GATEXPERT GKB220E Industrial Door Operator with Electronic Limit Switch User Manual
- June 13, 2024
- GATEXPERT
Table of Contents
- GATEXPERT GKB220E Industrial Door Operator with Electronic Limit Switch
- WARRANTY
- Safety Instruction
- Technical Parameter Table of Door Operator
- Technical Parameter Table of Control Unit
- Dimension and Component of Industrial Door Operator
- Installation Guide of Industrial Door Operator
- Industrial Door Operator Wiring
- Operation Interface Illustration
- Open and Closed Limit Switch Setting
- Working Mode Setting3
- Parameters Setting
- External Accessories Wiring
- Remote Control Password Setting
- Use of Hand-pulled Chain
- Common Faults and Countermeasures
- PACKING LIST
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GATEXPERT GKB220E Industrial Door Operator with Electronic Limit Switch
- Website: www.gatexpertstore.com
- E-mail: sales@gatexpertstore.com
WARRANTY
- To repair against this warranty card and invoice during the warranty period.
- Warranty period: 1 year after the date of invoice.
- Without unauthorized dismantling, any product broken or damage due to quality problem, we’ll offer the repair service for free or replace for free.
- The malfunction and damages caused by incorrect use or man fault is not covered by this warranty.
CONTACT US
- E-mail: sales@gatexpertstore.com
- Please fill in the order information in the form below.
- All personal information you provided will be only used for warranty service and kept strictly confidential.
- Refer to this list when contacting GATEXPERT for technical service or assistance with your automatic gate opener.
Order Number| Product Model| Purchase Date| Country / Region
---|---|---|---
| | |
Email Address|
Issue Details|
Safety Instruction
- The industrial door operator should be installed and put into operation by qualified personnel. Otherwise, serious personal injury or property damage may occur.
- Installation and wiring must be in accordance with the construction standards and electrical standards, diameter ≧ 1.5mm2; power must have a reliable grounding, ground wire must be reliably connected to the place labeled ground tab, ground lead on the power line is prohibited to be removed; front end of incoming power line should be installed with electrical leakage protector which is in line with national standards.
- This industrial door operator is only allowed to be installed on well-balanced door which has balance spring, otherwise machine may be damaged due to overload.
- Door should be flexible and run without stagnation; The end of door lead rail must be installed with mechanical stop block and buffering booster to prevent the door from rolling out.
- Control unit should be installed on the wall or a post of 1.4 meters away from the ground where the operation of door can be observed to prevent children from inadvertently touching. Keep the remote control well, do not allow children to touch or play in case of any danger. Do not use the remote control when you didn’t see the operation of door.
- Before repairing and moving the industrial door operator and its control unit, please cut off the power supply, and make sure that the door has been locked and there is no any risk of falling due to self-weight is null.
- Pedestrian and vehicle are prohibited to go through or stay when the door is running.
- Hand-pulled chain is prohibited to be pulled during the operation of the industrial door operator to prevent the motor from damaged.
- To ensure the safety of pedestrian and vehicle, it’s recommended to install the infrared protection and airbag protection devices.
- Please check the safety protection devices and the door running condition from time to time to ensure the safety and stability of door operation.
- Thank you for choosing this product!
- Appreciate for your trust and support!
- Please read this manual carefully before installation!
- Please keep this manual properly even after installation!
