GATEXPERT DKC500AC-2 Sliding Gate Opener User Manual
- May 15, 2024
- GATEXPERT
Table of Contents
DKC500AC-2 Sliding Gate Opener
“`html
Specifications:
-
Model: DKC500AC-2/DKC800AC-2
-
Power Supply: AC110V/220V
-
Backup Power: DC backup battery or solar power not
compatible -
Warranty Period: 1 year
Product Usage Instructions:
Installation:
-
Read the instructions carefully before installation.
-
Ensure the power cable is unplugged when mounting and
positioning the product. -
Remove the motor cover to mount the motor to the mounting plate
or directly to the concrete footing. -
Any changes to settings must be made by a licensed
electrician.
Default Setting Instruction:
The gate opener defaults to opening the gate to the right-hand
side. To test before installation, plug the opener into a power
source and press the remote for opening and closing operations.
Gate Opening Direction:
If your gate needs to open from the left-hand side, mount the
opener on the left-hand side and swap the relative wires
accordingly.
Safety Precautions:
- Ensure the gate opener is unplugged during installation.
- Avoid touching the motor output gear while it is turning.
- All work on the gate opener should be done with power off and
the opener unplugged.
FAQ:
Q: Can I use a DC backup battery or solar power with this
product?
A: No, this product is only compatible with AC110V/220V power
supply.
Q: How long is the warranty period?
A: The warranty period is 1 year from the date of invoice. Refer
to the warranty card and invoice for repairs covered under
warranty.
“`
Sliding Gate Opener User Manual
DKC500AC-2/DKC800AC-2
Website: www.gatexpertstore.com E-mail: sales@gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
WARNING
Instructions must be read before installation. Please follow these
instructions carefully, incorrect installation could affect gate operation.
When mounting and positioning this product please ensure the power cable is
unplugged.
The motor cover will need to be removed to mount the motor to the mounting
plate or directly to the concrete footing.
Any changes to the settings on this product can only be made by a licensed
electrician. This product is only powered by AC110V/220V power supply; DC
backup battery or solar
power is not compatible.
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
WARRANTY
1. To repair against this warranty card and invoice during the warranty
period. 2. Warranty period: 1 year after the date of invoice. 3. Without
unauthorized dismantling, any product broken or damage due to quality problem,
we’ll offer the repair service for free or replace for free. 4. The
malfunction and damages caused by incorrect use or man fault is not covered by
this warranty.
CONTACT US
E-mail: sales@gatexpertstore.com
Please fill in the order information in the form below. All personal
information you provided will be only used for warranty service and kept
strictly confidential. Refer to this list when contacting GATEXPERT for
technical service or assistance with
your automatic gate opener.
Order Number Product Model
Purchase Date
Country / Region
Email Address Issue Details
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
CONTENTS
Default Setting Instruction………………………………………………………………………………………………..1 Safety
Instruction……………………………………………………………………………………………………………..2 Parts
List………………………………………………………………………………………………………………………….3 Technical
Parameters……………………………………………………………………………………………………….5
Installation……………………………………………………………………………………………………………………….5
Before You Start…………………………………………………………………………………………………………..5 Tools Required /
Example Sliding Gate………………………………………………………………………….5 Step 1 – Gate
Preparation………………………………………………………………………………………………6 Step 2 – Checking Manual
Release…………………………………………………………………………………6 Step 3 – Removing / Installing Motor
Cover………………………………………………………………………7 Step 4 Motor Pad
Footing……………………………………………………………………………………………8 Step 5 – Fitting Mounting Plate
and Motor…………………………………………………………………………8 Step 6 – Gear Rack & Motor
Alignment…………………………………………………………………………..10 Step 7 – Limit Switch
Stops…………………………………………………………………………………………..11 Step 8 – Powering
on………………………………………………………………………………………………….15 Step 9 – Testing Travel and Limit
Stops………………………………………………………………………….16 A Intelligent Control
Board………………………………………………………………………………………………17 Programming and
Wiring……………………………………………………………………………………………..17 DIP Switch
Adjustment………………………………………………………………………………………………..18 Potentiometer
Adjustment……………………………………………………………………………………………19 Terminal
Instructions…………………………………………………………………………………………………..20 Wiring to the
Terminal…………………………………………………………………………………………………21 Connecting Infrared
Photocells…………………………………………………………………………………….22 Remote Control
Operation…………………………………………………………………………………………..23 B Standard Control
