GATEXPERT SL500DCL Sliding Automatic Gate Operator Kit User Manual
- May 15, 2024
- GATEXPERT
Table of Contents
- SL500DCL Sliding Automatic Gate Operator Kit
- Specifications
- Product Usage Instructions
- Before Installation Testing
- Installation Steps
- Safety Instructions
- Parts List
- Q: Can I make changes to the settings of the gate opener
- Q: What should I do if my gate needs to open from the
- Q: How long is the warranty period for this product?
SL500DCL Sliding Automatic Gate Operator Kit
“`html
Specifications
- Model: SL500DCL/SL800DCL
- Warranty Period: 1 year
- Power Source: Electric
- Default Opening Direction: Right-hand side
Product Usage Instructions
Before Installation Testing
1. Test the gate opener by plugging it into a power source and
pressing the remote.
2. Press the opening button to rotate the output gear, then
press the stop button to stop rotation.
3. Press the closing button to rotate the output gear in the
opposite direction.
Installation Steps
1. Ensure the gate opener is unplugged before starting
installation.
2. Remove the motor cover to mount the motor to the mounting
plate or concrete footing.
3. If gate needs to open from the left, mount the opener on the
left-hand side.
4. Any modifications or works on the opener should be done with
power off and unplugged.
Safety Instructions
1. Keep fingers away from the motor output gear while it’s
turning.
2. Always work on the gate opener with power off and
unplugged.
Parts List
No. | Name | Quantity |
---|---|---|
1 | Motor | 1 |
FAQ
Q: Can I make changes to the settings of the gate opener
myself?
A: No, any changes to the settings must be done by a licensed
electrician.
Q: What should I do if my gate needs to open from the
left?
A: If your gate needs to open from the left, you need to mount
the opener on the left-hand side as shown in Figure 3 of the
manual.
Q: How long is the warranty period for this product?
A: The warranty period is 1 year from the date of invoice, and
covers repair or replacement for product defects.
“`
Sliding Gate Opener User Manual
SL500DCL/SL800DCL
Website: www.gatexpertstore.com E-mail: sales@gatexpertstore.com
WARNING
Instructions must be read before installation. Please follow these
instructions carefully, incorrect installation could affect gate operation.
When mounting and positioning this product please ensure the power cable is
unplugged.
The motor cover will need to be removed to mount the motor to the mounting
plate or directly to the concrete footing.
Any changes to the settings on this product can only be made by a licensed
electrician.
www.gatexpertstore.com
WARRANTY
1. To repair against this warranty card and invoice during the warranty
period. 2. Warranty period: 1 year after the date of invoice. 3. Without
unauthorized dismantling, any product broken or damage due to quality problem,
we’ll offer the repair service for free or replace for free. 4. The
malfunction and damages caused by incorrect use or man fault is not covered by
this warranty.
CONTACT US
E-mail: sales@gatexpertstore.com
Please fill in the order information in the form below. All personal
information you provided will be only used for warranty service and kept
strictly confidential. Refer to this list when contacting GATEXPERT for
technical service or assistance with
your automatic gate opener.
Order Number Product Model
Purchase Date
Country / Region
Email Address Issue Details
www.gatexpertstore.com
CONTENTS
Default Setting Instruction………………………………………………………………………………………………..1 Safety
Instruction……………………………………………………………………………………………………………..2 Parts
List………………………………………………………………………………………………………………………….3 Technical
Parameters……………………………………………………………………………………………………….5
Installation……………………………………………………………………………………………………………………….5
Before You Start…………………………………………………………………………………………………………..5 Tools Required /
Example Sliding Gate………………………………………………………………………….6 Step 1 – Gate
Preparation………………………………………………………………………………………………6 Step 2 – Checking Manual
Release…………………………………………………………………………………7 Step 3 – Removing / Installing Motor
Cover………………………………………………………………………7 Step 4 Motor Pad
Footing……………………………………………………………………………………………8 Step 5 – Fitting Mounting Base and
Motor…………………………………………………………………………8 Step 6 – Sprocket and Chain & Motor
Alignment……………………………………………………………….9 Step 7 – Limit Switch
Stop……………………………………………………………………………………………10 Step 8 – Powering
on………………………………………………………………………………………………….12 Step 9 – Testing Travel and Limit
Stops………………………………………………………………………….13 Programming and
Wiring………………………………………………………………………………………………..14 Terminal
Instructions…………………………………………………………………………………………………..15 Wiring to the
Terminal…………………………………………………………………………………………………15 Connecting Infrared
Photocells…………………………………………………………………………………….17 Operation Interface
Instruction……………………………………………………………………………………..18 Manual Control
Mode………………………………………………………………………………………………….19 Quick Setting for Running
Travel…………………………………………………………………………………..20 Remote Control
Management………………………………………………………………………………………21
Single Button Mode Learning(L1)…………………………………………………………………………..22 Three-Button
Mode Learning(L2)…………………………………………………………………………..23 Pedestrian Mode on Remote
Control(L3)………………………………………………………………..24 Remote Control
Delete(L4)……………………………………………………………………………………25 Remote Control Quick
Learning……………………………………………………………………………..26 Basic Menu
Setting…………………………………………………………………………………………………….27 Running Speed
Setting(L1)……………………………………………………………………………………28 Slow Stop Speed
Setting(L2)…………………………………………………………………………………29 Reverse When Meeting Obstacles
Setting (L3)………………………………………………………..30 Slow Stop Distance Setting
(L4)…………………………………………………………………………….31 Auto-close Function Setting
(L5)…………………………………………………………………………….32 Advanced Menu
Setting………………………………………………………………………………………………34
www.gatexpertstore.com
Working Mode Setting (L1)…………………………………………………………………………………….34 Acceleration
Setting (L2)……………………………………………………………………………………….36 Start-up Delay Setting
(L3)…………………………………………………………………………………….37 Opening Direction Setting
(L4)……………………………………………………………………………….38 Alarm Lamp
Setting(L5)………………………………………………………………………………………..39 Other Menu
Setting…………………………………………………………………………………………………….40 Emergency Stop Distance
Setting(L1)…………………………………………………………………….41 Buzzer
Setting(L2)……………………………………………………………………………………………….42 Battery Level
Checking……………………………………………………………………………………………….44 Restore Factory
Setting………………………………………………………………………………………………45 Control Board Error
Instruction……………………………………………………………………………………..46
Maintenance…………………………………………………………………………………………………………………..46
Troubleshooting……………………………………………………………………………………………………………..47 Drawing and
Measurements…………………………………………………………………………………………….48
www.gatexpertstore.com
Default Setting Instruction
The gate opener will open the gate to the right-hand side as its default
setting. By default, the opener mounts on the right-hand side. (Figure 1)
Gate in closed position
Gate in open position
Figure 1
Before installation: Test the gate opener by plugging it into a power source and pressing the
remote. Press the opening button, the output gear rotates, then press the stop button, the output
gear stops rotating. Finally, press the closing button, the output gear rotates to the opposite
direction. This will give you an understanding of the way in which the opener will move the gate.
Press the first/top button on the remote.
Rotating output gear will drive the gate frame.
Then the gate will move in the set direction.
