V-TAC VT61003 LED Backlit Recessed Panel Instruction Manual
- June 13, 2024
- V TAC
Table of Contents
INSTRUCTION MANUAL
LED BACKLIT RECESSED PANEL
WEEE Number: 80133970
TECHNICAL DATA
‘This product contains a light source of energy efficiency class <F/E>’, where <F/E> shall be replaced by the energy efficiency class of the contained light source.
INTRODUCTION & WARRANTY
Thank you for selecting and buying V-TAC product. V-TAC will serve you the best. Please read these instructions carefully before starting the installation and keep this manual handy for future reference. If you have any another query, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at the best. The warranty is valid for 2 years from the date of purchase. The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no warranty against damage to any surface due to incorrect removal and installation of the product. The products are suitable for 10-12 Hours Daily operation. Usage of product for 24 Hours a day would void the warranty. This product is warranted for manufacturing defects only.
WARNING
- Please make sure to turn off the power before starting the installation.
- Installation must be performed by a certified person.
- The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire should be replaced.
- For Indoor use only
- If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
- Method of attachment of the cable or cord such that any replacement can only be made by the manufacturer, his service agent or similar qualifed person.
This marking indicates that this product should not be disposed of with other
household wastes.
Caution, risk of electric shock.
http://vtac.store/vt-61003
MULTI-LANGUAGE
MANUAL QR CODE
Please scan the QR code to access the manual in multiple languages.
ATTENTION! Do not look directly at LED light beam. Product can only be supplied by rated voltage or voltage within the range provided. It’s forbidden to use the product with damaged protective cover. Product must not be used in unfavorable conditions, e.g. dust, water, moisture, vibrations, explosive air atmosphere, fumes, or chemical fumes, etc. In the area of strong electromagnetic interference, the functioning of the product may be disrupted.
USAGE GUIDELINES/MAINTENANCE
Any maintenance work must be performed when the power supply is cut off and the product has cooled down. Clean only with so and dry cloths. Do not use chemical detergents. Do not cover the product. Ensure free air access. Product may heat up to a higher temperature.
MOUNTING
Read the manual before mounting. Mounting should be performed by a qualified electrician. Exercise caution. Product has a protective contact /terminal. Failure to connect the protective lead may lead to electric shock. Mounting diagram: see pictures. Check for proper mechanical fastening and connection to electrical power prior to first use.
RECESSED PANEL INSTALLATION DIAGRAM
- Cut a hole using an appropriate tool according to the cut-out size.
ROUND PANEL | 3W | 6W | 12W | 18W | 24W |
---|
INSTALLATION
HOLE SIZE| Φ8o
(77-82mm)| Φ110
(107-112mm)| Φ155
(150-155mm)| Φ205
(200-205mm)| Φ280
(275-280mm)
2. Switch OFF the power & Connect
AC: 220-240V voltage with terminals.
-
Hold the two clips back against the panel light and push it into the hole. Allow the springs to pull the light up to the ceiling.
-
Check whether the lamp is flat and electrified.
-
Clean the lamp with clean cloth.
-
Switch on the power and test the light.
-
Cut a hole using an appropriate tool according to the cut-out size.
D PANEL| 3W| 6W| 12W| 18W| 24W
---|---|---|---|---|---
INSTALLATION
HOLE SIZE| Φ8o
(77-82mm)| Φ110
(107-112mm)| Φ155
(150-155mm)| Φ205
(200-205mm)| Φ280
(275-280mm) -
Switch OFF the power & Connect
AC: 220-240V voltage with terminals.` -
Hold the two clips back against the panel light and push it into the hole. Allow the springs to pull the light up to the ceiling.
-
Check whether the lamp is flat and electrified.
-
Clean the lamp with clean cloth.
-
Switch on the power and test the light.
DISASSEMBLY DIAGRAM
-
Power o§, tap the central area of the diffusion plate with a pointed tool, and take out the cracked diffusion plate
-
Remove the power wire from the plug terminal
-
If there is no hot melt column in the lamp body or the hot melt column is not hot melt, this step will be adjusted without treatment. If the hot-melt column has been fused to fix the aluminum substrate, cut the hot-melt part of the hot-melt point with diagonal pliers.
-
Press the buckle outwards, remove the aluminum substrate pressing strip from the bayonet, and remove the pressing strip. This step is only required for 24W panel light, other items are not required.
-
Press the buckle outwards, remove the aluminum substrate from the buckle, and remove the light source board.
-
Take out two-cord cable (wire diameter 18-22AWG) and insert it into the plug-in terminal. Connect the external power supply for testing.
IN CASE OF ANY QUERY/ISSUE WITH THE PRODUCT, PLEASE REACH OUT TO US AT:
SUPPORT@V-TAC.EU
FOR MORE PRODUCTS RANGE, INQUIRY PLEASE CONTACT OUR DISTRIBUTOR OR NEAREST
DEALERS. V-TAC
EUROPE LTD. BULGARIA, PLOVDIV 4000, BUL.L.KARAVELOW 9B
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>