---
F18RR44| (2) 19”| 70| 9.49| 5.12| 115/60/1| 3.0| 547/441| 120/5°/19/23°|
10
F18RR52| (1) 19” & (1) 27”| 70/124| 11.81| 6.51| 115/60/1| 3.0| 625/529|
120/5°/23/23°| 12
F18RR60| (2) 27”| 124| 14.14| 7.9| 115/60/1| 5.0| 703/617|
120/6°/26/24°| 16
F18RR70| (2) 32”| 140| 17.05| 9.64| 115/60/1| 5.0| 800/794|
120/7°/32/24°| 18
F18RR79| (1) 19” & (2) 27”| 70/124| 18.68| 10.29| 115/60/1| 5.0|
962/882| 240/4°/36/25°| 18
F18RR87**| (3) 27”| 124| 21.30| 11.85| 115/60/1| 5.0| 1032/970|
240/4°/39/25°| 22
Self-Contained Refrigerated Reduced Height Rail
**Model| ****# Of Doors| Shelf Max Base Volume Load (lbs)
FT3| Shelf
Area FT2| Volts/Hertz/ Phase| ****Amps| BTU
Load Base/Rail| BTU System Cap. Base/Rail| # of Pans|
R-404A oz.| ****H.P.| NEMA Plug
---|---|---|---|---|---|---|---|---|---|---|---
F18RC52| (2) 19”| 70| 9.49| 5.12| 115/60/1| 10.0| 547/529| 1903/1061|
12| 16| 1/4| 5-15P
F18RC60| (1) 19” & (1) 27”| 70/124| 11.81| 6.51| 115/60/1| 12.0|
625/617| 2314/1121| 14| 24| 1/3| 5-15P
F18RC68| (2) 27”| 124| 14.14| 7.9| 115/60/1| 12.0| 703/794| 2314/1544|
16| 24| 1/3| 5-15P
F18RC82| (2) 32”| 140| 17.05| 9.64| 115/60/1| 14.0| 800/882| 3097/1648|
20| 32| 1/2| 5-20P
F18RC91| (1) 19” & (2) 27”| 70/124| 18.68| 10.29| 115/60/1| 14.0|
962/1058| 3807/1839| 22| 32| 1/2| 5-20P
F18RC99**| (3) 27”| 124| 21.30| 11.85| 115/60/1| 14.0| 1032/1147|
3807/1839| 24| 32| 1/2| 5-20P
Remote Freezer Base
**Model| ****# Of Doors| Shelf Max
Load (lbs)| Base Volume FT3| Shelf Area FT2|
Volts/Hertz/ Phase| ****Amps| BTU Load Base/Rail|
****Evap. BTU/°TD
---|---|---|---|---|---|---|---|---
F18FR35| (1) 19”| 70| 5.58| 2.56| 115/60/1| 10.0| 943| 160/6°
F18FR50| (2) 19”| 70| 12.21| 5.12| 115/60/1| 10.0| 1471| 160/9°
F18FR58| (1) 19” & (1) 27”| 70/124| 15.00| 6.51| 115/60/1| 10.0| 1844|
160/10°
F18FR66| (2) 27”| 124| 17.79| 7.9| 115/60/1| 10.0| 2020| 160/11°
F18FR76**| (2) 32”| 140| 21.28| 9.64| 115/60/1| 10.0| 2437| 160/13°
Self-Contained Freezer Base
**Model| ****# Of Doors| Shelf Max Base Volume Load (lbs)
FT3| Shelf Area FT2| Volts/Hertz/ Phase|
****Amps| BTU Load Base/Rail| BTU System Cap. Base/Rail|
****H.P.| R-404A oz.| NEMA Plug
---|---|---|---|---|---|---|---|---|---|---
F18FC43| (1) 19”| 70| 5.58| 2.56| 115/60/1| 10.0| 943| 1558| 1/3| 24|
5-15P
F18FC62| (2) 19”| 70| 12.21| 5.12| 115/60/1| 12.0| 1471| 1776| 1/2| 40|
5-15P
F18FC70| (1) 19” & (1) 27”| 70/124| 15.00| 6.51| 115/60/1| 16.0| 1647|
2713| 3/4| 56| 5-20P
F18FC78| (2) 27”| 124| 17.79| 7.9| 115/60/1| 16.0| 1824| 2713| 3/4| 56|
5-20P
F18FC88**| (2) 32”| 140| 21.28| 9.64| 115/60/1| 16.0| 2045| 2713| 3/4| 56|
5-20P
**Self-Contained Dual Rails**
**Model| ****# Of Doors| Shelf Max Base Volume Load (lbs)
FT3| Shelf Area FT2| Volts/Hertz/ Phase|
****Amps| BTU Load Base/Rail| BTU System Cap. Base/Rail|
****H.P.| R-404A Neoma. Plug
---|---|---|---|---|---|---|---|---|---
F18PD48| (1) 27”| 124| 9.38| 3.95| 115/60/1| 10.0| 424/1058| 2001/1865|
1/5, 1/3| 40| 5-20P
F18PD72**| (2) 27”| 124| 16.64| 7.90| 115/60/1| 12.7| 703/1588| 2001/3174|
1/5. 1/2| 48| 5-20P
Installation
Location
These units are intended for indoor use only. Be sure the location chosen has
a floor strong enough to support the total weight of the cabinet and contents.
A fully loaded 72” (183cm) long model may weigh as much as 1500 pounds
(680kg)! Reinforce the floor as necessary to provide for maximum loading. It
is very important to allow for proper air flow, both inside and outside. Avoid
hot corners and locations near stoves, ovens and other pieces of cooking
equipment.
Note
It is recommended that the unit be installed no closer than 1” (2.54cm) from
any wall. Do not install the unit near any combustible material or object
affected by heat or moisture.
PDL models also require 14″ (36cm) clearance at the top and 6″ (15cm)
clearance at the bottom (casters).
Leveling
A level cabinet looks better and will perform better because the drain pan
will drain properly, the doors will line up with the frames properly, and the
cabinet will not be subject to undue strain.
A unit on legs will have an adjustable bullet foot on each leg, adjust each
for a level unit. A unit on casters will not be adjustable. Be sure the unit
is on a level floor, make necessary changes to the floor for proper level.
Lock all front casters to ensure the stability of the unit.
Plumbing
Self-contained models are standard with a condensate evaporator. If, for some
reason a unit does not have a condensate evaporator, or if the evaporator
fails, the unit’s drain must have an outlet to an appropriate drainage area or
container. A refrigerated rail will have a 1″ (2.54cm) drain which will need
to be run to an appropriate floor drain or container. The drain will be
stubbed to the bottom of the machine compartment. Either run drain to a floor
drain or add a valve to the base of the machine compartment and drain the rail
to a container when convenient. The Liquate option will NOT have a drain
available.