Figure 2
Note: Ensure that the gate opener is unplugged before proceeding with
installation. Please keep fingers away from the motor output gear whilst it is
turning.
If your gate needs to open from the other direction (to the left, refer to figure 3), your opener needs to be mounted on the left-hand side as shown.
Figure 3
Any works done to the gate opener must be completed whilst the power is off, and the opener is unplugged.
1
www.gatexpertstore.com
Safety Instruction
Warning: Incorrect or improper use of this product can cause damage to
persons, animals or properties. · Please ensure that the input voltage used
matches with the supply voltage of gate opener. · All modifications to wiring
or electrics, and any adjustment or maintenance to input voltage
must be done by a qualified electrician. · All potential hazards and exposed
pinch points of the gate must be eliminated or guarded prior
to installation of this gate opener. · Never mount any device that operates
the gate opener where the user can reach over (under,
around or through) the gate to operate the controls. These must be placed away
from any moving range of the moving gate. · Ensure power plug is disconnected
from the power socket during installation or maintenance. · Keep remote
control and other control devices out of children’s reach, in order to avoid
unintentional activation. · To ensure safety, before installing the motor,
mount a Gate End Catch and a Gate Stop at each end of the rail to prevent the
gate travelling off the track. · If required, install infrared photocell to
detect obstructions and prevent injury to person or damage to property. ·
Instruct all users about the control systems provided and the manual opening
operation in case of emergency. · Ensure that the power cable is connected to
a RCD protected weatherproof power outlet installed by a qualified
electrician. · Do not install this product in an explosive atmosphere or where
there is any danger of flooding. · This product was exclusively designed and
manufactured for the use specified in the present documentation. Any other use
not specified in this documentation could damage the product and be dangerous.
· Only use original parts for any maintenance or repair operation. Our company
declines all responsibility with respect to the automation safety and correct
operation when other supplier’s components are used. · Do not modify the
automation components, unless explicitly authorized by our company. · The user
must avoid any attempt to carry out any works or repairs on this product, and
should always request the assistance of qualified personnel. · This product is
suitable for use on one sliding gate only. · Anything which is not expressly
provided for in these instructions is not allowed and will void warranty. ·
Dispose of all packing materials (plastic, cardboard, polystyrene etc.)
according to current guidelines. Keep plastic bags and polystyrene out of
children’s reach. · Save these instructions for future use.
2
www.gatexpertstore.com
Parts List
Parts List (standard configuration)
No.
Picture
1
Name Motor
Quantity 1
2
Manual Release Keys
2
3
Remote Controls
2
4
Accessories Box
1
4-1
Sprocket Cover
1
4-2
Chain(Including 2 Chain Links)
6m
4-3
Tie Rod
2
4-4
Square Screw
4
4-5
Round Screw
4
4-6
Door Connecting Plate
2
4-7
Horizontal Mounting Plate
1
4-8
Vertical Mounting Plate
2
3
www.gatexpertstore.com
No.
Picture
4-9
4-10
4-11 4-12 4-13 4-14 4-15
Parts List (optional)
No.
Picture
1
2
3
Name Anchor Bolts M8
Quantity 4
Limit Switch Stop Bracket
2
Magnetic Limit Switch Stop
2
Hexagon Head Bolt M6X65
4
Nut M8
4
Flat Washer 8
2
Spring Washers 8
2
Inner Hexagon Head Bolt M6X20
4
Hexagon Head Bolt M8X40
4
Nut M6
16
Nut M8
16
Flat Washer 6
16
Flat Washer 8
16
Spring Washers 6
16
Spring Washers 8
12
Note: Extra flat washers and spring washers are spare parts.
Name Infrared Photocell Wireless Keypad
Alarm Lamp
Quantity 1 1 1
4
www.gatexpertstore.com
Additional remote controls: Spare/Additional remotes for the automatic gate kit, these will need to be paired to the motor. Infrared photocell: Detects pedestrians, vehicles and objects that cross an infrared beam and prevents the gate from closing. Wireless keypad: Allows secure access through the gate used with a user set code. Wired control: Allow users to control the opening and closing of the gate through an external push-button. Alarm lamp: Alerts people near the gate and users that the gate is in operation.
Technical Parameters
Model Power Supply Motor Power Gate Moving Speed Maximum Loading Weight Remote
Control Distance Remote Control Mode Limit Switch Working Noise Working Duty
Recording of up Remote Controls Remote Frequency Working Temperature Package
Weight Battery Specification
Installation
SL500DCL
SL800DCL
110VAC/60Hz; 220VAC/50Hz
150W
170W
16-18m/min
500KG
800KG
30m
Single button mode / Three button mode
Magnetic limit switch
60dB
S2, 20min
32
433.92 MHz
-20°C – +70°C
16.2KG
17.2KG
12V/9Ah*1pc
Before You Start
· SL500DCL/SL800DCL Sliding Gate Automation Kit is suitable for powering the
opening and closing motion of gates up to 500, 800kg in weight, up to a length
of 12m. (Standard kit contains a 6m chain, if the gate length is over 5.5m,
please consider to extend the length of the chain.)
· Gate motion is achieved by the rotating output gear of the gate opener
driving the gear rack (sold separately) fitted to the moving gate.
· The gate opener requires you to press the remote control once to open, and
once again to close. This is a safety feature to ensure safe operation.
· The opener must be fitted within private property, never externally to a
property’s boundary.
Any works done to the gate opener must be completed whilst the power is off
and the opener is unplugged. Any modifications/alterations/works to AC power
components must only be completed by
a licensed electrician
5
www.gatexpertstore.com
Tools Required
· Tape measure · Level · 12mm concrete drill and hammer (when uses expansion
screws) · Phillips head screwdriver · Straight screwdriver
Example Sliding Gate
Gate Track and Track Wheels Gate End Catch
Gate Guide Rollers
Gate Stop
Figure 4
Please ensure that the gate opener power cable is not plugged in at any stage
before Step 8.
Step 1 – Gate Preparation
· Ensure that the sliding gate is correctly installed. · The gate is
horizontal and level and the gate can glide back and forth smoothly when moved
by
hand before installing the gate opener. · Wheels and guide rollers should
rotate easily and be free from dirt or grime. · Track should be flat, level
and firmly affixed. · Any misalignment in the gate will affect performance of
the automatic gate opener.
The gate should slide smoothly by hand before attempting to install the gate opener. Figure 5
6
www.gatexpertstore.com
Step 2 – Checking Manual Release
· Insert the key and open the manual release bar to enable the motor get into
manual mode and check that the motor output gear rotates freely by hand
(Figure 6).
Turn 90°
To make the motor into manual mode, insert the key and open the manual release
bar till it rotates by 90°.
Figure 6
In manual mode, the gear can turn freely and the gate can be operated by hand.
Step 3 – Removing / Installing Motor Cover
· Unscrew the two cover screws located at each side of the motor cover.
Figure 7
· Sprocket cover installation as Figure 8 Bolts
Sprocket Cover
Figure 8 7
www.gatexpertstore.com
Step 4 – Motor Pad Footing
· The motor pad concrete footing requires an area of no less than 500mm long x
350mm wide and a minimum depth of 200mm (Standard requirement).
· Ensure surface is level and parallel to the driveway.
