nilfisk food AFS-1E-UPB Automated Filling Stations User Manual

June 4, 2024
nilfisk food

AFS-1E-UPB Automated Filling Stations
User Manual
MODEL NUMBER:
AFS-1E
AFS-1E-UP

Automated Filling Station

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

WARNING

nilfisk food AFS-1E-UPB Automated Filling Stations User -
icon

Read this manual completely and understand the machine before operating or servicing it.

  • Read all instructions before installing or operating the unit.
  • The unit is dedicated to the use of one product only. The product must be approved by an Ecolab application specialist.
  • Always wear appropriate personal protective equipment (PPE) when operating or servicing the unit.
  • Always follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Material Safety Data Sheet (MSDS).
  • Incoming air pressure cannot exceed 100 PSI (7 bar).
  • The unit will not operate properly if incoming air pressure is below 40 PSI (2.7 bar).
  • Do not exceed a fluid temperature of 100˚F (37˚C).
  • Air quality must be ISO 8573-1, class 4.4.2 compliant.
  • Do not use an air lubricator before the unit.
  • Do not use hydrocarbons, solvents, degassing, or flammable products.
  • When working with hazardous substances that may harm or irritate skin and/or eyes, make sure that emergency showers and eyewash stations are available in accordance with European standards EN 15154-1/2.
  • NOTICE: It is illegal to operate or service a unit in an EU member state if manual(s) is not written in that State’s language. Operators must read and understand the instruction manual before operating or servicing equipment. Please contact your equipment agent if the translation is needed.

PROTECT THE ENVIRONMENT

Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations.
Always remember to recycle.
*Specifications and parts are subject to change without notice.

Specifications:

Liquid Temperature …………. 40˚F to 100˚F (4.4˚C to 37˚C)
Priming Dry ……………….. 15 ft. (4.5 m)
Priming Wet………………… 20 ft. (6.1 m)
Flow Rate …………………… up to 5 GPM (18.9 L/min)
Air Supply Pressure ……… 20 to 100 PSI (1.4 to 6.9 bar)
Noise Level………………….. maximum 87 dB

Requirements:
Compressed Air Source Requirements: Compressed air 60 to 80 PSI (4 to 5.5 bar) with 2 CFM (56.7 l/min). The unit will not operate properly if incoming air pressure is below 40 PSI (2.7 bar).
Chemical Requirements: Follow all instructions from the chemical manufacturer and Material Safety Data Sheet (MSDS).
Dimensions and Weight:
Length ………………………………… 18.5 in (470 mm) approximately
Width …………………………………. 22 in (559 mm) approximately
Height ……………………………….. 46 in (1168 mm) approximately
Weight (AFS-1E) ………………………. 77 lbs (35 kg) approximately
Weight (AFS-1E-UPB) ………………… 80 lbs (37 kg) approximately
Maximum jug capacity (AFS-1E) ….. 6 gal (23 l) approximately
Maximum jug capacity (AFS-1E-UPB) … 2.4 gal (9 l) approximately

Air Operated Double Diaphragm Pump Models Offered:
P56: Polypropylene body with Santoprene diaphragm
P56V: Polypropylene body with Viton diaphragm
P56K: Polypropylene body with Kalrez diaphragm
*Kalrez pump is the standard pump. Santoprene and Viton are optional replacements.
Intended use of the machinery

  • Transfer liquid from Ecolab chemical supply (220l drum/IBC) to small cans (Ecolab cans <30Kg or Ecolab User-Packs G2/G3).
  • AFS-1E for filling of Ecolab cans <30Kg from the chemical supply.
  • AFS-1E-UPB for filling of Ecolab User-Pack G2/G3 from the chemical supply.
  • Only Ecolab products are allowed for filling with the exception of degassing- or flammable products.
  • Filling of empty mentioned packaging specific for the same product as stored in the chemical supply.

Notice: This system is designed to fill one type of chemical can / User- Pack consistently to a set level. It is not designed to fill multiple types of can / User-Pack or the same can / User-Pack to different levels.

INSTALLATION INSTRUCTIONS

Team lifting is required when lifting this unit.
Carefully plan the lift. Be conservative when estimating how much weight a team can handle.
All members must understand the lifting plan and how to complete their tasks safely.

