Specifications

  • Model: SL500DCL/SL800DCL
  • Warranty Period: 1 year
  • Power Source: Electric
  • Default Opening Direction: Right-hand side

Product Usage Instructions

Before Installation Testing

1. Test the gate opener by plugging it into a power source and
pressing the remote.

2. Press the opening button to rotate the output gear, then
press the stop button to stop rotation.

3. Press the closing button to rotate the output gear in the
opposite direction.

Installation Steps

1. Ensure the gate opener is unplugged before starting
installation.

2. Remove the motor cover to mount the motor to the mounting
plate or concrete footing.

3. If gate needs to open from the left, mount the opener on the
left-hand side.

4. Any modifications or works on the opener should be done with
power off and unplugged.

Safety Instructions

1. Keep fingers away from the motor output gear while it’s
turning.

2. Always work on the gate opener with power off and
unplugged.

Parts List

No. Name Quantity
1 Motor 1

FAQ

Q: Can I make changes to the settings of the gate opener

myself?

A: No, any changes to the settings must be done by a licensed
electrician.

Q: What should I do if my gate needs to open from the

left?

A: If your gate needs to open from the left, you need to mount
the opener on the left-hand side as shown in Figure 3 of the
manual.

Q: How long is the warranty period for this product?

A: The warranty period is 1 year from the date of invoice, and
covers repair or replacement for product defects.

“`

Sliding Gate Opener User Manual
SL500DCL/SL800DCL
Website: www.gatexpertstore.com E-mail: sales@gatexpertstore.com

WARNING
Instructions must be read before installation. Please follow these instructions carefully, incorrect installation could affect gate operation.
When mounting and positioning this product please ensure the power cable is unplugged.
The motor cover will need to be removed to mount the motor to the mounting plate or directly to the concrete footing.
Any changes to the settings on this product can only be made by a licensed electrician.
www.gatexpertstore.com

WARRANTY
1. To repair against this warranty card and invoice during the warranty period. 2. Warranty period: 1 year after the date of invoice. 3. Without unauthorized dismantling, any product broken or damage due to quality problem, we’ll offer the repair service for free or replace for free. 4. The malfunction and damages caused by incorrect use or man fault is not covered by this warranty.

CONTACT US
E-mail: sales@gatexpertstore.com
Please fill in the order information in the form below. All personal information you provided will be only used for warranty service and kept
strictly confidential. Refer to this list when contacting GATEXPERT for technical service or assistance with
your automatic gate opener.

Order Number Product Model

Purchase Date

Country / Region

Email Address Issue Details

www.gatexpertstore.com

CONTENTS
Default Setting Instruction………………………………………………………………………………………………..1 Safety Instruction……………………………………………………………………………………………………………..2 Parts List………………………………………………………………………………………………………………………….3 Technical Parameters……………………………………………………………………………………………………….5 Installation……………………………………………………………………………………………………………………….5
Before You Start…………………………………………………………………………………………………………..5 Tools Required / Example Sliding Gate………………………………………………………………………….6 Step 1 – Gate Preparation………………………………………………………………………………………………6 Step 2 – Checking Manual Release…………………………………………………………………………………7 Step 3 – Removing / Installing Motor Cover………………………………………………………………………7 Step 4 ­ Motor Pad Footing……………………………………………………………………………………………8 Step 5 – Fitting Mounting Base and Motor…………………………………………………………………………8 Step 6 – Sprocket and Chain & Motor Alignment……………………………………………………………….9 Step 7 – Limit Switch Stop……………………………………………………………………………………………10 Step 8 – Powering on………………………………………………………………………………………………….12 Step 9 – Testing Travel and Limit Stops………………………………………………………………………….13 Programming and Wiring………………………………………………………………………………………………..14 Terminal Instructions…………………………………………………………………………………………………..15 Wiring to the Terminal…………………………………………………………………………………………………15 Connecting Infrared Photocells…………………………………………………………………………………….17 Operation Interface Instruction……………………………………………………………………………………..18 Manual Control Mode………………………………………………………………………………………………….19 Quick Setting for Running Travel…………………………………………………………………………………..20 Remote Control Management………………………………………………………………………………………21
Single Button Mode Learning(L1)…………………………………………………………………………..22 Three-Button Mode Learning(L2)…………………………………………………………………………..23 Pedestrian Mode on Remote Control(L3)………………………………………………………………..24 Remote Control Delete(L4)……………………………………………………………………………………25 Remote Control Quick Learning……………………………………………………………………………..26 Basic Menu Setting…………………………………………………………………………………………………….27 Running Speed Setting(L1)……………………………………………………………………………………28 Slow Stop Speed Setting(L2)…………………………………………………………………………………29 Reverse When Meeting Obstacles Setting (L3)………………………………………………………..30 Slow Stop Distance Setting (L4)…………………………………………………………………………….31 Auto-close Function Setting (L5)…………………………………………………………………………….32 Advanced Menu Setting………………………………………………………………………………………………34
www.gatexpertstore.com

Working Mode Setting (L1)…………………………………………………………………………………….34 Acceleration Setting (L2)……………………………………………………………………………………….36 Start-up Delay Setting (L3)…………………………………………………………………………………….37 Opening Direction Setting (L4)……………………………………………………………………………….38 Alarm Lamp Setting(L5)………………………………………………………………………………………..39 Other Menu Setting…………………………………………………………………………………………………….40 Emergency Stop Distance Setting(L1)…………………………………………………………………….41 Buzzer Setting(L2)……………………………………………………………………………………………….42 Battery Level Checking……………………………………………………………………………………………….44 Restore Factory Setting………………………………………………………………………………………………45 Control Board Error Instruction……………………………………………………………………………………..46 Maintenance…………………………………………………………………………………………………………………..46 Troubleshooting……………………………………………………………………………………………………………..47 Drawing and Measurements…………………………………………………………………………………………….48
www.gatexpertstore.com

Default Setting Instruction
The gate opener will open the gate to the right-hand side as its default setting. By default, the opener mounts on the right-hand side. (Figure 1)

Gate in closed position

Gate in open position

Figure 1

Before installation: Test the gate opener by plugging it into a power source and pressing the

remote. Press the opening button, the output gear rotates, then press the stop button, the output

gear stops rotating. Finally, press the closing button, the output gear rotates to the opposite

direction. This will give you an understanding of the way in which the opener will move the gate.

Press the first/top button on the remote.

Rotating output gear will drive the gate frame.

Then the gate will move in the set direction.

Figure 2
Note: Ensure that the gate opener is unplugged before proceeding with installation. Please keep fingers away from the motor output gear whilst it is turning.

If your gate needs to open from the other direction (to the left, refer to figure 3), your opener needs to be mounted on the left-hand side as shown.

Figure 3

Any works done to the gate opener must be completed whilst the power is off, and the opener is unplugged.