Mounting Plate Dimensions
Figure 9
Step 5 – Fitting Mounting Base and Motor
· Fit anchor bolts(included in kit) or expansion bolts(should be prepared by
users) according to holes in mounting base (as per Figure 9).
· Position the mounting base and fix it as per Figure 10. · Bolt motor to its
base using the M8x40 bolts with spring and flat washers provided and tighten
as required.
Figure 10 8
www.gatexpertstore.com
Nut
Spring Washer
Flat Washer
Flat Washer Nut
Figure 11
Fitting Motor · Fit motor and mounting base on the concrete footing. · Ensure
the motor output sprocket and chain are correctly aligned. Sprocket and chain
should
be centered as much as possible. · Take the motor away from mounting base. ·
Leave a space of 30cm from the motor to end of the chain.
Sliding Gate Frame (in open position)
Use pencil, chalk or similar tools to mark at the corners of mounting plate
Figure 12
Step 6 – Sprocket and Chain & Motor Alignment
· Ensure output sprocket and chain are correctly aligned. Under no
circumstances should the gate opener output sprocket carry any weight of the
gate. It is the task of the gate castors or wheels to carry the weight of the
gate.
· If the gate doesn’t slide freely by hand, adjust the height of the chain
accordingly until the full length of gate slides freely by hand.
· Ensure the chain is in proper tightness after installation. (refer to Figure
14)
9
www.gatexpertstore.com
Sprocket
Chain
Figure 13
Figure 14
Step 7 – Limit Switch Stop
Included in your gate opener kit are two limit switch stops which must be
fitted on your gate to ensure safe operation.
The limit switch stops are designed to set the desired opening and closing
position of your gate. When the limit switch stops come into contact with the
magnetic limit switch, the gate will stop moving.
It is extremely dangerous that without or incorrect installation of the limit
switch stops can cause crash of gate, damage of internal structure of the
motor, moreover, the gate may slide off the guide rail.
Setting the Limit Switch Stops
Closed Position · Position gate 150-200mm back from the gate end catch closed
position. This will help in
making sure you do not slam the gate into the end stop/catch when setting the
closed position under power. · Fit limit switch stop onto the top of chain at
the point where it meets the magnetic limit switch on the motor. · Tighten
locking screws of limit switch stop.
10
www.gatexpertstore.com
Magnetic limit switch
switch
Open Position · Position gate 150-200mm back from the gate stop open position.
This will help in making sure
you do not slam the gate into the end stop/catch when setting the open
position under power. · Fit limit switch stop onto the top of chain at the
point where it meets the magnetic limit switch on
the motor. · Tighten locking screws of limit switch stop.
Magnetic limit switch
switch
Test the magnetic limit switch stops by moving the gate manually until you
hear a click, making sure contact is made with the magnetic limit switch on
the motor.
Black magnet (N) Blue magnet (S)
Open Position Limit Switch Stop
Closed Position Limit Switch Stop
Figure 15
11
www.gatexpertstore.com
Motor Magnet Gate
Installation drawing of limit switch stop
Figure 16
To Reset: Turning the power off will reset the limit switch stop memory. Power
on the gate opener again, pressing remote control or external push button
switch to open and then close the gate once, then new limit switch stop
setting is completed.
Step 8 – Powering on
· Ensure that the outer cover has been fitted and fastened back onto the motor
base. · Before powering up the gate opener make sure the gate can travel by
hand in manual mode
(key unlocked). · Slide the gate to between the middle of the posts,
approximately (see below diagrams). · Lock the manual release spanner (key
locked) in readiness for automatic mode. · Plug the power cord into an
approved RCD protected weatherproof outlet. · Remote controls included in this
kit are factory paired ready for use.
Figure 17 12
www.gatexpertstore.com
Step 9 – Testing Travel and Limit Stops
Testing the Closed Position · Ensure gate opener is installed as per step 5, 6
and 7 and the sliding gate is in the middle
position. · Press remote (remotes included in kit are factory paired to the
motor). The sliding gate will
begin to close. · The limit switch stop will hit the limit switch and the
sliding gate will stop. · When the gate stops, measure the distance remaining
between the sliding gate and the desired
closed position. · You have now determined the closed position of the sliding
gate when the limit switch stop hits
the limit switch. · Adjust the limit switch stop from the measurement you have
taken to get your final gate closed
position. The ideal closed final position for the gate frame is 10-15mm from
closed gate end catch.
Testing the Open Position · Press remote, the sliding gate will begin to open.
· The limit switch stop will hit the limit switch and the sliding gate will
stop. · When the gate stops, measure the distance remaining between the
sliding gate and the desired
open position. · You have now determined the open position of the sliding gate
when the limit switch stop hits
the limit switch · Adjust the limit switch stops from the measurement you have
taken to get your final gate open
position. The ideal open final position for the gate frame is 10-15mm from the
gate stop.
To Reset: When setting new limit stop positions please ensure that you turn
the power off and then on again. Turning the power off will reset the limit
stop memory, allowing for new limit switch stop positions to be recognized by
the motor.
Figure 18
Now the basic open and closed positions are set, for further setting functions
and adjusting parameters, please refer to pages 14-46 in this manual.
13
www.gatexpertstore.com
Programming and Wiring
Any works to the 110V/220V AC must only be performed by a licensed
electrician. Ensure power is off before any modifications are made.
Indicator Light
Set Button
X7 Terminal
X6 Terminal X4 Terminal
X5 Terminal Hall Line
X2 Terminal
Motor Terminal
JP3 Terminal Figure 20
14
www.gatexpertstore.com
Terminal Instructions
All changes to these settings below must be completed by licensed electrician.
X7 Terminal: (as per Figure 20):
ANT: Extra Antenna GND: Extra Antenna Shield COM: Common Terminal for External
Push Button STP: External Stop Push Button Switch PED: External Close Push
Button Switch OSC: External Open Push Button Switch
X5 Terminal:
IR: Photocell Input Common Terminal for Photocell(N.C.) GND: Ground 12V:
Additional Accessories +12VDC, after gate closed in place, the board will
enter into low power consumption mode, this terminal will cut off the 12V
power supply. LAMP+: Alarm Lamp +12/24VDC LAMP-: Alarm Lamp -12/24VDC
Wiring to the Terminal
Using a screwdriver to loosen the screw on the side of the terminal.
Insert the wire into the number on the terminal that you are looking to connect to. Refer to Page 14.
Tighten with a screwdriver to secure the wire in place.
15
www.gatexpertstore.com
JP3 Terminal:
Turn on the buzzer when the jumper cap is inserted into the ON end, and turn
off the buzzer when the jumper cap is inserted into the OFF end.
Note:When the buzzer needs to be turned on, it is necessary to operate the
control board to enter the “Other Menu” mode, turn on the buzzer function, and
then plug the jumper cap into the ON end. At this time, the buzzer function
can be used normally.
X6 Terminal:
SIG: Output close signal after gate closed in place. OPLM: Open Limit Switch
COM: Limit Switch Common Terminal. CLLM: Close Limit Switch
X4 Terminal:
24VBAT+: Battery Positive 24VBAT-: Battery Negative Battery Specification:
24V/9Ah
12VBAT+: Battery Positive 12VBAT-: Battery Negative Battery Specification:
12V/9Ah Note: + and – must be wired correctly, wrong wring will damage the
control board.
