PowerQuest 707 EU Features
- 45 Amps peak Transient Power Correction (up to 25 mS)
- Ultra-Linear Differential Filter: 8kHz – 1GHz (well in excess of 22dB)
- Ultra-Linear Common-Mode Filter: 30kHz – 100MHz (well in excess of 22dB)
- Both filters linearized for (rising) line impedance with frequency from 0.05 Ohms (source) and 10 to 50 Ohms load (system current dependent)
- Non-Sacrificial Surge Suppression (will withstand multiple strikes of 6000V or 3000A without damage)
- Extreme Voltage Shutdown: 270VAC. Will activate main circuit relay in under 0.25 seconds. Automatically resets once incoming voltage is within a safe range
- (3) High-Current spec-grade outlets; (4) Ultra-Linear Filtered Source outlets
- Detachable 2-meter PowerQuest PQ-716 AC cord featuring ZERO-Tech and RF/ND-Tech
- Ultra-low impedance magnetic circuit breaker/power switc
- Maximum Input Current Capacity: 10A RMS
- 2RU rack mountable metal chassis (rack ears included)
Introduction
The science of AC power is not simple; it demands focus, and the devil is in the details. In fact, the mammoth increase in airborne and AC-line-transmitted radio signals, combined with overtaxed utility lines and the ever-increasing demands from high-definition audio/video components, has rendered our utilities’ AC power an antiquated technology.
Where Alternating Current (AC) is concerned, we’re relying on a century-old technology created for incandescent lights and electric motors—technology that was certainly never meant to power the sophisticated analog and digital circuits used in premium audio/video systems. To properly accommodate the promise of today’s ever-increasing bandwidth and dynamic range, we must achieve extraordinarily low noise across a wide range of frequencies.
Further, today’s power amplifiers are being taxed for instantaneous peak- current demand, even when they’re driven at modest volumes. Although we have seen a substantial increase in both dynamics and bass content from our audio software, the loudspeakers we employ to reproduce them are no more efficient than they were two to four decades ago. This places great demands on an amplifier’s power supply, as well as the source AC power supplying it.
Our systems’ sensitive components need better alternating current—a fact that has resulted in a host of AC power conditioning, isolation transformers, regeneration amplifiers, and battery back-up system topologies. Through differential sample tests and spectrum analysis, it can be proven that up to a third of a highresolution (low-level) audio signal can be lost, masked, or highly distorted by the vast levels of noise riding along the AC power lines that feed our components. This noise couples into the signal circuitry as current noise and through AC ground, permanently distorting and/or masking the source signal.
All sincere attempts to solve this problem must be applauded since once the audio/video signal is gone, it’s gone forever…
For AudioQuest, honoring the source is never a matter of simply using premium
“audiophile-grade parts” or relying on a proprietary technology—common
approaches used within the audiophile market. For years, we have all been
witness to the same, seemingly endless audiophile debates: Valves versus
transistors. Analog versus digital. Can cables really make a difference? The
debates go on and on. While we, too, can brag about our many unique
technologies, we realize that true audio/video optimization is never a matter
of any one secret or exotic circuit. When it comes to noise dissipation for AC
power, many approaches can yield meaningful results. However, they may also
impart ringing, current compression, and non-linear distortions that are worse
than the disease.
The PowerQuest 707 EU uses the widest bandwidth-linearized noise-dissipation
circuit in its class. Our unique passive/active Transient Power Correction
Circuit features an instantaneous current reservoir of over 45 amps peak,
specifically designed for modern current-starved power amplifiers. Most AC
power products featuring “high-current outlets” merely minimize current
compression; the PowerQuest 707 EU works to correct it.
Though it’s easy to boast, it’s quite another thing to create a solution that
is consistent, holistic, functional, and that honors verifiable science. It’s
not enough to reduce AC line noise and its associated distortions at just one
octave, thus leaving vulnerable the adjacent octaves and octave partials to
noise, resonant peaking, or insufficient noise reduction. Consistency is key.