** Moisture collecting from improper drainage can create a slippery surface
on the floor and a hazard to employees. It is the owner’s responsibility to
provide a container or outlet for drainage.
Electrical connection
** Refer to the specification pages amperage data, the serial tag, your local
code or the National Electrical Code to be sure the unit is connected to the
proper power source. A protected circuit of the correct voltage and amperage
must be run for connection of the line cord, or permanent connection of the
unit. Self-contained units with a cord and plug have an ON/OFF switch located
directly behind the louvered panel covering the compressor section. Simply
turn the switch to ON to begin operation.
The power switch must be turned to OFF and the unit disconnected from the
power source whenever performing service or maintenance functions.
Never operate the unit without the louvered panel in place!
If electrical receptacles are to be mounted in the unit’s backsplash, they
must be wired independently from the existing unit wiring.
Refrigerator Operation
Power up the unit by turning ON the unit’s ON/OFF switch. Delafield
refrigerated bases are designed to maintain an operational temperature of 36°F
to 40°F (2°C to 4°C). Temperature in the salad top and refrigerated rail
opening is 33°F to 41°F (0°C to 5°C) with pans recessed 2” (5.1cm) on a
standard wrapped refrigerated rail or flush with the Liquate option at 86°F
(30°C) ambient room temperature.
Note Do not place hot pans on/against the blue ABS liner. Do not throw
items into the storage area. Failure to heed these recommendations could
result in damage to the interior of the cabinet or to the blower coil.
Note Overloading the storage area, restricting the air flow, and
continuous opening and closing of the doors and drawers will hamper the units
ability to maintain operational temperature.
Refrigerated rail units
Product in the rail should be removed to the refrigerated base at the end of
the day. This allows you to turn the rail off at night to save energy and the
rail will have time to defrost as needed. It also helps maintain product
quality. The standard wrapped refrigerated units are controlled by the
pressure control which is set to maintain the proper rail temperature. An
on/off switch is also provided for the rail and is required to be shut off at
night. The rail switch shuts off the rail only. With a Liquate rail a
thermostat is provided to maintain rail temperature as well as the rail on/off
switch. The Liquate rail is required to be shut off at night as well to allow
for defrosting. To ensure product quality in the rail it is recommended that
product be rotated every four hours.
If adding any item to the unit, be sure to keep in mind the location of the
refrigeration lines on wrapped rail units. A refrigeration leak in a rail is
extremely difficult and costly to repair. In some cases it cannot be repaired
at all.
Refrigerator Evaporator Fan Operation
When the refrigerator is initially powered up or immediately following a power
outage the unit will begin cooling after a 3-6 minute delay. During normal
operation the evaporator fan pulses independently of the compressor as
dictated by the controller as follows:
- During the cooling mode, compressor and evaporator fan run simultaneously.
- During the compressor off mode, evaporator fan pulses three minutes on and three minutes off.
- During an actual defrost event other than the off-cycle defrost, compressor stays off but the evaporator fan runs continuously.
Cooling Cycle | Defrost Cycle |
---|---|
Compressor On | Compressor Off |
Evap Fan On | Evap Fan Off |
Off
X| | Cycles On 3-Min, Off 3-Min| X|
Freezer Operation
Power up the unit by turning ON the unit’s ON/Footswitch. Delafield freezer
bases are designed to maintain an operational temperature of 0°F (-18°C).
Note Do not place hot pans on/against the blue ABS liner. Do not throw
items into the storage area. Failure to heed these recommendations could
result in damage to the interior of the cabinet or to the blower coil.
Note Overloading the storage area, restricting the air flow, and
continuous opening and closing of the doors and drawers will hamper the units
ability to maintain operational temperature.
Freezer Evaporator Fan Operation
The evaporator fan(s) and condenser fan will cycle off and on with the
compressor to conserve energy. The temperature control will cycle the
compressor and condenser fan motor and evaporator fan motor to maintain box
temperature at the control setting.
Cooling Cycle | Defrost Cycle |
---|---|
All Freezers | Self-Contained Freezers |
Compressor On | Compressor Off |
Evap Fan On | Evap Fan Off |
Freezer Defrost
Self-contained models use hot gas to defrost the evaporator coils. Remote
freezers use electric defrost.
Temperature Control Settings
A thermostat controls temperature in the self-contained F18WC, F18FC, F18MC
base, F18SC base, F18RC base, F18DC base, F18PD base and F18PD rails.
Thermostats are located in the machine compartment. They are field adjustable
and do not require a service agent. The factory setting is 2.5. Set toward 1
for higher temperatures and toward 7 for lower temperatures.
A thermostat controls temperature in the remote F18FR. The temperature control
is located in the machine compartment. It is field adjustable and does not
require a service agent. The factory setting for a remote freezer is 0°F cut-
in with a 5°F differential.
Note Please make small incremental adjustments if a temperature
adjustment is necessary. It may take an hour or longer to realize the
temperature change depending on the application and location of the unit.
Contact the service department at Delfield +1z
989-773-7981 or your local service
agent for additional assistance. Delfield is not responsible for charges
incurred while adjusting the thermostat.
Pressure Control Settings
A pressure control controls temperature in the F18MC mega top, F18SC salad
top, F18RC rail and F18DC rail. The factory recommended low-pressure control
settings are: 55psi cut-in and 30psi cut-out to maintain proper temperature
for product. The interior temperature is controlled by the thermostat mounted
in the mechanical compartment.
A pressure control is located in the machine compartment. An adjustable
control has the word COLDER on the knob, with an arrow to indicate the
adjustment direction. These controls are field adjustable and do not require a
service agent.
Note In attempting to adjust the pressure control, you can do damage to
your unit by accidentally adjusting the differential. Please make small
incremental adjustments if a temperature adjustment is necessary. It may take
an hour or longer to realize the temperature change depending on the
application and location of the unit.
Please contact the service department at Delfield
800-733-8829 or your local service
agent. Delfield is not responsible for charges incurred while having the
pressure control adjusted.
Maintenance
Door Gasket Maintenance
Door gaskets require regular cleaning to prevent mold and mildew build up and
also to retain the elasticity of the gasket. Gasket cleaning can be done with
the use of warm soapy water. Avoid full strength cleaning products on gaskets
as this can cause them to become brittle and crack. Never use sharp tools or
knives to scrape or clean the gasket. Gaskets can be easily replaced and do
not require the use of tools or an authorized service person. The gaskets are
“Dart” style and can be pulled out of the groove in the door and new gaskets
can be “pressed” back into place.