X2 Terminal:
Power: Power Supply(Transformer Output) Transformer Specification:
240VAC/22VAC or 120VAC/22VAC Rated Power: 120W
16
www.gatexpertstore.com
Connecting Infrared Photocells
The below steps must be completed by licensed electrician.
Highly recommend the use of infrared photocells as an additional safety
feature.
While closing, if the ray of the Infrared Photocell is blocked, the gate will
stop and open immediately, to protect user and property security. To install
photocells, connect wiring as per Figure 21. You must remove the wire jumper
between terminal IR and terminal GND on X5 (ref to Figure 22). The distance
between photocell receiver and photocell transmitter should not be less than 2
meters; otherwise, the induction effect of photocell may be affected.
Photocell Receiver
Photocell Transmitter
Figure 21
17
www.gatexpertstore.com
Before Installing Photocells
Power off, then loosen IR and GND ports on X5 Terminal with a screwdriver.
Figure 22
Operation Interface Instruction
Remove the short circuit wire between ports IR & GND on X5 Terminal.
Figure 23
Indicator Lights:
L0 (Green): Indicating the control board working status and menu status. L1-L5
(Red): Indicating the settings, parameters, errors and battery level.
Set Buttons:
PROG: Enter into or exit the setting menu. – and +: Function select and
parameter adjust. SET: Choose the selection, confirm the setting. Note: Press
the setting button for a short while (within 1 sec.) or long press the button
(over 2 sec.) will be for different functions.
18
www.gatexpertstore.com
Manual Control Mode
In order to make sure that the first installation of this product is in good
condition, users can test the opening/closing running under manual control
mode. If there are any abnormalities, please exit the manual control mode and
re-adjust the gate, gate opener and the limit switch. A. Operation
Instruction: 1. Press and hold “SET” button for 3 sec. Indicator light L3 will
flicker. 2. Press “+” button to open the gate, then release “+” to stop
running; Press “-” to close the
gate, then release it to stop running. 3. Press “PROG” button once to exit the
manual control mode. Indicator light L3 will be
off. B. Operation Graphic Illustration
SET
Press “SET” for 3 sec.
L3 flicker
Press and hold “+” to open, release “+” to stop running. Press and hold “-” to close, release “+” to stop running.
PROG
Press “PROG” once
L3 off
Exit
Note: 1. If there is no operation under the limit switch position setting for
60 sec., system will
automatically exit the setting. 2. If need to exit during setting, press
“PROG” once to directly exit. 3. Under manual control mode, if the gate didn’t
stop when it arrived at limit switch, please
19
www.gatexpertstore.com
exit the manual control mode, and check if the two magnet limit switch stops
are within the detection range of the magnetic limit switch.
Quick Setting for Running Travel
Precondition: 1. Before setting the running travel, please make sure that the
gate is completely open. 2. Please install the limit switch stops at limit
switch position and make sure the polarities
are correct, after installed, please do not move or remove it anymore. A.
Operation Instruction a. Press “+” button for 2 sec., motor will automatically
start it’s travel learning. b. During gate closing, the indicator lights will
be on from L5 to L1 in sequence and repeatedly. c. During gate opening, the
indicator lights will be on from L1 to L5 in sequence and repeatedly. d. After
travel is set, the indicator lights L1-L5 will be on in sequence, then all
will flicker once and off. B. Operation Graphic Illustration 1. Enter into
Quick Setting:
Press “+” for 2 sec.
2. After Travel is Set:
During closing, L5 to L1 will be During opening, L1 to L5 will be on in sequence and repeatedly on in sequence and repeatedly
20
www.gatexpertstore.com
L1 to L5 will be on in sequence L1-L5 will flicker once then off
Save and exit
Note: 1. If there is no operation under the limit switch position setting for
60 sec., system will
automatically exit the setting. 2. If need to exit during setting, press
“PROG” once to exit.
Remote Control Management
Operation Instruction: 1. Press “-” button for 2 sec. under standby mode to
enter into the first function of remote
control management. 2. Different functions can be selected through “+” and “-”
buttons. 3. Press “SET” button to enter into the corresponding parameter
settings.
Standby Mode
Press “-” button for 2 sec.
L1 L2 L3 L4 L5
L1 L2 L3 L4 L5
L1 L2 L3 L4 L5
Single Button Mode Learning
Three-Button Mode Learning
Pedestrian Mode on Remote Control
Remote Control Management
L1 L2 L3 L4 L5
Remote Control Delete
Figure 24
21
www.gatexpertstore.com
Remote Control Mode Instruction: There are two modes available for remote control under this control board. Users may pair the remote control in their required mode.
1. Single button mode: Open/Stop/Close of the gate opener is controlled by
only one button on the remote control.
2. Three button mode: Open/Stop/Close of the gate opener is controlled by
three different
buttons on the remote control.
Single Button Mode Learning (L1)
Under this mode, one of the remote control buttons which is paired to the gate opener can
individually control the operation of one opener. The rest buttons on this remote control can
be used to pair to other openers. Gate 1
Gate 2
Gate 3
Gate 4
Figure 25
A. Operation Instruction 1. Press and hold “-” button for 2 sec. to enter into
remote control management mode.
Indicator light L1 will be steady on. 2. Press “SET” button once to enter into
single button learning mode. All indicator lights
will flicker repeatedly from L1 to L5. (If an alarm lamp is connected, it’ll
blink as well). 3. Press the button which is to be paired on the remote
control twice. The indicator lights
L1-L5 will be on in sequence, then all will flicker once and off. (If an alarm
lamp is connected, it’ll be on for one sec.). Learning is complete thereafter.
22
www.gatexpertstore.com
B. Operation Graphic Illustration
Press “-” for 2 sec. L1 will be steady on
SET
Press “SET” once
L1-L5 will flicker repeatedly
Press the button to be paired twice
L1-L5 will be on in sequence, then flicker once and off
Save and exit
Three-button Mode Learning (L2)
Under this mode, all buttons on the remote control which are paired to the gate opener will be separately used for gate openingclosing and stop. (Please refer to Figure 26 for the
usage for the forth button on the remote control) Open
Close
Stop
Pedestrian Mode
Figure 26
23
www.gatexpertstore.com
A. Operation Instruction 1. Press and hold “-” button for 2 sec. to enter into
remote control management mode.
Indicator light L1 will be steady on. 2. Press “+” button once to select three
button learning mode option. Indicator light L2
will be steady on. 3. Press “SET” button once to enter into three button
learning mode. All indicator lights
will flicker repeatedly from L1 to L5. (If an alarm lamp is connected, it’ll
blink as well) 4. Press the button which is to be paired on the remote control
twice. The indicator lights
L1-L5 will be on in sequence, then all will flicker once and off. (If an alarm
lamp is connected, it’ll be on for one sec.) Learning is complete thereafter.
B. Operation Graphic Illustration
Press “-” for 2 sec. L1 will be steady on
Press “+” once L2 will be steady on
Press “SET” once
L1-L5 will flicker repeatedly
Press the button to be paired twice
L1-L5 will be on in sequence
then flicker once and off
Save and exit
Note: If there is no operation under the remote control learning status for 20 sec., system
will automatically exit the setting and save all the paired remote controls.