Board……………………………………………………………………………………………….24 Programming and
Wiring……………………………………………………………………………………………..24 DIP Switch
Adjustment………………………………………………………………………………………………..25 Terminal
Instructions…………………………………………………………………………………………………..26 Wiring to the
Terminal…………………………………………………………………………………………………27 Connecting Infrared
Photocells…………………………………………………………………………………….28 Remote Control
Operation…………………………………………………………………………………………..29
Maintenance…………………………………………………………………………………………………………………..30
Troubleshooting……………………………………………………………………………………………………………..31 Drawing and
Measurements…………………………………………………………………………………………….32
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Default Setting Instruction
The gate opener will open the gate to the right-hand side as its default
setting. By default, the opener mounts on the right-hand side. (Figure 1)
Gate in closed position
Gate in open position
Figure 1
Before installation: Test the gate opener by plugging it into a power source and pressing the
remote. Press the opening button, the output gear rotates, then press the stop button, the output
gear stops rotating. Finally, press the closing button, the output gear rotates to the opposite
direction. This will give you an understanding of the way in which the opener will move the gate.
Press the first/top button on the remote.
Rotating output gear will drive the gate frame.
Then the gate will move in the set direction.
Figure 2
Note: Ensure that the gate opener is unplugged before proceeding with
installation. Please keep fingers away from the motor output gear whilst it is
turning.
If your gate needs to open from the other direction (to the left, refer to
figure 3), your opener needs to be mounted on the left-hand side as shown, the
relative wires need to be swapped over, please check under “Terminal
Instructions” for swapping. (Factory default setting is for right-hand
opening: opener mounted on the right-hand side).
Figure 3
Any works done to the gate opener must be completed whilst the power is off, and the opener is unplugged.
1
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Safety Instruction
Warning: Incorrect or improper use of this product can cause damage to
persons, animals or properties. · Please ensure that the input voltage used
matches with the supply voltage of gate opener. · All modifications to wiring
or electrics, and any adjustment or maintenance to input voltage
must be done by a qualified electrician. · All potential hazards and exposed
pinch points of the gate must be eliminated or guarded prior
to installation of this gate opener. · Never mount any device that operates
the gate opener where the user can reach over (under,
around or through) the gate to operate the controls. These must be placed away
from any moving range of the moving gate. · Ensure power plug is disconnected
from the power socket during installation or maintenance. · Keep remote
control and other control devices out of children’s reach, in order to avoid
unintentional activation. · To ensure safety, before installing the motor,
mount a Gate End Catch and a Gate Stop at each end of the rail to prevent the
gate travelling off the track. · If required, install infrared photocell to
detect obstructions and prevent injury to person or damage to property. ·
Instruct all users about the control systems provided and the manual opening
operation in case of emergency. · Ensure that the power cable is connected to
a RCD protected weatherproof power outlet installed by a qualified
electrician. · Do not install this product in an explosive atmosphere or where
there is any danger of flooding. · This product was exclusively designed and
manufactured for the use specified in the present documentation. Any other use
not specified in this documentation could damage the product and be dangerous.
· Only use original parts for any maintenance or repair operation. Our company
declines all responsibility with respect to the automation safety and correct
operation when other supplier’s components are used. · Do not modify the
automation components, unless explicitly authorized by our company. · The user
must avoid any attempt to carry out any works or repairs on this product, and
should always request the assistance of qualified personnel. · This product is
suitable for use on one sliding gate only. · Anything which is not expressly
provided for in these instructions is not allowed and will void warranty. ·
Dispose of all packing materials (plastic, cardboard, polystyrene etc.)
according to current guidelines. Keep plastic bags and polystyrene out of
children’s reach. · Save these instructions for future use.
2
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Parts List
Parts List (standard configuration)
No.