Drain Maintenance – Base
Each unit has a drain located inside the unit that removes the condensation
from the evaporator coil and routes it to an external condensate evaporator
pan. Each drain can become loose or disconnected during normal use. If you
notice water accumulation on the inside of the unit be sure the drain tube is
connected to the evaporator drain pan. If water is collecting underneath the
unit make sure the end of the drain tube is in the condensate evaporator in
the machine compartment. The leveling of the unit is important as the units
are designed to drain properly when level. Be sure all drain lines are free of
obstructions.
Drawer Maintenance
Drawer Assembly Cleaning
The drawer assembly is designed to be cleaned easily. Both drawer and tracks
are removable without tools. The drawer tracks are dishwasher safe or can be
cleaned in a sink with detergents and a soft bristle brush. Drawers and tracks
should be cleaned on a weekly basis.
Remove Drawers
Pull the drawer box out until it stops. Lift up on the drawer front and pull
the drawer box completely out. Using a soft bristle brush, clean the track on
the bottom of the drawer box. When finished, it should be wiped clean of all
food and debris.
Tracks
The drawer box assembly must be removed. Pull the drawer tracks out until they
hit a stop. Locate blue safety clips towards the back of each drawer track.
Blue safety clips have a tab on the top. Push the tab back until it clicks.
Lift up and pull the drawer tracks all the way out of the drawer cage. The
drawer tracks are dishwasher safe or can be cleaned in a sink with detergents
and a soft bristle brush. Drawers and tracks should be cleaned on a weekly
basis. Using a soft bristle brush, wash the track making sure each roller is
thoroughly cleaned. The drawer cage should be cleaned with a soft bristle
brush, removing any food and debris gathered on the bottom ledge. Once it’s
cleaned thoroughly with a soft bristle brush, wipe remaining debris clean with
a soft towel. Reassembly
Push the drawer tracks into the drawer cage. The blue safety clip must remain
pushed towards the back. Lift up and slide the drawer track all the way into
the drawer cage. The blue safety clip will lock in place automatically. Once
all tracks are replaced, insert the drawer box. Rest the drawer box bottom
track on the front track roller. Then push the drawer back in place SLOWLY.
When the drawer box is about half way in you will hit a STOP. You must lift
the front of the drawer up approximately ½” (1.3cm) to continue inward. Clean
tracks as often as possible. The cleaner the tracks are the better they will
operate.
Caster Maintenance
Note Wipe casters with a damp cloth monthly to prevent corrosion. The
power switch must be turned to OFF and the unit disconnected from the power
source whenever performing service, maintenance functions or cleaning the
refrigerated area.
Refrigerators and Freezers
The interior and exterior can be cleaned using soap and warm water. If this
isn’t sufficient, try ammonia and water or a nonabrasive liquid cleaner. When
cleaning the exterior, always rub with the “grain” of the stainless steel to
avoid marring the finish. Do not use an abrasive cleaner because it will
scratch the stainless steel and can damage the breaker strips and gaskets.
Stainless Steel Care and Cleaning
To prevent discoloration of rust on stainless steel several important steps
need to be taken. First, we need to understand the properties of stainless
steel. Stainless steel contains 70- 80% iron, which will rust. It also
contains 12-30% chromium, which forms an invisible passive film over the
steels surface, which acts as a shield against corrosion. As long as the
protective layer is intact, the metal is still stainless. If the film is
broken or contaminated, outside elements can begin to breakdown the steel and
begin to form discoloration of rust. Proper cleaning of stainless steel
requires soft cloths or plastic scouring pads.
NEVER USE STEEL PADS, WIRE BRUSHES OR SCRAPERS!
Cleaning solutions need to be alkaline based or non-chloride cleaners. Any
cleaner containing chlorides will damage the protective film of the stainless
steel. Chlorides are also commonly found in hard water, salts, and household
and industrial cleaners. If cleaners containing chlorides are used be sure to
rinse repeatedly and dry thoroughly. Routine cleaning of stainless steel can
be done with soap and water. Extreme stains or grease should be cleaned with a
non-abrasive cleaner and plastic scrub pad. Always rub with the grain of the
steel. There are stainless steel cleaners available which can restore and
preserve the finish of the steels protective layer. Early signs of stainless
steel breakdown are small pits and cracks. If this has begun, clean thoroughly
and start to apply stainless steel cleaners in attempt to restore the
passivity of the steel.
** Never use an acid based cleaning solution! Many food products have an
acidic content, which can deteriorate the finish. Be sure to clean the
stainless steel surfaces of ALL food products. Common items include, tomatoes,
peppers and other vegetables.
Cleaning the Condenser Coil
In order to maintain proper refrigeration performance, the condenser fins must
be cleaned of dust, dirt and grease regularly. It is recommended that this be
done at least every three months. If conditions are such that the condenser is
totally blocked in three months, the frequency of cleaning should be
increased. Clean the condenser with a vacuum cleaner or stiff brush. If
extremely dirty, a commercially available condenser cleaner may be required.
Failure to maintain a clean condenser coil can initially cause high
temperatures and excessive run times. Continuous operation with a dirty or
clogged condenser coil can result in compressor failure. Neglecting the
condenser coil cleaning procedures will void any warranties associated with
the compressor and cost to replace the compressor.
** Never use a high-pressure water wash for this cleaning procedure as
water can damage the electrical components located near or at the condenser
coil.
Doors/Hinges
Over time and with heavy use doors the hinges may become loose. If this
happens tighten the screws that mount the hinge brackets to the frame of the
unit. Loose or sagging doors can cause the hinges to pull out of the frame,
which may damage both the doors and the hinges. In some cases this may require
qualified service agents or maintenance personnel to perform repairs.
Note Do not place hot pans on/against the blue ABS liner. Do not throw
items into the storage area. Failure to follow these recommendations could
result in damage to the interior of the cabinet or to the blower coil.
Overloading the storage area, restricting the airflow, and continuous opening
and closing of the doors and drawers will hamper the units ability to maintain
operational temperature.
Refrigerated rail units
Product in the rail should be removed to the refrigerated base at the end of
the day. This allows you to turn the rail off at night to save energy and to
defrost the rail. It also helps maintain product quality.
The standard wrapped refrigerated rail units are controlled by a low-pressure
control that is set to maintain the proper rail temperature. An on/off switch
is also provided for the rail and is required to be shut off at night. With a
LiquiTec rail a thermostat is provided to maintain rail temperature as well as
the rail on/off switch. The Liquate rail is required to be shut off at night
as well to allow for defrosting. To ensure product quality in the rail it is
recommended that product be rotated every four hours.