  1.  Remove all parts from the shipping box.

  2. Select the desired area to mount the AFS-1E/AFS-1E-UPB. The AFS-1E/AFS-1E-UPB should be mounted on a vertical wall no more than 2 feet (61 cm) off the floor. It is possible to mount the system up to 30 feet (9 m) away from the chemical source but it is best to be as close as possible to ensure easy priming of the pump.
    Keep space around the unit clear – there should be at least 3.3 feet (1m) of space on the left and right sides, and 6.6 feet (2m) in front of the unit, as shown in the diagram.
    nilfisk food AFS-1E-UPB Automated Filling Stations User -
fig1

  3. There is a black plastic hose barb attached to one end of the suction line. From the back of the unit, pass this end of the suction line through one of the holes in the back of the unit. Clip the hose barb into the empty port on the P56/P56V/P56K pump.
    Slide the clip on the pump toward the suction line to secure the suction line. Run the open end of the suction line along one of the slots in the back of the AFS-1E and out to your chemical supply.

  4. Screw PW1246-SL into HV60. The PW1246-SL will sit in your chemical supply.

  5. Measure out enough suction lines to reach the chemical supply and cut to the required length. Cutting the suction line slightly longer than required is recommended as it will leave room to attach to the suction lance. NOTE: Keep all hoses off the ground and out of the walkway to avoid potential tripping hazards.

  6. Slide the SSC12 screw band onto the open end of the suction line and push the suction line onto the HBEL1212 hose barb.
    Secure by tightening the SSC12 screw band. Open the HV60 ball valve before operating the unit.

  7. Screw the AP25-E quick connector into the AF14 air filter on the left side of the unit.

  8. Mount the SHF1814 shelf; the AFS-1E/AFS-1E-UPB unit will sit on this shelf. Using a level, mark the (4) holes for mounting the shelf and drill using the included BIT38M 3/8 in. masonry bit. Insert the orange WMS516A wall anchors and secure the shelf using
    (4) WMS516X2 lag screws. Note: Use a 13 mm socket or wrench for lag screws.

  9. Set the AFS-1E/AFS-1E-UPB unit on the shelf and mark the (2) mounting holes that go through the back of the unit.

  10. Remove the AFS-1E/AFS-1E-UPB unit and drill the (2) marked holes with the BIT38M 3/8 in. masonry bit. Insert the orange WMS516A wall anchors.

  11.  Set the AFS-1E/AFS-1E-UPB unit back on the shelf and secure the unit to the wall using (2) WMS516X4 long lag screws and (2) FWLG516 washers. These go through the two holes in the AFS-1E/AFS-1E-UPB unit. Note: Use a 13 mm socket or wrench for lag screws.

  12. Align the L325-BRKT bracket with the two empty threaded inserts on top of the unit. Hold the bracket in place, and mark the location of the two mounting holes on the wall. Set the L325-BRKT bracket aside, then drill the mounting holes and insert orange WMS516A wall anchors.

  13. Attach the L325-BRKT bracket to the two empty threaded inserts on top of the AFS-1E/AFS-1E-UPB unit using (2) AS1 screws. This bracket will help secure the unit to the wall.

  14. Secure the L325-BRKT bracket using (2) WMS516X2 lag screws.
    Use this bracket to pull the unit flush against the wall.

SETUP INSTRUCTIONS FOR MODEL AFS-1E-UP

  1. Orient the USPK-UBRKT so the flange of the USPK-UBRKT is on the opposite side as the suction nipple on the User-Pack. Note:
    the suction nipple must be on the same side for all User-Packs intended to be filled. User-Packs with suction nipples matched up to the flange of the USPK- UBRKT will not fit and the system will not turn on.

  2. Connect compressed air to the AFS-1E-UPB.

  3. Set the System Pressure regulator (on the right) between 60-80 PSI (4.1 to 5.6 bar). Turn the dial below the gauge clockwise to increase pressure.

  4. Continue with “SETTING THE FILL LEVEL.”

SETUP INSTRUCTIONS FOR MODEL AFS-1E-UP

  1. Orient the USPK-UBRKT so the flange of the USPK-UBRKT is on the opposite side as the suction nipple on the User-Pack. Note: the suction nipple must be on the same side for all User-Packs intended to be filled. User-Packs with suction nipples matched up to the flange of the USPK-UBRKT will not fit and the system will not turn on.
  2. Connect compressed air to the AFS-1E-UPB.
  3. Set the System Pressure regulator (on the right) between 60-80 PSI (4.1 to 5.6 bar). Turn the dial below the gauge clockwise to increase pressure.
  4. Continue with “SETTING THE FILL LEVEL.”