Technical Parameter Table of Door Operator
Model (Single Phase AC220V±10%) | INDUS40E | INDUS60E | INDUS100E |
---|---|---|---|
Rated Power | 300W | 400W | 550W |
Torque | 40N.m | 60N.m | 100N.m |
No-load Continuous Running Time | 15 min. | 8 min. | |
Max. gate area | 20m2 | 25m2 | 35m2 |
Model (Three Phase AC380V±10%) | INDUS60SE | INDUS100SE | INDUS150SE |
Rated Power | 400W | 550W | 750W |
Torque | 60N.m | 100N.m | 150N.m |
Max. gate area | 30m2 | 40m2 | 50m2 |
No-load Continuous Running Time | 15 min. |
Other Parameters:
Thermal Protection Temperature| 120℃
Reduction Ratio| 1:58
No-load Rotation Speed| 24r/min
Lubricating System| Oil-immersed
Noise| ≤55dB
Hand Release Device| 360°Hand-pulled chain
Maximum Travel Limit| Output shaft rotates 20 rounds
Output Shaft Diameter| Φ25.4mm
Environment Temperature| -20℃ ~+50℃
Working Duty| S2-15min
Protection Class| IP54
Operator Dimension(mm)| 232x151x368
Operator Weight(kg)| 14
Technical Parameter Table of Control Unit
Model | GKB220E | GKB380E |
---|---|---|
Power Supply | AC220V/50Hz | AC380V/50Hz |
Remote Control | Available | Available |
Applicable Model | INDUS40E/60E/100E | INDUS60SE/100SE/150SE |
External Three Button Switch Terminal | Available (Optional) | Available |
(Optional)
External Single Button Switch Terminal| Available (Optional)| Available
(Optional)
Partial Opening Button Switch Terminal| Available (Optional)| Available
(Optional)
Interlock Terminal| Available (Optional)| Available (Optional)
Infrared Photocell Terminal| Available (Optional)| Available (Optional)
Airbag Terminal| Available (Optional)| Available (Optional)
Loop Detector Terminal| Available (Optional)| Available (Optional)
Small-door Terminal| Available (Optional)| Available (Optional)
Multi-function Output Terminal| Available (Optional)| Available (Optional)
DC24V Power Terminal| Available (Optional)| Available (Optional)
Protection Class| IP54| IP54
Dimension and Component of Industrial Door Operator
- Electronic limit switch part
- Gearbox
- Plastic cover
- Wiring terminals
- Door operator
- Adjusting screw
- Hand-pulled chain
Component
- Control Unit Dimension
Installation Guide of Industrial Door Operator
This product is commonly used for the industrial sectional door which was equipped with balance spring and lifting industrial door. There are two installation ways for this product: shaft drive installation and chain drive installation. The factory standard configuration is for shaft drive installation. If users require chain drive type, they can choose the appropriate sprocket chain accessories for installation needs.
Shaft Drive Installation | Chain Drive Installation |
---|---|
① Expansion Screw | ① Driven Wheel |
② Mounting Bracket | ② Door Shaft |
③ Mounting Screw | ③ Chain |
④ Door Operator | ④ Mounting Bracket |
⑤ Special Flat Key | ⑤ Driving Sprocket |
⑥ Door Shaft | ⑥ Driving Sprocket Shaft |
⑦ Fixing Sleeve | ⑦ Door Operator |
Step 1. Check the door
After the door is installed, adjust the torsion spring, ensure manually
opening or closing the door is flexible without stagnation, observe the
rotation direction of the rope sheave which should be consistent with the
opening and closing direction of the industrial door operator.
Step 2. Determine the installation position
Consider the boundary dimension and installation direction of the door
operator, determine the position of the mounting bracket, mark the insert
cavity position, drill the screw hole and fix the mounting bracket. (The
mounting bracket can be fixed inside or outside the door operator, recommended
to be installed inside for the convenience of disassembly of the door
operator).
Step 3. Trial installing the door operator
Install a fixing sleeve on door shaft first, and insert the industrial door
operator into the door shaft.
Step 4. Pre-fix the industrial door operator
Fix the industrial door operator on mounting bracket with 4pcs hexagon head
flange bolts M10×20, do not tighten at this step.
Step 5. Find the direction of key slot
Rotate the output shaft of the industrial door operator by pulling the hand-
pulled chain up and down until the key slot of the output shaft is fully
aligned with the key slot of the door shaft. (Note: When releasing the hand-
pulled chain, make sure that the hand-pulled chain has been reset
successfully.)
Step 6. Mount the flat key and fixing sleeve
Mount the flat key, keep two fixing sleeves close to the two ends of the
output shaft, fasten the two M8 head screws in the key slot of door shaft in
order to prevent the flat key from loosening and falling off.
