elc ALR3206D Programmable Power Supply
Product Information
Specifications
ALR3206D – Dual Programmable DC Power Supply
The ALR3206D is a dual-programmable DC power supply that provides a reliable
and efficient power source for various applications.
Technical Specifications
- Operating Modes: Double, Tracking, Series, Parallel
- Display: LCD
- Power Output: Dual Channels (1 & 2)
- Maximum Voltage Output: Depends on the operating mode
- Maximum Current Output: Depends on the operating mode
- Other Features: Various functionalities
Product Usage Instructions
Preliminary Information
Before using the ALR3206D, please read the user manual carefully and ensure
that you have a clear understanding of the device’s features and safety
precautions.
Description
-
Presentation
The ALR3206D is designed to provide a dual programmable DC power supply for your specific power requirements. -
Functional Designation of the Device
The ALR3206D has multiple operating modes, including Double, Tracking, Series, and Parallel, which allow you to customize the power output according to your needs. -
Safety Precautions
It is important to follow the safety precautions outlined in the user manual to ensure the safe operation of the ALR3206D. This includes proper grounding, avoiding exposure to water or moisture, and using appropriate protective equipment. -
Symbols and Definitions
The ALR3206D user manual provides a list of symbols and their definitions that are used throughout the device and its documentation. Familiarize yourself with these symbols to better understand the device’s functionality. -
Unpacking and Repackaging
When unpacking the ALR3206D, carefully remove all packaging materials and inspect the device for any signs of damage. If any damage is detected, contact the manufacturer or authorized service centre for assistance.
Operation
Technical Specifications
-
Channels 1 & 2 in Double or Tracking Mode
Both channels can be independently programmed in this mode to provide different voltage and current outputs. The tracking mode allows the channels to be linked together to provide synchronized output. -
Channels 1 & 2 in Series Mode
In series mode, the voltage outputs of both channels are combined to provide a higher total voltage output. The current output remains the same as the individual channels. -
Channels 1 & 2 in Parallel Mode
In parallel mode, the current outputs of both channels are combined to provide a higher total current output. The voltage output remains the same as the individual channels. -
Other Functionalities
The ALR3206D also offers various additional functionalities detailed in the user manual. These functionalities include but are not limited to overvoltage protection, overcurrent protection, and programmable presets. -
Other Features
The ALR3206D includes other features such as a built-in LCD for monitoring and adjusting the output parameters and a user-friendly interface for easy operation.
Overview
-
Front Panel
The front panel of the ALR3206D contains various controls and indicators to operate and monitor the device. These include the power switch, channel selection buttons, voltage/current adjustment knobs, and the LCD. -
Rear Panel
The rear panel of the ALR3206D includes input/output terminals, cooling vents, and power input connectors. Ensure proper connections and ventilation for safe and efficient operation. -
Brief Description of the Front Panel
-
Display
The ALR3206D features an LCD that provides real-time information about the power supply’s voltage, current, and other relevant parameters.
FAQ (Frequently Asked Questions)
-
Q: What are the different operating modes of the ALR3206D?
A: The ALR3206D has four operating modes: Double, Tracking, Series, and Parallel. These modes allow you to configure the power supply to suit your specific requirements best. -
Q: Can I combine the voltage outputs of both channels in the ALR3206D?
A: Yes, you can combine the voltage outputs of both channels in Series mode to achieve a higher total voltage output. -
Q: Can I combine the current outputs of both channels in the ALR3206D?
A: Yes, you can combine the current outputs of both channels in Parallel mode to achieve a higher total current output.
PREFACE
-
Manufacturer: ELC 59 Avenue des Romains 74000 ANNECY – FRANCE
Phone: +33 (0)4 50 57 30 46 -
Fax: +33 (0)4 50 57 45 19
-
Website: http://www.elc.fr – commercial@elc.fr
-
Item: DUAL DC STABILIZED PROGRAMMABLE POWER SUPPLY
-
Brand: elc
-
Type: ALR3206D
DESCRIPTION
PRESENTATION
You just bought a DUAL DC STABILIZED PROGRAMMABLE POWER SUPPLY type elc
ALR3206D. We thank you and congratulate you for your good choice. else’s
company is a specialist manufacturer that proposes a wide range of POWER
SUPPLIES and many other electronic test instruments: FUNCTION GENERATORS,
DECADE BOXES, and DIGITAL PANEL METERS. This item has been conceived according
to the European standard EN61010-1 and supplied in good condition. This
electrical instrument is intended for professionals, industrials and school
users. This instructions manual contains information and notes, which must be
respected by the purchaser, to ensure safe working and to maintain the
instrument in good condition.
