GE Lighting VAN3LDMBNMT Mentor 3-Light Vanity Light Installation Guide

June 13, 2024
GE Lighting

GE Lighting VAN3LDMBNMT Mentor 3-Light Vanity Light Installation Guide
GE Lighting VAN3LDMBNMT Mentor 3-Light Vanity Light

www.gelighting.com
The GE brand and logo are trademarks of the General Electric Company. 2022
GE Lighting, a Savant company. Information providedis subject to change without notice. Al values are design or typical values when measured under laboratory conditions

TOOLS REQUIRED

  • Phillips-Head Screwdriver

  • Ladder

  • Electrical Tape

  • Wire Stripper

  • Wire Cutter

  • Safety Goggles

  • Hammer

  • Pencil
    Tools Required

  • Drill with 5/16 Drill Bit

INSTALLATION

Remove the fixture and the mounting package from the box and make sure that no parts are missing by referencing the illustrations on the installation instructions.


caution: Tum of the main power at the circuit breaker before installing the fixture. Failure to disconnect power supply prior to installation may result in possible shock or death.

  1. Remove existing fixture and disconnect all electrical wiring

  2. Remove mounting bracket[10] from fixture canopy[14] by removing canopy screws[11].

  3. Mark two hole locations on the wall that align with hole distance in mounting bracket[10]. Drill two holes with 5/16” size dril bit at the marked locations. Insert drywall anchors[9)] into each drilled mounting hole.
    Installations Instructions

  4. Place mounting bracket(10] onto outlet box(1], fix mounting bracket(10] tightly by using two mounting bracket screws[12]. Insert self-tapping screws[13] into drywall anchors{9] to ensure that mounting bracket[10] s tight against the wall.
    Installations Instructions

  5. Connect black supply wire[2] to black fixture wire[7] and connect white supply ‘wire[3] to white fixture wire[8] by using P4 wire nuts[5]. Connect ground fixture wire[6] at the top of the fixture metal body[14] to power supply ground wire[4] from outlet box(1]. Wrap P4 wire nuts(s] with electrical tape for a more secure connection. Carefully tuck wires back into the outlet box[1]. Do not get wires pinched between the wall and canopy.

  6. Attach fixture canopy[14] onto mounting bracket[10] by canopy screws[11] previously removed in step 2. Tighten to secure fixture to the wall. Note: Fixture can be mounted in the up or down position.

PRODUCT COVERED

Model Input voltage (Vac, H2)
VAN3LDVBNMT 120,60

LIGHT SOURCE

Recommended Maximum Socket
Bulb Bulb Wattage Type
AI9(Not Included) 60w E26

Stop Icon
BEFORE YOU BEGIN

Read these instructions completely and carefully.

WARNING

  • Risk of fire or electric shock: Wall light installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
  • Consult a qualified electrician to ensure ensure correct connection to branch circuit. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
  • ‘These products are intended to be used in dry or damp locations.
  • Min 90°C (194°F) supply conductors suitable for operation in an ambient not exceeding 40°C (104°F).

REPARE ELECTRICAL WIRING


Electrical Requirements

The fixture must be supplied with 120VAC 60Hz.


Grounding Instructions

The grounding and bonding of the overall system shall b in accordance with National Electric Code(NEC) and loca

PACKAGE CONTENTS

Product Overawe

  1. OULET BOX (NOT INCLUDED)
  2. BLACK SUPPLY WIRE (NOT INCLUDED)
  3. WHITE SUPPLY WIRE (NOT INCLUDED)
  4. POWER SUPPLY GROUND WIRE (NOT INCLUDED)
  5. P4 WIRE NUT x 3
  6. GROUND FIXTURE WIRE
  7. BLACK FIXTURE WIRE
  8. WHITE FIXTURE WIRE
  9. DRYWALL ANCHOR x 2
  10. MOUNTING BRACKET
  11. CANOPY SCREW x 4
  12. MOUNTING BRACKET SCREW x 2
  13. SELF-TAPPING SCREW x 2
  14. FIXTURE CANOPY
  15. BULB x 3 (NOT INCLUDED)
  16. GLASS SHADE SCREW x 9
  17. GLASS SHADE x 3

WARRANTY

If this fixture does not last for 5 years (based on 3 hours per day / 7 days per week) return fixture, proof of purchase and your name and address to GE Lighting, a Savant company, Product Service Dept., 1975 Noble Road, Cleveland, OH 44112 for a replacement. FIXTURE REPLACEMENT IS SAVANT TECHNOLOGY LLC’S SOLE WARRANTY OBLIGATION. INCIDENTAL AND CONSEQUENTIAL DAMAGES ARE EXCLUDED. This warranty does not cover the cost of installation, removal or reinstallation, or damage resulting from misuse, abuse, or damage from improper wiring or installation. You are solely responsible for (and Savant Technology LLC disclaims) any and all loss, liability, or damages, including to Your wiring, electricity, home, product, product peripherals, computer, mobile device, and all other items and pets in your home, resulting from your use of the product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from location to location.

GE Lighting, a Savant company 1-800-435-4448www.gelighting.com
GEIS ATRADEMARK OF GENERAL ELEGTRIC COMPAY, USED UNDER TRADEMARK LICENSE. 2022 GE LIGHTING, A SAVANT COMPANY

INFORMATION PROVIDED IS SUBJEGT T0 CHANGE WITHOUT NOTICE. ALL VALUES ARE DESIGN OR TYPICAL VALUES WHEN MEASURED UNDER LABORATORY CONDITIONS.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

GE Lighting User Manuals

Related Manuals