1

www.gatexpertstore.com

Safety Instruction
Warning: Incorrect or improper use of this product can cause damage to persons, animals or properties. · Please ensure that the input voltage used matches with the supply voltage of gate opener. · All modifications to wiring or electrics, and any adjustment or maintenance to input voltage
must be done by a qualified electrician. · All potential hazards and exposed pinch points of the gate must be eliminated or guarded prior
to installation of this gate opener. · Never mount any device that operates the gate opener where the user can reach over (under,
around or through) the gate to operate the controls. These must be placed away from any moving range of the moving gate. · Ensure power plug is disconnected from the power socket during installation or maintenance. · Keep remote control and other control devices out of children’s reach, in order to avoid unintentional activation. · To ensure safety, before installing the motor, mount a Gate End Catch and a Gate Stop at each end of the rail to prevent the gate travelling off the track. · If required, install infrared photocell to detect obstructions and prevent injury to person or damage to property. · Instruct all users about the control systems provided and the manual opening operation in case of emergency. · Ensure that the power cable is connected to a RCD protected weatherproof power outlet installed by a qualified electrician. · Do not install this product in an explosive atmosphere or where there is any danger of flooding. · This product was exclusively designed and manufactured for the use specified in the present documentation. Any other use not specified in this documentation could damage the product and be dangerous. · Only use original parts for any maintenance or repair operation. Our company declines all responsibility with respect to the automation safety and correct operation when other supplier’s components are used. · Do not modify the automation components, unless explicitly authorized by our company. · The user must avoid any attempt to carry out any works or repairs on this product, and should always request the assistance of qualified personnel. · This product is suitable for use on one sliding gate only. · Anything which is not expressly provided for in these instructions is not allowed and will void warranty. · Dispose of all packing materials (plastic, cardboard, polystyrene etc.) according to current guidelines. Keep plastic bags and polystyrene out of children’s reach. · Save these instructions for future use.

2

www.gatexpertstore.com

Parts List

Parts List (standard configuration)

No.

Picture

1

Name Motor

Quantity 1

2

Manual Release Keys

2

3

Remote Controls

2

4

Accessories Box

1

4-1

Sprocket Cover

1

4-2

Chain(Including 2 Chain Links)

6m

4-3

Tie Rod

2

4-4

Square Screw

4

4-5

Round Screw

4

4-6

Door Connecting Plate

2

4-7

Horizontal Mounting Plate

1

4-8

Vertical Mounting Plate

2

3

www.gatexpertstore.com

No.

Picture

4-9

4-10

4-11 4-12 4-13 4-14 4-15

Parts List (optional)

No.

Picture

1

2

3

Name Anchor Bolts M8

Quantity 4

Limit Switch Stop Bracket

2

Magnetic Limit Switch Stop

2

Hexagon Head Bolt M6X65

4

Nut M8

4

Flat Washer 8

2

Spring Washers 8

2

Inner Hexagon Head Bolt M6X20

4

Hexagon Head Bolt M8X40

4

Nut M6

16

Nut M8

16

Flat Washer 6

16

Flat Washer 8

16

Spring Washers 6

16

Spring Washers 8

12

Note: Extra flat washers and spring washers are spare parts.

Name Infrared Photocell Wireless Keypad
Alarm Lamp

Quantity 1 1 1

4

www.gatexpertstore.com

Additional remote controls: Spare/Additional remotes for the automatic gate kit, these will need to be paired to the motor. Infrared photocell: Detects pedestrians, vehicles and objects that cross an infrared beam and prevents the gate from closing. Wireless keypad: Allows secure access through the gate used with a user set code. Wired control: Allow users to control the opening and closing of the gate through an external push-button. Alarm lamp: Alerts people near the gate and users that the gate is in operation.

Technical Parameters
Model Power Supply Motor Power Gate Moving Speed Maximum Loading Weight Remote Control Distance Remote Control Mode Limit Switch Working Noise Working Duty Recording of up Remote Controls Remote Frequency Working Temperature Package Weight Battery Specification
Installation

SL500DCL

SL800DCL

110VAC/60Hz; 220VAC/50Hz

150W

170W

16-18m/min

500KG

800KG

30m

Single button mode / Three button mode

Magnetic limit switch

60dB

S2, 20min

32

433.92 MHz

-20°C – +70°C

16.2KG

17.2KG

12V/9Ah*1pc

Before You Start
· SL500DCL/SL800DCL Sliding Gate Automation Kit is suitable for powering the opening and closing motion of gates up to 500, 800kg in weight, up to a length of 12m. (Standard kit contains a 6m chain, if the gate length is over 5.5m, please consider to extend the length of the chain.)
· Gate motion is achieved by the rotating output gear of the gate opener driving the gear rack (sold separately) fitted to the moving gate.
· The gate opener requires you to press the remote control once to open, and once again to close. This is a safety feature to ensure safe operation.
· The opener must be fitted within private property, never externally to a property’s boundary.

Any works done to the gate opener must be completed whilst the power is off and the opener is unplugged. Any modifications/alterations/works to AC power components must only be completed by
a licensed electrician

5

www.gatexpertstore.com

Tools Required
· Tape measure · Level · 12mm concrete drill and hammer (when uses expansion screws) · Phillips head screwdriver · Straight screwdriver
Example Sliding Gate

Gate Track and Track Wheels Gate End Catch

Gate Guide Rollers

Gate Stop

Figure 4
Please ensure that the gate opener power cable is not plugged in at any stage before Step 8.
Step 1 – Gate Preparation
· Ensure that the sliding gate is correctly installed. · The gate is horizontal and level and the gate can glide back and forth smoothly when moved by
hand before installing the gate opener. · Wheels and guide rollers should rotate easily and be free from dirt or grime. · Track should be flat, level and firmly affixed. · Any misalignment in the gate will affect performance of the automatic gate opener.

The gate should slide smoothly by hand before attempting to install the gate opener. Figure 5

6

www.gatexpertstore.com

Step 2 – Checking Manual Release
· Insert the key and open the manual release bar to enable the motor get into manual mode and check that the motor output gear rotates freely by hand (Figure 6).
Turn 90°

To make the motor into manual mode, insert the key and open the manual release bar till it rotates by 90°.
Figure 6

In manual mode, the gear can turn freely and the gate can be operated by hand.

Step 3 – Removing / Installing Motor Cover
· Unscrew the two cover screws located at each side of the motor cover.

Figure 7
· Sprocket cover installation as Figure 8 Bolts
Sprocket Cover
Figure 8 7

www.gatexpertstore.com

Step 4 – Motor Pad Footing
· The motor pad concrete footing requires an area of no less than 500mm long x 350mm wide and a minimum depth of 200mm (Standard requirement).
· Ensure surface is level and parallel to the driveway.

Mounting Plate Dimensions
Figure 9
Step 5 – Fitting Mounting Base and Motor
· Fit anchor bolts(included in kit) or expansion bolts(should be prepared by users) according to holes in mounting base (as per Figure 9).
· Position the mounting base and fix it as per Figure 10. · Bolt motor to its base using the M8x40 bolts with spring and flat washers provided and tighten
as required.

