GATEXPERT SW400DC Swing Gate Opener User Manual

June 13, 2024
GATEXPERT

GATEXPERT LOGO Swing Gate Opener
User Manual
SW400DC

SW400DC Swing Gate Opener

GATEXPERT SW400DC Swing Gate OpenerGATEXPERT
SW400DC Swing Gate Opener - QR CodeWebsite:www.gatexpertstore.com
E-mail: sales@gatexpertstore.com

WARRANTY

  1. To repair against this warranty card and invoice during the warranty period.
  2. Warranty period: 1 year after the date of invoice.
  3.  Without unauthorized dismantling, any product broken or damage due to quality problem, we’ll offer the repair service for free or replace for free.
  4. The malfunction and damages caused by incorrect use or man fault is not covered by this warranty.

CONTACT US
E-mail: sales@gatexpertstore.com

  • Please fill in the order information in the form below.
  • All personal information you provided will be only used for warranty service and kept strictly confidential.
  • Refer to this list when contacting GATEXPERT for technical service or assistance with your automatic gate opener.
Order Number Product Model Purchase Date Country / Region
Email Address
Issue Details

Dear users,
Thank you for choosing this product. Please read the manual carefully before assembling and using it. Please do not leave out the manual if you send this product to a third party.

Safety Instruction

  • Please read this manual carefully before installation, in which involves with important information about installation、using、maintenance and safety.
  • Any undefined operations under this manual is not allowed, incorrect using may damage  the product even causing the injuries or property losses.
  • To consider the possible danger during the installation or using process of swing gate operator, installation must strictly comply with the construction standard and electrical operating procedure.
  • Before installation, please make sure that the power voltage being used matches with the supply voltage of this product. Please check if the leakage protection switch is installed and the grounding system is correct.
  • Please check if additional equipment or materials are required to meet the specific requirements.
  • The disposal of packaging material must be complying with the local regulation.
  • Please do not change any parts except for those defined under this manual. Any undefined changes may cause the malfunction. Any damages to the product arising therefrom shall be beyond the liability of the company.
  • Please do not leak water or any liquid into the controller or any other open devices. Please disconnect the power immediately if any mentioned cases happened.
  • Please keep this product away from heat and open fire. Or it may damage the components; cause the failure or other hazards.
  • Please make sure there is no vehicles、passengers and objects passing through while the swing gate is moving.
  • Anti-clip equipment like infrared protection switch must be installed to avoid injuries to person and property losses. The company shall not be liable for any damage or accident arising therefrom.
  • The installation、using and maintenance of this product must be carried out by professionals.
  • Children are not allowed be touch the control devices or remote transmitters.
  • A warning sign must be placed somewhere on the swing gate according to the national standard.
  • Please keep this instruction properly for future reference.

Packing List (Standard)

No. Picture Name Quantity
1 Main machine 2
2 Control box 1
3 Manual release bar 1
4 Remote control 2
5 Wall bracket 4
6 Front mounting bracket 2
7 Connecting bracket 2
8 Mounting screw (short) 2
9 Mounting screw (long) 2
10 Screw M8×25 4
11 Nut M8 6
12 Limit stopper 1
13 Spring washer Ø12 2
14 gasket 2

Packing List (Optional)

No. Picture Name Quantity
1 Infrared sensor 1
2 Wireless keypad 1
3 Alarm lamp 1
4 Electric lock 1
5 Storage battery 2

Technical Parameters

Model SW400DC
Power supply 220V/50Hz;110V/60Hz
Motor power 62W
Gate moving speed 22~26s / 90°
Max.single-leaf weight 400kg
Max.single-leaf length 4m
Max.piston stroke 45cm
Max.force 3800N
Remote control distance ≥30m
Remote control mode Single button mode
Storage battery (optional) DC24V (4.5Ah or 9Ah)
Noise ≤60dB
Working duty S2, 30min
Recording of up remote controls 32
Remote frequency 433.92 MHz
Working temperature -20°C – +70°C
Package weight 20kg

Installation

SW400DC swing gate opener is applicable to single leaf gate weight less than 400kg, and the length shorter than 4m. The drive mode adopts the worm and worm gear to combine the screw rod transmission. This gate opener must be installed inside the enclosure or yard for protection.
4.1 Installation Drawing