Pedestrian Mode on Remote Control (L3)
Pedestrian mode function: when gate is closed, press the Pedestrian button on
the remote
24
www.gatexpertstore.com
control, the gate will open 1m wide to allow pedestrian access. A. Operation
Instruction: 1. Press and hold “-” button for 3 sec. to enter into remote
control management mode.
Indicator light L1 will be steady on. 2. Press “+” button twice to select
pedestrian mode function. Indicator light L3 will be
steady on. 3. Press “SET” button once to enter into pedestrian mode setting.
All indicator will
flicker repeatedly from L1 to L5. 4. Press the button which is to be paired on
the remote control once. The indicator
lights L1-L5 will be on in sequence, then all will flicker once and off..
Learning is complete thereafter. B. Operation Graphic Illustration:
Press “-” for 3 sec. L1 will be steady on
Press “+” twice
L3 will be steady on
SET
Press “SET” once
L1-L5 will flicker repeatedly
Press the button to be paired twice
L1-L5 will be on in sequence, all together flicker once
Save and exit
Remote Control Delete (L4)
This operation will delete all the remote controls that are paired to this
control board. A. Operation Instruction: 1. Press and hold “-” button for 2
sec. to enter into remote control management mode.
25
www.gatexpertstore.com
Indicator light L1 will be on. 2. Press “+” button three times to select
remote control delete option. Indicator light L4
will be on. 3. Press “SET” button once to enter into remote control delete
option. Indicator lights
L1-L5 will be steady on. 4. Press and hold “SET” button for 2 sec. will delete
all remotes and it will automatically
exit. Indicator lights will be off in sequence from L5 to L1, after which
indicator lights L1-L5 will be on for one sec. B. Operation Graphic
Illustration:
Press “-” for 2 sec. L1 will be steady on Press “+” 3 times
L4 will be steady on
SET
Press “SET” once
L1-L5 will be steady on
SET
Press “SET” for 2
sec.
L1-L5 will be on in sequence, all together flicker once
Remotes delete and exit
Remote Control Quick Learning
Remote control quick learning function enables user to pair the remote
controls without opening the motor cover. Precondition: 1. To have one remote
control that has already been paired.
26
www.gatexpertstore.com
2. To ensure the reliability of learning, please operate the quick learning
function within 2 meters from the gate opener.
3. Please make sure that the gate opener is equipped with an alarm lamp,
which will help you to check the status of remote control learning.
A. Operation Instruction: 1. Simultaneously press and hold the third and the
fourth buttons of the paired remote control for 6 sec. The alarm lamp will
flash, which indicates that the learning function of the control board is on
working. 2. Press the button to be learned on the remote control under the
above status. The alarm lamp will be off. Then remote control learning is
complete. 3. The system will automatically exit the learning mode after
pairing finished.
Note: The remote control working mode will be copied from original one to new
paired one. B. Operation Graphic Illustration:
Press these 2 buttons Alarm lamp flash
together for 6 sec.
Press the button to be paired twice
Alarm lamp off
Save and exit
Basic Menu Setting
Operation Instruction: 1. Under standby mode, press and hold “PROG” button for
3 sec., the indicator light L0 will flicker once and enter into basic menu
setting. 2. Press “+” or “-” button to select the different function settings.
3. Press “SET” button to enter into the selected function setting.
27
www.gatexpertstore.com
Standby Mode
PPrreessss aannddhohlodl”d +”P”RbOutGto”n ffoorr 33sseec.c.
L1 L2 L3 L4 L5
L1 L2 L3 L4 L5
Running Speed Setting
Slow Stop Speed Setting
L1 L2 L3 L4 L5
L1 L2 L3 L4 L5
Auto-reverse When Meeting AObstacles Setting
Slow Stop Distance Setting
Basic Menu Setting
Figure 27
L1 L2 L3 L4 L5 Auto-close Function Setting
Running Speed Setting (L1)
Users can adjust the gate opening and closing speed according to the actual
installation and using condition. A. Operation Instruction: 1. Press and hold
“PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “SET” button once to
enter into running speed setting. Indicator lights L1-L5
will show the current running speed. (The default is L5) 3. Press “+” or “-”
button to adjust the running speed. Indicator lights L1-L5 will indicate
different speed status. The more the indicator lights are on, the faster the
running speed will be. 4. Press “SET” button to save and system will
automatically exit. The indicator lights L1-L5 will be on in sequence, then
all will flicker once and off. B. Operation Graphic Illustration
28
www.gatexpertstore.com
PROG
Press “PROG” for 3
sec.
L0 flicker once, L1 will be steady on
SET
Press “SET” once
Press “+” or “-” to set, LED will show the setting value
SET
Press “SET” once
L1-L5 will be on in sequence then all flicker once and off.
Save and exit
Slow Stop Speed Setting (L2)
The setting for slow stop speed can effectively reduce the inertial force when
the gate is open or closed to its limit position, which will extend the
lifetime of both gate and gate opener. A. Operation Instruction: 1. Press and
hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “+” button to select
slow stop speed setting. Indicator light L2 will be steady on. 3. Press “SET”
button once to enter into setting mode. Indicator lights L1-L5 will show
the current slow stop speed. (The default is L2) 4. Press “+” or “-” button to
adjust the slow stop speed. Indicator lights L1-L5 will show
the different speed status. The more the indicator lights are on, the faster
the slow stop speed will be. 5. Press “SET” button to save and system will
automatically exit. The indicator lights L1-L5 will be on in sequence, then
all will flicker once and off. B. Operation Graphic Illustration
29
www.gatexpertstore.com
PROG
Press “PROG” for
3 sec.
L0 flicker once, L1 will be steady on
Press “+” once
L2 will be steady on
SET
Press “SET” once
Press “+” or “-” to set, LED will show the setting value
SET
Press “SET” once
L1-L5 will be on in sequence then all flicker once and off.
Reverse When Meeting Obstacles Setting (L3)
Save and exit
During the gate opening or closing, accidental collision with obstacles may
pose a threat to people and property. In order to prevent impact of such
collision, users may adjust the sensitivity of meeting obstacles to reduce the
impact damage. A. Operation Instruction: 1. Press “PROG” button for 3 sec. to
enter into basic menu. Indicator light L0 will flicker
once, then L1 will be steady on. 2. Press “+” button twice to select the
reverse option. Indicator light L3 will be steady
on. 3. Press “SET” button once to enter into setting mode. Indicator lights
L1-L5 will show
the current setting. (The default is L3) 4. Press “+” or “-” button to set the
sensitivity of meeting obstacles. Indicator lights
L1-L5 will show the different sensitivity of meeting obstacles. The less the
indicator lights are on, the more the sensitivity will be. L1-L5 are all off
means to cancel the Auto-reverse function.
30
www.gatexpertstore.com
5. Press “SET” button once to save the setting and system will automatically
exit. The indicator lights L1-L5 will be on in sequence, then all will flicker
once and off.
B. Operation Graphic Illustration
PROG
Press “PROG” for 3 sec.
L0 flicker once, L1 will be steady on
Press “+” twice
SET
L3 will be steady on Press “SET” once
Press “+” or “-” to set, LED will show the setting value
SET
Press “SET” once
L1-L5 will be on in sequence then all flicker once and off.
Save and exit
Note: The default setting of this function is suitable for gate weighting 500kg and the glide rail for running the gate is smooth, if this function is not workable or reverse frequently, please adjust the settings to reduce or increase a little bit.
Slow Stop Distance Setting (L4)
Setting a slow stop distance enables the gate to run more smoothly, which will
extend the service life of gate and gate opener. A. Operation Instruction: 1.
Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator
light L0
will flicker once, then L1 will be steady on. 2. Press “+” button three times
to select slow stop distance option. Indicator light L4 will
be steady on. 3. Press “SET” button once to enter into slow stop distance
setting. Indicator lights
L1-L5 will show the current distance of slow stop. (The default is L3) 4.
Press “+” or “-” button to set the slow stop distance. Indicator lights L1-L5
will show
31
www.gatexpertstore.com
the different slow stop distance. The more the indicator lights are on, the longer the distance will be. If the gate is heavy(over 800kg), it is recommended to set it on L4 or L5 to have a better slow stop running. If the gate weight is less than 500kg, it is recommended to set it on L2 or L1 to have a better slow stop running. 5. Press “SET” button once to save and system will automatically exit. The indicator lights L1-L5 will be on in sequence, then all will flicker once and off. B. Operation Graphic Illustration
PROG
Press “PROG” for 3 sec.
L0 flicker once, L1 will be steady on
Press “+” 3 times
SET
L4 will be steady on Press “SET” once
Press “+” or “-” to set, LED will show the setting value
SET
Press “SET” once
L1-L5 will be on in sequence then all flicker once and off.
Save and exit
Auto-close Function Setting (L5)
When the gate is completely open, the control board will send the auto-close
signal to enable the gate to close automatically according to the pre-set
auto-close time. A. Operation Instruction: 1. Press and hold “PROG” button for
3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “+” button four times
to enter into Auto-close option. Indicator light L5 will be
steady on. 3. Press “SET” button once to enter into setting. Indicator lights
L1-L5 will show the
current auto-close time. (The default is all indicator lights off)
32
www.gatexpertstore.com
4. Press “+” or “-” button to set the auto-close time. The number of steady
on indicator lights will indicate the Auto-close time. (Table 1 Auto-Close
Time)
5. Press “SET” button once to save and system will automatically exit. The
indicator lights L1-L5 will be on in sequence, then all will flicker once and
off.
B. Operation Graphic Illustration
PROG
Press “PROG” for 3 sec.
L0 flicker once, L1 will be steady on
SET
Press “+” 4 times L5 will be steady on Press “SET” once
Press “+” or “-” to set, LED will show the setting value
SET
Press “SET” once
L1-L5 will be on in sequence then all flicker once and off.
Save and exit
Indicator light status Off On Flicker
L1
L2
L3
L4
L5
L1
L2
L3
L4
L5
L1
L2
L3
L4
L5
L1
L2
L3
L4
L5
L1
L2
L3
L4
L5
L1
L2
L3
L4
L5
Status Instruction Cancel Auto-close function Auto-close after 10 sec. Auto- close after 20 sec. Auto-close after 30 sec. Auto-close after 40 sec. Auto- close after 50 sec.
Table 1 Auto-Close Time
33
www.gatexpertstore.com
Advanced Menu Setting
1. Press “PROG” button for 3 Sec. under the standby mode, indicator light L0
will flicker once to enter into basic menu setting. Press “PROG” button again
for 3 sec. indicator light L0 will flicker twice to enter into the advanced
menu setting.
2. Different functions can be selected through “+” and “-” buttons. 3. Press
“SET” button to enter into the selected function settings
Standby Mode
Press “PROG” button for 3 sec., indicator light L0 will flicker once
Basic Menu Setting
Press “PROG” button again for 3 sec., indicator light L0 will flicker twice
Working Mode Setting
Acceleration Setting
Start-up Delay Setting Opening Direction Setting Alarm Lamp Setting
Advanced Menu Setting
Figure 28
Working Mode Setting (L1)
Due to the usage for this product is different for users from different regions, the control board for this product offers 3 different working modes for users to choose. 1. Standard Mode (L1): Terminals for external buttons: OSC: Single button control PED: Pedestrian button STP: Stop button 2. Three Button Mode (L2): Terminals for external buttons: OSC: Opening button PED: Closing button STP: Stop button 3. Community Mode (L3): Terminals for external buttons:
34
www.gatexpertstore.com
OSC: Single button control PED: Pedestrian button STP: Stop button Special
function: Only the gate is completely open, can it be closed thereafter. If
the gate is not completely open, then only opening and stop can be operated in
order to prevent any interruption which will trigger closing during the
opening travel operated by the first user. A. Operation Instruction: 1. Press
and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “PROG” button again for
3 sec. to enter into advanced menu. Indicator light L0
will flicker twice, then L1 will be steady on. 3. Press “SET” button once to
enter into working mode setting. Indicator lights L1-L3
will show the current selection. (The default is L1) 4. Press “+” or “-”
button to select the working mode. Indicator lights L1-L3 will show the
current selection. 5. Press” SET” button once to save and system will
automatically exit. The indicator
lights L1-L5 will be on in sequence, then all will flicker once and off. B.
Operation Graphic Illustration
PROG
Press “PROG” for 3 sec.
L0 flicker once, L1 will be steady on
PROG
Press “PROG” again for 3 sec.
L0 flicker twice, L1 will be steady on
SET
Press “SET” once
Press “+” or “-” to set, LED will show the setting value
SET
Press “SET” once
L1-L5 will be on in sequence then all flicker once and off.
Save and exit
35
www.gatexpertstore.com
Acceleration Setting (L2)
Due to the different installation environment and gate installation status,
users can adjust the acceleration of starting and deceleration of buffering of
the gate opener to their necessary. A. Operation Instruction: 1. Press and
hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “PROG” button again for
3 sec. to enter into advanced menu. Indicator light L0
will flicker twice, then L1 will be steady on. 3. Press “+” button once to
select acceleration option. Indicator light L2 will be steady
on. 4. Press “SET” button once to enter into acceleration setting. Indicator
lights L1-L5 will
show the current acceleration value. (The default is L2) 5. Press “+” or “-”
button to set the acceleration value. Indicator lights L1-L5 will indicate
the different acceleration values. The more the indicator lights will be on,
the faster the speed changes. 6. Press” SET” button once to save and system
will automatically exit. The indicator lights L1-L5 will be on in sequence,
then all will flicker once and off. B. Operation Graphic Illustration
36
www.gatexpertstore.com
PROG
Press “PROG”
for 3 sec.
L0 flicker once, L1 will be steady on
PROG
Press “PROG” L0 flicker twice, L1 again for 3 sec. will be steady on
Press “+” once
L2 will be steady on
SET
Press “SET” once
Press “+” or “-” to set, LED
SET
L1-L5 will be on in sequence then all
will show the setting value Press “SET” once flicker once and off.
Save and exit
Start-up Delay Setting (L3)
The control board of this product is with low power consumption function under
standby mode. When the gate opener stopped working, the control board will
automatically enter into low power consumption mode to reduce the power
consumption and extend the using time of the battery. Meanwhile, in order to
reduce the power consumption of external accessories under standby mode, the
control board will turn off the power for infrared sensor after entering into
standby mode. When the gate opener is about to operate, it’ll supply the power
for accessories. In order to ensure the reliability of the infrared sensor, it
is requested that the control board performs delay detection to the input
signal of infrared sensor. When the gate opener receives the opening/closing
signal, it’ll start to work after a certain time (the settled delay time) A.
Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to enter
into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “PROG” button again for
3 sec. to enter into advanced menu. L0 will flicker
37
www.gatexpertstore.com
twice, then L1 will be steady on. 3. Press “+” button twice to select start-up
delay setting. Indicator light L3 will be steady
on. 4. Press “SET” button once to enter into start-up delay setting. Indicator
lights L1-L3 will
show the current setting. (The default is L1) 5. Press “+” or “-” button to
set the start-up delay time. Indicator lights L1-L3 will show
the current setting. (Table 2 Start-up Delay Time) 6. Press “SET” button once
to save and system will automatically exit. The indicator
lights L1-L5 will be on in sequence, then all will flicker once and off. B.
Operation Graphic Illustration
PROG
Press “PROG”
for 3 sec.
L0 flicker once, L1 will be steady on
PROG
Press “PROG”
again for 3 sec.
L0 flicker twice, L1 will be steady on Press “+” twice
L3 will be steady on
SET
Press “SET” once
Press “+” or “-” to set, LED
SET
L1-L5 will be on in
will show the setting value
sequence then all Press “SET” once flicker once and off.
Save and exit
38
www.gatexpertstore.com
Indicator light status Off On Flicker
L1
L2
L3
L4
L5
L1
L2
L3
L4
L5
L1
L2
L3
L4
L5
L1
L2
L3
L4
L5
Status Instruction Cancel start-up delay function Delay for 0.5 sec Delay for 1 sec Delay for 1.5 sec
Table 2 Start-up Delay Time
Opening Direction Setting (L4)
This setting is for users to change the gate opening direction without
exchanging the motor wires, but have to note the limit stop position. A.
Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to enter
into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “PROG” button again for
3 sec. to enter into advanced menu. L0 will flicker
twice, then L1 will be steady on. 3. Press “+” button three times to select
opening direction option. Indicator light L4 will
be steady on. 4. Press “SET” button once to enter into opening direction
setting. Indicator light L1 will
indicate the current setting. (Default is L1 on) 5. Press “+” or “-” button to
set the opening direction. Indicator light L1 on or off stands
for the 2 directions. (L1 on: open to right-hand; L1 off: open to left-hand)
Press “SET” button once to save and system will automatically exit. The
indicator lights L1-L5 will be on in sequence, then all will flicker once and
off.
39
www.gatexpertstore.com
B. Operation Graphic Illustration
PROG
Press “PROG” for L0 flicker once, L1
3 sec.
will be steady on
PROG
Press “PROG” again for 3 sec.
L0 flicker twice, L1 will be steady on
Press “+” for 3 times
L4 will be steady on
SET
Press “SET” once
Press “+” or “-” to set, LED will show the setting value
SET
L1-L5 will be on in
Press “SET” once sequence then all flicker once and off.
Save and exit
Note: After changing the opening direction, L1 and L2 will flicker together,
it’s a notice that reminding you to re-set the running travel for the gate.
Before re-setting, it’s extremely important to enter into manual control mode
to confirm the polarities of the limit switch stops are correct and well
contacted to the magnetic limit switch.
Alarm Lamp Setting(L5)
This setting is to select the working mode of alarm lamp (blinker or steady
on) A. Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to
enter into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “PROG” button again for
3 sec. to enter into advanced menu. L0 will flicker
twice, then L1 will be steady on. 3. Press “+” button four times to select
alarm lamp working mode option. Indicator light
L5 will be steady on. 4. Press “SET” button once to enter into alarm lamp
working mode setting. Indicator
40
www.gatexpertstore.com
light L1 will show the current setting. 5. Press “+” or “-” button to set the
alarm lamp working mode. Indicator light L1 on or off
will indicate the alarm lamp working mode. (L1 off: blinker; L1 on: steady on)
6. Press “SET” button once to save and system will automatically exit. The
indicator
lights L1-L5 will be on in sequence, then all will flicker once and off. B.
Operation Graphic Illustration
PROG
Press “PROG” for
3 sec.
L0 flicker once, L1 will be steady on
PROG
Press “PROG”
again for 3 sec.
L0 flicker twice, L1 will be steady on
Press “+” for 4 L5 will be steady on times
SET
Press “SET” once
Press “+” or “-” to set, LED will show the setting value
SET
L1-L5 will be on in
sequence then all Press “SET” once
flicker once and off.
Save and exit
Other Menu Setting
1. Press “PROG” button for 3 Sec. under the standby mode, indicator light L0
will flicker once to enter into basic menu setting. Press “PROG” button again
for 3 sec. indicator light L0 will flicker twice to enter into the advanced
menu setting. Then press “PROG” button for 3 sec., the indicator light L0 will
flicker three times then enter into other menu setting.
2. Different functions can be selected through “+” and “-” buttons. 3. Press
“SET” button to enter into the selected function settings.
41
www.gatexpertstore.com
Basic Menu
Press “PROG” for 3 sec., L0 will flicker once
Advanced Menu Press “PROG” again for 3 sec., L0 will flicker twice
Other Menu Press “PROG” for 3 sec. for the third time, L0 will flicker three
times
Emergency Stop Distance
Buzzer Setting
Setting
Other Menu Setting
Figure 29
Emergency Stop Distance Setting(L1)
This setting is to change the distance of emergency stop during gate running.
A longer distance will reduce the damage to the gate brings by impact force of
emergency stop. Users can set the distance to their required. A. Operation
Instruction: 1. Press and hold “PROG” button for 3 sec. to enter into basic
menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “PROG” button again for
3 sec. to enter into advanced menu. L0 will flicker
twice, then L1 will be steady on. 3. Press “PROG” button for 3 sec. for the
third time to enter into other menu setting. L0
will flicker three times, then L1 will be steady on. 4. Press “SET” button
once to enter into emergency stop distance setting. Indicator
light L1 to L5 will show the current setting value. (Default is L2)
42
www.gatexpertstore.com
5. Press “+” or “-” button to set the emergency stop distance. Indicator
lights L1-L5 will indicate different distance, the more the indicator lights
are on, the longer the distance will be, the better the buffering will be
before gate stopped.
6. Press “SET” button once to save and system will automatically exit. The
indicator lights L1-L5 will be on in sequence, then all will flicker once and
off.
B. Operation Graphic Illustration
PROG
Press “PROG” for L0 flicker once, L1
3 sec.
will be steady on
PROG
Press “PROG”
again for 3 sec.
L0 flicker twice, L1
PROG
Press “PROG” for
will be steady on 3 sec.