FUNCTIONAL DESCRIPTION OF THE UNIT
This item is used in laboratories. It is designed with a large graphic
display, a sensitive keypad, and a compact vertical box with a handle and cord
storage integrated into the rear panel. This item will give you satisfaction
by offering many possibilities.
Fully programmable, this power supply can be controlled in several ways:
- via the front panel using the sensitive keypad
- via the isolated USB interface
- via the isolated RS485 interface
- via the isolated analogical interface (0 – 10V or the 10K potentiometer)
Each output of this DC power supply is regulated in a voltage of 0 to 32V and a current of 0 to 6A.
- “Parallel” “Series” and “Tracking” modes allow you to pair inside, the two channels of the power supply to obtain :
- Parallel: 0 to 32V and 0 to 12A
- Serial: 0 to 64V and 0 to 6A
- Tracking : ± 0 to 32V and 0 to 6A (mode coupled) or 2x 0 to 32V 0 to 6A (mode isolated with common adjustment)
- Several programmable functions U and I are accessible directly from the keypad and you will make positive or negative ramps, up or down time, or a square, or arbitrary wave.
- Automatic remote sensing can be enabled in mode 4 wires on the rear panel outputs.
- The outputs can be turned “ON” or “OFF” together or separately and there is a sleep mode with a “standby” touch.
All parameters are displayed on the graphic display.
SAFETY INSTRUCTIONS
Before any operation, read the following safety precautions to avoid injury and prevent damage to this product or another connection.
- To avoid all potential hazards, use this product only within the specified limits.
- Do not use the device without its cover. Do not use the item with its housing or any panels removed.
- Any intervention inside the casing, and particularly the fuse replacement, must imperatively be effected by skilled staff.
- The instrument must be used according to the instructions in this manual.
- Use it in a well-ventilated area. The air inlets and the fan outlet must be widely free, do not block them.
- Do not use it in wet conditions. Do not use in a wet environment to avoid electric shocks or short circuits inside the product.
- Do not use it in an explosive atmosphere. It is very important do not to operate the item near an explosive atmosphere, to prevent damage to the device or any personal injuries.
- The power cable is used as a cut system, the product must be connected to a 230V main source, easily accessible, with earth.
- When this unit must be powered via a separate autotransformer for a reduction of voltage, ensure that the common socket is connected to the grounding pole of the circuit of the supply.
- The common mode voltage between the ground and the output terminals must not exceed 100 VDC. In this case, a deemed dangerous voltage (> 60VDC) can be reached between one of the terminals and the earth. Therefore, it is imperative to use safety cables to connect the outputs of the device. Also, all connected devices must not have conductive parts accessible.
SAFETY TERMS AND SYMBOLS
You will find the following symbols on this equipment:
PACKAGING AND REPACKAGING
- Your power supply ALR3206D comes with a quick start guide and its power cable 2 poles + earth type “EUROPE”: CEE7 / 7 – IEC60320 C13.
- The complete user manual should be requested at commercial@elc.fr.
OPERATING
TECHNICAL FEATURES
The specifications below are given at least 30 minutes of use within the specified operating temperature range.
Channel 1 & 2 with separated or tracking mode
__
Mini maxi adjustment (Channel 1 & 2)
| Voltage| 0 to 32,00 Volts (0 to ±10mV)
---|---|---
Current| 0 to 6,000 Amps
OVP (over-voltage programming)| 0 to 32,20 Volts
OCP (over current programming)| 0 to 6,10 Amps
Adjustment accuracy (Channel 1 & 2)
± ( % output + offset)
| Voltage| 0.03% + 10 mV
Current| 0.03% + 2 mA
Regulation / Load 10 – 90%| Constant voltage| < 12 mV
Constant current| < 1 mA
__
Ripple (BP 20 MHz)
| Constant voltage| ≤ 0,7 mVRMS ; ≤ 4 mVp-p noise
