COMPONENTS AND STRUCTURE
- Lamp base
- Lamp holder
- Glass
- Sensor
SPECIFICATIONS
SPECIFICATIONS
Lantern Wall Lamp
Model| BDDLD-A
Luminaire Location| SUITABLE FOR WET LOCATIONS
Dimensions (LxHxW)| 154x357x183 mm/6.06×14.06×7.21 in
Weight| 1.1kg / 2.43lb
OPERATION INSTRUCTIONS
Remote control function
NOTE: The light is with a memory function. If the light is NOT turned
on by the remote controller (such as turned on the light by the switch at
home), it will stay at your last setting mode (such as DUSK to DAWN mode).
If the light is turned on by pressing ‘ON’ button on the remote control. The
light will be SWITCH CONTROLLED mode, which means the light will stay on all
day.
ON button: Light is turned on, and light will stay on all day. Light will not
enter DUSK to DAWN mode.
Off button: Light is turned off D2D mode
-
Press ‘D2D’ button, the light will flicker one time, then enter the DUSK to DAWN mode, the default mode is the SUNSET mode, without timing function.
-
Timer Function
When pressing the 2H button, the light will flicker one time, and the light will automatically turn off after 2 hours;
When pressing the 4H button, the light will flicker one time, and the light will automatically turn off after 4 hours;
When pressing the 6H button, the light will flicker one time, and the light will automatically turn off after 6 hours;
When pressing the 8H button, the light will flicker one time, and the light will automatically turn off after 8 hours;
When pressing the 12H button, the light will flicker one time, and the light will automatically turn off after 12 hours;
The timer function automatically work every day after pressing 2H/4H/6H/8H/12H button. It
means that the light will turns off after it staying on 2/4/6/8/12 hours every day. no need to repeatedly set the timing function unless you want to change the timer.
Note: Under SWITCH CONTROLLED mode, there is no timing function. -
Cancel the timer function:
Press the ‘ESC’ button, and the light will flicker three times, indicating the cancellation of the timer function. -
Illumination adjustment:
Press the Dusk button, and the light will flicker one time: it will automatically light up at dusk (40-60LUX) every day;
Press the Sunset button, and the light will flicker one time: it will automatically light up in the sunset (20-40LUX) every day;
Press the Night button, the light will flicker one time: it will automatically light up in the night (3-10LUX)every day;”
Note: Under Dusk to Dawn mode, when the brightness of the external environment reaches more than 100lux, the light will be off. (the light will be turned off after a one-minute delay)
PREPARATION
NOTE:
Before beginning assembly of product, make sure all parts are present. Compare
parts with parts list. If any part is missing or damaged, do not attempt to
assemble the product.
Estimated Assembly Time: 30-60 minutes.
Recommended to be installed on the ground above 1.2m (3.94 ft) and no higher
than 5 m (16.4 ft).
Product appearance may vary from image shown.
TOOLS REQUIRED (not included)
SAVE THESE INSTRUCTIONS
WARNING:
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION
CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT
AND THE HAZARDS INVOLVED.
CAUTION:
PLEASE MAKE SURE YOUR WALL SWITCH AND POWER AT MAIN CIRCUIT BREAKER BOTH ARE
OFF.
IF IN DOUBT ABOUT ELECTRICAL INSTALLATION, CONSULT A LICENSED ELECTRICIAN.
RISK OF SHOCK:
BEFORE BEGINNING INSTALLATION, TURN OFF ELECTRICITY AT THE CIRCUIT BREAKER BOX
OR THE MAIN FUSE BOX.
NOTE:
BE SURE TO USE WIRE NUTS/CONNECTORS RATED FOR THE CORRECT GAUGE AND NUMBER OF
WIRES USED.
MAKE SURE THERE ARE NO EXPOSED WIRE BUNDLES OUTSIDE THE WIRE NUT/CONNECTOR (IF
APPLICABLE).
BE CAREFUL NOT TO DAMAGE OR CUT THE WIRE INSULA-TION (COVERING) DURING
INSTALLATION. DO NOT LET THE WIRES TOUCH ANY SHARP EDGES.
WARNING:
DO NOT CONNECT THIS LIGHT FIXTURE TO AN UNGROUNDED ELECTRICAL SYSTEM. ATTACH
GROUND FIXTURE WIRE TO EITHER GREEN GROUND SCREW ON MOUNTING PLATE OR THE
GROUND WIRE IN THE OUTLET BOX.
INSTALLING THIS LIGHT IN AN UNGROUNDED ELECTRICAL SYSTEM MAY CAUSE THE METAL
PARTS OF THE LIGHT TO CARRY CURRENT IF ANY WIRES OR WIRE CONNECTIONS ARE
DAMAGED OR LOOSE. IN THIS CASE, ANYONE WHO TOUCHES THE LIGHT WILL RECEIVE AN
ELECTRIC SHOCK, RESULTING IN INJURY OR DEATH.
INSTALLATION STEPS
- Pass the long screw through the middle hole of the fixing bracket.
- Fix the bracket to the junction box.
- Wiring.
- Pass the long screw through the light hole to secure the light to the junction box.
- Install the bulb.
TROUBLESHOOTING
Malfunction | Cause | Remedy |
---|---|---|
LED senses a movement, the light does not light up | 1. The light is not |
energized
2. Other surrounding light sources make the light misjudge it as daytime| 1.
Check power-on status
2. Turn off the nearby lights or sensor head to other directions
LED sensor light illuminates during the day| The shadows around the sensor
make it mistakenly think it’s night| Do not cover the sensor head
LED sensor light flashing| 1. Surrounded by other unstable light sources
shining onto the induction
2. The light from the lamp itself is reflected on the sensor| 1. Avoid being
exposed to such light sources 2. Follow the instructions in “LED DUSK TO DAWN
WALL LIGHT – Matters Needing Attention” to readjust the light sensor
REPLACE THE BATTERIES
Replace the batteries of the remote control by referring to the figure on the right.
HK Bright International Lighting Co., Limited
Unit 616, 6/F., Kam Teem Industrial Building, 135
Connaught Road West, Sai Wan Hong Kong
Manufacturer/Hersteller: MDH LIGHTING LTD
Suite 302, 292 Strovolos Avenue, 2048 Strovolos Nicosia,
Cyprus
UK Importer: MDH LIGHTING LTD
69 Aberdeen Avenue, Cambridge CB2 8DL,
United Kingdom