inELS RFUS-61 Switch Unit Instruction Manual

June 4, 2024
inELS

inELS RFUS-61 Switch Unit

inELS-RFUS-61-Switch-Unit

Characteristics

  • The switching unit with 1 output channel is used for controlling appliances, sockets or lights.
  • They can be combined with detectors, controllers, iNELS RF Control or system components.
  • The increased IP65 protection is suited to mounting on the wall or in harsh environments such as the cellar, garage or bathrooms.
  • It enables connection of the switched load up to 12 A (3.000 W).
  • Multi-function design – button, impulse relay and time function of delayed ON or OFF with time setting of 2s-60 min.
  • The switching unit may be controlled by up to 25 channels (1 channel represents 1 button on the controller).
  • The programming button on the unit is also used for manual control of the output.
  • Memory status can be pre-set in the event of a power failure.
  • For components labelled as iNELS RF Control2 (RFIO2), it is possible to set the repeater function via the RFAF/USB service device.
  • Range up to 200 m (in open space), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO2 that support this feature.
  • Communication frequency with bidirectional protocol iNELS RF Control2 (RFIO2).

Assembly

mounting in harsh environmentsinELS-RFUS-61-Switch-
Unit-1

Connection

inELS-RFUS-61-Switch-Unit-2

Radio frequency signal penetration through various construction materials inELS-RFUS-61-Switch-Unit-3

For more information, see “Installation manual iNELS RF Control”: http://www.elkoep.com/catalogs-and-brochures

Indication

inELS-RFUS-61-Switch-Unit-4

Before starting the programming / manual control, open the actuator housing using a screwdriver. After completing programming / manual control, snap the housing closed again.

  • LED STATUS – indication of the device status. Indicators of memory function:
    On – LED blinks x 3.
    Off – The LED lights up once for a long time.

  • Manual control is performed by pressing the PROG button for less than 1s.

  • Programming is performed by pressing the PROG button for more than 1s.
    In the programming and operating mode, the LED on the component lights up at the same time each time the button is pressed – this indicates the incoming command. inELS-RFUS-61-Switch-Unit-5

Compatibility

The device can be combined with all system components, controls and devices of iNELS RF Control and iNELS RF Control2.
The detector can be assigned an iNELS RF Control2 (RFIO2) communication protocol.

Functions and programming with RF transmitters

Function button

Description of button

The output contact will be closed by pressing the button and opened by releasing the button.
For the correct execution of individual commands (press = closing / releasing the button = opening), the time delay between these commands must be a min of . 1s (press – delay 1s – release).

Programming

inELS-RFUS-61-Switch-Unit-10

Function switch on

Description of switch on

The output contact will be closed by pressing the button.

ProgramminginELS-RFUS-61-Switch-Unit-10

Function switch off

Description of switch off

The output contact will be opened by pressing the button.

ProgramminginELS-RFUS-61-Switch-Unit-12

Function impulse relay

Description of impulse relay

The output contact will be switched to the opposite position by each press of the button. If the contact was closed, it will be opened and vice versa.

ProgramminginELS-RFUS-61-Switch-Unit-14

Funcion delayed off

Description of delayed off

The output contact will be closed by pressing the button and opened after the set time interval has elapsed.

ProgramminginELS-RFUS-61-Switch-Unit-14 inELS-RFUS-61
-Switch-Unit-15

Function delayed on

Description of delayed on

The output contact will be opened by pressing the button and closed after the set time interval has elapsed.

ProgramminginELS-RFUS-61-Switch-Unit-14 inELS-RFUS-61
-Switch-Unit-15

Safe handling

When handling a device unboxed it is important to avoid contact with liquids. Avoid contact with the components of the device.

Programming with RF control units

The address listed on the side of the actuator is used for programming and controlling actuators by RF control units.

Delete actuator

Deleting one position of the transmitter

By pressing the programming button on the actuator for 5 sec-onds, deletion of one transmitter activates. LED fl ashs 4x in each 1s interval.
Pressing the required button on the transmitter deletes it from the actuator’s memory.
To confirm deletion, the LED will confi rm with a fl ash long and the component returns to the operating mode. The memory status is not indicated.
Deletion does not aff ect the pre-set memory function.

Selecting the memory function

inELS-RFUS-61-Switch-Unit-20

Memory function on:

  • For functions 1-4, these are used to store the last state of the relay output before the supply voltage drops, the change of state of the output to the memory is recorded 15 seconds after the change.
  • For functions 5-6, the target state of the relay is immediately entered into the memory after the delay, after re-connecting the power, the relay is set to the target state.

Memory function off:
When the power supply is reconnected, the relay remains off.

Technical parameters

Supply voltage: 230 V AC / 50 – 60 Hz 120 V AC / 60Hz 12-24 V AC/DC 50-60Hz
Apparent power: 5 VA / cos φ = 0.1 5 VA / cos φ = 0.1
Dissipated power: 0.6 W 0.6 W 0.7 W
Supply voltage tolerance: +10 %; -15 %
Output
Number of contacts: 1 x switching
Rated current: 12 A / AC1
Switching power: 3000 VA / AC1, 384 W / DC
Peak current: 30 A / <3 s
Switching voltage: 250 V AC1 / 24 V DC
Min. switching power DC: 500 mW
Mechanical service life: 3×107
Electrical service life (AC1): 0.7×105
Control
RF command from the transmitter: 866 MHz, 868 MHz, 916 MHz
Manual control: button /  PROG (ON/OFF)
Range in open space: up to
Other data
Operating temperature: -15 … + 50 °C
Operating position: any
Mounting: screws
Protection: IP65
Overvoltage category: III.
Contamination degree: 2
Cross-section of connecting wires (mm2): max.1×2.5,max. 2×1.5
Recommended power cord: CYKY 3×1.5 (CYKY 4×1.5)
Dimensions: 136 x 62 x 34 mm
Weight: 146 g
Related standards: EN 60669, EN 300220, EN 301489 R&TTE Directive, Order. No

426/2000 Coll. (Directive 1999/EC)

Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s.

Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Instal-lation and connection can be carried out only by a person with adequate professional qualifi cation upon under-standing this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regula-tions, norms, directives and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an obstruction, inter-fered, battery of the transceiver can get fl at etc. and thus disable remote control.