Picture
1
Name Motor
Quantity 1
2 3 4 4-1-1
4-1-2
5
Manual Release Keys
2
Remote Controls
2
Spring Limit Switch Accessories Box/ Magnetic Limit Switch Accessories Box
1
Spring Limit Switch Stop
Spring Limit Switch Stop Mounting Screw M6X10
Magnetic Limit Switch Stop
1 set 4
1 set
Magnets
2
Magnetic Limit Switch Stop Mounting Screws M6X18
4
Nuts M8
4
Flat Washers 8
2
Spring Washers 8
2
Anchor Bolt M8
4
3
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
No.
Picture
5-1
Name Nuts M8
Quantity 8
5-2 5-3
Parts List (optional)
No.
Picture
1
Flat Washers 8
8
Spring Washers 8
8
Note: Extra flat washers and spring washers are spare parts.
Name Galvanized Gear Rack
Quantity 1m/pc
2
Nylon Gear Rack
1m/pc
3
Infrared Photocell
1
4
Wireless Keypad
1
5
Alarm Lamp
1
6
Mounting Plate
1
7
Hexagon Head Bolt M8X40
4
Additional remote controls: Spare/Additional remotes for the automatic gate kit, these will need to be paired to the motor. Infrared photocell: Detects pedestrians, vehicles and objects that cross an infrared beam and prevents the gate from closing. Wireless keypad: Allows secure access through the gate used with a user set code. Wired control: Allow users to control the opening and closing of the door through an external push-button. Alarm lamp: Alerts people near the gate and users that the gate is in operation.
4
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Technical Parameters
Model Power Supply Motor Power Gate Moving Speed Maximum Loading Weight Remote Control Distance Remote Control Mode Limit Switch Working Noise Working Duty Recording of up Remote Controls Remote Frequency Working Temperature Package Weight
DKC500AC-2
DKC800AC-2
110VAC/60Hz; 220VAC/50Hz
280W
380W
13m/min
600KG
800KG
30m
Single button mode / Three button mode
Spring limit switch / Magnetic limit switch
56dB
58dB
S2, 20min
Standard control board: 25; Intelligent control board: 40
433.92 MHz
-20°C – +70°C
10.10KG
10.18KG
Installation
Before You Start · DKC500AC-2/DKC800AC-2 Sliding Gate Automation Kit is
suitable for powering the opening
and closing motion of gates up to 600, 800kg in weight, up to a length of 12m.
· Gate motion is achieved by the rotating output gear of the gate opener
driving the gear rack
(sold separately) fitted to the moving gate. · The gate opener requires you to
press the remote control once to open, and once again to
close. This is a safety feature to ensure safe operation. · The opener must be
fitted within private property, never externally to a property’s boundary.
Any works done to the gate opener must be completed whilst the power is off
and the opener is unplugged. Any modifications/alterations/works to AC power
components must only be completed by
a licensed electrician.
Tools Required
· Tape measure · Level · 12mm concrete drill and hammer (when uses expansion
screws) · Phillips head screwdriver · Straight screwdriver
5
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Example Sliding Gate
Gate Track and Track Wheels Gate End Catch
Gate Guide Rollers
Gate Stop
Figure 4 Please ensure that the gate opener power cable is not plugged in at any stage before Step 8.
Step 1 – Gate Preparation
· Ensure that the sliding gate is correctly installed. · The gate is
horizontal and level and the gate can glide back and forth smoothly when moved
by
hand before installing the gate opener. · Wheels and guide rollers should
rotate easily and be free from dirt or grime. · Track should be flat, level
and firmly affixed. · Any misalignment in the gate will affect performance of
the automatic gate opener.
The gate should slide smoothly by hand before attempting to install the gate opener. Figure 5
Step 2 – Checking Manual Release
· Insert the key and open the manual release bar to enable the motor get into
manual mode and check that the motor output gear rotates freely by hand
(Figure 6).
6
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Turn 90°
To make the motor into manual mode, insert the key and open the manual release
bar till it rotates by 90°.
Figure 6
In manual mode, the gear can turn freely and the gate can be operated by hand.
Step 3 – Removing / Installing Motor Cover
· Unscrew the two cover screws located at each side of the motor cover. ·
Remove the rubber grommet below the limit switch (Figure 7).