Figure 10 8

www.gatexpertstore.com

Nut
Spring Washer
Flat Washer
Flat Washer Nut
Figure 11
Fitting Motor · Fit motor and mounting base on the concrete footing. · Ensure the motor output sprocket and chain are correctly aligned. Sprocket and chain should
be centered as much as possible. · Take the motor away from mounting base. · Leave a space of 30cm from the motor to end of the chain.
Sliding Gate Frame (in open position)
Use pencil, chalk or similar tools to mark at the corners of mounting plate
Figure 12
Step 6 – Sprocket and Chain & Motor Alignment
· Ensure output sprocket and chain are correctly aligned. Under no circumstances should the gate opener output sprocket carry any weight of the gate. It is the task of the gate castors or wheels to carry the weight of the gate.
· If the gate doesn’t slide freely by hand, adjust the height of the chain accordingly until the full length of gate slides freely by hand.
· Ensure the chain is in proper tightness after installation. (refer to Figure 14)

9

www.gatexpertstore.com

Sprocket

Chain

Figure 13

Figure 14

Step 7 – Limit Switch Stop
Included in your gate opener kit are two limit switch stops which must be fitted on your gate to ensure safe operation.
The limit switch stops are designed to set the desired opening and closing position of your gate. When the limit switch stops come into contact with the magnetic limit switch, the gate will stop moving.
It is extremely dangerous that without or incorrect installation of the limit switch stops can cause crash of gate, damage of internal structure of the motor, moreover, the gate may slide off the guide rail.
Setting the Limit Switch Stops
Closed Position · Position gate 150-200mm back from the gate end catch closed position. This will help in
making sure you do not slam the gate into the end stop/catch when setting the closed position under power. · Fit limit switch stop onto the top of chain at the point where it meets the magnetic limit switch on the motor. · Tighten locking screws of limit switch stop.

10

www.gatexpertstore.com

Magnetic limit switch
switch
Open Position · Position gate 150-200mm back from the gate stop open position. This will help in making sure
you do not slam the gate into the end stop/catch when setting the open position under power. · Fit limit switch stop onto the top of chain at the point where it meets the magnetic limit switch on
the motor. · Tighten locking screws of limit switch stop.

Magnetic limit switch
switch
Test the magnetic limit switch stops by moving the gate manually until you hear a click, making sure contact is made with the magnetic limit switch on the motor.

Black magnet (N) Blue magnet (S)

Open Position Limit Switch Stop

Closed Position Limit Switch Stop

Figure 15

11

www.gatexpertstore.com

Motor Magnet Gate
Installation drawing of limit switch stop
Figure 16
To Reset: Turning the power off will reset the limit switch stop memory. Power on the gate opener again, pressing remote control or external push button switch to open and then close the gate once, then new limit switch stop setting is completed.
Step 8 – Powering on
· Ensure that the outer cover has been fitted and fastened back onto the motor base. · Before powering up the gate opener make sure the gate can travel by hand in manual mode
(key unlocked). · Slide the gate to between the middle of the posts, approximately (see below diagrams). · Lock the manual release spanner (key locked) in readiness for automatic mode. · Plug the power cord into an approved RCD protected weatherproof outlet. · Remote controls included in this kit are factory paired ready for use.

Figure 17 12

www.gatexpertstore.com

Step 9 – Testing Travel and Limit Stops
Testing the Closed Position · Ensure gate opener is installed as per step 5, 6 and 7 and the sliding gate is in the middle
position. · Press remote (remotes included in kit are factory paired to the motor). The sliding gate will
begin to close. · The limit switch stop will hit the limit switch and the sliding gate will stop. · When the gate stops, measure the distance remaining between the sliding gate and the desired
closed position. · You have now determined the closed position of the sliding gate when the limit switch stop hits
the limit switch. · Adjust the limit switch stop from the measurement you have taken to get your final gate closed
position. The ideal closed final position for the gate frame is 10-15mm from closed gate end catch.
Testing the Open Position · Press remote, the sliding gate will begin to open. · The limit switch stop will hit the limit switch and the sliding gate will stop. · When the gate stops, measure the distance remaining between the sliding gate and the desired
open position. · You have now determined the open position of the sliding gate when the limit switch stop hits
the limit switch · Adjust the limit switch stops from the measurement you have taken to get your final gate open
position. The ideal open final position for the gate frame is 10-15mm from the gate stop.
To Reset: When setting new limit stop positions please ensure that you turn the power off and then on again. Turning the power off will reset the limit stop memory, allowing for new limit switch stop positions to be recognized by the motor.

Figure 18
Now the basic open and closed positions are set, for further setting functions and adjusting parameters, please refer to pages 14-46 in this manual.

13

www.gatexpertstore.com

Programming and Wiring
Any works to the 110V/220V AC must only be performed by a licensed electrician. Ensure power is off before any modifications are made.

Indicator Light

Set Button

X7 Terminal

X6 Terminal X4 Terminal

X5 Terminal Hall Line

X2 Terminal

Motor Terminal

JP3 Terminal Figure 20

14

www.gatexpertstore.com

Terminal Instructions
All changes to these settings below must be completed by licensed electrician.
X7 Terminal: (as per Figure 20):
ANT: Extra Antenna GND: Extra Antenna Shield COM: Common Terminal for External Push Button STP: External Stop Push Button Switch PED: External Close Push Button Switch OSC: External Open Push Button Switch
X5 Terminal:
IR: Photocell Input Common Terminal for Photocell(N.C.) GND: Ground 12V: Additional Accessories +12VDC, after gate closed in place, the board will enter into low power consumption mode, this terminal will cut off the 12V power supply. LAMP+: Alarm Lamp +12/24VDC LAMP-: Alarm Lamp -12/24VDC
Wiring to the Terminal

Using a screwdriver to loosen the screw on the side of the terminal.

Insert the wire into the number on the terminal that you are looking to connect to. Refer to Page 14.

Tighten with a screwdriver to secure the wire in place.

15

www.gatexpertstore.com

JP3 Terminal:
Turn on the buzzer when the jumper cap is inserted into the ON end, and turn off the buzzer when the jumper cap is inserted into the OFF end.
Note:When the buzzer needs to be turned on, it is necessary to operate the control board to enter the “Other Menu” mode, turn on the buzzer function, and then plug the jumper cap into the ON end. At this time, the buzzer function can be used normally.
X6 Terminal:
SIG: Output close signal after gate closed in place. OPLM: Open Limit Switch COM: Limit Switch Common Terminal. CLLM: Close Limit Switch
X4 Terminal:
24VBAT+: Battery Positive 24VBAT-: Battery Negative Battery Specification: 24V/9Ah
12VBAT+: Battery Positive 12VBAT-: Battery Negative Battery Specification: 12V/9Ah Note: + and – must be wired correctly, wrong wring will damage the control board.
X2 Terminal:
Power: Power Supply(Transformer Output) Transformer Specification: 240VAC/22VAC or 120VAC/22VAC Rated Power: 120W

16

www.gatexpertstore.com

Connecting Infrared Photocells
The below steps must be completed by licensed electrician.
Highly recommend the use of infrared photocells as an additional safety feature.
While closing, if the ray of the Infrared Photocell is blocked, the gate will stop and open immediately, to protect user and property security. To install photocells, connect wiring as per Figure 21. You must remove the wire jumper between terminal IR and terminal GND on X5 (ref to Figure 22). The distance between photocell receiver and photocell transmitter should not be less than 2 meters; otherwise, the induction effect of photocell may be affected.

