GE Lighting 93100346 Motion Sensor Integrated LED Outdoor Wall Light Installation Guide
- June 13, 2024
- GE Lighting
Table of Contents
GE Lighting 93100346 Motion Sensor Integrated LED Outdoor Wall Light
PACKAGE CONTENTS
HARDWARE PACKAGE
TOOLS REQUIRED
SPECIFICATIONS
INSTALLATION
Warning: Before wiring the fixture to the house power supply, ensure the electricity is TURNED OFF at the main circuit breaker or fuse box.DO NOT ATTEMPT TO INSTALL FIXTURE WITH THE POWER ON. All wiring connections must be made with the POWER OFF to avoid personal injury and/or damage to the fixture. Verify power is OFF at the junction box using AC voltage tester before installation. If using ladder for installation, ensure ladder base is secure and stable before attempting light fixture installation.
-
Select Mounting location.
-
NOTE: The fixture (I) is WET rated for Outdoor use and should be mounted to a recessed electrical junction box with a 120-Volt AC power source ideally connected through a wall switch.
-
NOTE: The fixture (!) should be mounted approximately 10ft. (3m] above the ground.
-
Turn off power source to the junction box that you are installing the fixture in.
-
Remove the Mounting bracket(E) from the back of outdoor fixturell).
-
Install the mounting bracketlE) to Junction Box. The bracket has slots to accommodate 2.75 or 3.5-inch mounting centers.
- NOTE: Six Mounting bracket screws (A, B or C) of three sizes are included. The installation will only require one set of two screws.
- Remove the existing outdoor fixture and disconnect house AC Power supply wires (Black, white and ground.
- Install the mounting bracketlE) with the selected screws, with the fixture mounting screws pointing out from the junction box. Use the mounting bracket screws (A, B or C) that best fit the junction box.
- Fit mounting bracketlE) to the box ensuring the fixture screws are horizontal.
- Tighten the mounting bracket screws.
-
Slide gasket(F) over mounting screws and pull supply wires through center of gasket.
-
Make the electrical connections.
-
WARNING: Before wiring the fixture to the house power supply, ensure the electricity is TURNED OFF at the main circuit breaker or fuse box. DO NOT ATTEMPT TO INSTALL FIXTURE WITH THE POWER ON. All wiring connections must be made with the POWER OFF to avoid personal injury and/ or damage to the fixture.
Verify power if OFF at the junction box using AC voltage tester before installation. -
Connect black wire from outlet box to black wire from fixture. Connect white wire from outlet box to white wire from fixture. Connect ground wire from outlet box to ground wire from fixture. Secure wires together with Wire connecter IG).
~ Mako cure fivturo le oriontated corrocthy rofor to lID arrowe chow holow -
Make sure fixture is orientated correctly, refer to UP arrows shown below.
-
-
Mount the fixturelI) to the mounting bracketlE)
- Put the fixture(l) on the Mounting bracket(E) with two screws through the hole on fixture.
- Take the nut screw(H) from hardware package, put nut screwtH) into the hole at the front of fixture, tighten nut screw(H) with tool.
- Complete second nut screw(H) installation.
- Put the Rubber screw hole plug(D) into the hole at the front of fixture.
- For wet locations, a line of caulking compound such as acrylic latex or silicone must be placed around the perimeter of backplate also contacting the flange (as shown) to seal against mounting surface keeping water away from the outlet box and back openings.
-
Once the fixture is secured, open the cover and set the fixture controls. Turn power on.
Motion detection zone
The sensor will be more sensitive to motion across its detection path than
motion directly towards it.
The detector is more sensitive to motion across its field of view and
environment condition.
Function and Operation Manual
Operation Switch
Operation Steps
-
Built in Dusk to Dawn Sensor
Day: Light will operate all the time.
Dusk: Light will operate from dusk to dawn. At dawn the lamp will stop operating.
Night: Light will operate from Night to dawn. -
The activation timer determines the amount of time the light will stay on full brightness after last motion is detected.
- Timer can be set to 10s, 30s, 3min, 10min and Always. Setting the timer to always will always maintain light output on desired fixture.
-
Setting Sensitivity
- Set the sensitivity of the PIR sensor to Low, Medium or High:
Low: The sensor’s detection distance is approximately 20 feet.
Medium: The sensor’s detection distance is approximately 30 feet.
High: The sensor’s detection distance is approximately 40 feet.
- Set the sensitivity of the PIR sensor to Low, Medium or High:
-
Setting Brightness
- Set the brightness of the light in standard operation.
- Brightness can be set to 0%, 15%, 30%, 50%, 100%.
Note1: When motion is detected the light will illuminate from established brightness to 100% brightness.
Note2: When the light is powered on, it will maintain 100% brightness for 15 seconds.
After 15 seconds, all lights will return to brightness level set.
-
Setting Group
- The fixtures can be divided and linked into four groups: A, B, C, and D. If one fixture in the group is triggered via motion, the other fixtures linked to the same group simultaneously turns on to 100% brightness.
- To operate your fixture separately from any group set the setting to “X”.
-
Linking Groups
To link fixtures: -
set the desired fixtures to the same Group (A, B, C or D) on the control panel.
-
Power on the desired fixtures.
-
Within 2 minutes of “power on” press the Web button on one fixture.
Note
* Fixtures will flash 3 times to indicate the fixtures are now linked.
* All the group linkable lights should set up at the same time.
FCC requirements
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
IC requirements
This device complies with CAN ICES-005B
Cet appareil est conforme à la norme canadienne NMB-005B.
This equipment complies with IC RSS-102 radiation exposure limits set forth
for an uncontrolled environment. This transmitter must be installed to provide
a separation distance of at least 20 cm 18 inches) from all persons and must
not be collocated or operating in conjunction with any other antenna or
transmitter.
This equipment complies with the FCC radiation exposure limits set possibility
of exceeding the FCC radio frequency exposure limits, human proximity to the
antenna shall not be less than 8 inches during normal operation.
Contains IC: 10798A-LINKABLE001
GE Lighting • 1-800-435-4448 •
www.gelighting.com
THE GE BRAND AND LOGO ARE TRADEMARKS OF THE GENERAL ELECTRIC COMPANY. ©2019 GE
LIGHTING.
INFORMATION PROVIDED IS SUBJECT TO CHANGE WITHOUT NOTICE. ALL VALUES ARE
DESIGN OR TYPICAL VALUES WHEN MEASURED UNDER LABORATORY CONDITIONS.
PK-00100497-2
Coach light
Contains IC: 10798A-LINKABLE001
STOP
BEFORE YOU BEGIN
Read these instructions completely and carefully. Before installing the light
fixture,ensure that all parts are present.
This product must be installed in accordance with the applicable installation
code by a person familiar with the construction and operation of the product
and the hazards involved.
Prepare Electrical Wiring
Electrical Requirements
The LED spotlight must be supplied with 120VAC 60Hz.
Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance
with National Electric Code(NEC) Article 600 and local codes.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>