Figure 7
Please Note: the rubber grommet must be fitted back onto the motor cover once
the cover has been re-fitted/replaced onto the base of the motor.
7
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Step 4 – Motor Pad Footing
· The motor pad concrete footing requires an area of no less than 400mm long x
250mm wide and a minimum depth of 200mm (Standard requirement).
· Ensure surface is level and parallel to the driveway.
Mounting Plate Dimensions Figure 8
Step 5 – Fitting Mounting Plate and Motor
Without Mounting Plate · Pre embed the anchor bolts according to holes in
motor base before concerting (as per Figure 9). · Afater concrete hardening,
bolt the motor with spring and flat washers provided and tighten as
required. (The height can be slightly adjusted by bottom bolts as per Figure
10).
Figure 9
8
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Nut Spring Washer Flat Washer
Flat Washer Nut
The bolts and flat washer between mounting plate and motor base are used for
adjusting the height of the motor. Figure 10
With Mounting Plate · Pre embed the anchor bolts as per 10 holes in Figure 8
before concreting, after hardening,
place the mounting plate, fit and tighten anchor bolts (as per figure 11). ·
Bolt motor to the mounting plate using the M8 x 40mm bolts with spring and
flat washers
provided and tighten as required (as per figure 12).
Figure 11
Nut Spring Washer Flat Washer
Flat Washer Nut
The bolts and flat washer between mounting plate and motor base are used for
adjusting the height of the motor.
Figure 12
9
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Fitting Motor · Fit motor and mounting plate(if with) on the concrete footing.
· Ensure the motor output gear and gear rack are correctly aligned. Gear and
gear rack should
be centered as much as possible. · Take the motor away from mounting plate.
Sliding Gate Frame (in open position)
Use pencil, chalk or similar tools to mark at the corners of mounting plate
Figure 13
Step 6 – Gear Rack & Motor Alignment
· See Figure 15 for recommended gear rack mounting height. · Ensure that the
output gear has a minimum clearance of 1-2mm along the entire length of gear
rack fitted to the gate (as per Figure 14) · Ensure output gear and gear rack
are correctly aligned. Under no circumstances should the
gate opener output gear carry any weight of the gate. It is the task of the
gate castors or wheels to carry the weight of the gate (as per Figure 14). ·
If the gate doesn’t slide freely by hand, adjust the height of the gear rack
accordingly until the full length of gate slides freely by hand.
10
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Output Gear
Figure 14
Figure 15
Step 7 – Limit Switch Stops
Included in your gate opener kit are two limit switch stops which must be
fitted to the gear racks on your gate to ensure safe operation.
The limit switch stops are designed to set the desired opening and closing
position of your gate. These limit switch stops are designed to come into
contact with the spring/magnetic limit switch.
11
Limit switch stop Limit switch stop mounting screws
Gear rack
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
It is extremely dangerous that without or incorrect installation of the limit
switch stops can cause crash of gate, damage of internal structure of the
motor, moreover, the gate may slide off the guide rail.
Setting the Limit Switch Stops Closed Position · Position gate 150-200mm back
from the gate end catch closed position. This will help in
making sure you do not slam the gate into the end stop/catch when setting the
closed position under power. · Fit limit switch stop onto the top of gear rack
at the point where it meets the Spring/Magnetic limit switch on the motor. ·
Tighten locking screws of limit switch stop.
Spring limit switch
Magnetic limit switch
12
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2 Open Position · Position gate 150-200mm
back from the gate stop open position. This will help in making sure
you do not slam the gate into the end stop/catch when setting the open
position under power. · Fit limit switch stop onto the top of gear rack at the
point where it meets the Spring/Magnetic
limit switch on the motor. · Tighten locking screws of limit switch stop.
Spring limit switch
Magnetic limit switch
Test the spring/magnetic limit switch stops by moving the gate manually until
you hear a click, making sure contact is made with the spring/magnetic limit
switch on the motor. To Reset: Turning the power off will reset the limit
switch stop memory. Power on the gate opener again, pressing remote control or
external push button switch to open and then close the gate once, then new
limit switch stop setting is completed.
13
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Open Position Limit Switch Stop
Closed Position Limit Switch Stop
The installation of spring limit switch stops is shown in figure above.
Open Position Limit Switch Stop
Closed Position Limit Switch Stop
The installation of magnetic limit switch stops is shown in figure above.
Motor cover
Spring limit switch Mounting plate
14
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Motor cover
Magnetic limit switch
Mounting plate
Open Position
Step 8 – Powering on
· Ensure that the outer cover has been fitted and fastened back onto the motor
base. · Before powering up the gate opener make sure the gate can travel by
hand in manual mode
(key unlocked). · Slide the gate to between the middle of the posts,
approximately (see below diagrams). · Lock the manual release spanner (key
locked) in readiness for automatic mode. · Plug the power cord into an
approved RCD protected weatherproof outlet. · Remote controls included in this
kit are factory paired ready for use.
Figure 16 15
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Step 9 – Testing Travel and Limit Stops
Testing the Closed Position · Ensure gate opener is installed as per step 5, 6
and 7 and the sliding gate is in the middle
position. · Press remote (remotes included in kit are factory paired to the
motor). The sliding gate will
begin to close. · The limit switch stop will hit the limit switch and the
sliding gate will stop. · When the gate stops, measure the distance remaining
between the sliding gate and the desired
closed position. · You have now determined the closed position of the sliding
gate when the limit switch stop hits
the limit switch. · Adjust the limit switch stop from the measurement you have
taken to get your final gate closed
position. The ideal closed final position for the gate frame is 10-15mm from
closed gate end catch.
Testing the Open Position · Press remote, the sliding gate will begin to open.
· The limit switch stop will hit the limit switch and the sliding gate will
stop. · When the gate stops, measure the distance remaining between the
sliding gate and the desired
open position. · You have now determined the open position of the sliding gate
when the limit switch stop hits
the limit switch · Adjust the limit switch stops from the measurement you have
taken to get your final gate open
position. The ideal open final position for the gate frame is 10-15mm from the
gate stop.
To Reset: · When setting new limit stop positions please ensure that you turn
the power off and
then on again. Turning the power off will reset the limit stop memory,
allowing for new limit switch stop positions to be recognized by the motor.
Now the basic open and closed positions are set, for further setting functions and adjusting parameters, please refer to pages 16-29 in this manual.
16
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
A Intelligent Control Board
Programming and Wiring
Any works to the 110V/220V AC must only be performed by a licensed
electrician. Ensure power is off before any modifications are made.
Potentiometers
Dip Switches
Learn Button
Hall Sensor
J5 Terminal
J6 Terminal J4 Terminal J3 Terminal
J2 Terminal
Fuse (10A 250V fuse)
Figure 17
17
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
DIP Switch Adjustment
All changes to these settings must be completed by a licensed electrician
Figure 18
Number Function
Description
1
Soft Start/Close Function
OFFenabled ONdisabled Default position is OFF.
OFFNormal Open
ONNormal Close
2
Limit Switch Setting Default position is ON, this should align with limit
switch and is not recommended to be modified by
the users.
Automatic close time setting: the gate is operated to
3
open by remote control operation and will close
automatically after a few seconds delay.
4
Automatic Close Time Setting
3 OFF 4 ON: automatic close delay time is 12s. 3 ON 4 OFF: automatic close delay time is 24s. 3 ON 4 ON: automatic close delay time is 36s. 3 OFF 4 OFF: no automatic close function.
Default setting: 3 OFF 4 OFF
Disable the automatic close function.
OFF-enable
ON-disable
5
Auto-reverse Function Default position is OFF, this should align with the
opener status and is not recommended to be
modified by the users.
6
Remote Control Mode OFF-single channel mode
(optional) Switch
ON-four channel mode
(optional):If your control board only has five dials, it is invalid.
18
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Potentiometer Adjustment
All changes to these settings must be completed by a licensed electrician
Figure 19
VR1: Stall Force Mode Maximum = More Force = Less sensitive Minimum = Less
Force = More sensitive
When Stall Force Mode is enabled (Dip switch 5 is at OFF position), the gate
opener will detect obstacles and impacts to the gate. If this is during
opening, the gate will stop, if this is during closing the gate will stop, and
then re-open. Rotate VR1 clockwise to increase the stall force, anti-clockwise
to decrease.