GATEXPERT SW400DC Swing Gate Opener - Installation
Drawing

  1. Control box
  2. Gate opener
  3. Gate
  4. Alarm lamp (optional)
  5. Infrared sensor (optional)
  6. Limit stopper
  7. Remote control
  8. Wireless keypad (optional)

4.2 Size of Main Machine and Accessories
4.2.1 Size of Main Machine

GATEXPERT SW400DC Swing Gate Opener - Main Machine

4.2.2 Size of Mounting Plate

GATEXPERT SW400DC Swing Gate Opener - Mounting Plate

4.3 Installation Steps
4.3.1 Preparation before Main Machine Installation
a) Before installing the door opener, please confirm that the door were installed correctly, please ensure that the door can be manually operated smoothly, and the door limit stopper can effectively prevent the door to continue moving.
b) Please keep a distance of 40-50mm between the door bottom and the ground for installing the electric lock. If electric lock is not required, the distance between the door bottom and the ground should be ≥20mm;
c) The recommended mounting height of the 2 main machines is around 300 ~ 800mm above the ground, and make sure there are reliable fixed points for mounting brackets.
Cable bury
In order to ensure the normal operation of the door opener and protect the cable from damage, please use two PVC pipes to bury the motor and power cables, and the control cables separately. One PVC pipe for motor and power cables, the other one for control cables.
Mounting brackets fixing
In order to install the SW400DC main machines firmly, it is recommended to use the expansion screws to fix the mounting brackets.
4.3.2 Accessory Installation
a) Before installing the main machines, please install the wall bracket on the wall first, then fix the connecting bracket, finally install the front mounting bracket on the door.
Note: Please detect by gradienter before fixing to ensure that the front mounting bracket and the connecting bracket are in the same level.

GATEXPERT SW400DC Swing Gate Opener - Accessory
Installation

b) The connecting bracket and the wall bracket can be connected according to different conditions, please refer to figure 5.

GATEXPERT SW400DC Swing Gate Opener - Accessory Installation
2

c) Users should prepare power cables for the control box and the main machines by themselves due to the different installation environment. The cores for the control box power supply cable should be more than 3, the cores for the motor cable is 2. If users need to install external accessories like electric lock, infrared sensor, alarm lamp, external button switch etc., please increase the embedded cables accordingly, please make sure the sectional diameter of electric lock cable is over 1.5mm², sectional diameter of other cables is over 0.5mm². The cable length should be determined by users according to their installation situations.
Note: The outlet on the PVC pipe should be downward in order to avoid the rain water flowing into the pipe along the cable.
d) Before the installation, please unlock the two main machines. Unlock method: Remove the cover, insert the manual release bar, rotate the bar until it’s released, as shown in Figure 6, then turn the telescopic arm, you’ll find it is stretched easily.

GATEXPERT SW400DC Swing Gate Opener - cable

4.3.3 Main Machine Installation
Please refer to Figure 7 to fix the tail of the main machine and the connecting bracket with the installation screws, and then manually adjust the telescopic arm to the appropriate length, finally fix the telescopic arm connector and the front mounting bracket with the installation screws. Pull the door after installation to ensure the travel is flexible without jamming.

GATEXPERT SW400DC Swing Gate Opener - Main Machine
Installation

Installation direction: door opens inward

GATEXPERT SW400DC Swing Gate Opener - inward

| A(mm)| B(mm)| C(mm)| D max| L(mm)
---|---|---|---|---|---
SIZE| 240| 115| 15| 100°| 1400
220| 125| 25| 100°| 1440
200| 135| 35| 100°| 1420
180| 145| 45| 90°| 1420

Table 1 Recommended Installation Position
Installation direction: door opens outward

GATEXPERT SW400DC Swing Gate Opener - opens outward

| A(mm)| B(mm)| C(mm)| D max| L(mm)
---|---|---|---|---|---
SIZE| 170| 170| 40| 90°| 1000
180| 170| 30| 100°| 1000
190| 170| 30| 100°| 1000
200| 180| 40| 100°| 1000

Table 2 Recommended Installation Position
Note: Value B must be close or equal to the value A to reach the best mechanical advantage.
4.3.4 Size of Control Box

GATEXPERT SW400DC Swing Gate Opener - Control Box

Warning

  • To ensure safety, please install the limit stopper at the close limit position when the door opens inward (as shown in figure 8).
  • Before installing the main machine, please make sure the main machine and components are in good mechanical performance and the door can be manually operated flexibly.
  • One control unit can optionally drive one main machine or two main machines.
  • Earth leakage circuit breaker must be installed on where the gate movement can be seen, and the minimum mounting height for the control box should be over 1.5m to avoid being touched by kids.
  • After installation, please check whether the mechanical property is good or not, whether gate movement is flexible or not after unlocking, and whether the infrared sensor (optional) is installed correctly and effectively.