Note If adding any item to the unit, be sure to keep in mind the location
of the refrigeration lines on wrapped rail units. A refrigeration leak in a
rail is extremely difficult and costly to repair. In some cases it cannot be
repaired at all.
Preventing blower coil corrosion
To help prevent corrosion of the blower coil, store all acidic items, such as
pickles and tomatoes, in sealable containers. Immediately wipe up all spills.
Units with pans should be operated with pans in place.
Operating the unit without all pans in place will lower efficiency and may
damage the unit.
Continuous opening and closing of the doors will hamper the unit’s ability to
maintain optimum refrigeration temperature. Top section is not intended for
overnight storage. Product should be removed from pans. Pans can remain in
unit while empty.
Wiring Diagram, F18WC Wiring Diagram,
F18WR Wiring Diagram, F18MC,
F18SC, F18DC & F18RC Wiring Diagram, F18MR,
F18SR, F18DR & F18RRRemote reef with mech cooled
rall
Wiring Diagram, F18FC Wiring Diagram,
F18FR Wiring Diagram,
F18PD
Replacement Parts
F18DC|
---|---
3516053| Coil, solenoid, 120V/50/60HZ (rail)
*000-248-0030 | Coil assembly, R404A
*000-BN5-0035 | Condensing unit, 1/2hp, R404a
*000-BN5-0037 | Condensing unit, 1/3hp, R404a
*000-BN5-0030 | Condensing unit, 1/4hp, R404a
2193927| Control, Danfoss, GDM, 115V
2193927| Control, pressure, low
3234392 | Hinge, pan cover, center
3234282 | Hinge, pan cover, left
3234266| Hinge, pan cover, right
9321374 | Hinge, pin (for pan cover)
0160179 | Hinge Kit
3234645 | Leg, 6″, s/s
3977984 | Shelf, 19″ door
3977998 | Shelf, 24″ door
3978014 | Shelf, 27″ door
3977983 | Shelf, 32″ door
2190154 | Switch, rocker
3516225 | Valve, expansion (rail)
3516102 | Valve, solenoid (rail)
3234290 | Shelf support, 1″ blue
9321040 | Shelf support screw (coil side)
9321132 | Shelf support screw (wall side)
F18DR|
---|---
3516053 | Coil, solenoid, 120V/50/60HZ (rail)
*000-248-0030| Coil assembly, R404A
000-248-0037| Coil assembly, R404A, Fan Lt
2194824| Control, Danfoss, GDM, 115V
3234392 | Hinge, pan cover, center
3234282 | Hinge, pan cover, left
3234266 | Hinge, pan cover, right
9321374 | Hinge, pin (for pan cover)
0160179 | Hinge Kit (left or right hinged)
3234645 | Leg, 6″, s/s
3977984 | Shelf, 19″ door
3977998 | Shelf, 24″ door
3978014 | Shelf, 27″ door
3977983 | Shelf, 32″ door
3234290 | Shelf support, 1″ blue
9321040| Shelf support screw (coil side)
---|---
9321132 | Shelf support screw (wall side)
2190154| Switch, rocker
2194201 | Thermostat, rail
3516225| Valve, expansion (rail)
3516102| Valve, solenoid (rail)
F18FC|
---|---
000-BN5-0053| Condensing unit, 1/3HP, w/rec, hg
000-BN5-0054| Condensing unit, 1/2HP, low temp, hg
000-BN5-0055| Condensing unit, 3/4HP, low temp, hg
000-249-0004| Coil, assembly, freezer, R404a
2194758-4 | Control, Danfoss, Freezer, 115V
160179| Hinge Kit
3234645| Leg, 6″, s/s
9321040 | Shelf support screw (coil side)
9321132 | Shelf support screw (wall side)
3234290| Shelf support, 1″ blue
3977984 | Shelf, 19″ door
3977998 | Shelf, 24″ door
3978014 | Shelf, 27″ door
3977983 | Shelf, 32″ door
2190154| Switch, rocker
F18FR|
---|---
*000-249-0006| Coil assembly, frz evap, remote
3516053| Coil, solenoid, 120V/50/60HZ
3516056 | Control, Temperature
0160179 | Hinge Kit
3234645 | Leg, 6″, s/s
9321040 | Shelf support screw (coil side)
9321132 | Shelf support screw (wall side)
3234290 | Shelf support, 1″ blue
3977984 | Shelf, 19″ door
3977998 | Shelf, 24″ door
3978014| Shelf, 27″ door
3977983 | Shelf, 32″ door
2194151 | Timer, Paragon, #8145-00
3516102| Valve, solenoid
Replacement Parts, continued
F18MC| | F18PD48|
---|---|---|---
030-209-0030| Angle, Coil, Top Baffle| 000-248-0037| Coil assembly, R404A,
Fan Lt
3516053| Coil, solenoid, 120V/50/60HZ (rail)| 000-BN5-0040| Condensing
Assembly, 1/3-1/5 Stacked
000-248-0030| Coil assembly, R404A| 2194824| Control, Danfoss, GDM, 115V
000-248-0037| Coil assembly, R404A, Fan Lt| 2194938| Control, Tstat, Danfoss, Etc1h-1
000-BN5-0030| Condensing unit, 1/4hp, R404a| 000-402-0056| Cover Assembly, hinged, 6 pan, l/t
2194824| Control, Danfoss, GDM, 115V|
000-187-006B| Door Assembly, ref, 27×26, lt
2193927| Control, pressure, low|
3234645| Leg, 6, s/s, removable Foot
3234392| Hinge, pan cover, center|
356-478-0038| Panel, louver, 14.0, sw
Cut, lh
3234282| Hinge, pan cover, left|
3978014| Shelf, wire, coated
3234266| Hinge, pan cover, right|
3234290| Support, shelf, plastic
9321374| Hinge, pin (for pan cover)|
2190154| Switch, rocker, 20a/125v
0420068| Hinge kit, lo profile (left or right)|
3516135| Thermometer, hanging, 4
2190154| Switch, rocker| |
3516225| Valve, expansion (rail)| |
3516102| Valve, solenoid (rail)| F18PD72|
---|---|---|---
3234645| Leg, 6″, s/s|
000-248-0030| Coil assembly, R404A
---|---|---|---
| | 000-BN5-003Y| Condensing Assembly, 1/2-1/5 Stacked
| | 2194824| Control, Danfoss, GDM, 115V
F18MR
030-209-0030| __
Angle, Coil, Top Baffle