≤ 15 mVp-p of commutation
Constant current| < 1 mA rms or 3 mA pp
Accuracy measurement (25°C ±5°C)
± ( % output + offset)
| Voltage| 0.03% .+ 10 mV
Current| 0.03% + 2 mA
Channel 1 & 2 with serial mode
Mini maxi adjustment | Voltage | 0 to 64,00 Volts (0 to ±20mV) |
---|---|---|
Current | 0 to 6,000 Amps | |
OVP (over-voltage programming) | 0 to 64,40 Volts | |
OCP (over current programming) | 0 to 6,10 Amps | |
Adjustment accuracy ± ( % output + offset) | Voltage | 0.03% + 20 mV |
Current | 0.03% + 2 mA | |
Regulation / Load 10 – 90% | Constant voltage | < 24 mV |
Constant current | < 2 mA |
__
Ripple (BP 20 MHz)
| Constant voltage| ≤ 1.5 mVRMS ; ≤ 10 mVp-p noise
≤ 30 mVp-p of commutation
Constant current| < 1 mA rms ou 3mA pp
Accuracy measurement (25°C ±5°C) ± ( % output + offset)| Voltage| 0.03% .+ 20
mV
Current| 0.03% + 2 mA
Channel 1 & 2 with parallel mode
Mini maxi adjustment | Voltage | 0 to 32,00 Volts (0 to ±10mV) |
---|---|---|
Current | 0 to 12,00 Amps | |
OVP (over-voltage programming) | 0 to 32,20 Volts | |
OCP (over current programming) | 0 to 12,20 Amps | |
Adjustment accuracy ± ( % output + offset) | Voltage | 0.03% + 10 mV |
Current | 0.08% + 10 mA | |
Regulation / Load 10 – 90% | Constant voltage | < 40 mV |
Constant current | < 2 mA | |
Ripple (BP 20 MHz) | Constant voltage | ≤ 0,7 mVRMS ; ≤ 4 mVp-p noise |
≤ 15 mVp-p of commutation
Constant current| < 1 mA rms ou 3mA pp
Accuracy measurement (25°C ±5°C) ± ( % output + offset)| Voltage| 0.03% .+ 10
mV
Current| 0.08% + 10 mA
Functions
Against short-circuits | By current regulation |
---|---|
Against over-temperature | By fan and thermal circuit breaker |
Against over-current on main source | By internal fuse (T4A ; 250V ; 5×20) |
Remote sensing | 4 wire mode, Disconnect scribe terminal blocks for 0,5mm² |
wires
Memory| Storage| 15 configurations
Recall| 15 + 1 (factory configuration)
Functions accessible by keypad| 6 available in Voltage or Current from 10 ms
to 50 min| Periodique SQUARE
Periodique or single shot RAMPE positive and negative ARBITRARY signal
Periodic or Multi-shot
Other characteristics
Alimentation (Entrée secteur) | 220 – 240 Volts ±10%, 50 – 60 Hz |
---|
EEC socket C14 for cable 2 poles + earth C13 (2P + E)
Maximum power consumption| 475W (2,1W in Standby mode)
Internal fuses (x2) AC input| 5 x 20 ; 250V T4A
Efficiency| > 81% of the maxi powerful
Safety| Class I, CAT II, degree of pollution 2
Complies with EN 61010-1, CAT II
CEM| Complies with EN 61326-1 & EN 55011
Voltage on the earth| ± 100 Vdc
Operating/Storage temperature| 0°C to + 40°C / -20°C to + 60°C
Humidity condition| < 85% to 30°C and decrease to 50% at 40°C
Altitude| < 2000 m
Db level of fan| < 48dB
Dimensions| 111 mm x 210 mm x 260 mm
Weight| 2.90 kg
OVERVIEW
FRONT PANEL
1 | LCD display | 2 | Keypad double function |
---|---|---|---|
3 | Channel selection | 4 | Functions key |
5 | Standby key | 6 | ON/OFF channel 2 |
7 | ON/OFF general | 8 | ON/OFF channel 1 |
9 | Safety socket output channel 1 | 10 | Earth socket |
11 | Safety socket output channel 2 | 12 | Keys + & – for adjustment |
REAR PANEL
13 | Handel | 14 | Sense connector channel 2 |
---|---|---|---|
15 | Powerful connector channel 2 | 16 | Sense connector channel 1 |
17 | Powerful connector channel 1 | 18 | RS485 connector |
19 | Analogical control connector | 20 | USB Connector |
21 | AC power inlet socket | 22 | Power AC switch |
23 | Earth safety socket Ø4mm | 24 | Cord storage |
SHORT DESCRIPTION OF THE FRONT PANEL
DISPLAY
The basic mode on the LCD (1) shows the value of the voltage and current
setting about two channels; the output’s powerful, the current regulation mode
(CV or CC) and the output’s state (ON or OFF). If the OVP and OCP stopped are
less than the maximum setting (32V and 6A) they will be displayed.
The measurement (voltage or current) is displayed instead of the set, if different. Simply touch on the V or A selection keys to display the operator instructions.