Photocell Receiver

Photocell Transmitter

Figure 21

17

www.gatexpertstore.com

Before Installing Photocells

Power off, then loosen IR and GND ports on X5 Terminal with a screwdriver.
Figure 22
Operation Interface Instruction

Remove the short circuit wire between ports IR & GND on X5 Terminal.

Figure 23
Indicator Lights:
L0 (Green): Indicating the control board working status and menu status. L1-L5 (Red): Indicating the settings, parameters, errors and battery level.
Set Buttons:
PROG: Enter into or exit the setting menu. – and +: Function select and parameter adjust. SET: Choose the selection, confirm the setting. Note: Press the setting button for a short while (within 1 sec.) or long press the button (over 2 sec.) will be for different functions.

18

www.gatexpertstore.com

Manual Control Mode
In order to make sure that the first installation of this product is in good condition, users can test the opening/closing running under manual control mode. If there are any abnormalities, please exit the manual control mode and re-adjust the gate, gate opener and the limit switch. A. Operation Instruction: 1. Press and hold “SET” button for 3 sec. Indicator light L3 will flicker. 2. Press “+” button to open the gate, then release “+” to stop running; Press “-” to close the
gate, then release it to stop running. 3. Press “PROG” button once to exit the manual control mode. Indicator light L3 will be
off. B. Operation Graphic Illustration

SET
Press “SET” for 3 sec.

L3 flicker

Press and hold “+” to open, release “+” to stop running. Press and hold “-” to close, release “+” to stop running.

PROG
Press “PROG” once

L3 off

Exit

Note: 1. If there is no operation under the limit switch position setting for 60 sec., system will
automatically exit the setting. 2. If need to exit during setting, press “PROG” once to directly exit. 3. Under manual control mode, if the gate didn’t stop when it arrived at limit switch, please

19

www.gatexpertstore.com

exit the manual control mode, and check if the two magnet limit switch stops are within the detection range of the magnetic limit switch.
Quick Setting for Running Travel
Precondition: 1. Before setting the running travel, please make sure that the gate is completely open. 2. Please install the limit switch stops at limit switch position and make sure the polarities
are correct, after installed, please do not move or remove it anymore. A. Operation Instruction a. Press “+” button for 2 sec., motor will automatically start it’s travel learning. b. During gate closing, the indicator lights will be on from L5 to L1 in sequence and repeatedly. c. During gate opening, the indicator lights will be on from L1 to L5 in sequence and repeatedly. d. After travel is set, the indicator lights L1-L5 will be on in sequence, then all will flicker once and off. B. Operation Graphic Illustration 1. Enter into Quick Setting:

Press “+” for 2 sec.
2. After Travel is Set:

During closing, L5 to L1 will be During opening, L1 to L5 will be on in sequence and repeatedly on in sequence and repeatedly

20

www.gatexpertstore.com

L1 to L5 will be on in sequence L1-L5 will flicker once then off

Save and exit

Note: 1. If there is no operation under the limit switch position setting for 60 sec., system will
automatically exit the setting. 2. If need to exit during setting, press “PROG” once to exit.
Remote Control Management
Operation Instruction: 1. Press “-” button for 2 sec. under standby mode to enter into the first function of remote
control management. 2. Different functions can be selected through “+” and “-” buttons. 3. Press “SET” button to enter into the corresponding parameter settings.
Standby Mode

Press “-” button for 2 sec.

L1 L2 L3 L4 L5

L1 L2 L3 L4 L5

L1 L2 L3 L4 L5

Single Button Mode Learning

Three-Button Mode Learning

Pedestrian Mode on Remote Control

Remote Control Management

L1 L2 L3 L4 L5
Remote Control Delete

Figure 24

21

www.gatexpertstore.com

Remote Control Mode Instruction: There are two modes available for remote control under this control board. Users may pair the remote control in their required mode.

1. Single button mode: Open/Stop/Close of the gate opener is controlled by only one button on the remote control.
2. Three button mode: Open/Stop/Close of the gate opener is controlled by three different

buttons on the remote control.

Single Button Mode Learning (L1)

Under this mode, one of the remote control buttons which is paired to the gate opener can

individually control the operation of one opener. The rest buttons on this remote control can

be used to pair to other openers. Gate 1

Gate 2

Gate 3

Gate 4

Figure 25
A. Operation Instruction 1. Press and hold “-” button for 2 sec. to enter into remote control management mode.
Indicator light L1 will be steady on. 2. Press “SET” button once to enter into single button learning mode. All indicator lights
will flicker repeatedly from L1 to L5. (If an alarm lamp is connected, it’ll blink as well). 3. Press the button which is to be paired on the remote control twice. The indicator lights
L1-L5 will be on in sequence, then all will flicker once and off. (If an alarm lamp is connected, it’ll be on for one sec.). Learning is complete thereafter.

22

www.gatexpertstore.com

B. Operation Graphic Illustration

Press “-” for 2 sec. L1 will be steady on

SET
Press “SET” once

L1-L5 will flicker repeatedly

Press the button to be paired twice

L1-L5 will be on in sequence, then flicker once and off

Save and exit

Three-button Mode Learning (L2)

Under this mode, all buttons on the remote control which are paired to the gate opener will be separately used for gate openingclosing and stop. (Please refer to Figure 26 for the

usage for the forth button on the remote control) Open

Close

Stop

Pedestrian Mode

Figure 26
23

www.gatexpertstore.com

A. Operation Instruction 1. Press and hold “-” button for 2 sec. to enter into remote control management mode.
Indicator light L1 will be steady on. 2. Press “+” button once to select three button learning mode option. Indicator light L2
will be steady on. 3. Press “SET” button once to enter into three button learning mode. All indicator lights
will flicker repeatedly from L1 to L5. (If an alarm lamp is connected, it’ll blink as well) 4. Press the button which is to be paired on the remote control twice. The indicator lights
L1-L5 will be on in sequence, then all will flicker once and off. (If an alarm lamp is connected, it’ll be on for one sec.) Learning is complete thereafter. B. Operation Graphic Illustration

Press “-” for 2 sec. L1 will be steady on

Press “+” once L2 will be steady on

Press “SET” once

L1-L5 will flicker repeatedly

Press the button to be paired twice

L1-L5 will be on in sequence

then flicker once and off

Save and exit

Note: If there is no operation under the remote control learning status for 20 sec., system

will automatically exit the setting and save all the paired remote controls.