For safety, we strongly recommend that Stall Force Mode is left enabled (Dip
switch 5 is at the OFF position). Do not turn Dip switch 5 to the ON position.
VR2: Brake Force Adjustment For adjusting brake force at the limit position
during gate opening and closing. This should only be adjusted for heavy gates
that need additional force to brake when limit switch is detected. Rotate VR2
clockwise to increase, counter-clockwise to decrease. Default setting is at
minimum.
VR3: Slow Start/Stop Width Adjustment This switch controls how many seconds
the gate opener operates at maximum speed. Rotate VR3 clockwise to increase,
rotate counter-clockwise to reduce. When VR3 switches to minimum, slow
start/stop function is disable.
VR4: Motor Output Force Adjustment For best performance, set the torque at the
lowest setting for secure use. Rotate clockwise to increase, counter-clockwise
to decrease. Default setting is at maximum.
19
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Terminal Instructions
All changes to these settings below must be completed by licensed electrician.
J2 Terminal (as per Figure 15):
Terminal 6: External Push Button Pedestrian Switch Terminal 5: External
Open/Stop/Close/Stop Loop Control Push
Button (Repeated Open/Stop/Close) Terminal 4: Common Terminal for All External
Control Push
Button Terminal 3: External Stop Push Button Switch. Terminal 2: External Open
Push Button Switch. Terminal 1: External Close Push Button Switch.
J5 Terminal: Limit Switch and Accessories
Additional accessories sold separately
Terminal 13: Open Limit Switch Terminal 12: Limit Switch Common Terminal
Terminal 11: Close Limit Switch Terminal 10: Loop Detector Connector (Pre-
wired by Factory) Terminal 9: Ground/Earth (GND) Terminal 8: Photocell input
(N.C.). If no photocell is fitted, use
a jumper between terminals 8 & 9. Terminal 7: Power supply for accessories
(+15V)
Note: If require to change the moving direction, the wires of 11 and 13 on J5
Terminal have to be swapped with each other.
20
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Wiring to the Terminal
Using a screwdriver to loosen the screw on the side of the terminal.
Insert the wire into the number on the terminal that you are looking to connect to. Refer to Page 17.
Tighten with a screwdriver to secure the wire in place.
J6 Terminal: Motor Capacitor
J4 Terminal: MOT1: Motor Terminal, swap with MOT2 to change gate moving
direction. MOT2: Motor Terminal, swap with MOT1 to change gate moving
direction. MOTCOM: Motor Common Terminal. LAMP (L&N): Connection for warning
lamp. PE: Motor and warning lamp earth Note: If require to change the moving
direction, not only MOT1 and MOT2 wires need to be swapped, but also the wires
of 11 and 13 on J5 Terminal have to be swapped with each other.
J3 Terminal: PE: Earth (yellow/green wire). L: Power (brown wire). N: Power
(blue wire).
21
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Connecting Infrared Photocells
The below steps must be completed by licensed electrician.
Highly recommend the use of infrared photocells as an additional safety
feature.
While closing, if the ray of the Infrared Photocell is blocked, the gate will stop and reverse immediately, to protect user and property security. To install photocells, connect wiring as per Figure 20. You must remove the wire jumper between terminal 8 and terminal 9 on J5 (ref to Figure 21). The distance between photocell receiver and photocell transmitter should not be less than 2 meters; otherwise, the induction effect of photocell may be affected.
Photocell Transmitters
Photocell Receiver
2 co2re cable
3 c3ore cable
Before Installing Photocells
Figure 20
Loosen 8 and 9 ports on J5 Terminal with a screwdriver. Make sure the power is disconnected before doing so.
Figure 21
Remove the wire jumper between ports 8 & 9 on J5 Terminal.
22
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Remote Control Operation
Three button mode remote control: OPEN/CLOSE/STOP of motor are controlled by
three buttons separately on the remote control. Single button mode remote
control: OPEN/CLOSE/STOP of motor are controlled by one button circularly on
the remote control. The forth button on remote control is Pedestrian
Mode–press the forth button while the gate is closed, the gate will open 1m
wide to allow pedestrian access.