| 2194938 000-402-0056| Control, Tstat, Danfoss, Etc1h-1
Cover Assembly, hinged, 6pan, l/t
---|---|---|---
3516053| Coil, solenoid, 120V/50/60HZ (rail)|
000-187-006B| Door Assembly, ref, 27×26, lt
000-248-0030| Coil assembly, R404A| 000-187-006A| Door Assembly, ref, 27×26, rt
000-248-0037| Coil assembly, R404A, Fan Lt| 3234645| Leg, 6, s/s, removable Foot
2194824| Control, Danfoss, GDM, 115V|
356-478-0039| Panel, louver, 18.0, sw
Cut, lh
3234392| Hinge, pan cover, center|
3978014| Shelf, wire, coated
3234282| Hinge, pan cover, left|
3234290| Support, shelf, plastic
3234266| Hinge, pan cover, right|
2190154| Switch, rocker, 20a/125v
9321374| Hinge, pin (for pan cover)|
3516135| Thermometer, hanging, 4
0420068| Hinge kit, lo profile (left or right)| |
3234645| Leg, 6″, s/s| |
9321041| Nut, acorn (for pan cover)| |
2190154| Switch, rocker| |
2194201| Thermostat, rail| |
3516225| Valve, expansion (rail)| |
3516102| Valve, solenoid (rail)| |
3516053| Coil, solenoid, 120V/50/60HZ (rail)
---|---
*000-248-0030| Coil assembly, R404A
*000-BN5-0035| Condensing unit, 1/2hp, R404a
*000-BN5-0037| Condensing unit, 1/3hp, R404a
*000-BN5-0030| Condensing unit, 1/4hp, R404a
2194824| Control, Danfoss, GDM, 115V
2193927| Control, pressure, low
3234392| Hinge, pan cover, center
3234282| Hinge, pan cover, left
3234266| Hinge, pan cover, right
9321374| Hinge, pin (for pan cover)
160179| Hinge Kit
3234645| Leg, 6″, s/s
3977984| Shelf, 19″ door
3977998| Shelf, 24″ door
3978014| Shelf, 27″ door
3977983| Shelf, 32″ door
3234290| Shelf support, 1″ blue
9321040| Shelf support screw (coil side)
9321132| Shelf support screw (wall side)
2190154| Switch, rocker
3516225| Valve, expansion (rail)
3516102| Valve, solenoid (rail)
F18RR| Coil, solenoid, 120V/50/60HZ (rail)
---|---
3516053| Coil assembly, R404A
*000-248-0030| Coil assembly, R404A, Fan Lt
000-248-0037| Control, Danfoss, GDM, 115V
2194824| Hinge, pan cover, center
3234392| Hinge, pan cover, left
3234282| Hinge, pan cover, right
3234266| Hinge, pin (for pan cover)
9321374| Hinge Kit
160179| Leg, 6″, s/s
3234645| Shelf, 19″ door
3977984| Shelf, 24″ door
3977998| Shelf, 27″ door
3978014| Shelf, 32″ door
3977983| Shelf support, 1″ blue
3234290| Shelf support screw (coil side)
9321132| Shelf support screw (wall side)
2190154| Switch, rocker
2194201| Thermostat, rail
3516225| Valve, expansion (rail)
3516102| Valve, solenoid (rail)
F18SC|
---|---
3516053| Angle, Coil, Top Baffle
030-209-0030 | Coil, solenoid, 120V/50/60HZ (rail)
000-248-0037| Coil assembly, R404A
*000-248-0030| Coil assembly, R404A, Fan Lt
000-BN5-0030| Condensing unit, 1/4hp, R404a
2194824| Control, Danfoss, GDM, 115V
2193927| Control, pressure, low
3234392| Hinge, pan cover, center
3234282| Hinge, pan cover, left
3234266| Hinge, pan cover, right
9321374| Hinge, pin (for pan cover)
420068| Hinge kit, lo profile (left or right)
3234645| Leg, 6″, s/s
2190154| Switch, rocker
3516225| Valve, expansion (rail)
3516102| Valve, solenoid (rail)
F18SR|
---|---
030-209-0030| Angle, Coil, Top Baffle
3516053 | Coil, solenoid, 120V/50/60HZ (rail)
[000-248-0030 ](http://www.partstown.com/delfield/del000-248-0030?pt-manual
=DEL-F18_spm.pdf)| Coil assembly, R404A
000-248-0037| Coil assembly, R404A, Fan Lt
2194824| Control, Danfoss, GDM, 115V
3234392 | Hinge, pan cover, center
3234282 | Hinge, pan cover, left
3234266| Hinge, pan cover, right
9321374 | Hinge, pin (for pan cover)
0420068 | Hinge kit, lo profile (left or right)
3234645 | Leg, 6″, s/s
2190154| Switch, rocker
2194201 | Thermostat, rail
3516225 | Valve, expansion (rail)
3516102 | Valve, solenoid (rail)
F18WC|
---|---
[000-248-0030 ](http://www.partstown.com/delfield/del000-248-0030?pt-manual
=DEL-F18_spm.pdf)| Coil assembly, R404A
000-248-0037| Coil assembly, R404A, Fan Lt
[000-BN5-0030](http://www.partstown.com/delfield/del000-bn5-0030?pt-manual
=DEL-F18_spm.pdf)| Condensing unit, 1/4hp, R404a
000-BN5-0031| Condensing unit, 1/5hp, R404a
2194810| Control, Danfoss, GDM, 115V
0160179 | Hinge Kit
3234645 | Leg, 6″, s/s
3977984 | Shelf, 19″ door
3977998| Shelf, 24″ door
397801| Shelf, 27″ door
3977983 | Shelf, 32″ door
2190154 | Switch, rocker
3234290| Shelf support, 1″ blue
9321040| Shelf support screw (coil side)
9321132| Shelf support screw (wall side)
F18WR|
---|---
[000-248-0030 ](http://www.partstown.com/delfield/del000-248-0030?pt-manual
=DEL-F18_spm.pdf)| Coil assembly, R404A
*000-248-0037| Coil assembly, R404A, Fan Lt
2194810| Control, Danfoss, GDM, 115V
0160179 | Hinge Kit (left or right hinged)
3234645 | Leg, 6″, s/s
3977984 | Shelf, 19″ door
3977998 | Shelf, 24″ door
3978014| Shelf, 27″ door
3977983 | Shelf, 32″ door
3234290 | Shelf support, 1″ blue
9321040| Shelf support screw (coil side)
9321132 | Shelf support screw (wall side)
Replacement Part Assemblies
Key | Part Number | Description |
---|---|---|
– | 000-249-0004 | Coil Assembly, Evap, Freezer |
1 | 030-262-0001 | Side, evaporator |
2 | [2160023](http://www.partstown.com/delfield/del2160023?pt-manual=DEL- | |