Pedestrian Mode on Remote Control (L3)
Pedestrian mode function: when gate is closed, press the Pedestrian button on the remote

24

www.gatexpertstore.com

control, the gate will open 1m wide to allow pedestrian access. A. Operation Instruction: 1. Press and hold “-” button for 3 sec. to enter into remote control management mode.
Indicator light L1 will be steady on. 2. Press “+” button twice to select pedestrian mode function. Indicator light L3 will be
steady on. 3. Press “SET” button once to enter into pedestrian mode setting. All indicator will
flicker repeatedly from L1 to L5. 4. Press the button which is to be paired on the remote control once. The indicator
lights L1-L5 will be on in sequence, then all will flicker once and off.. Learning is complete thereafter. B. Operation Graphic Illustration:

Press “-” for 3 sec. L1 will be steady on

Press “+” twice

L3 will be steady on

SET
Press “SET” once

L1-L5 will flicker repeatedly

Press the button to be paired twice

L1-L5 will be on in sequence, all together flicker once

Save and exit

Remote Control Delete (L4)
This operation will delete all the remote controls that are paired to this control board. A. Operation Instruction: 1. Press and hold “-” button for 2 sec. to enter into remote control management mode.

25

www.gatexpertstore.com

Indicator light L1 will be on. 2. Press “+” button three times to select remote control delete option. Indicator light L4
will be on. 3. Press “SET” button once to enter into remote control delete option. Indicator lights
L1-L5 will be steady on. 4. Press and hold “SET” button for 2 sec. will delete all remotes and it will automatically
exit. Indicator lights will be off in sequence from L5 to L1, after which indicator lights L1-L5 will be on for one sec. B. Operation Graphic Illustration:

Press “-” for 2 sec. L1 will be steady on Press “+” 3 times

L4 will be steady on

SET
Press “SET” once

L1-L5 will be steady on

SET
Press “SET” for 2
sec.

L1-L5 will be on in sequence, all together flicker once

Remotes delete and exit

Remote Control Quick Learning
Remote control quick learning function enables user to pair the remote controls without opening the motor cover. Precondition: 1. To have one remote control that has already been paired.

26

www.gatexpertstore.com

2. To ensure the reliability of learning, please operate the quick learning function within 2 meters from the gate opener.
3. Please make sure that the gate opener is equipped with an alarm lamp, which will help you to check the status of remote control learning.
A. Operation Instruction: 1. Simultaneously press and hold the third and the fourth buttons of the paired remote control for 6 sec. The alarm lamp will flash, which indicates that the learning function of the control board is on working. 2. Press the button to be learned on the remote control under the above status. The alarm lamp will be off. Then remote control learning is complete. 3. The system will automatically exit the learning mode after pairing finished.
Note: The remote control working mode will be copied from original one to new paired one. B. Operation Graphic Illustration:

Press these 2 buttons Alarm lamp flash
together for 6 sec.

Press the button to be paired twice

Alarm lamp off

Save and exit

Basic Menu Setting
Operation Instruction: 1. Under standby mode, press and hold “PROG” button for 3 sec., the indicator light L0 will flicker once and enter into basic menu setting. 2. Press “+” or “-” button to select the different function settings. 3. Press “SET” button to enter into the selected function setting.

27

www.gatexpertstore.com

Standby Mode

PPrreessss aannddhohlodl”d +”P”RbOutGto”n ffoorr 33sseec.c.

L1 L2 L3 L4 L5

L1 L2 L3 L4 L5

Running Speed Setting

Slow Stop Speed Setting

L1 L2 L3 L4 L5

L1 L2 L3 L4 L5

Auto-reverse When Meeting AObstacles Setting

Slow Stop Distance Setting

Basic Menu Setting

Figure 27

L1 L2 L3 L4 L5 Auto-close Function Setting

Running Speed Setting (L1)
Users can adjust the gate opening and closing speed according to the actual installation and using condition. A. Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “SET” button once to enter into running speed setting. Indicator lights L1-L5
will show the current running speed. (The default is L5) 3. Press “+” or “-” button to adjust the running speed. Indicator lights L1-L5 will indicate
different speed status. The more the indicator lights are on, the faster the running speed will be. 4. Press “SET” button to save and system will automatically exit. The indicator lights L1-L5 will be on in sequence, then all will flicker once and off. B. Operation Graphic Illustration

28

www.gatexpertstore.com

PROG
Press “PROG” for 3
sec.

L0 flicker once, L1 will be steady on

SET
Press “SET” once

Press “+” or “-” to set, LED will show the setting value

SET
Press “SET” once

L1-L5 will be on in sequence then all flicker once and off.

Save and exit

Slow Stop Speed Setting (L2)

The setting for slow stop speed can effectively reduce the inertial force when the gate is open or closed to its limit position, which will extend the lifetime of both gate and gate opener. A. Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “+” button to select slow stop speed setting. Indicator light L2 will be steady on. 3. Press “SET” button once to enter into setting mode. Indicator lights L1-L5 will show
the current slow stop speed. (The default is L2) 4. Press “+” or “-” button to adjust the slow stop speed. Indicator lights L1-L5 will show
the different speed status. The more the indicator lights are on, the faster the slow stop speed will be. 5. Press “SET” button to save and system will automatically exit. The indicator lights L1-L5 will be on in sequence, then all will flicker once and off. B. Operation Graphic Illustration

29

www.gatexpertstore.com

PROG
Press “PROG” for
3 sec.

L0 flicker once, L1 will be steady on

Press “+” once

L2 will be steady on

SET
Press “SET” once

Press “+” or “-” to set, LED will show the setting value

SET
Press “SET” once

L1-L5 will be on in sequence then all flicker once and off.

Reverse When Meeting Obstacles Setting (L3)

Save and exit

During the gate opening or closing, accidental collision with obstacles may pose a threat to people and property. In order to prevent impact of such collision, users may adjust the sensitivity of meeting obstacles to reduce the impact damage. A. Operation Instruction: 1. Press “PROG” button for 3 sec. to enter into basic menu. Indicator light L0 will flicker
once, then L1 will be steady on. 2. Press “+” button twice to select the reverse option. Indicator light L3 will be steady
on. 3. Press “SET” button once to enter into setting mode. Indicator lights L1-L5 will show
the current setting. (The default is L3) 4. Press “+” or “-” button to set the sensitivity of meeting obstacles. Indicator lights
L1-L5 will show the different sensitivity of meeting obstacles. The less the indicator lights are on, the more the sensitivity will be. L1-L5 are all off means to cancel the Auto-reverse function.

30

www.gatexpertstore.com

5. Press “SET” button once to save the setting and system will automatically exit. The indicator lights L1-L5 will be on in sequence, then all will flicker once and off.
B. Operation Graphic Illustration

PROG
Press “PROG” for 3 sec.