Step 7. Tighten the screws, prepare wiring and debugging
- Tighten all screws.
Industrial Door Operator Wiring
Wiring Between Door Operator and Control Unit
- Motor Wire
- Encoder Wire
- Power Supply Wire
Wiring of Single Phase Operator
- Motor Wire: U(blue) V(brown) W(black)
- Encoder Wire: GND(white) A(yellow) B(red) VCC(green)
- AC220V(single phase) Power Supply Wire
Note: Please make sure the wirings are tight and in good connection. After wiring, remember to tighten up the IP plug to ensure all wirings completely fixed.
Warning: Please ensure the power supply wire is not plugged before you finish all wirings.
Wiring of Three Phases Operator
- Motor Wire: U(blue) V(brown) W(black)
- Encoder Wire: GND(white) A(yellow) B(red) VCC(green)
- AC380V(three phases) Power Supply Wire
Note:
- Please make sure the wirings are tight and in good connection. After wiring, remember to tighten up the IP plug to ensure all wirings completely fixed.
- Please notice the phase sequence change when reconnecting wires. If the phase sequence changed, the motor will run in opposite. The digital screen won’t display abnormal if the phase sequence is correct.
Warning: Please ensure the power supply wire is not plugged before you finish all wirings.
Operation Interface Illustration
Open and Closed Limit Switch Setting
Working Mode Setting3
After these 2 steps, please check if the door running condition is to your standard, if it’s good, you don’t have to do any other settings, the door will work properly. If it’s not good, you should adjust the relative parameters.
Note:
- Please adjust the door operator with the buttons on the control unit.
- After adjustment, please make some trial running first, make sure everything is correct, fit the control unit on a post that can be observed by you and should be 1.4 high from the ground to keep it away from Children.
DIP Switch Setting:
ON(Up Position); OFF(Down Position)
- No.1: ON-Mechanical Limit Switch; OFF-Electronic Limit switch
- No.2: No function
- No.3: No function
- No.4: ON-Remote Control in Single Button Mode; OFF-Remote Control in Three Buttons Mode;
- No.5: ON-Enable Phase Sequence Detection;
- OFF-Disable Phase Sequence Detection
Input Status
Input Status
No.| Instruction
1| Stop
2| Open
3| Close
4| Photo Sensor
5| Air Bag
6| Loop Detector
7| Partial Opening
8| Single Cycle
9| Interlock
Parameters Setting
No. | Parameters | Value Range | Default |
---|
P1
P1-F1| Electronic limit switch setting| |
P1-F2| Pre-stop before arriving at the open limit switch position| 0-200| 50
P1-F3| Pre-stop before arriving at the closed limit switch position| 0-200| 60
P1-F4| Delay time for Auto-close| 0-120 sec.| 10
P1-F5| Height of partial opening| 0-100%| 50
P1-F6| Inch move for opening| 0=Continuously
move;1=Inch move
| 0
P1-F7| Inch move for closing| 0=Continuously
move;1=Inch move
| 0
P1-F8| Restore to factory setting of P1| 0=No;1=Yes| 0
P2
P2-F1| Stop of external three buttons switch| 0=NO;1=NC| 0
P2-F2| Partial opening| 0=NO;1=NC| 0
P2-F3| Single cycle| 0=NO;1=NC| 0
P2-F4| Photo sensor| 0=NO;1=NC| 0
P2-F5| Loop detector| 0=NO;1=NC| 0
P2-F6| Airbag| 0=NO;1=NC;2=pulse| 0
P2-F7| Mechanical limit switch| 0=NO;1=NC| 1
P2-F8| Restore to factory setting of P2| 0=No;1=Yes| 0
---|---|---|---
P3
P3-F1| Multi-function of F1| 0=NO;1=NC| 0
P3-F2| Multi-function of F2| 0=NO;1=NC| 0
P3-F3
| ****
F1
| Close| 0| ****
0
Fault output| 1
Door completely open in place output| 2
Door partially open in place output| 3
Not open limit switch output| 4
Closed in place output| 5
Not closed limit switch output| 6
Door in running output| 7
Air curtain signal output| 8
Force on| 9
P3-F4| F2| Same as P3-F3
P3-F5| Inter-lock function| 0=Disable; 1=Enable| 0