F18_spm.pdf) | Fan, axiel | |
3 | [2160024](http://www.partstown.com/delfield/del2160024?pt-manual=DEL- | |
F18_spm.pdf) | Guard, fan, 4.7″, SC120-W2 | |
4 | 030-260-0001 | Top, frz, evaporator |
5 | 030-259-0000 | Front, enclosure |
6 | [3516271](http://www.partstown.com/delfield/del3516271?pt-manual=DEL- | |
F18_spm.pdf) | Valve, expansion, R404a | |
7 | 265-261-0001 | Pan, freezer |
evaporator
8| 3516073| Coil, Evaporator
9| 030-263-0001| Back, evaporator
–| 2184318| Harness, coil, frz, male
–| 2194808| Probe, Defrost, Danfoss, Control
–| 2194809| Probe, Temp, Sensor, Danfoss
Key | Part Number | Description |
---|---|---|
– | 000-249-0006 | Coil Assembly, Freezer Evap, Remote |
1 | 030-262-0001 | Side, evaporator |
2 | [2160023](http://www.partstown.com/delfield/del2160023?pt-manual=DEL- | |
F18_spm.pdf) | Fan, axiel | |
3 | [2160024](http://www.partstown.com/delfield/del2160024?pt-manual=DEL- | |
F18_spm.pdf) | Guard, fan, 4.7″, SC120-W2 | |
4 | 030-260-0001 | Top, frz, evaporator |
5 | 030-259-0000 | Front, enclosure |
6 | [3516271](http://www.partstown.com/delfield/del3516271?pt-manual=DEL- | |
F18_spm.pdf) | Valve, expansion, R404a | |
7 | [3516073](http://www.partstown.com/delfield/del3516073?pt-manual=DEL- | |
F18_spm.pdf) | Coil, Evaporator | |
8 | [2194034](http://www.partstown.com/delfield/del2194034?pt-manual=DEL- | |
F18_spm.pdf) | Heater, Defrost | |
9 | 265-261-0001 | Pan, freezer |
evaporator
10| 030-263-0001| Back, evaporator
–| 2194046| Control, Limit, Fan Delay/Defrost
–| 2194631| Fuse, Defrost Heater, 7 Amp
–| 2184323| Harness, coil, frz, male, remote
Key | Part Number | Description |
---|---|---|
– | [ 000-248-0030](http://www.partstown.com/delfield/del000-248-0030 | |
?pt-manual=DEL-F18_spm.pdf) | Coil Assembly, R404A, Ref | |
1 | [2160024](http://www.partstown.com/delfield/del2160024?pt-manual=DEL- | |
F18_spm.pdf) | Guard, fan, 4.7″ | |
2 | [2160023](http://www.partstown.com/delfield/del2160023?pt-manual=DEL- | |
F18_spm.pdf) | Fan, axiel, 120V | |
3 | [3516095](http://www.partstown.com/delfield/del3516095?pt-manual=DEL- | |
F18_spm.pdf) | Coil, evaporator | |
4 | 030-232-0003 | Back, evaporator, enclosure |
5 | [3516273](http://www.partstown.com/delfield/del3516273?pt-manual=DEL- | |
F18_spm.pdf) | Expansion valve, 1/4, R-404a | |
6 | 030-233-0001 | Side, coil, angled |
7 | 075-231-0033 | Drip pan, evaporator |
8 | 030-234-0003 | Front, coil |
– | [2184317](http://www.partstown.com/delfield/del2184317?pt-manual=DEL- | |
F18_spm.pdf) | Harness, coil | |
– | [2194808](http://www.partstown.com/delfield/del2194808?pt-manual=DEL- | |
F18_spm.pdf) | Probe, Defrost, Danfoss, Control | |
– | [2194809](http://www.partstown.com/delfield/del2194809?pt-manual=DEL- | |
F18_spm.pdf) | Probe, Temp, Sensor, Danfoss |
Key | Part Number | Description |
---|---|---|
– | 000-248-0037 | Coil Assembly, R404A, Ref, Fan Lt |
1 | [2160024](http://www.partstown.com/delfield/del2160024?pt-manual=DEL- | |
F18_spm.pdf) | Guard, fan, 4.7″ | |
2 | [2160023](http://www.partstown.com/delfield/del2160023?pt-manual=DEL- | |
F18_spm.pdf) | Fan, axiel, 120V | |
3 | [3516095](http://www.partstown.com/delfield/del3516095?pt-manual=DEL- | |
F18_spm.pdf) | Coil, evaporator | |
4 | 030-232-0003 | Back, evaporator, enclosure |
5 | [000-BNH-0030](http://www.partstown.com/delfield/del000-bnh-0030?pt-manual | |
=DEL-F18_spm.pdf) | Drip pan, evaporator | |
6 | 030-233-0038 | Side, coil, angled, Rt, Blank |
7 | [3516273](http://www.partstown.com/delfield/del3516273?pt-manual=DEL- | |
F18_spm.pdf) | Expansion valve, 1/4, R-404a | |
8 | 030-234-0003 | Front, coil |
9 | 030-233-0039 | Side, Coil, Angled, Lt, 2Fan |
– | [2184317](http://www.partstown.com/delfield/del2184317?pt-manual=DEL- | |
F18_spm.pdf) | Harness, coil | |
– | [2194808](http://www.partstown.com/delfield/del2194808?pt-manual=DEL- | |
F18_spm.pdf) | Probe, Defrost, Danfoss, Control | |
– | [2194809](http://www.partstown.com/delfield/del2194809?pt-manual=DEL- | |
F18_spm.pdf) | Probe, Temp, Sensor, Danfoss |
Key | Part Number | Description |
---|---|---|
– | [ 000-BN5-0030](http://www.partstown.com/delfield/del000-bn5-0030 | |
?pt-manual=DEL-F18_spm.pdf) | Assembly, 1/4 HP Condensing Unit | |
1 | [2160028](http://www.partstown.com/delfield/del2160028?pt-manual=DEL- | |
F18_spm.pdf) | Fan, Axial, 5.5″, 120V | |
2 | [2160030](http://www.partstown.com/delfield/del2160030?pt-manual=DEL- | |
F18_spm.pdf) | Guard, Fan, 6.0″ | |
3 | 026-C58-0037 | Shroud, Condenser Coil |
4 | [3526999](http://www.partstown.com/delfield/del3526999?pt-manual=DEL- | |
F18_spm.pdf) | Compressor, Danfoss, NF5.5CLX | |
5 | [2194787](http://www.partstown.com/delfield/del2194787?pt-manual=DEL- | |
F18_spm.pdf) | Start Capacitor |
3516444| Comp, Relay, Overload, NF5.5CLX
6| 3516322| Filter Dryer
7| 075-231-0030| Condensate Pan
8| 3516454| Condenser Coil
Key | Part Number | Description |
---|---|---|
– | 000-BN5-0031 | Assembly, 1/5 Condensing Unit |