L0 flicker once, L1 will be steady on

Press “+” twice

SET
L3 will be steady on Press “SET” once

Press “+” or “-” to set, LED will show the setting value

SET
Press “SET” once

L1-L5 will be on in sequence then all flicker once and off.

Save and exit

Note: The default setting of this function is suitable for gate weighting 500kg and the glide rail for running the gate is smooth, if this function is not workable or reverse frequently, please adjust the settings to reduce or increase a little bit.

Slow Stop Distance Setting (L4)

Setting a slow stop distance enables the gate to run more smoothly, which will extend the service life of gate and gate opener. A. Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “+” button three times to select slow stop distance option. Indicator light L4 will
be steady on. 3. Press “SET” button once to enter into slow stop distance setting. Indicator lights
L1-L5 will show the current distance of slow stop. (The default is L3) 4. Press “+” or “-” button to set the slow stop distance. Indicator lights L1-L5 will show

31

www.gatexpertstore.com

the different slow stop distance. The more the indicator lights are on, the longer the distance will be. If the gate is heavy(over 800kg), it is recommended to set it on L4 or L5 to have a better slow stop running. If the gate weight is less than 500kg, it is recommended to set it on L2 or L1 to have a better slow stop running. 5. Press “SET” button once to save and system will automatically exit. The indicator lights L1-L5 will be on in sequence, then all will flicker once and off. B. Operation Graphic Illustration

PROG
Press “PROG” for 3 sec.

L0 flicker once, L1 will be steady on

Press “+” 3 times

SET
L4 will be steady on Press “SET” once

Press “+” or “-” to set, LED will show the setting value

SET
Press “SET” once

L1-L5 will be on in sequence then all flicker once and off.

Save and exit

Auto-close Function Setting (L5)

When the gate is completely open, the control board will send the auto-close signal to enable the gate to close automatically according to the pre-set auto-close time. A. Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “+” button four times to enter into Auto-close option. Indicator light L5 will be
steady on. 3. Press “SET” button once to enter into setting. Indicator lights L1-L5 will show the
current auto-close time. (The default is all indicator lights off)

32

www.gatexpertstore.com

4. Press “+” or “-” button to set the auto-close time. The number of steady on indicator lights will indicate the Auto-close time. (Table 1 Auto-Close Time)
5. Press “SET” button once to save and system will automatically exit. The indicator lights L1-L5 will be on in sequence, then all will flicker once and off.
B. Operation Graphic Illustration

PROG
Press “PROG” for 3 sec.

L0 flicker once, L1 will be steady on

SET
Press “+” 4 times L5 will be steady on Press “SET” once

Press “+” or “-” to set, LED will show the setting value

SET
Press “SET” once

L1-L5 will be on in sequence then all flicker once and off.

Save and exit

Indicator light status Off On Flicker

L1

L2

L3

L4

L5

L1

L2

L3

L4

L5

L1

L2

L3

L4

L5

L1

L2

L3

L4

L5

L1

L2

L3

L4

L5

L1

L2

L3

L4

L5

Status Instruction Cancel Auto-close function Auto-close after 10 sec. Auto- close after 20 sec. Auto-close after 30 sec. Auto-close after 40 sec. Auto- close after 50 sec.

Table 1 Auto-Close Time

33

www.gatexpertstore.com

Advanced Menu Setting
1. Press “PROG” button for 3 Sec. under the standby mode, indicator light L0 will flicker once to enter into basic menu setting. Press “PROG” button again for 3 sec. indicator light L0 will flicker twice to enter into the advanced menu setting.
2. Different functions can be selected through “+” and “-” buttons. 3. Press “SET” button to enter into the selected function settings
Standby Mode
Press “PROG” button for 3 sec., indicator light L0 will flicker once
Basic Menu Setting
Press “PROG” button again for 3 sec., indicator light L0 will flicker twice

Working Mode Setting

Acceleration Setting

Start-up Delay Setting Opening Direction Setting Alarm Lamp Setting

Advanced Menu Setting
Figure 28

Working Mode Setting (L1)

Due to the usage for this product is different for users from different regions, the control board for this product offers 3 different working modes for users to choose. 1. Standard Mode (L1): Terminals for external buttons: OSC: Single button control PED: Pedestrian button STP: Stop button 2. Three Button Mode (L2): Terminals for external buttons: OSC: Opening button PED: Closing button STP: Stop button 3. Community Mode (L3): Terminals for external buttons:

34

www.gatexpertstore.com

OSC: Single button control PED: Pedestrian button STP: Stop button Special function: Only the gate is completely open, can it be closed thereafter. If the gate is not completely open, then only opening and stop can be operated in order to prevent any interruption which will trigger closing during the opening travel operated by the first user. A. Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “PROG” button again for 3 sec. to enter into advanced menu. Indicator light L0
will flicker twice, then L1 will be steady on. 3. Press “SET” button once to enter into working mode setting. Indicator lights L1-L3
will show the current selection. (The default is L1) 4. Press “+” or “-” button to select the working mode. Indicator lights L1-L3 will show the
current selection. 5. Press” SET” button once to save and system will automatically exit. The indicator
lights L1-L5 will be on in sequence, then all will flicker once and off. B. Operation Graphic Illustration

PROG
Press “PROG” for 3 sec.

L0 flicker once, L1 will be steady on

PROG
Press “PROG” again for 3 sec.

L0 flicker twice, L1 will be steady on

SET
Press “SET” once

Press “+” or “-” to set, LED will show the setting value

SET
Press “SET” once

L1-L5 will be on in sequence then all flicker once and off.

Save and exit

35

www.gatexpertstore.com

Acceleration Setting (L2)
Due to the different installation environment and gate installation status, users can adjust the acceleration of starting and deceleration of buffering of the gate opener to their necessary. A. Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “PROG” button again for 3 sec. to enter into advanced menu. Indicator light L0
will flicker twice, then L1 will be steady on. 3. Press “+” button once to select acceleration option. Indicator light L2 will be steady
on. 4. Press “SET” button once to enter into acceleration setting. Indicator lights L1-L5 will
show the current acceleration value. (The default is L2) 5. Press “+” or “-” button to set the acceleration value. Indicator lights L1-L5 will indicate
the different acceleration values. The more the indicator lights will be on, the faster the speed changes. 6. Press” SET” button once to save and system will automatically exit. The indicator lights L1-L5 will be on in sequence, then all will flicker once and off. B. Operation Graphic Illustration

36

www.gatexpertstore.com

PROG
Press “PROG”
for 3 sec.

L0 flicker once, L1 will be steady on

PROG
Press “PROG” L0 flicker twice, L1 again for 3 sec. will be steady on

Press “+” once

L2 will be steady on

SET
Press “SET” once

Press “+” or “-” to set, LED

SET

L1-L5 will be on in sequence then all

will show the setting value Press “SET” once flicker once and off.