P3-F6| Limit height of infrared photocell valid| 1-1500| 100
P3-F7| Limit height of airbag valid| 1-1500| 50
P3-F8| Locked rotor time| 1-7| 4
P3-F9| Restore to factory setting of P3| 0=No;1=Yes| 0
P4
P4-F1| Alarm of running over the open limit switch| 10-200| 80
P4-F2| Alarm of running over the closed limit switch| 10-200| 100
P4-F3| Open limit switch position check| Read only|
P4-F4| Closed limit switch position check| Read only|
P4-F5| Current position check| Read only|
P4-F6| Restore to factory setting of P4| 0=No;1=Yes| 0
P4-A3
| ****
Display backlight selection
| 0=60sec. automatically energy saving;
1=always on
| ****
0
P5(Initial password:00000)
P5-F1| Total running times setting| 0-99999| 99999
P5-F2| Total running days setting| 0-99999| 99999
P5-F3| Total running days checking| Read only|
P5-F4| Total running times checking| Read only|
P5-F5| Change your password| 00000-99999| 00000
P5-F6| Restore to factory setting of P1- P4| 0=No;1=Yes| 0
External Accessories Wiring
- External three-buttons switch terminal: “STOP” terminal type is NO by default, if you need NC type, please modify the setting of “P2-F1” to be “1”.
- External partial opening button switch terminal: terminal type is NO, if you need NC type, please modify the setting of “P2-F2” to be “1”. The height of partial opening can be adjusted under setting “P1-F5”.
- External single cycle button switch terminal: terminal type is NO, if you need NC type, please modify the setting “P2-F3” to be “1”.
- Safety photocell terminal: terminal type is NO, if you need NC type, please modify the setting of “P2-F4” to be “1”. The valid height of photocell can be adjusted under “P3-F6”.
- Safety airbag terminal: There are 2 signal types of safety airbag: level signal and pulse signal, factory default is level single in NO type, if require NC type or pulse signal, you can change it under setting of “P2-F6”. The valid height of airbag can be adjusted under “P3-F7”
- Loop detector terminal: default is NO, if require NC, please modify the setting of “P2-F5” to be “1”. Loop detector signal is only valid under automatic control mode, invalid under manual control mode.
- Small door interlock terminal: default is NC, if require to connect with small door, please remove the jumper wire between “DIND” and “COM”
- Relay terminal output: default is NO, if require NC type, please modify the setting of “P3-F1” or “P3-F2”to be “1”. Output logic function can be selected under “P3-F3” and “P3-F4”.
- Two doors interlock: connect terminal “ILIN”of control unit 1 to terminal “ILOUT” of control unit 2. Connect terminal “ILOUT”of control unit 1 to terminal “ILIN” of control unit 2. Connect terminal “COM” of control unit 1 to terminal “COM” of control unit 2. Please remember to change the parameter of “P3-F5” to be 1 if you enable this two doors interlock function.
- 220V alarm lamp terminal: Alarm lamp should be 220V, wire to D1 and D2 terminals.
Remote Control Password Setting
Remote control pairing:
Press AN button on the receiver, LED light will flash once, press any one of
the buttons on the remote (normally button A), LED light will flash for 4
seconds then off, remote control pairing is complete. If require to pair
another remote control please repeat the above pairing steps, each PC board
can be paired with 25 remote controls in max.
Note: Only need to pair “button A”, the pairing of the remote control is finished meanwhile.
Remote control delete:
Press and hold AN button on the receiver, LED light will be on, release the
button until the LED light is off, all paired remote controls are deleted.
Note: Recommended to operate the remote control deletion first and re-p air the remote before you use the operator for security consideration.