SETTING THE FILL LEVEL

  1. Place the jerry can / User-pack in the AFS-1E/AFS-1E-UPB with the neck/cap next to the chemical hose.

  2. Note the appropriate fill height for the can / User-Pack.

  3. Loosen the CGRP14K cord grip and slide the bottom of the level sensor tube 1 inch (25mm) below the desired fill level. NOTE: The LST14 level sensing tube shuts off the system when it detects back pressure. The end of the tube must be submerged before generating back pressure.

  4. Retighten the CGRP14K cord grip with a wrench.

  5. Set the Level Sensing regulator (Left gauge) between 0.5 to 2 PSI. Turn the dial below the gauge counterclockwise to increase pressure.

  6. Test the system by filling the can / User-Pack with water.
    NOTE: The system will consistently fill the same can / User-Pack to this preset level.

  7. Perform a test with the chemical to ensure that the LST14 level sensing tube is calibrated correctly with the chemical.

OPERATION INSTRUCTIONS

Always wear the appropriate personal protective equipment (PPE) when operating the AFS-1E/AFS-1E-UPB.

  1. Use the handle to guide the fill tube into the can / User-Pack opening and place the designated can / User-Pack on to rack.
  2. Ensure that can / User-Pack is properly located on the rack. The can / User-Pack must push down on the whisker valve to activate the system.
  3. Close the door and secure the latch.
  4. Turn the black “Power” switch to the “ I ” position and the system will be ready to be activated.
  5. Press the green “Start” button to fill the can / User-Pack to the designated level. The system will shut off automatically at the designated fill level.
  6. The red “E-Stop” button can be used to shut off the system immediately if necessary.
  7. Turn the black “Power” switch to the “ O ” position.
  8. Open the door. Hold the handle of the fill tube while gently removing the can / User-Pack from the rack.
  9. Due to chemical residue left on the fill tube, avoid touching the fill tube.

NOTICE:

  • If the door is opened while the system is filling, the system will shut off.
  • The system will not turn on unless a can / User-Pack is properly positioned on the rack.
  • if a can / User-Pack is placed with a liquid level that is higher than the set fill level, the unit will not be activated when the “Start” button is pushed.
  • It is recommended to rinse the system thoroughly with water once a week.

REPLACE EMPTY CHEMICAL SUPPLY
Always wear the appropriate personal protective equipment (PPE) when operating the AFS-1E/AFS-1E-UPB.

  1. Make sure power is in the “ O “ position.
  2. Close the HV60 ball valve.
  3. Remove the suction lance from the empty chemical supply and place it in the full chemical supply. NOTICE: Avoid coming to contact with chemicals.
  4. Correctly position full chemical supply.
  5. Open the HV60 ball valve.

TO CHANGE CHEMICAL PRODUCT
Always wear the appropriate personal protective equipment when changing chemical products.
NOTE: It is not recommended to change the product. The machine is intended to be used with one product only. In case of the product, change follow the below instructions.

  1. Remove the suction lance from the chemical supply.
  2. Using a suitable can / User-Pack, rinse the system thoroughly with water.
  3. Place the suction lance in the new chemical drum.
  4. Cycle the system until any remaining water is flushed out and only the chosen chemical is dispensed.
  5. Verify the fill level is correct.

Maintenance

Always wear appropriate personal protective equipment (PPE) when servicing the unit. There may be chemicals in the system. Flush the system with sufficient water to clear out the remaining chemicals.
Practice proper Preventive Maintenance:

  • Rinse and clean the drip pan weekly.
  • Replace the H12B and H12CB hose every 6 months if the chemical being transferred contains one or more of the following ingredients:
    NaOH
    KOH
    H2O2
    HNO3
    H2SO4
    Acetic acid
    Peracetic acid
    Peroxyoctanoic acid
    Surfactants
    Please see the Product Data Sheet from your chemical supplier to identify ingredients in the product or ask your Ecolab application specialist.

TROUBLESHOOTING

Always wear appropriate personal protective equipment (PPE) when troubleshooting unit.

Unit does not begin fill process

  1. Check that the can / User-pack is placed firmly on top of the whisker valve. If they can / User-pack is not holding the whisker valve open the system will not run. If the valve has been bent it may need to be straightened by bending it back into place so that the can / User-pack can properly contact the whisker valve.
  2. Check the door. The system will not run if the door is not properly closed. There is a secondary air switch that needs to be contacted for proper operation of the unit.
  3. With the door closed, switch the filling station on. Undo the thumb screws on the control box to access the regulators. The gauge on the right should read 60 to 80 PSI (4.1  to 5.6 bar). If no pressure is indicated, turn the system off and proceed to No Pressure Detected, below. If the pressure is correct, skip to Pressure Detected.