Save and exit

Start-up Delay Setting (L3)
The control board of this product is with low power consumption function under standby mode. When the gate opener stopped working, the control board will automatically enter into low power consumption mode to reduce the power consumption and extend the using time of the battery. Meanwhile, in order to reduce the power consumption of external accessories under standby mode, the control board will turn off the power for infrared sensor after entering into standby mode. When the gate opener is about to operate, it’ll supply the power for accessories. In order to ensure the reliability of the infrared sensor, it is requested that the control board performs delay detection to the input signal of infrared sensor. When the gate opener receives the opening/closing signal, it’ll start to work after a certain time (the settled delay time) A. Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “PROG” button again for 3 sec. to enter into advanced menu. L0 will flicker

37

www.gatexpertstore.com

twice, then L1 will be steady on. 3. Press “+” button twice to select start-up delay setting. Indicator light L3 will be steady
on. 4. Press “SET” button once to enter into start-up delay setting. Indicator lights L1-L3 will
show the current setting. (The default is L1) 5. Press “+” or “-” button to set the start-up delay time. Indicator lights L1-L3 will show
the current setting. (Table 2 Start-up Delay Time) 6. Press “SET” button once to save and system will automatically exit. The indicator
lights L1-L5 will be on in sequence, then all will flicker once and off. B. Operation Graphic Illustration

PROG
Press “PROG”
for 3 sec.

L0 flicker once, L1 will be steady on

PROG
Press “PROG”
again for 3 sec.

L0 flicker twice, L1 will be steady on Press “+” twice

L3 will be steady on

SET
Press “SET” once

Press “+” or “-” to set, LED

SET

L1-L5 will be on in

will show the setting value

sequence then all Press “SET” once flicker once and off.

Save and exit

38

www.gatexpertstore.com

Indicator light status Off On Flicker

L1

L2

L3

L4

L5

L1

L2

L3

L4

L5

L1

L2

L3

L4

L5

L1

L2

L3

L4

L5

Status Instruction Cancel start-up delay function Delay for 0.5 sec Delay for 1 sec Delay for 1.5 sec

Table 2 Start-up Delay Time
Opening Direction Setting (L4)
This setting is for users to change the gate opening direction without exchanging the motor wires, but have to note the limit stop position. A. Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “PROG” button again for 3 sec. to enter into advanced menu. L0 will flicker
twice, then L1 will be steady on. 3. Press “+” button three times to select opening direction option. Indicator light L4 will
be steady on. 4. Press “SET” button once to enter into opening direction setting. Indicator light L1 will
indicate the current setting. (Default is L1 on) 5. Press “+” or “-” button to set the opening direction. Indicator light L1 on or off stands
for the 2 directions. (L1 on: open to right-hand; L1 off: open to left-hand) Press “SET” button once to save and system will automatically exit. The indicator lights L1-L5 will be on in sequence, then all will flicker once and off.

39

www.gatexpertstore.com

B. Operation Graphic Illustration

PROG
Press “PROG” for L0 flicker once, L1

3 sec.

will be steady on

PROG
Press “PROG” again for 3 sec.

L0 flicker twice, L1 will be steady on

Press “+” for 3 times

L4 will be steady on

SET
Press “SET” once

Press “+” or “-” to set, LED will show the setting value

SET

L1-L5 will be on in

Press “SET” once sequence then all flicker once and off.

Save and exit

Note: After changing the opening direction, L1 and L2 will flicker together, it’s a notice that reminding you to re-set the running travel for the gate. Before re-setting, it’s extremely important to enter into manual control mode to confirm the polarities of the limit switch stops are correct and well contacted to the magnetic limit switch.
Alarm Lamp Setting(L5)
This setting is to select the working mode of alarm lamp (blinker or steady on) A. Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “PROG” button again for 3 sec. to enter into advanced menu. L0 will flicker
twice, then L1 will be steady on. 3. Press “+” button four times to select alarm lamp working mode option. Indicator light
L5 will be steady on. 4. Press “SET” button once to enter into alarm lamp working mode setting. Indicator

40

www.gatexpertstore.com

light L1 will show the current setting. 5. Press “+” or “-” button to set the alarm lamp working mode. Indicator light L1 on or off
will indicate the alarm lamp working mode. (L1 off: blinker; L1 on: steady on) 6. Press “SET” button once to save and system will automatically exit. The indicator
lights L1-L5 will be on in sequence, then all will flicker once and off. B. Operation Graphic Illustration

PROG
Press “PROG” for
3 sec.

L0 flicker once, L1 will be steady on

PROG
Press “PROG”
again for 3 sec.

L0 flicker twice, L1 will be steady on

Press “+” for 4 L5 will be steady on times

SET
Press “SET” once

Press “+” or “-” to set, LED will show the setting value

SET

L1-L5 will be on in

sequence then all Press “SET” once
flicker once and off.

Save and exit

Other Menu Setting
1. Press “PROG” button for 3 Sec. under the standby mode, indicator light L0 will flicker once to enter into basic menu setting. Press “PROG” button again for 3 sec. indicator light L0 will flicker twice to enter into the advanced menu setting. Then press “PROG” button for 3 sec., the indicator light L0 will flicker three times then enter into other menu setting.
2. Different functions can be selected through “+” and “-” buttons. 3. Press “SET” button to enter into the selected function settings.

41

www.gatexpertstore.com

Basic Menu

Press “PROG” for 3 sec., L0 will flicker once

Advanced Menu Press “PROG” again for 3 sec., L0 will flicker twice
Other Menu Press “PROG” for 3 sec. for the third time, L0 will flicker three times

Emergency Stop Distance

Buzzer Setting

Setting

Other Menu Setting

Figure 29

Emergency Stop Distance Setting(L1)
This setting is to change the distance of emergency stop during gate running. A longer distance will reduce the damage to the gate brings by impact force of emergency stop. Users can set the distance to their required. A. Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “PROG” button again for 3 sec. to enter into advanced menu. L0 will flicker
twice, then L1 will be steady on. 3. Press “PROG” button for 3 sec. for the third time to enter into other menu setting. L0
will flicker three times, then L1 will be steady on. 4. Press “SET” button once to enter into emergency stop distance setting. Indicator
light L1 to L5 will show the current setting value. (Default is L2)

42

www.gatexpertstore.com

5. Press “+” or “-” button to set the emergency stop distance. Indicator lights L1-L5 will indicate different distance, the more the indicator lights are on, the longer the distance will be, the better the buffering will be before gate stopped.
6. Press “SET” button once to save and system will automatically exit. The indicator lights L1-L5 will be on in sequence, then all will flicker once and off.
B. Operation Graphic Illustration

PROG
Press “PROG” for L0 flicker once, L1

3 sec.

will be steady on

PROG
Press “PROG”
again for 3 sec.

L0 flicker twice, L1

PROG
Press “PROG” for

will be steady on 3 sec.