Use of Hand-pulled Chain
When you drive the industrial door manually, hand-pulled chain is needed. Hand-pulled chain should be operated by evenly continuous force, to avoid to damage the hand-pulled chain mechanism by furiously pulling. In the process of pulling the chain, the protective switch in the hand-pulled chain mechanism will automatically cut off the power supply. When the chain is released, the protective switch in the hand-pulled chain mechanism will be automatically reset to restore the normal electric use of the industrial door operator. When the hand-pulled chain is not in use, please fix the hand-pulled chain to the wall in the appropriate way.
When using a period of time, if the chain can not smoothly open or close the door, please adjust the adjustment screw on the hand-pulled chain clockwise (as shown in the right) until the door can be opened normally by the hand- pulled chain.
Note:
- After the chain is used, if digital displays E–06, the door cannot be opened or closed electrically, because protection switch in the hand-pulled chain mechanism has not been automatically reset. Slightly lift the chain up and down, the control unit can work properly until the E–06 is off.
- In the process of electrically opening or closing of door, chain is strictly prohibited to be pulled, to avoid any accidents.
- Hand-pulled chain is used for special circumstances such as power outage only, and cannot be used as a long-term normalized operating.
Note: Please make monthly check on the opening and closing travel of the door operator, if the up and down limit switch is still accuracy, if the door is balance, if not, please adjust it timely. If necessary, please ask for professionals’ help to repair and adjust.
Common Faults and Countermeasures
No. | Trouble | Possible Cause | Countermeasures |
---|
1
| ****
The digital screen is off.
| The power supply is not connected or the wires is
loose.
| Tighten the screw of the wiring and re-power on.
The emergency stop terminal is loose or emergency stop button is not reset.|
Reinsert the emergency stop terminal or reset the emergency stop button.
Power has input, while transformer without voltage output. Transformer has
damaged in transit.
| ****
Replace the circuit board.
The fuse is burnt.| Replace the fuse.
2
| ****
E-01
Power supply phase-loss
| Phase sequence of three phases power supply is not correct.
Phase sequence detection function is working.
| Cut off the power supply, exchange two of the L1, L2 or L3, after changed
correctly, the E-01 will disappear.
Phase-loss of three phases power supply.| Check with a multimeter which phase
is lost, and re-wire.
3| E-02
Encoder disconnect
| Encoder was not connected or wrongly connected.| Re-connect the encoder.
4| E-03
Limit switch abnormal
| Up and down limit switch was not set or was set over the
travel.
| ****
Re-set the limit switch.
5| E-04
Maintenance notice
| Exceed the scheduled running cycles or time| Please contact supplier for solution.
6
| ****
E-05
Motor stalling
| The door balance spring is not working or the door is meeting obstacles, motor can’t drive the door caused motor stalling.| ****
Adjust the balance spring.
Rail is deformed, find the obstacle and remove it
7
| ****
E-06
Thermal protection
| ****
Thermal protection or hand chain protection
| Waiting for the motor to cool down.
Pull up and down chain to reset the switch
8
| E-07
Door in door mode abnormal
| ****
The smaller door is open or damaged.
| Close the smaller door to enable it’s normal running.
Make sure the wiring between DIND and COM are good.
9
| ****
Remote control doesn’t work
| The remote control indicator light is off| Change the battery.
The transmitter does not match the receiver.| Re-set the remote control
password.
PACKING LIST
Door Operator Packing List INDUS40E 、 INDUS60E 、 INDUS100E 、
INDUS60SE 、 INDUS100SE 、 INDUS150SE
No.| Name| Qty.| Note
1| Door operator| 1|
2| Mounting bracket| 1|
3| Fixing sleeve| 2| Contain M6×10 fastening screw
4| Special flat key| 1| 6×70
5| Hexagon bolts| 4| M10x20
7| User manual| 1|
8| Motor four-core wire| 1| 5 meter
9| Limit switch four-core wire| 1| 5 meter
Control Unit Packing List
GKB220E 、 GKB380E
No.| Name| Qty.| Note
1| Control unit| 1|
2| Remote control| 2|
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>