We should never accept superior resolution in one octave, only to suffer from
masking effects a half-octave away and ringing artifacts two octaves from
there. This is the principal criterion for all AudioQuest’s AC power products.
The PowerQuest 707 EU represents over 25 years of exhaustive research and
proven AC power products designed for audiophiles, broadcast engineers, and
professional audio applications. We welcome you to experience the PowerQuest
707 EU and hear firsthand the remarkable results of highly optimized power
management.
—Garth Powell, Senior Director of Engineering, AudioQuest
Installation | Unpacking
Before unpacking your PowerQuest 707 EU, inspect the carton for any obvious
damage to the boxes and internal protective materials. If internal damage is
likely, contact the carrier who delivered the unit.
If shipping damage is evident on the product, then please contact your
shipping carrier. Please save all shipping and packing materials. Should you
move or otherwise need to transport your PowerQuest 707 EU, these packing
materials will ensure the safest transportation. The carton should contain the
PowerQuest 707 EU (220-240V Schuko AC Outlets), two foam inserts, owner’s
manual, rack-mount kit, and 2m PowerQuest PQ-716 AC power cord. Registration
is recommended. In the event that your original ownership documents are lost,
your registration can be used to establish whether the unit is within the
warranty period.
Safety Information | Warnings
Before operating the PowerQuest 707 EU, please read and observe all safety and
operating instructions.
Retain these instructions for future reference.
- Do not disassemble or in any way modify the PowerQuest 707 EU. There are no user-serviceable parts inside.
- Keep away from moisture and avoid excessive humidity.
- Do not allow liquids or foreign objects to enter the unit.
Servicing | Return to AudioQuest
Servicing of the PowerQuest 707 EU must be performed by AudioQuest, and is
only required when:
- The PowerQuest 707 EU has been exposed to rain, flooding, or extreme moisture.
- The PowerQuest 707 EU does not appear to operate normally. (See “Trouble-Shooting Guide.”)
- The PowerQuest 707 EU has been dropped and sustained considerable physical damage.
If sending the PowerQuest 707 EU to AudioQuest for servicing (or shipping it
for any reason), please use the factory-approved packaging materials. If you
have lost any of these (carton, two foam inserts, one poly bag), please
contact AudioQuest for eplacements. We will provide replacement packaging
materials for a nominal charge; shipping costs will be paid by the individual
or company requesting the packaging material. Please do not rely on other
methods of packaging, including those provided or suggested by
packaging/mailing stores. These methods and materials could seriously damage
the product, as well as its finish. Even the loss of the thick polybag is
enough to permanently damage the finish during transport. If you have lost the
original packaging material, please request replacement materials from
AudioQuest.
Power Source
Ideally, the power source to which the PowerQuest 707 EU is connected should
be adequate for use at 220- 240V single phase nominal voltage, 10 amps
(current capacity RMS or greater).
For proper operation, the PowerQuest 707 EU requires a safety ground (supplied
via the power utility AC wall outlet).
Placement
The PowerQuest 707 EU is manufactured with four rubber textured polymer feet
for safe, secure placement on any table, cabinet, shelf, or floor. When rack-
mounting is required, these feet may be removed with a standard Phillips
screwdriver. Placement or proximity to other components is not critical, and,
under standard use, the PowerQuest 707 EU does not produce any appreciable
heat. The PowerQuest 707 EU may be rack-mounted in a standard 19” rack by
attaching the included 2-RU rack ears. To attach the optional rack ears to the
PowerQuest 707 EU chassis, first remove the three Phillips flathead screws
from the front portion of both the left and right sides of the cover assembly.
Next, mount the rack ears flush against the back of the PowerQuest 707 EU’s
front panel. Finally, secure the rack ears into place by installing the
rackmount kit’s Phillips pan head screws.