No Pressure Detected

  1. Adjust the regulator below the gauge on the right.
  2. Check the Air In connections. Open the door and check the lines running to the door switch and from the door switch to the control box. This line is labeled “AIR IN” in the control box.
  3. Check your compressed air system.

Pressure Detected

  1. Check if the door switch can be depressed. It should move when pressed and spring back to its resting position when released.
  2. Make sure the door switch is fully depressed when the door is in the closed position. If the bracket is bent the switch may not contact the door and the bracket will have to be readjusted to contact the door when the door is in the closed position.
  3. With the system off, open the control box and verify that all the tubes are correctly and securely connected. Also, check the air connection behind the whisker valve and the air connection from the control box to the pump. Make sure air lines are not kinked.
  4. Verify that the LST14 level sensing tube is not plugged or creased. The PSI on the level sensor regulator (located in the control box) should be set to 0.5 to 2 PSI. If the regulator is set too low the system will not dispense chemicals.

Can / User-pack is not being filled completely

  1. Check the height of the LST14 level sensing tube.
  2. Check the chemical levels.

Can / User-pack is being overfilled

  1. Make sure the LST14 level sensing tube is inside the can / Userpack. If it is outside the can / User-pack it will not detect the level.
  2. Check the height of the LST14 level sensing tube. It should be about 1 in (2.5 cm) below the full line of the can / User-pack when the fill tube is in the can / User-pack.
  3.  Check the left gauge inside the control box. It should be set to 0.5 to 2 PSI. If it is set above 2 PSI the system will not shut off properly.

Air passes through the pump, but does not dispense chemical

  1. Verify that the HV60 ball valve, located at the top of the suction lance, is in the open position.
  2. The pump must be replaced.

To change pump
Always wear appropriate personal protective equipment (PPE) when changing the pump. There may be chemicals still in the system.

  1. Rinse the system thoroughly with water to clear out the remaining chemicals.
  2. Turn the system OFF.
  3. Disconnect the red air line from the pump.
  4. Disconnect the suction line from the pump.
  5. Undo the 3 screws along the bottom edge of the black plate.
  6. Carefully remove the plate by pulling the bottom edge out, then pulling down.
  7. Disconnect the chemical dispensing line from the pump.
  8. Remove the 4 screws holding the pump to the plate.
  9. Install replacement pump by following steps 3 to 8 in reverse.

nilfisk food AFS-1E-UPB Automated Filling Stations User -
fig2

nilfisk food AFS-1E-UPB Automated Filling Stations User -
fig3

nilfisk food AFS-1E-UPB Automated Filling Stations User -
fig4nilfisk food AFS-1E-UPB Automated
Filling Stations User - fig5

CONTROL BOX: FRONT COVER VIEW

nilfisk food AFS-1E-UPB Automated Filling Stations User -
fig6

CONTROL BOX: INSIDE VIEW

nilfisk food AFS-1E-UPB Automated Filling Stations User -
fig7

LATCH ASSEMBLY AIR BUTTON ASSEMBLY

nilfisk food AFS-1E-UPB Automated Filling Stations User -
fig8| nilfisk food AFS-1E-UPB Automated
Filling Stations User - fig10
AIR FILTER ASSEMBLY| DRIP PAN AND SHELF ASSEMBLY
nilfisk food AFS-1E-UPB Automated Filling Stations User -
fig9| nilfisk food AFS-1E-UPB Automated
Filling Stations User - fig11

SUCTION LINE ASSEMBLY

nilfisk food AFS-1E-UPB Automated Filling Stations User -
fig12

MOUNTING HARDWARE

.nilfisk food AFS-1E-UPB Automated Filling Stations User -
fig14

1. AF14 11. P56K
2. B4WV18 (1) + AIRBTNGRN assembly 12. Level Sensor Regulator
3. B4WV18 (2) + PV-TBNC-18 assembly 13. System Pressure Regulator
4. AFS-CTRL-BRD 14. Level Sensor Gauge
5. BSV18 (1) 15. System Pressure Gauge
6. PV-BNC-18-GR 16. PV-1
7. PV-BNC-18-RD 17. PV-2P
8. BSV18 (2) 18. Limit Valve
9. PV-WHKR-VLV 19. Level Sensor
10. Level Sensor Tube

