DELFIELD EHEI36C E-Chef Hot Food Table Instruction Manual
- June 4, 2024
- DELFIELD
Table of Contents
Fresh Solutions, Fit For You
EHEI36C E-Chef Hot Food Table
Instruction Manual
Original Instructions Installation, Operation, and Maintenance Manual
This manual is updated as new information and models are released. Visit our website for the latest manual.
Original Document
Part Number 9291472 12/21
Caution
Read this instruction before operating this equipment.
General Information
Warning
Read this manual thoroughly before operating, installing, or performing
maintenance on the equipment. Failure Following instructions in this manual
can cause property damage, injury, or death.
DANGER
Do not install or operate equipment that has been misused, abused, neglected,
damaged, or altered/modified from that of original manufactured
specifications.
DANGER
Never stand on the unit! They are not designed to hold the weight of an adult
and may collapse or tip if misused.
warning
Authorized Service Representatives are obligated to follow industry-standard
safety procedures, including, but not limited to, local/national regulations
for disconnection / lock out / tag out procedures for all utilities including
electric, gas, water, and steam.
Warning
Do not store or use gasoline or other flammable vapors or liquids within or
around the vicinity of this or any other appliance. Never use flammable oil-
soaked cloths or combustible cleaning solutions, for cleaning.
Warning
This product contains chemicals known to the State of California to cause
cancer and/or birth defects or other reproductive harm. Operation,
installation, and servicing of this product could expose you to airborne
particles of glasswool or ceramic fibers, crystalline silica, and/ or carbon
monoxide. Inhalation of airborne particles of glasswool or ceramic fibers is
known to the State of California to cause cancer. Inhalation of carbon
monoxide is known to the State of California to cause birth defects or other
reproductive harm.
Warning
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge unless they have been given supervision concerning the use of the
appliance by a person responsible for their safety. Do not allow children to
play with this appliance.
Notice
Proper installation, care, and maintenance are essential for maximum
performance and trouble-free operation of your equipment. Visit our website
www.mtwkitchencare.com for manual updates,
translations, or contact information for service agents in your area.
Notice
These appliances are intended to be used for commercial applications, for
example in kitchens or restaurants, canteens, hospitals, and in commercial
enterprises such as bakeries, butcheries, etc., but not for continuous mass
production of food.
Notice
Climatic class 4 is defined as ambient conditions of 30°C and 55% relative
humidity, according to ISO 23953-2.
Notice
This product utilizes Ecomate blowing agent methyl formate
Serial Number Location
The serial number on all E-Chef™ Series models is printed on the tag located
on the interior side panel.
Always have the serial number of your unit available when calling for parts or
services.
Warranty Information
Visit www.delfield.com/warranty to:
- Register your product for a warranty.
- Verify warranty information.
- View and download a copy of your warranty.
Regulatory Certifications
USA DOMESTIC MODELS ARE CERTIFIED BY:
- National Sanitation Foundation (NSF)
- Underwriters Laboratories (UL)
- Underwriters Laboratories of Canada (cUL)
EXPORT (-E) MODELS ARE CERTIFIED BY:
- National Sanitation Foundation (NSF)
- European Conformity Technical Inspection Association
Model Numbers
This manual covers the following E-Chef™ Hot Food Tables:
Standard Model | Models with Export Option |
---|---|
With Casters | With Legs |
EHEI36C | EHEI36L |
EHEI48C | EHEI48L |
EHEI60C | EHEI60L |
EHEI74C | EHEI74L |
Installation
DANGER
Installation must comply with all applicable fire and health codes in your
jurisdiction.
DANGER
Risk of fire/shock. All minimum clearances must be maintained. Do not obstruct
vents or openings.
DANGER
Use appropriate safety equipment during installation and servicing.
DANGER
All utility connections and fixtures must be maintained in accordance with
local and national codes.
Warning
Remove all removable panels before lifting and installing.
Warning
Use caution when handling metal surface edges of all equipment.
Location
Warning
These appliances are to be connected with flexible connections for
equipotential bonding and connection to services such as electricity supply,
water supply, gas supply, and steam supply such that the appliance can be
moved in the direction required for cleaning for a distance not less than the
dimension of the application in the direction of movement plus 500mm without
the flexible connections becoming taught or being subject to strain.
Warning
To avoid instability the installation area must be capable of supporting the
combined weight of the equipment and product. Additionally, the equipment must
be level side to side and front to back.
Warning
This equipment is intended for indoor use only. Do not install or operate this
equipment in outdoor areas. The location selected for the equipment must meet
the following criteria. If any of these criteria are not met, select another
location.
- Units are intended for indoor use only.
- The location MUST be level, stable, and capable of supporting the weight of the equipment.
- The location MUST be free from and clear of combustible materials.
- Do not install near objects or surfaces affected by heat or moisture.
- Equipment MUST be level both fronts to back and side to side.
- Position the equipment so it will not tip or slide.
- Recommended air temperature is 41° – 86°F (5° – 30°C).
- Proper air supply for ventilation is REQUIRED AND CRITICAL for safe and efficient operation. Refer to the Clearance Requirements chart on page 8.
- Do not install the equipment directly over a drain. Steam rising up out of the drain will adversely affect the operation, and air circulation, and damage electrical/electronic
components.
Weight of Equipment
Model | Weight |
---|---|
EHEI36 | 250lbs (113kg) |
EHEI48 | 280lbs (127kg) |
EHEI60 | 310lbs (141kg) |
EHEI74 | 350lbs (159kg) |
Notice
This symbol indicates the location of the equipotential bonding conductor
connection.
Notice
This symbol indicates a hot surface that can cause injury to persons.
Clearance Requirements
DANGER
Minimum clearance requirements are the same for noncombustible locations as
for combustible locations. The flooring under the appliance must be made of
noncombustible material.
- The factory-installed legs must be used and not removed.
Dimensions
Model | Length | Depth | Height |
---|---|---|---|
EHEI36 | 36.00” (91cm) | 31.50” (80cm) | 36.00” (91cm) |
EHEI48 | 48.00” (122cm) | 31.50” (80cm) | 36.00” (91cm) |
EHEI60 | 60.00” (152cm) | 31.50” (80cm) | 36.00” (91cm) |
EHEI74 | 74.00” (188cm) | 31.50” (80cm) | 36.00” (91cm) |
Capacity
Model | Number of 11.87” x 19.87” (30.2cm x 50.5cm) openings |
---|---|
EHEI36 | 2 |
EHEI48 | 3 |
EHEI60 | 4 |
EHEI74 | 5 |
Electrical Service
DANGER
Check all wiring connections, including factory terminals, before operation.
Connections can become loose during shipment and installation.
Warning
This appliance must be grounded and all field wiring must conform to all
applicable local and national codes. Refer to rating plate for proper voltage.
It is the responsibility of
the end user to provide the disconnect means to satisfy the authority having
jurisdiction.
All electrical work, including wire routing and grounding, must conform to
local, state, and national electrical codes. The following precautions must be
observed:
-
The equipment must be grounded.
-
A separate fuse/circuit breaker must be provided for each unit.
-
A qualified electrician must determine the proper wire size dependent upon location, materials used, and length of run (minimum circuit ampacity can be used to help select
the wire size). -
The maximum allowable voltage variation is ±10% of the rated voltage at equipment start-up (when the electrical load is highest).
-
Check all green ground screws, cables, and wire connections to verify they are tight before start-up.
Model | Voltage, Cycle, Phase | Amps | Plug | Watts |
---|---|---|---|---|
EHEI36C | 120, 60, 1 | 20 | Hard wired | – |
EHEI36C-E | 240, 50, 1 | – | CEE 7/7 | 2900 |
EHEI36L | 120, 60, 1 | 20 | 5-30P | – |
EHEI36L-E | 240, 50, 1 | – | CEE 7/7 | 2900 |
EHEI48C | 208/230, 60, 1 | 15.0/16.0 | Hard wired | – |
EHEI48C-E | 240, 50, 1 | – | CEE 7/7 | 4350 |
EHEI48L | 208/230, 60, 1 | 15.0/16.0 | 6-20P | – |
EHEI48L-E | 240, 50, 1 | – | CEE 7/7 | 4350 |
EHEI60C | 208/230, 60, 1 | 20.0/22.0 | Hard wired | – |
EHEI60C-E | 240, 50, 1 | – | CEE 7/7 | 5800 |
EHEI60L | 208/230, 60, 1 | 20.0/22.0 | 6-30P | – |
EHEI60L-E | 240, 50, 1 | – | CEE 7/7 | 5800 |
EHEI74C | 208/230, 60, 1 | 24.0/27.0 | Hard wired | – |
EHEI74C-E | 240, 50, 1 | – | CEE 7/7 | 7250 |
EHEI74L | 208/230, 60, 1 | 24.0/27.0 | 6-50P | – |
EHEI74L-E | 240, 50, 1 | – | CEE 7/7 | 7250 |
Leg Leveling
All four legs are adjustable. Adjust each leg until the unit is stable and
level, both fronts to back and left to right. A level unit is necessary to
maintain an equal water depth
throughout the wells.
Plumbing
Warning
Moisture collecting from improper drainage can create a slippery surface on
the floor and a hazard to employees. It is the owner’s responsibility to
provide a container or outlet for drainage.
A waste connection is provided 26.5” (67cm) above the floor, and 5.25” (13cm)
from the right end. You must supply the required 1/2” (1.3cm) connection at
the gate valve.
Notice
These appliances will operate within the marked rated voltage range without
adjustment.
Operation
DANGER
The on-site supervisor is responsible for ensuring that operators are made
aware of the inherent dangers of operating this equipment.
DANGER
Steam can cause serious burns. Always wear some type of protective covering on
your hands and arms when removing lids or pans from the unit. Lift the lid or
pan in a way that will direct escaping steam away from your face and body.
DANGER
Do not operate any appliance with a damaged cord or plug. All repairs must be
performed by a qualified service company.
DANGER
Keep power cord AWAY from HEATED surfaces. DO NOT immerse the power cord in
water. DO NOT let the power cord hang over the edge of the table or counter.
Warning
When operated dry, the good bottoms become very hot. Do not allow unprotected
skin to contact any well surface.
Warning
The operator of this equipment is solely responsible for ensuring safe holding
temperature levels for all food items. Failure to do so could result in unsafe
food products for customers.
Warning
Do not use electrical appliances inside the food storage compartments of the
appliance, unless they are of the type recommended by the manufacturer.
Warning
All covers and access panels must be in place and properly secured, before
operating this equipment.
Warning
Opening the drain cock will lead to the outflow of the hot contents of the
bains-Marie.
Caution
Never use anything other than plain water in the wells or tanks. Failure to
observe this warning may result in personal injury or damage to the unit.
Caution
Using ice in hot food well can cause condensation and damage to the well over
time.
Before the unit is used the first time, turn the temperature knob to HI and
heat the well for up to 30 minutes. Any residue or dust that adhered to the
heater element(s) will be
burned off during this initial preheat period.
NOTE: Never place food directly into the well. Always use pans.
Although these models may be operated either with or without water in the
wells, the wet operation is recommended. When using thick sauces always
operate the hot food well filled with water. This will provide a more uniform
temperature for the sauce.
Always place covers on pans when not serving to prevent food from drying out
and to reduce your operating cost. For most efficient operation when empty or
pre-heating,
keep covered insets in each well.
Do not put food down the drain.
WET OPERATION
Use only 4” (10cm) deep pans during wet operation.
- Fill food well with 2” (50mm) of water. For quicker preheating, use hot water to fill the well.
- Turn the control to HI and pre-heat the warmer for 30 minutes. For the fastest pre-heating place covers or empty pans in the well.
- After pre-heating, set the control to your desired serving temperature.
DRY OPERATION
Use only 6” (15.2cm) deep pans during dry operation. When operated dry, the
bottom of the food well will discolor. A mild abrasive cleaner is recommended
to clean this discoloration.
- Pre-heat the well on HI for approximately 15 minutes. For the fastest pre-heating place covers or empty pans in the well.
- After preheating, set the control to your desired serving temperature.
TEMPERATURE
Water in wells | 160°F to 180°F (71°C to 82°C) |
---|---|
Product in pans | 140°F to 160°F (60°C to 71°C) |
THIS PAGE WAS INTENTIONALLY LEFT BLANK
Maintenance
DANGER
It is the responsibility of the equipment owner to perform a Personal
Protective Equipment Hazard Assessment to ensure adequate protection during
maintenance procedures.
DANGER
Failure to disconnect the power at the main power supply disconnect could
result in serious injury or death. The power switch DOES NOT disconnect all
incoming power.
DANGER
Disconnect electric power at the main power disconnect for all equipment being
serviced. Observe the correct polarity of incoming line voltage. Incorrect
polarity can lead to
erratic operation.