1 | [2160028](http://www.partstown.com/delfield/del2160028?pt-manual=DEL- | |
F18_spm.pdf) | Fan, Axial, 5.5.”, 120V | |
2 | [2160030](http://www.partstown.com/delfield/del2160030?pt-manual=DEL- | |
F18_spm.pdf) | Guard, Fan, 6.0″ | |
3 | 026-C58-0037 | Shroud, Condenser Coil |
4 | [3526997](http://www.partstown.com/delfield/del3526997?pt-manual=DEL- | |
F18_spm.pdf) | Compressor, Danfoss, TF4CLS | |
5 | [2194787](http://www.partstown.com/delfield/del2194787?pt-manual=DEL- | |
F18_spm.pdf) | Start Capacitor |
3516446| Comp, Relay, Danfoss
6| 3516322| Filter Dryer
7| 075-231-0030| Condensate Pan
8| 3516454| Condenser Coil
Key | Part Number | Description |
---|---|---|
– | 000-BN5-0054 | Assembly, 1/2HP Cond, Low, Hot gas |
1 | [3516554](http://www.partstown.com/delfield/del3516554?pt-manual=DEL- | |
F18_spm.pdf) | Blade, Fan, 9.00” | |
2 | [2160019](http://www.partstown.com/delfield/del2160019?pt-manual=DEL- | |
F18_spm.pdf) | Guard, Fan, Wire | |
3 | [2162716](http://www.partstown.com/delfield/del2162716?pt-manual=DEL- | |
F18_spm.pdf) | Motor, Fan, 16W, 115V, CW | |
4 | [3516324](http://www.partstown.com/delfield/del3516324?pt-manual=DEL- | |
F18_spm.pdf) | Cutout, High Pressure | |
5 | [3527001](http://www.partstown.com/delfield/del3527001?pt-manual=DEL- | |
F18_spm.pdf) | Compressor, SC12CLX.2,115/60HZ | |
6 | [3516322](http://www.partstown.com/delfield/del3516322?pt-manual=DEL- | |
F18_spm.pdf) | Drier, Filter, (2)Inlet | |
7 | [2194789](http://www.partstown.com/delfield/del2194789?pt-manual=DEL- | |
F18_spm.pdf) | Capacitor, Start, 240MFD | |
8 | [3516441](http://www.partstown.com/delfield/del3516441?pt-manual=DEL- | |
F18_spm.pdf) | Relay, Comp, SC12CLX.2 | |
9 | [3516455](http://www.partstown.com/delfield/del3516455?pt-manual=DEL- | |
F18_spm.pdf) | Coil, Condenser, 1/2 HP | |
– | 024-034-0031 | Pan, Comp, 18.00 |
Key | Part Number | Description |
---|---|---|
– | 000-BN5-0055 | Assembly, 3/4 HP Cond, Low, Hot gas |
1 | [2160019](http://www.partstown.com/delfield/del2160019?pt-manual=DEL- | |
F18_spm.pdf) | Guard, fan condenser |
2162716| Motor, condenser fan 16W, 155V
3516433| Blade, fan 10” CW
2| 3527002| Compressor, SC18CLS.2, 115V60hz
3516442| Capacitor, start, run assembly
3| 3516322| Filter drier
4| 3516456| Coil, condenser, 3/4hp
Key | Part Number | Description |
---|---|---|
– | [ 000-BN5-0035](http://www.partstown.com/delfield/del000-bn5-0035 | |
?pt-manual=DEL-F18_spm.pdf) | Assembly, 1/2HP Condenser, Med | |
1 | [3516554](http://www.partstown.com/delfield/del3516554?pt-manual=DEL- | |
F18_spm.pdf) | Condenser fan blade | |
2 | [2160019](http://www.partstown.com/delfield/del2160019?pt-manual=DEL- | |
F18_spm.pdf) | Condenser fan guard | |
3 | [2162716](http://www.partstown.com/delfield/del2162716?pt-manual=DEL- | |
F18_spm.pdf) | Condenser fan motor, 115V | |
4 | [3516462](http://www.partstown.com/delfield/del3516462?pt-manual=DEL- | |
F18_spm.pdf) | Capacitor, start-run assy | |
5 | [3527026](http://www.partstown.com/delfield/del3527026?pt-manual=DEL- | |
F18_spm.pdf) | Compressor, Danfoss, SC12MLX | |
6 | [3516331](http://www.partstown.com/delfield/del3516331?pt-manual=DEL- | |
F18_spm.pdf) | Hi pressure switch | |
7 | [3516322](http://www.partstown.com/delfield/del3516322?pt-manual=DEL- | |
F18_spm.pdf) | Filter Drier | |
8 | 075-231-0031 | Pan, Condensate |
9 | [3516455](http://www.partstown.com/delfield/del3516455?pt-manual=DEL- | |
F18_spm.pdf) | Condenser coil |
Key | Part Number | Description |
---|---|---|
– | [ 000-BN5-0037](http://www.partstown.com/delfield/del000-bn5-0037 | |
?pt-manual=DEL-F18_spm.pdf) | Assembly, 1/3 Condensing Unit | |
1 | [2160028](http://www.partstown.com/delfield/del2160028?pt-manual=DEL- | |
F18_spm.pdf) | Fan, Axial, 5.5″, 120V | |
2 | [2160030](http://www.partstown.com/delfield/del2160030?pt-manual=DEL- | |
F18_spm.pdf) | Guard, Fan, 6.0″ | |
3 | 026-C58-0037 | Shroud, Condenser Coil |
4 | [3527000](http://www.partstown.com/delfield/del3527000?pt-manual=DEL- | |
F18_spm.pdf) | Compress, Danfoss, NF7CLS | |
5 | [2194788](http://www.partstown.com/delfield/del2194788?pt-manual=DEL- | |
F18_spm.pdf) | Start Capacitor |
3516438| Relay, overload, compressor
6| 3516322| Filter Drier
7| 3516458| Receiver tank
8| 075-231-0030| Pan, Condensate
9| 3516454| Condenser Coil
Key | Part Number | Description |
---|---|---|
– | 000-BN5-0053 | Assembly, 1/3HP Cond, w/rec, hg |
1 | [2160028](http://www.partstown.com/delfield/del2160028?pt-manual=DEL- | |
F18_spm.pdf) | Fan, Axial, 5.5″, 120V | |
2 | [2160030](http://www.partstown.com/delfield/del2160030?pt-manual=DEL- | |
F18_spm.pdf) | Guard, Fan, 6.0″ | |
3 | [3516053](http://www.partstown.com/delfield/del3516053?pt-manual=DEL- | |
F18_spm.pdf) | Coil, Solenoid, 120V | |
4 | [3516102](http://www.partstown.com/delfield/del3516102?pt-manual=DEL- | |
F18_spm.pdf) | Valve, Solenoid, 1/4ODF | |
5 | [3527000](http://www.partstown.com/delfield/del3527000?pt-manual=DEL- | |