Wiring and Debugging

5.1 Wiring Instructions

GATEXPERT SW400DC Swing Gate Opener - Wiring
Instructions

5.2 Control Board Drawing and Instructions

GATEXPERT SW400DC Swing Gate Opener - Control Board
Drawing

Terminal Description
1. AC24VIN 24VAC Power Supply Input
2. +SOLAR- Solar Power Input
3. +BATT- 24V Battery Input
4. FORCE Resistance Force
5. SLOW DOWN Slow Stop Distance
6. SPEED Moving Speed
7. MOTOR1 Motor1 Output
8. MOTOR2 Motor2 Output
9. -ELOCK+ Electric Lock Output
10. -BLK+ Alarm Lamp Output (Note: pay attention to the negative and

positive.)
11. +24V| 24V Output Positive
12. +12V| 12V Output Positive (No output under dormant state)
13. EM1| Motor1 Hall Sensor Power Output
14. LM1| Motor1 Hall Sensor Limit Signal Input
15. EM2| Motor2 Hall Sensor Power Output
16. LM2| Motor2 Hall Sensor Limit Signal Input
17. PH| Photo Sensor Input Active
18. PED| Single Gate/Pedestrian Mode Input Active
19. OSC| Single Channel Input Active
20. ANT| Antenna
21. COM| Common
22. SIG| The signal is normally closed only after the door is in place

Photo Seneor Wiring Instructions

GATEXPERT SW400DC Swing Gate Opener - Photo Seneor
Wiring

WIFI Module Wiring Instructions

GATEXPERT SW400DC Swing Gate Opener - WIFI Module
Wiring

5.3 Digital Screen Setting
When the control board is working, the users can check working state of gate opener by digital screen on the control board.
: no input;
: under opening state;
: under closing state;
:manual mode;
: travel setting;
5.4 Travel Setting (VERY IMPORTANT)
In the first installation of gate openers, the installer need to set open and closed limit switch positions for running the travel.
5.4.1 Learn the journey in the distress limit mode
Open both sides of the gate and lock the clutch, and then press and hold the “+” button on the control board until the digital screen shows “SU”. After this step, the gate will firstly run towards the closing direction and stop, and then the gate will automatically open. When the two swing gates are fully open, the gates will automatically close for the second time, and the travel setting will be completed when the gates are closed. If the distance of starting slow speed of gate is not appropriate, adjust the “SLOW DOWN ” button to revise the distance.
Note:

  • Wiring: the black wire of main engine 1 is connected to the left side of MOTOR1;
    The brown cable of host 1 connects to the right side of MOTOR1.The black cable of main engine 2 connects to the left side of MOTOR2; The brown cable of main engine 2 connects to the right side of MOTOR2.

  • In single-door mode,the host connects to MOTOR1.

  • If the gate suddenly stops during travel setting, please increase the resistance force.

  • If the gate didn’t stop when meets the obstacles during travel setting, please appropriately reduce the resistance force.

  • Installer must redo travel setting after modifying the “SPEED” trimmer.

5.5 Trimmers Setting
Obstacle Sensibility Trimmer
To adjust the sensitivity of obstacle — clockwise to increase, counterclockwise to reduce the sensitivity of obstacle. If there are environmental effects, such as heavy winds, adjust the trimmer according to environment.
Slow Speed Distance Trimmer
To adjust slow speed distance — clockwise to increase, counterclockwise to decrease slow speed distance. Please do not set very short slow speed distance, to avoid the gate collision.
Gate Moving Speed Trimmer
To adjust gate moving speed — clockwise to accelerate, counterclockwise to slow down. The trimmer can be adjusted to change the opening and closing travel time. This adjustment must be finished before travel setting.

GATEXPERT SW400DC Swing Gate Opener - Speed Trimmer

5.6 Learning Remote Control & Delete Remote Control
5.6.1 Learning Remote Control
Press and hold “-” button, the alarm light will keep flashing, and digital screen displays remote control mode — “PO” — two swing gates single channel mode; “Pd” — single gate four channel mode; Press the button of the remote control to be learned, the digital screen will show the number of current learned remote control, then the remote control learning is completed. (The default of new paired remote control is two swing gates single channel mode).
5.6.2 Delete Remote Control
Enter into “AE” in the digital screen and then to choose “rE” to delete the remote controls.