nilfisk food AFS-1E-UPB Automated Filling Stations User -
fig15

ITEM NUMBER DESCRIPTION
AF-14 AIR FILTER – 1/4 FPT -25 MICRON FILTER
AFS-BODY BASE FOR AFS UNITS
AFS-CTRL-BRD CONTROL BOARD FOR AFS
AFS-DOORBELL BLUE DOOR FOR AFS UNITS
AFS-GRATE AFS DRIP PAN GRATE [REV 1]
AFS-PAN COLLECTION PAN FOR AFS UNITS
AFS-WINDOW 28×15 3/16 CLEAR PVC
AIRBTNGN AIR PUSH BUTTON GREEN
AP25-E AIR PLUG (EUR) – 1/4 MPT X PLUG
AS1 1/4-20 X 1/2 PHIL TRUSS M/S, S/S
B10321 10-32 X 1 PHIL TRUSS MACH SCR 18-8
B103225 10-32 X 1/4in PHIL MACH SCREW 18-8
B103234 10-32 X 3/4 PHIL TRUSS MACH SCR 18-8
B38162 HEX HEAD BOLT 3/8-16X2 18-8SS
B4WV18 BRASS 4-WAY VALVE 1/8 INCH PORTS
B8X58 8-15 X 5/8 inch PHIL FLAT TY-A 316 S.S.
BIT38M 3/8 X 6 MASONRY DRILL BIT
BSV18 BRASS SHUTTLE VALVE 1/8 INCH PORTS
CGRP14K CORD GRIP 1/4 INCH KYNAR
CV1438T-3 426-4MGB-F, 3 LB HASTELLOY
EC18 OETIKER CLAMP – 11.3
FB1187 FIBOX 11X7.5X7.1
FT-HNDL STAINLESS FILL TUBE HANDLE [REV 1]
FW14 1/4 X 5/8 OD FLAT WASHER 18-8 PLN
FW38X78 FLAT WASHER 3/8X7/8 X.050
FWLG14 .569 ID X 1.28 OD X .08 THICK FLAT WASHER SS 18-8
FWLG516 5/16” ID Stainless fender washer, 1.5” OD 18-8SS
FWP12 7/8 ID X 1.5 OD X 0.05 THK SSFW
FWP78 7/8in BY .137 BY 1 1/4in FLAT WASHER 18-8 PLN
H12B 1/2in BLUE PLIOVIC HOSE – Available per ft.
H12-BRKT AFS FILL HOSE BRACKET [REV 1]
H12CB 1/2 IN (ID) CLEAR BRAID RF SERIES – Available per ft.
H14B 1/4 in BLUE PLIOVIC HOSE – Available per ft.
H14KT 1/4 IN Kynar PVDF TUBING – Available per ft.
H14TU Translucent Green Polyurethane .25ODx.17ID – Available per ft.
HB1412 1/4in MPT X 1/2in HOSE BARB
HBBL103217 MINI HOSE BARB – 10-32X.17 EL
HBSS1212 STAINLESS HOSE BARB 1/2 X 1/2
HBSS14P STAINLESS STEEL HOSE BARB 1/4 INCH – FOR P56
HBSSEL1212 304 S.S. 1/2in MPT BY 1/2 in H.B. ELBOW
HV60 1/2in STAINLESS BALL VALVE – w/  WELDED NUT
L325-BRKT STAINLESS STEEL EL BRACKET WITH FOUR HOLES [REV 1]
LN14 1/4-20 NE NYL INS LOCKNUT 18-8 PLN
P56K 5700 PUMP WITH KALREZ SEALS – INCLUDES HOSE BARBS,