When tight installations do not provide adequate room in a rack, shelf, or
cabinet, the PowerQuest 707 EU can be placed on its side. Such placement will
pose no safety or performance compromises, but we recommend placing a soft
towel or carpet under the unit to prevent the chassis and front panel from
being scratched or marred in any way.
Connection to Audio/Video Components
AC Cable Routing
Once the PowerQuest 707 EU is placed, a 15-amp-rated (or greater), high-
current AC cord must be connected to the rear-panel AC inlet (IEC-C14)
connector. The AC cord must have an IEC-C13 female end connector and a
grounded male 220-240VAC Edison/NEMA plug. We highly recommend the use of the
supplied PowerQuest PQ-716 AC cord or any AudioQuest NRG-Z, Wind Series, or
High-Current Storm Series AC cable. When facing the PowerQuest 707 EU’s rear
panel, the IEC-C14 inlet is located on the unit’s lower-left side. The AC
inlet cord must be connected to an appropriate AC outlet (see “Power Source”).
Whenever possible, it is best to keep at least three inches (approximately
7cm) between AC cables and any signal cable. When this is not possible in a
practical layout of system cabling, crossing the AC cables to signal cables at
90 degrees is best to minimize induced noise.
High-Current | Low-Z Power Outlets
There are three High-Current/Low-Z Power outlets (labeled “1” through
“3”—three discrete outlets in all). These outlets feature our Transient Power
Correction Technology (45 amps peak – up to 25 mS duration) and are designed
to enhance the performance of power amplifiers via our circuit’s low-impedance
transient current reservoir. Power amplifiers, monoblock amplifiers,
integrated amplifiers, powered receivers, or powered subwoofers should be
connected to these outlets.
Regardless of class of operation or circuit topology (valve, solid-state,
digital, or otherwise), the Transient Power Correction Circuit will not
compress the current of any power amplifier. Quite to the contrary, it will
improve the amplifier’s performance by supplying the low-impedance current
source that the amplifier’s power supply so desperately needs.
However, the other four AC outlets (Ultra-Linear Noise-Filtering), are not
optimized for most power amplifiers. They have been optimized for line-level
audio preamplifiers, DACs, universal players, turntables, and video products
that utilize constant-current voltage amplifier circuits. These circuits never
suffer from current compression, but their lower input level and higher gain
require a more robust means of noise dissipation. This is key to the
PowerQuest 707 EU’s discrete AC power banks, in that not every circuit is
treated the same, but rather isolated bank by bank and optimized for best
performance.
Ultra-Linear Filtered Power Outlets
There are four outlets (4 discrete outlets in all, labeled “4” through “7”)
that utilize this technology within the PowerQuest 707 EU. All four of these
are in turn isolated from the High-Current/Low-Z outlets, labeled 1 through 3.
This offers a great advantage in controlling the complex interactions of RF
(radio frequency) and other induced noises present in the AC power supplied
from your utility, the noise that will be present on and in every AC cord, and
the noise that is produced within your system’s components and that
“backwashes” into the PowerQuest 707 EU’s output circuits.
Though it would be simple to recommend putting the digital or video components
into outlets 4, 5 and the line-level audio components and turntables into
outlets 6 and 7, the quest for optimal performance is more complex. This
scenario will work, and likely work well, but a certain amount of
experimentation is best given the fact that no filter can eliminate 100% of
all noise. The size of many of these RF-induced waveforms possess sinewaves as
small as the edge of a piece of paper, and the interactions are complex. So
long as the power amplifiers are in their appropriate outlets (1 through 3),
and the other components are in outlets 4 through 7, you should experience
exemplary performance.
Suggested AC Connections
Note: Outlets 4 through 7 are subject to many variables and circuit conditions, so experimentation for best results is encouraged. Power amplifiers must be connected to outlets 1 through 3.
Operation and Continuous Use
Power Switch | Circuit Breaker and LED Power Indicator
Once the AC cords are properly connected to the AC source tap, and the
components are connected to the appropriate outlet banks, it is safe to
energize the PowerQuest 707 EU. On the right-hand side of the PowerQuest 707
EU’s front panel, there is a black rocker switch. Firmly press the rocker
switch so that its upper portion is flush with the front panel. Typically,
within a couple of seconds, you should hear an audible “clack” sound(s) from
one or more relays within the PowerQuest 707 EU. At the same time, the front-
panel LED power indictor will glow green, signifying that the unit is
operational. (If this does not occur, see the “Trouble-Shooting Guide” in this
manual.)
PowerQuest 707 EU Current Draw
The Transient Power Correction Circuit creates a reactive current draw of as
much as 3 to 4 amps RMS at idle (real-world draw is a small fraction of an
amp), and electrical technicians who connect a current probe to a product such
as this are frequently alarmed: They suspect that the product is either broken
or that it is drawing a distressingly high amount of current from the wall
outlet (akin to an AV receiver left in full operational mode).
This is far from the truth. If the PowerQuest 707 EU was consuming that much
current (or even 30% of that level), it would need to dissipate the energy
loss in heat. It would be quite warm (even hot) to the touch, just like most
power amplifiers while in operation. In fact, the PowerQuest 707 EU runs
cool, precisely because this current reading is false. The circuit utilizes
massive capacitive reactance across the AC line, which, akin to a battery,
will both absorb and immediately release the current several times per second.
Further, when incorporated with power supplies such as those found in power
amplifiers, the current readings actually come down. This is due to what’s
known as a vector load, and it’s quite dynamic in an audio/video system.
In this scenario, there is one thing that can run somewhat warmer than it
might otherwise: the AC cord that supplies power to the PowerQuest 707 EU.
This is because the wiring and the circuit breaker that supply power to
PowerQuest 707 EU simply look at RMS current and do not distinguish between
reactive loads, resistive loads, or inductive loads, but your utility does.
This circuit and many like it have been utilized for many years, and, when
tested into buildings with absolutely no loads present aside from the
transient power correction circuit, there was virtually zero power draw from
the utilities’ power meter. Still, in an age where so-called “smart meters”
are omnipresent, and some utilities may or may not change their standards for
“what type of power or current is suitable for billing,” we have gone to great
lengths to offer an alternative to those who may be concerned, but who
nevertheless wish to achieve the best possible audio/video performance.
Overvoltage Protection Indicator
One portion of the PowerQuest 707 EU’s non-sacrificial surge protection is
dedicated to a fast-acting extreme voltage shutdown circuit. If more than
270VAC is present on the incoming AC line for more than a quarter of a second,
the circuit will instantly open a high-current relay that will disengage the
AC power from all the PowerQuest 707 EU’s AC outlets, activating the red
front-panel LED “Overvoltage Protection” warning indicator. Once the event has
passed, or the building wiring fault has been corrected, the circuit will
automatically re-engage.
Break-in Time | Continuous Use
The PowerQuest 707 EU is made of a variety of passive and active components.
As such, the PowerQuest 707 EU will benefit from continuous use, just like any
other audio/video component. This is not to say that you will be made to
“suffer” through weeks or months of intolerable performance until that “magic
day” when the parts are fully formed and ready. On the contrary, the
PowerQuest 707 EU will perform very well from the first moment you use it. It
will improve gradually, in small increments, over a period of approximately
two weeks. While leaving the PowerQuest 707 EU turned on during this period
will aid the process, it is also perfectly acceptable to turn the unit off;
doing so will simply increase the time it takes to reach final “break-in.”
The PowerQuest 707 EU has a 5-year warranty, but it was designed to last for
over two decades. Provided that the PowerQuest 707 EU is used inside a home,
store, studio, or office with a reasonable climate (7 degrees to 38 degrees
Celsius, with less than 20% humidity), it can be left on continuously; there
are no parts that will wear out.
Specifications
PowerQuest 707 EU
- Surge Suppression: Non-sacrificial (nothing to damage with repeated 6000V/3000A input surge tests, which is the maximum that can survive through a building’s AC electrical panel).
- Extreme Voltage Shutdown Voltage: 270VAC (will activate the main high-current relay to open within less than 0.25 second; automatically resets once the incoming power is within a safe range).
- Differential-Mode Noise Filtering: Well in excess of 22dB from 8kHz to 1GHz, linearized for dynamic (rising) line impedance with frequency (source) and 10- to 50-ohm load, system current dependent.
- Common-Mode Noise Filtering: Well in excess of 22dB from 30kHz to 100MHz, linearized for dynamic (rising) line impedance with frequency (source) and 10- to 50-ohm load, system current dependent.
- Maximum Input Current Capacity: 10 amps RMS
- 7 AC Outlets: 3 High-Current/Transient Power Correction; 4 Ultra-Linear Filtering.
- Power Consumption: Typically, less than 0.5 amps at 220-240 VAC input, with all connected components operational. (This is dependent on a reactive vector load. For more info, see “Operation and Continuous Use: PowerQuest 707 EU Current Draw.”)
- Dimensions: 43.0 cm W x 8.6 cm H (9.4 cm w/ feet attached) x 38.0 cm D (2-RU rack-mounting ears are provided)
- Weight: 7.6 Kg.
PowerQuest PQ-716 AC Power Cable (2m | 6’7”)
- 2.5 mm2 | 16A RMS capacity @ 220-240V 50Hz; NEMA male wall plug and IEC C-13 female connector
- Semi-Solid Concentric Long-Grain Copper (LGC) Conductors
- ZERO-Tech (No Characteristic Impedance) for uncompressed current transfer
- RF/ND-Tech minimizes circuit misbehavior by cancelling induced RF noise
- Direction-Controlled Conductors ensure induced noise is properly drained and dissipated
Trouble-Shooting Guide
At AudioQuest, we always appreciate hearing from you. However, if you have
questions, problems, or suspect that your PowerQuest 707 EU requires service,
please start here.
There is no power to any of the AC outlets.
When the PowerQuest 707 EU’s front-panel LED power indicator glows green,
the unit is operational. If the Protection On indicator is not lit, consider
the following:
- Is the upper portion of the front-panel rocker switch fully flush with the chassis?
- Is the input AC cord fully inserted into the PowerQuest 707 EU’s AC inlet?
- Is the input AC cord properly plugged into the wall AC service outlet?
- Is the wall’s AC outlet functioning properly?
Plug into the outlet another component, product, or lamp to verify that power
is present, and that the electrical panel’s circuit breaker has not tripped.
If there are only one or two AC outlets that have no output power, a component
may be malfunctioning. Verify the AC output with a known simple device such as
a lamp.
There is no power to any of the AC outlets and the red front-panel
Overvoltage Protection indicator is lit.
This indicates that either there is more than 270VAC (+/-5V) present on the
wall’s AC service outlet, or the PowerQuest 707 EU’s protection circuit is
mis-calibrated. The latter is quite rare. (This circuit is adjustable, but
it’s tested and retested before it leaves the factory, and it’s glued into
place, so shipping will not affect it.) Use an AC voltage meter to determine
if your outlet has too much voltage to be safe for operation, or if there is a
wiring fault that is causing this to occur.
Once the power is brought into a safe range for operation (180VAC to 265 VAC),
the PowerQuest 707 EU’s protection circuit will automatically switch to
operational mode and the green power indicator will light.
The main power rocker switch/circuit breaker tripped to the lower (off)
position while the system was playing.
You may have exceeded the maximum current capacity of the PowerQuest 707 EU.
This should be rare, but it may be possible. Typical power amplifiers draw
about one-third of their maximum current consumption at 220-240VAC, as listed
in the product’s specifications (typically found in their owner’s manual).
This is further complicated by the fact that the power consumption to all AC
outlets (1 through 7), is a cumulative draw on the maximum current capacity of
10 amps that will trip this power switch/magnetic circuit breaker.
The Transient Power Correction Circuit may also contribute to the overall draw
seen by the circuit breaker. Still, it should be rare that the total capacity
is exceeded, but, given that some televisions, projectors, and power
amplifiers can draw substantial current, it is certainly not impossible. If
this is the case, an additional PowerQuest 707 EU, and a discrete 16-amp AC
service on the same phase of the electrical panel, will be required for some
or all the power amplifiers.
A technician or electrician found that my PowerQuest 707 EU consumes over 3
amps of current. Is it broken?
No, it’s not broken, and it’s not drawing 3+ amps in any conventional sense.
The PowerQuest 707 EU’s Transient Power Correction Circuit creates a reactive
current draw of as much as 3 to 4 amps RMS at idle, and, when incorporated
with power supplies such as those found in power amplifiers, the current
readings decrease. This is a vector load, which will vary with the connected
equipment. When plugged into an AC service that has no other electrical draw,
it is typical to see a real-world RMS power draw well below 60
watts at idle.
My home or grounds were hit by lightning. The PowerQuest 707 EU seems to
be functioning properly. Should it be sent in for inspection or service?
If you see or smell smoke coming from the unit, it needs service. Otherwise,
if it functions after such an event (which is very likely), there is nothing
that would be compromised or damaged. If it fails after such anevent, it will
fail totally. However, it’s unlikely that this would occur. The circuit is
designed to easily handle any voltage or current surge that could possibly
make it past an electrical panel. The force required to damage the PowerQuest
707 EU via a power surge would melt the panel and burn the building (in which
case, the PowerQuest 707 EU is the least of your worries).
How do I clean the chassis?
The PowerQuest 707 EU’s black-painted chassis and black anodized front panel
can be cleaned with AudioQuest CleanScreen, or a modest misting of household
window cleaners. Please use soft cotton or wool toweling to remove the liquid
from the metal and painted surface. Never use alcohol or solvent-based
cleaners. They can damage the surfaces, paint, and silk-screening material.
I hear a slight buzzing sound coming from the PowerQuest 707 EU. Is it
damaged?
No, it’s not damaged (or, at least, damage is very unlikely). If you’re in an
extraordinarily quiet room and you hear this faint buzzing sound only when in
relatively close proximity to the PowerQuest 707 EU, or only when you place
your ear next to the unit, the buzzing is normal and, unfortunately, cannot be
entirely eliminated.
What you are experiencing is a variation on the effect called
magnetostriction. When an extraordinarily high quantity of harmonic distortion
is present on an AC line, a portion of the Transient Power Correction circuit
that is hermetically sealed and damped can mechanically buzz as its internal
electrical plates resonate at 50 Hertz and many octaves above. In order to
reduce or eliminate this harmonic distortion, the circuit is trying to turn
this distortion into heat. This has no effect on the performance or longevity
of the PowerQuest 707 EU or its connected components.
Warranty
The Quest Group, DBA: AudioQuest, warrants to the original purchaser of this
AudioQuest PowerQuest 707 EU, will be free from defects in material and
workmanship for a period of one year. The purchaser of the product is allowed
30 days from the date of purchase to complete the warranty registration online
at the AudioQuest website: https://www.audioquest.com/page/aq-product-
registration.html. If the purchaser completes the aforementioned
registration, the warranty period will be increased to five years from the
date of purchase.
If the product does not conform to this Limited Warranty during the warranty
period (as herein above specified), purchaser shall notify AudioQuest in
writing (or e-mail), of the claimed defects. If the defects are of such type
and nature as to be covered by this warranty, AudioQuest shall authorize the
purchaser to return the product to the AudioQuest factory (2621 White Road,
Irvine, California, 92614 USA). Warranty claims should be accompanied by a
copy of the original purchase invoice showing the purchase date; this is not
necessary if the Warranty Registration was completed by registering online at
the AudioQuest website.
Shipping charges to the AudioQuest factory (Irvine, California, USA) must be
prepaid by the purchaser of the product. AudioQuest shall, at its own expense,
furnish a replacement product or, at AudioQuest’s option, repair the defective
product. Return shipping charges back to the purchaser will be paid by
AudioQuest. All warranties contained herein are null and void if: the
AudioQuest AC power product has been opened, improperly installed, altered in
any way, or tampered with. AudioQuest is not responsible for any connected
equipment or any claims of damage to connected equipment due to the occurrence
of an AC power surge, spike, or over-voltage event, unless AudioQuest
determines after thorough inspection and testing by AudioQuest (with product
shipped to AudioQuest USA at the owner’s expense), that the protection
circuitry was in whole or in part improperly functioning. AudioQuest is not
responsible for any connected equipment that is damaged due to external signal
lines (non-AC power lines), that carry an electrical storm or signal wiring
fault surge or spike (such as Ethernet, cable, and satellite connections). All
AudioQuest AC power products, must be plugged directly into a properly wired
AC power line with a protective ground.
AudioQuest AC power products cannot be “daisy-chained” together in serial
fashion with other AC power strips, UPS devices, other AC surge protectors, AC
power conditioners, three-to-two prong adapters, or AC extension cords. Any
such installation voids the warranty. The AudioQuest warranty only protects
against damage to properly connected equipment or AC cables where AudioQuest
has determined, at its sole discretion, that the damage resulted from an
AudioQuest power product circuit or protection circuit malfunction and does
not protect against acts of God (other than lightning, such as flood or
earthquake), war, terrorism, vandalism, theft, normal use wear and tear,
erosion, depletion, obsolescence, abuse, damage due to low-voltage
disturbances (i.e., brownouts or sags), or system equipment modification or
alteration. Do not use this product in any way with a generator, heater, sump
pump, water-related devices, lifesupport devices, medical devices, automobile,
motorcycle, or golf-cart battery charger.
To be used indoors only and in dry areas. All warranties contained herein are
null and void if used in any way with any of the aforementioned devices.
THE FOREGOING IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. AudioQuest does not warrant against damages
or defects arising out of improper or abnormal use or handling of the product,
against defects or damages arising from improper installation, against defects
in products or components not manufactured by AudioQuest, or against damages
resulting from such non-AudioQuest made products or components. This warranty
shall be cancelled by AudioQuest at its sole discretion if the product is
modified in any way without written authorization from AudioQuest. This
warranty also does not apply to products upon which repairs have been affected
or attempted by persons other than pursuant to written authorized by
AudioQuest.
THIS WARRANTY IS EXCLUSIVE. The sole and exclusive obligation of AudioQuest
shall be to repair or replace the defective product in the manner and for the
period provided above. AudioQuest shall not have any other obligation with
respect to this product or any part thereof, whether based on contract, tort,
strict liability, or otherwise. Under no circumstances, whether based on this
Limited Warranty or otherwise, shall AudioQuest be liable for incidental,
special, or consequential damages. AudioQuest employees or representatives’
ORAL OR WRITTEN STATEMENTS DO NOT CONSTITUTE WARRANTIES, shall not be relied
upon by purchaser, and are not a part of the contract for sale or this Limited
Warranty. This Limited Warranty states the entire obligations of AudioQuest
with respect to the product. If any part of this Limited Warranty is
determined to be void or illegal, the remainder shall remain in full force and
effect.
Warranty claims should be accompanied by a copy of the original purchase
invoice showing the date of purchase. (If the product was registered online,
this is not necessary.) Before returning any equipment for repair, please be
sure it is adequately packed and cushioned in either the original or a new
AudioQuest factory-supplied polybag, foam insert pair, and dual carton set to
protect against damage in shipment, and that it is insured.
©2023 AudioQuest • California, USA
The Netherlands • www.audioquest.com
Email: info@audioquest.com
Designed and Engineered in USA
Manufactured in China
References
- PowerQuest® Series · AC Power Conditioners · AC Power · AudioQuest
- AudioQuest
- Product Registration · AudioQuest
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>