L0 flicker 3 times, L1 will be steady on
SET
Press “SET” once
Press “+” or “-” to set, LED
SET
L1-L5 will be on in
sequence then all
will show the setting value Press “SET” once
flicker once and off.
Save and exit
Note: 1. This function can directly affect the infrared emergency stop effect.
Non
professionals should not adjust it. 2. Only when the emergency stop distance
is set to the minimum (only L0 lights up),
the door opener will immediately stop and retreat to the closed position after
triggering infrared when closing the door. But the impact force generated
during an emergency stop will reduce the lifespan of the door opener.
3. When the emergency stop distance increases (excluding “minimum emergency
stop distance”), the door opener will slowly slide for a certain distance
before stopping and
43
www.gatexpertstore.com
retreating to the closing position after triggering infrared when closing the
door. This setting can effectively reduce the damage caused to the door opener
during emergency stop, but the emergency stop triggered by infrared is no
longer sensitive when closing the door. Please adjust it as needed to be
careful not to cause personal injury and property damage due to improper
setting.
Buzzer Setting(L2)
This setting is to enable or disable the buzzer, users can set to their
required. There are four types of buzzer this motor will make for different
conditions:
1. Motor works normally under mains power: the buzzer sounds short but long
lasting.
2. Motor works normally under battery power: the buzzer sounds strident but
long lasting, and will stop after 6 sec.
3. Motor works abnormal due to low battery power: the buzzer sounds strident
but long lasting, and will stop after 3 sec.
4. Motor works abnormal due to control board error: the buzzer sounds
strident but long lasting.
A. Operation Instruction: 1. Press and hold “PROG” button for 3 sec. to enter
into basic menu. Indicator light L0
will flicker once, then L1 will be steady on. 2. Press “PROG” button again for
3 sec. to enter into advanced menu. L0 will flicker
twice, then L1 will be steady on. 3. Press “PROG” button for 3 sec. for the
third time to enter into other menu setting. L0
will flicker three times, then L1 will be steady on. 4. Press “+” button twice
to select buzzer setting option. Indicator light L2 will be steady
on. 5. Press “SET” button once to enter into buzzer setting. Indicator light
L1 on or off will
44
www.gatexpertstore.com
indicate the current setting value. (Default is L1 off) 6. Press “+” or “-”
button to enable or disable the buzzer. Indicator light L1 off: enable;
on: disable. 7. Press “SET” button once to save and system will automatically
exit. The indicator
lights L1-L5 will be on in sequence, then all will flicker once and off. B.
Operation Graphic Illustration
PROG
Press “PROG” for L0 flicker once, L1
3 sec.
will be steady on
PROG
Press “PROG” again for 3 sec.
PROG
L0 flicker twice, L1 Press “PROG” for
will be steady on 3 sec.
L0 flicker three times, L1 will be steady on
SET
Press “SET” once
Press “+” or “-” to set, LED will show the setting value
SET
L1-L5 will be on in
sequence then all Press “SET” once
flicker once and off.
Save and exit
Note: The buzzer cannot be disabled under battery powered.
After turning on the buzzer function, when the motor is running normally and
the buzzer is still not working, please check whether the “JP3 terminal” is
inserted at the ON end.
Battery Level Checking
The current battery level can be checked through the indicator lights. When
the battery power is low (battery voltage 11.3V), the gate opener will stop
running to protect the battery being damaged. Under such circumstance, users
may have to unlock the gate
45
www.gatexpertstore.com
opener first, then move the gate by hand. A. Operation Instruction: 1. Press
“SET” button once. Indicator lights L1-L5 will indicate the current battery
level
(Table 3 Battery Level) 2. Press “PROG” button once to exit the battery level
checking. Indicator lights L1-L5
will be off.
B. Operation Graphic Illustration
SET
L1-L5 will indicate the
PROG
Press “SET” once current battery level Press “PROG” once
L1-L5 off
Exit
Indicator Light Status Off
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
On Flicker
L4
L5
L4
L5
L4
L5
L4
L5
L4
L5
L4
L5
Status Instruction Battery Level 12.6V Battery Level 12.3V Battery Level 12.0V Battery Level 11.7V Battery Level 11.3V Battery Level 11.3V
Table 3 Battery Level
Restore Factory Setting
1. Simultaneously press the three buttons “SET””+” and “-” for 3 sec. The
indicator lights L1-L5 will be on in sequence, then all will flicker once and
off. Save and exit.
46
www.gatexpertstore.com
SET
Press “SET” “+” and
“-” together for 3 sec.
L1-L5 will be on in all flicker once and off sequence
Save and exit
Control Board Error Instruction
The indicator light will display the error during gate running:
Indicator Light Status Off
Flicker
Status Instruction
L1
L2
L3
L4
L5
L1
L2
L3
L4
L5
Meeting obstacles during gate opening Meeting obstacles during gate closing
L1
L2
L3
L4
L5
L1
L2
L3
L4
L5
Running time over 60S Infrared photocell disconnecting
L1
L2
L3
L4
L5
No hall sensor
L1
L2
L3
L4
L5
No travel
Table 4 Error Instruction
Maintenance
The gate should be checked every month to make sure it operates normally. For
the sake of safety, each gate is suggested to be equipped with infrared
protector, and regular inspection is required. Before installation and
operation of the gate opener, please read all instructions carefully. Our
company keep the right to change the instruction without prior notice.
47
www.gatexpertstore.com
Troubleshooting
Any troubleshooting work below done to the motor must be completed by a
licensed electrician and only whilst the power is off and the motor is
unplugged!
Problem The gate cannot open or close normally, indicator light doesn’t on.
The gate can only open, can’t close.
Remote control doesn’t work. Press OPEN, CLOSE button, the gate is not moving,
motor has noise.
Arrived at open or closed limit switch, but motor didn’t stop.
Leakage switch tripped.
Possible Reason 1. The power supply is disconnected. 2. Fuse is blown. 3.
Control board X2 terminal wrongly wired.
1. Photocell wrongly wired. 2. Photocell wrongly installed. 3. Photocell is
blocked by objects. 4. Sensitivity of meeting obstacle is too high.
1. Battery level is too low. 2. Remote control not paired. 1. Gate moving is
not smoothly. 2. Hall sensor damaged.
1. Magnetic limit switch damaged. 2. Polarities of the two limit switch stops
are opposite. 3. Hall sensor part damaged. Power supply wires short circuit or
motor wires short circuit.
Solution 1. Connect the power supply. 2. Check the fuse (FU) and replace
if blown. 3. Re-wiring according to this user
manual. 1. If not connect photocell, please ensure the infrared terminal and
GND terminal has a jumper wire; if connect photocell, please ensure the wiring
is correct and the photocell type is N.C. 2. Ensure that the photocell
mounting position can be mutually aligned. 3. Remove the obstacle. 4. Reduce
the sensitivity of obstacle. 1. Change the battery. 2. Pair the remote control
to the gate opener. 1. Adjust the motor or gate according to the actual
situation. 2. Replace the hall sensor.
1. Change the magnetic limit switch. 2. Switch over the two limit switch
stops. 3. Change the hall sensor part.
Check wiring.
Drawing and Measurements
48
www.gatexpertstore.com
Figure 30
49
www.gatexpertstore.com
References
Read User Manual Online (PDF format)