Warning
When cleaning the interior and exterior of the unit, avoid the front power
switch and the rear power cord. Keep water and/or cleaning solutions away from
these parts.
Warning
Never use a high-pressure water jet for cleaning or hosing down or flooding
the interior or exterior of units with water. Do not use power cleaning
equipment, steel wool, scrapers, or wire brushes on stainless steel or painted
surfaces.
Warning
When using cleaning fluids or chemicals, rubber gloves and eye protection
(and/or face shield) must be worn.
Caution
Never use an acid-based cleaning solution on exterior panels! Many food
products have an acidic content, which can deteriorate the finish. Be sure to
clean the stainless steel surfaces of ALL food products.
Caution
Maintenance and servicing work other than cleaning as described in this manual
must be done by authorized service personnel.
General
You are responsible for maintaining the equipment in accordance with the
instructions in this manual. Maintenance procedures are not covered by the
warranty.
Stainless Steel Cleaning
Clean the unit and around it as often as necessary to maintain cleanliness and
efficient operation. Wipe surfaces with a damp cloth rinsed in water to remove
dust and dirt from the unit. Always rub with the “grain” of the stainless
steel to avoid marring the finish. If a greasy residue persists, use a damp
cloth rinsed in a mild dish soap and water solution. Wipe dry with a clean,
soft cloth.
Never use steel wool or abrasive pads for cleaning. Never use chlorinated,
citrus-based, or abrasive cleaners.
Stainless steel exterior panels have a clear coating that is stain resistant
and easy to clean. Products containing abrasives will damage the coating and
scratch the panels. Daily cleaning may be followed by an application of
stainless steel cleaner which will eliminate water spotting and fingerprints.
Early signs of stainless steel breakdown are small pits and cracks. If this
has begun, clean thoroughly and start to apply stainless steel cleaners in an
attempt to restore the steel.
Food Wells
The interior of the food wells should be cleaned daily with a non-abrasive
cleaner and a non-abrasive pad. If necessary, a mild abrasive may be used on
the interior of the pans only. Hard water stains and lime scaling may require
a special cleaning product.
- Follow product instructions carefully if a sanitizer is used.
- Do not to leave cleaners in a food well overnight or for an extended period of time.
- Never use steel wool.
- Never use a high-pressure water wash for cleaning as water can damage the electrical components.
Drain
Each unit has a drain. Each drain can become loose or disconnected during
normal use. Be sure all drain lines are free of obstructions.
Maintenance | Daily | Weekly | After Prolonged Shutdown | At Start-Up |
---|---|---|---|---|
Interior & Exterior | X | X | X | |
Food Wells | X | X | X | |
Drain | X | X | X |
GFCI Troubleshoot
Cabinet trips GFCI (ground fault circuit interrupter):
A GFCI receptacle protects against “ground faults” whenever an electrical
product is plugged into the GFCI outlet. GFCI outlets or GFCI breakers
constantly monitor the current flowing from a hot to a neutral. If the current
leaving the receptacle is greater than what is returning, then this imbalance
will cause the GFCI to trip in order to protect the user from electrical
shock.
Heaters are prone to absorbing moisture into the heater themselves during long
periods of not being used such as shipping or summer breaks. There are a
couple of ways to resolve this
issue (GFCI tripping – Nuisance tripping is not covered under warranty)
Below is a way of resolving the GFCI tripping issue on units that are just
being started up or have been sitting for a length of time:
- Fill each Hot food well up with roughly 1.5” -2” of water (where applicable).
- Flip the On/Off switch to the “On position” and turn the first [2] wells to the # 1 position. The orange light will appear for each well-lit.
- Wait 5 minutes and turn the next [2] wells to the # 1 position. The orange light will appear for each well.
- Wait another 10 minutes and rotate the dial to the # 2 position for all wells.
- Wait another 10 minutes and rotate the dial to the # 3 position for all wells
- Wait another 10 minutes and rotate the dial to the # 4 position for all wells.
- Do NOT go beyond the # 4 position for 20+ minutes if even needed, as that is typically the tipping point.
- If the breaker trips during the process, let the breaker sit for a few minutes and then reset it. Turn the dial back 1-2 positions and restart the process over
PAGE LEFT INTENTIONALLY BLANK
DELFIELD
980 SOUTH ISABELLA ROAD, MOUNT PLEASANT, MI 48858
800-733-8821
WWW.DELFIELD.COM
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>