L0 flicker 3 times, L1 will be steady on

SET
Press “SET” once

Press “+” or “-” to set, LED

SET

L1-L5 will be on in

sequence then all

will show the setting value Press “SET” once

flicker once and off.

Save and exit

Note: 1. This function can directly affect the infrared emergency stop effect. Non
professionals should not adjust it. 2. Only when the emergency stop distance is set to the minimum (only L0 lights up),
the door opener will immediately stop and retreat to the closed position after triggering infrared when closing the door. But the impact force generated during an emergency stop will reduce the lifespan of the door opener.
3. When the emergency stop distance increases (excluding “minimum emergency stop distance”), the door opener will slowly slide for a certain distance before stopping and

43

www.gatexpertstore.com

retreating to the closing position after triggering infrared when closing the door. This setting can effectively reduce the damage caused to the door opener during emergency stop, but the emergency stop triggered by infrared is no longer sensitive when closing the door. Please adjust it as needed to be careful not to cause personal injury and property damage due to improper setting.
Buzzer Setting(L2)
This setting is to enable or disable the buzzer, users can set to their required. There are four types of buzzer this motor will make for different conditions:
1. Motor works normally under mains power: the buzzer sounds short but long lasting.
2. Motor works normally under battery power: the buzzer sounds strident but long lasting, and will stop after 6 sec.
3. Motor works abnormal due to low battery power: the buzzer sounds strident but long lasting, and will stop after 3 sec.
4. Motor works abnormal due to control board error: the buzzer sounds strident but long lasting.
A. Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “PROG” button again for 3 sec. to enter into advanced menu. L0 will flicker
twice, then L1 will be steady on. 3. Press “PROG” button for 3 sec. for the third time to enter into other menu setting. L0
will flicker three times, then L1 will be steady on. 4. Press “+” button twice to select buzzer setting option. Indicator light L2 will be steady
on. 5. Press “SET” button once to enter into buzzer setting. Indicator light L1 on or off will

44

www.gatexpertstore.com

indicate the current setting value. (Default is L1 off) 6. Press “+” or “-” button to enable or disable the buzzer. Indicator light L1 off: enable;
on: disable. 7. Press “SET” button once to save and system will automatically exit. The indicator
lights L1-L5 will be on in sequence, then all will flicker once and off. B. Operation Graphic Illustration

PROG
Press “PROG” for L0 flicker once, L1

3 sec.

will be steady on

PROG
Press “PROG” again for 3 sec.

PROG
L0 flicker twice, L1 Press “PROG” for
will be steady on 3 sec.

L0 flicker three times, L1 will be steady on

SET
Press “SET” once

Press “+” or “-” to set, LED will show the setting value

SET

L1-L5 will be on in

sequence then all Press “SET” once
flicker once and off.

Save and exit

Note: The buzzer cannot be disabled under battery powered.
After turning on the buzzer function, when the motor is running normally and the buzzer is still not working, please check whether the “JP3 terminal” is inserted at the ON end.

Battery Level Checking
The current battery level can be checked through the indicator lights. When the battery power is low (battery voltage 11.3V), the gate opener will stop running to protect the battery being damaged. Under such circumstance, users may have to unlock the gate

45

www.gatexpertstore.com

opener first, then move the gate by hand. A. Operation Instruction: 1. Press “SET” button once. Indicator lights L1-L5 will indicate the current battery level
(Table 3 Battery Level) 2. Press “PROG” button once to exit the battery level checking. Indicator lights L1-L5
will be off.
B. Operation Graphic Illustration

SET

L1-L5 will indicate the

PROG

Press “SET” once current battery level Press “PROG” once

L1-L5 off

Exit

Indicator Light Status Off

L1

L2

L3

L1

L2

L3

L1

L2

L3

L1

L2

L3

L1

L2

L3

L1

L2

L3

On Flicker

L4

L5

L4

L5

L4

L5

L4

L5

L4

L5

L4

L5

Status Instruction Battery Level 12.6V Battery Level 12.3V Battery Level 12.0V Battery Level 11.7V Battery Level 11.3V Battery Level 11.3V

Table 3 Battery Level
Restore Factory Setting
1. Simultaneously press the three buttons “SET””+” and “-” for 3 sec. The indicator lights L1-L5 will be on in sequence, then all will flicker once and off. Save and exit.

46

www.gatexpertstore.com

SET
Press “SET” “+” and
“-” together for 3 sec.

L1-L5 will be on in all flicker once and off sequence

Save and exit

Control Board Error Instruction

The indicator light will display the error during gate running:

Indicator Light Status Off

Flicker

Status Instruction

L1

L2

L3

L4

L5

L1

L2

L3

L4

L5

Meeting obstacles during gate opening Meeting obstacles during gate closing

L1

L2

L3

L4

L5

L1

L2

L3

L4

L5

Running time over 60S Infrared photocell disconnecting

L1

L2

L3

L4

L5

No hall sensor

L1

L2

L3

L4

L5

No travel

Table 4 Error Instruction
Maintenance
The gate should be checked every month to make sure it operates normally. For the sake of safety, each gate is suggested to be equipped with infrared protector, and regular inspection is required. Before installation and operation of the gate opener, please read all instructions carefully. Our company keep the right to change the instruction without prior notice.

47

www.gatexpertstore.com

Troubleshooting
Any troubleshooting work below done to the motor must be completed by a licensed electrician and only whilst the power is off and the motor is unplugged!

Problem The gate cannot open or close normally, indicator light doesn’t on.
The gate can only open, can’t close.
Remote control doesn’t work. Press OPEN, CLOSE button, the gate is not moving, motor has noise.
Arrived at open or closed limit switch, but motor didn’t stop.
Leakage switch tripped.

Possible Reason 1. The power supply is disconnected. 2. Fuse is blown. 3. Control board X2 terminal wrongly wired.
1. Photocell wrongly wired. 2. Photocell wrongly installed. 3. Photocell is blocked by objects. 4. Sensitivity of meeting obstacle is too high.
1. Battery level is too low. 2. Remote control not paired. 1. Gate moving is not smoothly. 2. Hall sensor damaged.
1. Magnetic limit switch damaged. 2. Polarities of the two limit switch stops are opposite. 3. Hall sensor part damaged. Power supply wires short circuit or motor wires short circuit.

Solution 1. Connect the power supply. 2. Check the fuse (FU) and replace
if blown. 3. Re-wiring according to this user
manual. 1. If not connect photocell, please ensure the infrared terminal and GND terminal has a jumper wire; if connect photocell, please ensure the wiring is correct and the photocell type is N.C. 2. Ensure that the photocell mounting position can be mutually aligned. 3. Remove the obstacle. 4. Reduce the sensitivity of obstacle. 1. Change the battery. 2. Pair the remote control to the gate opener. 1. Adjust the motor or gate according to the actual situation. 2. Replace the hall sensor.
1. Change the magnetic limit switch. 2. Switch over the two limit switch stops. 3. Change the hall sensor part.
Check wiring.

Drawing and Measurements