GATEXPERT SW400DC Swing Gate Opener - Remote Control

5.6.3 Special Remote Control Key-button
Press and hold the combination keys for 5S.
C(stop)+D(single gate) combination key — enter into remote control learning.
5.7 Control Board Settings
5.7.1 Base Menu
Press “PROG” to enter into base menu;
Digital screen shows “NE”, select other functions of this menu by “+” and “-” buttons.
Press “SET” to confirm or to enter into sub-menu.
To exit menu, press “PROG”.
If no command for one minute, the menu will automatically exit.
Base Menu

GATEXPERT SW400DC Swing Gate Opener - Base Menu 1GATEXPERT SW400DC Swing Gate Opener - Base Menu
2GATEXPERT SW400DC Swing Gate Opener - Base Menu
3

5.7.2 Base Menu Instruction

Menu
Press “PROG” to enter into base menu.| Option
Press “+”(up) or “-”(down) to select;
Press “SET” to confirm.| Default/Attention
---|---|---
Working Mode| Standard mode; O/C/S (Open/Close/Stop).
O/S/C standard mode with automatic closing function. When the gate opens, it will automatically close after automatic closing time. If a “close the gate” command is sent during the automatic closing time waiting time, the automatic closing function will be canceled.
Community mode(with automatic closing function). When the gate opens, any gate command will not be responded until it closes automatically. If user sends gate command during the closing process, then the gate will reopen. If a gate command is sent during the automatic closing waiting time, this waiting time will be recalculated. If the gate is not closed completely for more than ten consecutive times, the automatic closing function will be canceled and the gate will be closed by re-sending the gate closing command. Note that in community mode, the gate still has the automatic closing function in case of meeting obstacles.
External three keys (open/close/stop)
External three keys o/p/s (Automatic closing with)| Standard mode; O/C/S (Open/Close/Stop).
Single Gate/Dual Gates Switch| Dual gates mode(default).
Single gate mode.| Dual gates mode.
Open Gate Time Interval| 00-10: Open gate time interval is 0-10 seconds(default 3 seconds). If the interval shorter than 2 seconds, then the electric lock cannot be used.| 3 seconds.
Automatic Closing Time| Automatic closing time can be set as 15(default), 30, 60, 90 seconds.| 15 seconds.
Remote Control Mode| Dual gates single channel mode.
Four channel mode.
Single gate single channel mode.
Delete all paired remote controls| Dual gates single channel mode.
Low consumption mode| Low consumption mode on (When there is no operation in the initial screen, the control board will automatically enter the low- consumption mode after 1 minute.)
Low consumption mode off| Low consumption mode on

5.7.3 Advanced Menu
Long press “PROG” 2 seconds to enter into advanced menu.
Digital Screen shows “TL”, press “+”(up) or “-”(down) to select;
Short press “SET” to confirm or to enter into sub-menu.
Short press “PROG” to exit.
If no command for one minute, the menu will automatically exit.
Advanced Menu

GATEXPERT SW400DC Swing Gate Opener - Advanced MenuGATEXPERT SW400DC Swing Gate Opener - Advanced Menu
2GATEXPERT SW400DC Swing Gate Opener -
Advanced Menu 3

