WARNING
Read this manual completely and understand the machine before operating or servicing it.
- Read all instructions before installing or operating unit.
- Always wear appropriate personal protective equipment (PPE) when operating or servicing unit.
- Always follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Safety Data Sheet (SDS).
- If this unit is modified or serviced with parts not listed in this manual, the unit may not operate correctly.
- Never point the discharge wand at yourself, another person, or any object you do not want covered in chemical.
- Never leave unit unattended while pressurized.
- Always depressurize unit before attempting to remove the pump assembly.
- Always depressurize unit after use (as described in the After Use Instructions). Always store unit depressurized.
- Do not pressurize unit by any means other than the builtin pump assembly.
- Do not modify or remove pressure relief valve. Do not use unit if pressure relief valve is not operational.
- Always flush the unit with fresh water when switching from an alkaline to an acid or an acid to an alkaline.
- Always carry unit by the carrying handle. Never lift or carry the unit by the pump handle or the wand.
- Never use unit with hydrocarbons or flammable products.
- Do not exceed a fluid temperature of 100˚F (37˚C).
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine components, and hazardous
fluids in an environmentally safe way according to local waste disposal
regulations.
Always remember to recycle.
*Specifications and parts are subject to change without notice.
Liquid temperature range | 40-100˚F (4.4-37˚C) |
---|---|
Chemical compatibility | Chemical products used with this equipment must be |
formulated for this type of application and compatible with unit materials
and pump seals. For more information on chemical compatibility, consult the
manufacturer or SDS for your product or contact our customer service
department.
SPECIFICATIONS
Power type| Manual
Chemical pickup type| Draws from pre-mixed solution
Number of products unit can draw from| One product
Operating Capacity| 0.3 gallon (1.1 liter)
Discharge wand/tip type| Polypropylene trigger handle with 110 degree fan tip
Output distance| 1-2 ft (0.3-0.6 m)
Pump seals| Viton
Operation Instructions:
-
Ensure all air pressure is released from unit by activating the pressure release valve (located on the side of the pump assembly (PA-F1.5L)).
-
Securely hold the unit and unscrew the pump assembly (PA-F1.5L) from the tank in a counter-clockwise motion.
-
Follow all instructions from chemical manufacturer. Fill tank 3/4 of the way with pre-mixed solution. (Note: Do not overfill tank with solution.)
-
Securely hold the tank and screw the pump assembly (PAF1.5L) back on in a clockwise motion.
-
Pressurize the tank by pumping approximately 20 to 25 times, or until it become difficult to pump. (Note: The pressure relief valve will leak if the air pressure is too high.
Do not overfill tank with air.) -
To start foaming, point the wand assembly at the area you wish to foam and press down on the On/Off control to discharge foam. Release On/Off control to stop foaming.
-
For drain applications, position drain attachment over the drain or insert plug into drain. To start foaming, point the wand assembly at the area you wish to foam and press down on the On/Off control to discharge foam. Release On/Off control to stop foaming.
After Use Instructions:
- Release air pressure from unit after each use by activating the pressure release valve (located on the side of the pump assembly (PA-F1.5L)).
- It is recommended to always empty out remaining solution and run fresh water through the unit to rinse all parts thoroughly after each use and before storage.
Maintenance Instructions:
Warning: Always depressurize unit before performing maintenance.
To keep your unit operating properly, periodically perform the following
maintenance procedures:
-
Check the pump assembly for wear and leaks.
-
Check the suction tube and screen for debris and clean as needed.
-
Replace wadding (WD-F1.5L) inside discharge wand as needed. Replace wadding by following steps below:
1. Remove the discharge wand by unthreading retaining nut (WA-1.5L-RN).
2. Remove the wadding (WD-F1.5L) inside the discharge wand and discard.
3. Insert new wadding disks inside the discharge wand.
4. Thread the retaining nut back on. Make sure the o-ring (WA-1.5L-OR) is in place. -
Periodically lubricate the pump seal with a food safe lubricants. To lubricate the pump seal, raise pump handle and apply 5 to 10 drops of food safe lubricant between pump and pump sleeve. NEVER USE LUBRICANTS SUCH AS WD40.
PUMP ASSEMBLY
ITEM NUMBER: PA-F1.5L
WAND ASSEMBLY:
ITEM NUMBER: WA-F1.5L
TANKS
ITEM NUMBERS: TANK1.5L, TANK1.5LBK
FOR UNITS WITH DRAIN ATTACHMENTS:
ITEM NUMBER: WA-F1.5L-DP.75
ITEM NUMBER: WA-F1.5L-DP3.75
ITEM NUMBER | DESCRIPTION |
---|---|
DHB3814 | 3/8 FLAT SEAT 1/4 HOSE BARB |
H14C | 1/4in ID CLEAR POLYVINYL TUBING – Available per ft. (3/8 in OD) |
HB1414 | 1/4in MFT X 1/4in HOSE BARB |
HM1414 | HOSE MENDER -1/4 inch BARB X 1/4 inch BARB |
PA-F1.5L | PUMP ASSEMBLY FOR 1.5L FOAM UNIT |
PW-1.5L | POLY WAND FOR 1.5L PUMP UP |
RDC12 | RUBBER DRAIN CUP FOR 1/2 INCH BARB |
RMS2 | RUBBER MOLDED STOPPER-SIZE #2-EPDM |
STB-F1.5L | BUTTON SPRAY TIP FOR 1.5L PUMP UP |
TANK1.5L | 1.5L TANK-WHITE |
TANK1.5LBK | 1.5L TANK-BLACK |
WA-1.5L-OR | 0-RING FOR 1.5L WAND ASSEMBLY |
WA-1.5L-RN | RETAINING NUT FOR 1.5L WAND ASSEMBLY |
WD-F1.5L | WADDING DISK FOR 1.5L PUMP UP (1 PIECE) |