F18_spm.pdf) | Compressor, NF7.0,115/60HZ, Danfoss | |
6 | [3516438](http://www.partstown.com/delfield/del3516438?pt-manual=DEL- | |
F18_spm.pdf) | Relay, Comp, ovld |
2194788| Capacitor, Start, 320MFD
7| 000-998-0030| High Pressure Assembly, 8Amp
8| 3516397| Accumulator
9| 3516322| Filter Drier, (2)Inlet
10| 3516458| Receiver
11| 3516454| Coil, Condenser
000-BN5-003Y | Assembly, 1/2-1/5 Stacked, |
---|
3516457| Blade, Fan, 7.25 Dia.,
3516433| Blade, fan, 25deg, 10″, cw
2194789| Capacitor, start, 240mfd
2194787| Capacitor, start, 280mfd
3516454| Coil, Condenser, 1/5, 1/4,
3516455| Coil, Condenser, 1/2 Hp
3526997| Compressor, 1/5hp, 115/60, r404a
3527001| Compressor, sc12clx.2, 115/60hz,
3516322| Drier, filter, (2)inlet
2160020| Guard, Fan, 7.25
2160019| Guard, fan, wire
2162717| Motor, fan, 9w, 115v, cw
2162513| Motor, fan, 35w, blast
3516193| Regulator, pressure, 1/2
3516446| Relay, Compressor, Danfoss
3516441| Relay, compressor, sc12clx.2
3516225| Valve, expansion, frz, 1/4ton
000-BN5-0040 | Assy, 1/3-1/5 Stacked, |
---|
3516457| Blade, Fan, 7.25 Dia.
2194787| Capacitor, start, 280mfd
2194788| Capacitor, start, 320mfd
3516454| Coil, Cond., 1/5, 1/4
3526997| Comp, 1/5hp, 115/60, r404a
3527000| Comp, nf7cls, 115v/60hz
3516322| Drier, filter, (2)inlet
2160020| Guard, Fan, 7.25
2162717| Motor, fan, 9w,115v,cw
3516193| Regulator, pressure, 1/2
3516446| Relay, Comp, Danfoss
3516438| Relay, comp, ovld, nf7clx
3516225| Valve, exp, frz, 1/4ton
359-478-003E | Panel, louver, 15.0, ptb |
---|
359-478-003D| Panel, louver, 18.0, ptb
356-478-0038| Panel, louver, 14.0,
swCut,lh
356-478-0039| Panel, louver, 18.0,
swCut,lh
000-187-0081| Door Assembly, ref, 27×26, rt, 430
---|---
000-187-0082| Door Assembly, ref, 27×26, lt, 430
000-187-006B| Door Assembly, ref, 27×26, lt
000-187-006A| Door Assembly, ref, 27×26, rt
1701185| Gasket, door, 27, mark7
0420067| Hinge Kit
000-402-0054 | Cover Assembly, hinged, 6 Pan, ptl |
---|---|
000-402-0056 | Cover Assembly, hinged, 6pan, l/t |
9321374| Pin, hinge, salad Pan
3234266| Hinge, pan Cover, end, rh,
3234282| Hinge, pan Cover, end, lh,
3234392| Hinge, pan Cover,
Standard Labor Guidelines To Repair Or Replace Parts On Delfield Equipment
Advice and recommendations given by Delfield Service Technicians do not
constitute or guarantee any special coverage.
- A maximum of 1-hour is allowed to diagnose a defective component.
- maximum of 1-hour is allowed for retrieval of parts not in stock.
- A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
- Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work Authorization from Delfield. You must submit the number with the service claim.
Labor Of 1-Hour Is Allowed To Replace:
- Thermostat
- Infinite Switch
- Door Jamb Switch
- Solenoid Coil
- Hi-limit/Thermal Protector Switch
- Fan Delay/Defrost Termination Switch
- Compressor Start Components and Overload Protector
- Defrost Timer
- Thermometer
- Gear Box
- Contactor/Relay
- Transformer
- Evaporator/Condenser Fan Motor and Blade
- Circulating Fan Motor and Blade
- Microprocessor Control
- Water Level Sensor/Probe
- Door Hinges, Locks, and Gaskets
- Condensate Element
- Springs/Lowerator
Labor Of 2 Hours To Replace:
- Drawer Tracks/Cartridges
- Pressure Control
- Solenoid Valve
- Defrost Element
- Heating Element
- Locate/Repair Leak
Labor Of 3 Hours To Replace:
- EPR or CPR Valve
- Expansion Valve
- Condenser or Evaporator Coil
Labor Of 4 Hours To Replace:
- Compressor
This includes recovery of refrigerant and leak check.
$55.00 maximum reimbursement for refrigerant recovery (includes recovery
machine, pump, torch, oil, flux, minor fittings, solder, brazing rod,
nitrogen, or similar fees.)
Refrigerants:
- R22 A maximum of $4.00/lb. or 25¢/oz. will be reimbursed.
- R134A A maximum of $5.00/lb. or 31¢/oz. will be reimbursed.
- R404A A maximum of $16.00/lb. or $1.00/oz. will be reimbursed.
![Delfield F18 Series Refrigerated Work Tables Salad Tables and Freezer Bases
- Mt. Pleasant](https://manuals.plus/wp-content/uploads/2023/10/Delfield-F18 -Series-Refrigerated-Work-Tables-Salad-Tables-and-Freezer-Bases- Mt.-Pleasant-1.png) Mt. Pleasant, MI Covington, TN
Thank you for choosing Delfield!
Help is a phone call away. Help our team of professional, courteous customer
service reps by having your model number and serial number available at the
time of your call 800-733-8829.
Model:……………………… S/N: …………….
Installation Date:………………………. For a list of Delfield’s authorized parts depots,
visit our website at www.delfield.com
|Register your Delfield warranty online. Go to
www.delfield.com under the service tab to complete.
980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A.
989-773-7981 or
800-733-8829
Fax 989-773-3210
www.delfield.com
Delfield reserves the right to make changes in design or specifications
without prior notice.
©2013 The Delfield Company. All rights reserved. Printed in the U.S.A.
DM18 07/13
9291454
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>