Open
Stop
Open Close Stop
Close
Pedestrian Mode
Pedestrian Mode
Three Button Mode Remote Control
Single Button Mode Remote Control
Figure 22
Remote Control Learning
Remove motor outer cover and continue to remove the transparent PCB cover, press the
button S1′ on the control board, until the
LEARN’ indicator light turns on,
then release the
button. While the light is on, press the button intended to be paired on the remote control
twice, the `LEARN’ indicator light will flash repeatedly and then turn off when remote control
is paired. A maximum 40 remote controls can be paired to one motor.
Press and hold learning
While the light is on,
The Learn LED will flash
button(S1) until the Learn
press the first button on
repeatedly and then turn off,
LED flashed on.
the remote control twice
when the remotes is paired.
Clearing Remote Controls To delete all paired remote controls, press and hold the button `S1′ till LEARN LED turns on.
When the LEARN LED turns off, all previously paired remote controls will be deleted.
23
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
B Standard Control Board
Programming and Wiring
Any works to the 110V/220V AC must only be performed by a licensed
electrician. Ensure power is off before any modifications are made.
LEARN Button
Dip Switches
Motor Direction Switch
X3 Terminal X2Terminal X1 Terminal
X4 Terminal
X5 Terminal Figure 23
Fuse (10A 250V fuse)
24
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
DIP Switch Adjustment
All changes to these settings must be completed by a licensed electrician.
Figure 24
Number 1 2 3
Function
External Push Button Switch
Automatic Close Time
Description ON-Three button switch X4 Terminal OPN – Open, CLS – Close, STP –
Stop, COM – Common Terminal
OFF-Single button switch CLS and COM on X4 Terminal can be used to circularly
control OPEN/STOP/CLOSE/STOP of the gate opener. Automatic close time setting:
the gate is operated to open by remote control operation and will close
automatically after a few seconds delay. 2 ON 3 OFF: automatic close delay
time is 15s. 2 OFF 3 ON: automatic close delay time is 30s. 2 OFF 3 OFF:
automatic close delay time is 45s. 2 ON 3 ON: No automatic close function.
Default setting: 2 ON 3 ON Disable the automatic close function.
25
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Terminal Instructions
All changes to these settings must be completed by a licensed electrician
X5 Terminal: Limit Switch and Photocell Switch.
Additional accessories sold separately
24VDC: Positive Power Supply for Accessories +24VDC. GND: Negative Power
Supply for Accessories -GND. LR: Photocell Input (N.C.). If no photocell,
connect LR and GND by a jumper. CLLM: Close Limit Switch. COM: Limit Switch
Common Terminal. OPLM: Open Limit Switch.
X4 Terminal: External Push Button. COM: Common Terminal for External Push
Button. STP: External Stop Push Button Switch. CLS: External Close Push Button
Switch. OPN: External Open Push Button Switch.
Note: If require to change the moving direction, the CLLM and OPLM on X5
Terminal have to be swapped with each other.
26
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Wiring to the Terminal
Using a screwdriver to loosen the screw on the side of the terminal.
Insert the wire into the number on the terminal that you are
looking to connect to. Refer to Pages 24.
Tighten with a screwdriver to secure
the wire in place.
X1 Terminal: L: Live Wire (brown wire). N: Neural Wire (blue wire). PE: Grounding Wire (yellow/green wire).
X2 Terminal: PE: Earth V: Common Terminal of Motor. U: Motor Terminal. Switch
SW1 will change gate moving
direction. W: Motor Terminal. Switch SW1 will change gate moving
direction. Note: If require to change the moving direction, not only the the
switch SW1 need to be adjusted, but also CLLM and OPLM on X5 Terminal have to
be swapped with each other.
X3 Terminal: C C: Motor Capacitor D1 D2: Connection for warning lamp(AC220V).
27
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Connecting Infrared Photocells
The below steps must be completed by a licensed electrician.
Highly recommend the use of infrared photocells as an additional safety feature.