AIR FITTING, AND AIRPORT
PL-AFS| AFS Plate, ¼ in black PP
PV-1| PULSE VALVE #10-32 OPEN 3-WAY VALVE
PV-BNC-GR-18| PNEUMATIC PUSH-BUTTON – GREEN – 1/8 FPT- 3 PORT
NORMALLY CLOSED
PV-BNC-RD-18| PNEUMATIC PUSH-BUTTON – RED – 1/8 FPT- 3 PORT
NORMALLY CLOSED
PVC-DR-PIN-3/8| PVC DOOR PIN 3/8 DIAMETER X 1 9/16 INCHES LONG
PV-TBNC-18| PNEUMATIC TWIST SELECTOR BUTTON – 1/8 FPT- 3 PORT
NORMALLY CLOSED
PV-TBNC-18A| ADAPTER FOR CLIPPARD ACTUATOR
PV-WHKR-VLV| PNEUMATIC WHISKER VALVE – 1032 FEM PORT – BRASS –
AFS JUG SENSOR
PW1248-120| 1/2in  BLACK POLY PRO X 48in –  SCH.120 – 1/2in MPTOE &
1/4in FPTOE
PW12F| 1/2 INCH X 1/2 INCH POLYPRO SCHE 120 BLACK FPT X FPT
QF103214| MALE CONNECTOR #10-32 BY 1/4IN TUBE PUSH IN
QF14P| MALE CON. 1/4in TUBE X 1/4in MPT POLYPROPYLENE
QF18| MALE CON. 1/4in X 1/8in MPT BRASS
QF1814| MALE CONNECTOR 1/8in NPT BY 1/4in TUBE
POLYPROPYLENE
QFA1414K| 1/4in TUBE X 1/4in HOSE STEM – KYNAR
QFEL1814| FIXED ELBOW 1/8in MPT X 1/4in TUBE – POLYPROPYLENE
QFU14| UNION CON. 1/4in TUBE – POLYPROPYLENE
S1034FHL| 10 X 3/4 PHIL FLAT HI-LO THIRD SCREW 18-8
S142034| 1/4-20 X 3/4 PHIL TRUSS M/S 18-8
SEL12F| S.S. ELBOW 1/2in FPT X 1/2in FPT
SHF1814| Shelf 18 X 14 inch for Wall mounting AFS-1E [REV 1]
SS1B2WV-BRKT| BRACKET FOR TWO-WAY BRASS AIR VALVE [REV 1]
SSA14| SS304 MALE/FEMALE ADAPTOR 1/4 MPT X 1/4 NPT
SSC12| WORM GEAR CLAMP, S/S (.31-.91)
SSE12| STREET ELBOW 1/2in – 316 S.S.
SSK2H| STAINLESS STEEL KEEPER – 2-HOLE MOUNTING
SSL2.25| STAINLESS STEEL LATCH – 2.25in DRAW – ELECTROPOLISHED – PADLOCKING
TLCLAMP12| Tefzel Loop Clamp for 1/2” Outside Diameter
USPK-BRC| BRACE FOR USER PACK AFS-1-E [REV 1]
USPK-SHF| UserPack Shelf for AFS-1E [REV 1]
USPK-UBRKT| U-BRACKET FOR USER PACK AFS-1-E [REV 1]
WMS516A| concrete wall anchor, 3/8 in. drill size for 5/16 in. screws, 2.5 in. long
WMS516X2| 5/16 X 2 IN stainless lag bolt, w/hex head 18-8SS
WMS516X4| WALL MOUNT SCREWS 5/16 X 4

Ecolab United Kingdom
David Murray John Building
Swindon, Wiltshire
SN1 1NH
Telephone: 44 1793 51 12 21
Fax: 44 1793 61 85 52

Ecolab Germany
Ecolab Deutschland GmbH
Ecolab-Allee 1
40789 Monheim am Rhein
Telephone: 49 2 173 599 0

Ecolab Austria
Erdbergstrasse 29
1030 Wien
Telephone: 43 1 715 25 50
Fax: 43 1 715 25 50 2850

Ecolab Denmark
Carl Jacobsens Vej 29-37
2500 Valby
Telephone: 45 36 15 85 85
Fax: 45 36 15 84 48

EC DECLARATION OF CONFORMITY

Company Name and Address:
FOAM-iT 3833 Soundtech Ct. SE Grand Rapids, Michigan 49512 US
Name and Address of the company authorized to compile the Technical File:
ACC – Services Contact 105 route des pommiers Centre Ubidoca 74370 St. Martin Bellevue France
Company name declares under sole responsibility that the product described as:
Equipment Name:
Automated Filling System
Equipment Description:
Automated Filling System
Model Number:
AFS-1E, AFS-1E-UP
Complies with the requirements of the following European Directives:
Machinery Directive 2006/42/EC;
Main Standards Considered:
EN ISO 12100:2010, EN ISO 4414:2010

19 February 2019 Location:

FOAM-IT 3833 Soundtech Ct. SE Grand Rapids, Michigan 49512 US
Authorized Representative:
Dan Jacques| President:
| REV1

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals