Features
- Constant Current mode output
- Circular shape PCB type design
- Built-in active PFC function
- Function options: output adjustable via potentiometer; 3 in 1 dimming; DALI
- Typical lifetime>50000 hours
- 5 years warranty
Applications
- LED bay lighting
- LED down lighting
- LED spot lighting
- LED mining lighting
- LED stage lighting
Description
HBG-100P seriesis a 100W AC/DC PCB type LED driver featuring the circular
shape design. It operates from 90~305VAC and offers constant current output
models with different ratedvoltage ranging between 36V and 60V. Thanks to the
high efficiency up to 91.5%, with thefanless design, the entire series is able
to operate for -40°C ~ +45°C under free air convection. HBG-100P is equipped
with various function options, such as dimming methodology, so as to provide
the optimal design flexibility for LED lighting system.
Model Encoding
Type | Function | Note |
---|---|---|
A | lo adjustable through built-in potentiometer. | ln Stock |
B | 3 in 1 dimming function (1~10Vdc, 10V PWM signal and resistance) | ln Stock |
DA | DALl control technology. | ln Stock |
SPECIFICATION
MODEL | HBG-100P-36 | HBG-100P-48 | HBG-100P-60 |
---|---|---|---|
**OUTPUT** | RATED CURRENT | 2.7A | 2A |
RATED POWER | 97.2W | 96W | 96W |
CONSTANT CURRENT REGION Note.2 | 21.6 ~ 36V | 28.8 ~ 48V | 36 ~ |
60V
OPEN CIRCUIT VOLTAGE (max.)| 37V| 49V| 62V
CURRENT ADJ. RANGE| Adjustable for A-Type only (via built-in
potentiometer)
1.62 ~ 2.7A| 1.2 ~ 2A| 1.0 ~ 1.6A
CURRENT RIPPLE| 5.0% max. @rated current
CURRENT TOLERANCE| ±5.0%
SET UP TIME Note.4| 2000ms / 115VAC 500ms / 230VAC
**INPUT| VOLTAGE RANGE Note.3| 90 ~
305VAC 127 ~ 431VDC(Please refer to “STATIC CHARACTERISTIC”
section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF≧0.96/115VAC, PF≧0.96/230VAC, PF≧0.94/277VAC@full
load(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION| THD< 20%(@load≧60%/115VC,230VAC;
@load≧75%/277VAC)(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
EFFICIENCY (Typ.) Note.5| 91%| 91%| 91.5%
AC CURRENT| 1.1A / 115VAC| 0.5A / 230VAC| 0.45A / 277VAC|
INRUSH CURRENT(Typ.)| COLD START 60A(twidth=550μs measured at 50% Ipeak)
at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 4 units (circuit breaker of
type B) / 8 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
NO LOAD / STANDBY POWER CONSUMPTION| Standby power consumption <0.5W for
B/DA-Type A-Type please refer to Note. 7
****PROTECTION| OVER CURRENT| 95 ~ 108%
Constant current limiting, recovers automatically after fault condition is
removed
OVER VOLTAGE| 41 ~ 49V| 54 ~ 63V| 65 ~ 75V
Shut down o/p voltage, re-power on to recovery
OVER TEMPERATURE Note.11| Shut down o/p voltage, re-power on to
recovery
****ENVIRONMENT| WORKING TEMP.| Ta=-40 ~ +45℃ (Please refer to
“ OUTPUT LOAD vs TEMPERATURE” section)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 45℃)
VIBRATION| 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X,
Y, Z axes
****SAFETY & **EMC| SAFETY STANDARDS| UL8750,CSA C22.2
No.250.13-12; ENEC BS EN/EN61347-1,BS EN/EN61347-2-13,BS EN/EN62384,
GB19510.1, GB19510.14,EAC TP TC 004 approved
DALI STANDARDS| Compliance to IEC62386-101, 102, 207 for DA-Type only
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC| I/P-FG:2KVAC| O/P-FG:0.5KVAC|
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C
(@load ≧60%) ; BS EN/EN61000-3-3, GB17743, GB17625.1,EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN61547,light industry level(surge immunity:Line-Earth:4KV, Line-
Line:2KV),EAC TP TC 020
**OTHERS| MTBF| 346.8Khrs min. MIL-HDBK-217F (25℃)
DIMENSION| Refer to mechanical specification
PACKING| 0.3Kg; 45pcs/14.5Kg/1.60CUFT
NOTE**|
- All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- Please refer to “DRlVlNG METHODS OF LED MODULE”.
- De-rating may be needed under low input voltages. Please refer to Static Characterless sections for details.
- Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- The DA type power supply is less efficient than the typical efficiency in specification by 1%
- The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
- To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains
- This series meets the typical life expectancy of >50,000 hours of operation when Ta is about 45℃ or less.
- Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- All functional testing must be filled with potting,including OTP function .※ Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
BLOCK DIAGRAM
DRIVING METHODS OF LED MODULE
This series works in constant current mode to directly drive the LEDs.
Typical output current normalized by rated current (%)
Typical output current normalized by rated current (%)
3in 1 dimming function (for B-Type)
- Output constant currentlevel can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 1~10VDC, or 10V PWM signal or resistance.
- Direct connecting to LEDs is suggested. Itis not suitable to be used with additional drivers.
- Dimming source current from power supply: 1004A (typ.)
pplying additive 1~ 10VDC
pplying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):
**Applying additive resistance:
Note:** In the case of turning the lighting fixture down to 0% brightness,
please refer to the configuration as follow, or please contact MEAN WELL for
other options.
Using a switch and relay can turn ON/OFF the lighting fixture.
DALI Interface (primary side; for DA-Type) –
- Apply DALIsignal between DA+ and DA-.
- DALI protocol comprises 16 groups and 64 addresses.
- Firststeps fixed at 8% of output.
OUTPUT LOAD vs TEMPERATURE
AMBIENT TEMPERATURE, Ta (C)
STATIC CHARACTERISTIC
INPUT VOLTAGE (V) 60Hz
**POWER FACTOR (PF) CHARACTERISTIC
**
TOTAL HARMONIC DISTORTION (THD)
EFFICIENCY vs LOAD
HBG-100P series possess superior working efficiency that up to 91.5% can be
reached in field applications. X 60V Model
LOAD
MECHANICAL SPECIFICATION
Atype
BIDAtype
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>