-
KEYPAD AND SHIFT
The keypad (2) allows directly modifying the set values U and I getting access to secondary functions. -
CHANNEL SELECTION
The keypad (3) allows choosing de channel to set. ‘’V’’ or ‘’A’’ selected indicates the channel you choose and you can set. -
KEYS CONTROL
The keys (4) allow the selection of the set to change and the selection of the dual-function keyboard with shift. -
STANDBY MODE
Combined with the function ‘’2nd’’ the keypad (5) allows to enable or disable standby mode (consumption < 2.5W). -
ON/OFF: CHANNEL 1 OR CHANNEL 2
The keypad (6) and (8) allow enable or disable channels 1 and 2. The keypad (7) allows enable or disable both channels. -
SLIDER AND ARROWS SETTING
Sliders and arrows (7) allow a direct change to the set value U and I or navigate through the secondary functions menu. -
SOUND SIGNAL
- Short signal low frequency: keypad detects [0] to [9].
- Short signal medium frequency: keypad detect function ([V], [A], [OK], …)
- Long signal high-frequency Input value error or safety defect.
-
SAFETY SOCKETS CHANNEL 1 & CHANNEL 2
The sockets (9 and 11) (safety sockets Ø4mm) allow the connection to the outputs + and – of channels 1 and channel 2 to the load. -
EARTH FUNCTIONAL SOCKETS
The sockets (10) (safety socket Ø4mm ) & socket (22) (safety and inversed socket Ø4mm ) allow a functional connection to the earth.
DESCRIPTION OF CONTROL COMMANDS
EXTERNAL REMOTE [0–10V] CONNECTION
This function allow the voltage or current setpoints for channels 1 and 2 via an analogical voltage, a potentiometer or resistance.
The maximum setpoint value is the one displayed before activating the
function
Follow sequence configuration:
EXTERNAL REMOTE ON/OFF
Connect GND and ON/OFF (relay contact, switch, sensor, ..) allowing control of isolated outputs with external signal.
Follow steps for modifying the configuration:
USB CONNECTION
Preparation of communication:
- Download on our website www.elc.fr the file: ALR32xx.inf Connect the power supply to the USB2.0 PC port with a USB cable as an A / B type USB (its length shouldn’t exceed 5 meters).
- Install the file.
- Your PC is ready to communicate with the ALR3206D.
- Use “Hyper Terminal ®” simple utility to communicate via the serial port, present on all PCs with Windows 95®, 98®, XP®, and Seven®.
- If you wish to control the power supply by LabVIEW® the drivers and executables are to be requested at commercial@elc.fr.
- This USB connection also allows you to update the “Firmware” via a utility (to request at commercial@elc.fr).
RS485 CONNECTION
Configure addresses of the power supplies.
MAINTENANCE
No particular maintenance is required for this instrument. Avoid dust, humidity, and shocks; your instrument will appreciate it. For the cleaning, please use a smooth duster.
TROUBLESHOOTING
If indicators do not light up on switching on, check:
- The connection to the main
- The replacement of the cord can be realized only with the model: 3G 0.75mm2; H05VV-F; CEE7/7 – IEC60320 C13
- The mains voltage
- When the ON/OFF switch is pressed
ERROR MESSAGE
If the following messages appear on the display, please contact the after-
sales service.
Message | Possible cause |
---|---|
“FAULT: FAILURE START-UP VOLTAGE” | Internal auxiliary power doesn’t work |
“TEMPERATURE SENSOR ERROR” | The internal temperature sensor doesn’t work |
“UNREGULATED CURRENT/VOLTAGE PROTECTION” | Internal stage power doesn’t |
work
“FAN OUT OF ORDER”| The fan doesn’t work
AFTER SALES SERVICE
The after-sales service is ensured by the elc company. During two years, spare parts and workmanship are guaranteed. This guarantee does not apply to instruments presenting defects or faults caused by improper use (wrong mains voltage, shocks …) or which have been repaired outside our factory or the repair shops of our authorized agencies.
DECLARATION OF CONFORMITY
- Manufacturer: elc
- Address: 59 avenue des Romains 74000 Annecy France
- Declares the product
- Name: DC POWER SUPPLY
- Type: ALR3206D
conformable to the requirements of the directives:
Low voltage 2014/35/UE, Electromagnetic Compatibility 2014/30/UE and RoHs 2017/2102/UE.
The following harmonized standards have been applied:
- Safety: EN 61010-1:2010 + A1:2019
- EMC: EN 61326-1:2021
Annecy September, 2021
H.CURRI, Manager
ELIMINATION OF MANUFACTURING WASTES BY THE PRIVATE USERS IN THE EU
- This symbol written on the product or in its packaging indicates that this product must not be thrown in the garbage with your other waste.
- It’s your responsibility to rid of your manufacturing waste by bringing it to a specialized sorting office for the recycling of electrical and electronic instruments.
- Collection and recycling of your waste will contribute to preserving natural resources and guarantee recycling respectful of the Environment and human health.
- For further information concerning the recycling centre near your place of residence, contact your town hall, the elimination service of garbage heap or the store where you bought the instrument.