While closing, if the ray of the Infrared Photocell is blocked, the gate will stop and reverse immediately, to protect user and property security. To install photocells, connect wiring as per Figure 25. You must remove the wire jumper between GND and LR on X5 terminal (refer to Figure 26). The distance between photocell receiver and photocell transmitter should not be less than 2 meters; otherwise, the induction effect of photocell may be affected.
Photocell Receiver
Photocell Transmitter
3 Core Cable
2 Core Cable
Figure 25
28
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Loosen LR and GND on X5 Terminal with a screwdriver. Make sure the power is disconnected before doing so.
Figure 26
Remove the jumper wire between LR & GND on X5 Terminal.
Remote Control Operation
Three button mode remote control: OPEN/CLOSE/STOP of motor are controlled by three buttons separately on the remote control. Single button mode remote control: OPEN/CLOSE/STOP of motor are controlled by one button circularly on the remote control
Open
Close
Open
Close Stop
Stop
Three Button Mode Remote Control
Figure 27
Single Button Mode Remote Control
Remote Control Learning Remove the motor outer cover and continue to remove
the transparent PCB cover, press the button AN1′ on the control board, until the
LED2′ indicator light turns on, then release the button. While the light
is on, press the button intended to be paired on the remote control twice, the
`LED2′ indicator light will flash repeatedly and then turn off when remote
control is paired. A maximum 25 remote controls can be paired to one gate
opener.
29
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Press and hold the learn button (AN1) until `LED2′ flashes.
on
When the light is on, press the first button on the remote control twice.
on
off
The `LED2′ will flash
repeatedly and then turn
off. After which the remote
is paired.
Clearing Remote Controls To delete all paired remote controls, press and hold
the button AN1′, when the
LED2′ turns off, all previously paired remote
controls will be deleted.
Maintenance
The gate should be checked every month to make sure it operates normally. For
the sake of safety, each gate is suggested to be equipped with infrared
protector, and regular inspection is required. Before installation and
operation of the gate opener, please read all instructions carefully. Our
company keep the right to change the instruction without prior notice.
30
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Troubleshooting
Any troubleshooting work below done to the motor must be completed by a
licensed electrician and only whilst the power is off and the motor is
unplugged!
Problem The gate cannot open or close normally, and LED does not light.
The gate can only open, but cannot close.
Possible Reason 1. The power supply is disconnected. 2. Fuse is blown. 3. Control board X1 terminal wrongly wired. 1. Photocell wrongly wired. 2. Photocell wrongly installed. 3. Photocell is blocked by objects. 4. Sensitivity of obstacle is too high (Intelligent type). 5. Hall sensor parts damaged (Intelligent type).
Remote control doesn’t work.
Press OPEN, CLOSE button, the gate is not moving, motor has noise.
1. Battery level is too low. 2. Remote control not paired. 1. Capacitor damaged. 2. Capacitor is poor connected. 3. Gate moving is not smoothly
Not stop when running to opening or closing limit switch position.
1. The opening or closing limit switch is in opposite. 2. Magnetic limit switch badly installed.
Leakage switch tripped.
Power supply cable short circuit or motor wire short circuit.
Solution 1. Connect the power supply. 2. Check the fuse (FU) and replace if
blown. 3. Re-wiring according to user manual. 1. If not connect photocell,
please ensure the infrared port and GND port has a jumper wire; if connect
photocell, please ensure the wiring is correct and the photocell status is
N.C. 2. Ensure that the photocell mounting position can be mutually aligned.
3. Remove the obstacle. 4. Reduce the sensitivity of obstacle. 5. Replace hall
sensor parts. 1. Change the battery. 2. Pair the remote control to the gate
opener.
1. Change capacitor. 2. Check the capacitor wiring. 3. Adjust the motor or
gate according to the actual situation.
1. Check whether the limit switch wiring is consistent with the motor running
direction. 2. Check whether the distance and height between magnetic limit
switch and motor reaches to standard requirement.
Check wiring.
31
www.gatexpertstore.com
Instructions for DKC500AC-2/DKC800AC-2
Drawing and Measurements
Figure 28
32
www.gatexpertstore.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>