5.7.4 Advanced Menu Instruction

Menu
Long press “PROG” 2 seconds to enter into base menu.| Option
Press “+”(up) or “-”(down) to select;
Press “SET” to confirm.| Default/Attention
---|---|---
Travel time adjustment| Time of of gate1
Time of of gate2
Time fine tuning of of gate 1
Time fine tuning of of gate 2| After automatic learning, if the stroke is not ideal, it can be
adjusted manually. The shorter the time under the resistance limit, the farther the deceleration distance of the
door. And in the Hall limit, the shorter the time, the shorter the door travel.
Photo Sensor| N/C; photo sensor normally is on.(Default)
N/O; photo sensor normally off.| N/O; photo sensor normally on.
Electric Lock| Electric lock normally is on. (Default)
Electric lock normally is off.| Electric lock normally on.
Reverse push lock| Reverse push lock mode off
Reverse push lock mode on
(When the electric lock is started, M1 will run for a distance in the direction of the door to prevent the electric lock from getting stuck and unable to be opened.)| Reverse push lock mode off
Alarm Lamp| Alarm lamp normally is on. 24V power supply. (Default)
Alarm lamp normally flashes. 24V power supply.| Alarm lamp normally is on. 24V power supply.
Limit Switch Mode| Stop block.(Default)
Hall sensor.| Stop block.
Gate Opener Secection| SW400DC.
SW300DC. (Default)
SW200DC.
PK300DC| SW200DC.
Direction of the door| Gate Opens Inwards (Default)
Gate Opens Outwards| Gate Opens Inwards
Buzzer| The buzzer is off
The buzzer is on (When the mains is running normally, the buzzer buzzes short and long. When the battery is in normal use, the buzzer buzzes for 6S and then stops. When the battery power is low, the buzzer stops after 3 seconds. When the control board runs incorrectly, the buzzer buzzes fast and long.)| The buzzer is on
Factory Default Setting| Cancel factory default setting.
Factory default setting completes.|

Others

6.1 Maintenance
Check whether the gate operates normally every month.
For the sake of safety, each gate is suggested to be equipped with infrared protector, and regular inspection is required as well.
Before installation and operation of the gate opener, please read all instructions carefully.
We reserve the right to change the instruction without prior notice.
6.2 Error Message
Errors that may occur when the door is operating properly

Wrong Indication Cause of Error Solution
Door 1 Obstructed in opening 1. Check whether there are obstacles when

opening door 1
2. Adjust resistance sensitivity appropriately
3. Increase deceleration distance appropriately
| Door 2 Obstructed in opening| 1. Check whether there are obstacles when opening door 2
2. Adjust resistance sensitivity appropriately
3. Increase deceleration distance appropriately
| Door 2 is closing with difficulty| 1. Check whether there are obstacles when door 1 is closed
2. Adjust resistance sensitivity appropriately
3. Increase deceleration distance appropriately
| Door 2 is closing with difficulty| 1. Check whether there are obstacles when door 2 is closed
2. Adjust resistance sensitivity appropriately
3. Increase deceleration distance appropriately
| Infrared disconnect| 1. Check the infrared setting status
2. Whether there are occlusions in the infrared
| Door 1 closes before door 2| 1. Relearn your itinerary
2.Adjust the opening time interval
| The motor works for too long| 1. Check whether you have completed the itinerary
2.Hall component damage
| No study itinerary| Re-complete the trip

6.3 Troubleshooting

Problems Possible Reasons Solutions
The gate cannot open or close normally, and Display does not light. 1.The

power is off.
2.Fuse is burned.
3.Control board power wiring with problem.| 1.Switch on the power supply.
2.Check the fuse, change the fuse if burnt.
3.Re wiring according to instructions.
The gate can open but cannot close.| 1.Photocell wiring with problem.
2.Photocell mounting with problem.
3.Photocell is blocked by objects.
4.Sensitivity of obstacle is too high.| 1.If not connect photocell, please make sure that the 5 and 6, 5 and 7 short circuit; if connect infrared sensor, please make sure the wiring is correct and the photocell is N.C.
2.Make sure that the photocell mounting position can be mutually
aligned.
3.Remove the obstacle.
4.Reduce the sensitivity of obstacle.
Remote control doesn’t work.| 1.Battery level of the remote control is low.
2.Remote control learning is not completed.| 1.Change the remote control battery.
2.Re-conduct remote control learning.
Press OPEN, CLOSE button, the gate is not moving, motor has noise.| Gate moving is not smoothly.| According to the actual situation to adjust the motor or the gate.
Leakage switch tripped.| Power supply line short circuit or motor line short circuit.| Check wiring.
Remote control working distance is too short.| Signal is blocked.| Connect external receiver antenna, 1.5 meters above ground.
The gate moves to the middle position to stop or reverse.| 1.Motor output force is not enough.
2.Sensitivity of obstacle is too high.
3.Gate meets obstacle.| 1.Check whether the transformer power is normal, if not, change the
transformer.
2.Adjust the TR2.
3.Remove the obstacle.

PK400DC-A0(SW400DC)
www.gatexpertstore.com

Documents / Resources

| GATEXPERT SW400DC Swing Gate Opener [pdf] User Manual
SW400DC Swing Gate Opener, SW400DC, Swing Gate Opener, Gate Opener
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals