inELS RFUS-61 Switch Unit Instruction Manual
- June 4, 2024
- inELS
Table of Contents
inELS RFUS-61 Switch Unit
Characteristics
- The switching unit with 1 output channel is used for controlling appliances, sockets or lights.
- They can be combined with detectors, controllers, iNELS RF Control or system components.
- The increased IP65 protection is suited to mounting on the wall or in harsh environments such as the cellar, garage or bathrooms.
- It enables connection of the switched load up to 12 A (3.000 W).
- Multi-function design – button, impulse relay and time function of delayed ON or OFF with time setting of 2s-60 min.
- The switching unit may be controlled by up to 25 channels (1 channel represents 1 button on the controller).
- The programming button on the unit is also used for manual control of the output.
- Memory status can be pre-set in the event of a power failure.
- For components labelled as iNELS RF Control2 (RFIO2), it is possible to set the repeater function via the RFAF/USB service device.
- Range up to 200 m (in open space), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO2 that support this feature.
- Communication frequency with bidirectional protocol iNELS RF Control2 (RFIO2).
Assembly
mounting in harsh environments
Connection
Radio frequency signal penetration through various construction materials
For more information, see “Installation manual iNELS RF Control”: http://www.elkoep.com/catalogs-and-brochures
Indication
Before starting the programming / manual control, open the actuator housing using a screwdriver. After completing programming / manual control, snap the housing closed again.
-
LED STATUS – indication of the device status. Indicators of memory function:
On – LED blinks x 3.
Off – The LED lights up once for a long time. -
Manual control is performed by pressing the PROG button for less than 1s.
-
Programming is performed by pressing the PROG button for more than 1s.
In the programming and operating mode, the LED on the component lights up at the same time each time the button is pressed – this indicates the incoming command.
Compatibility
The device can be combined with all system components, controls and devices of
iNELS RF Control and iNELS RF Control2.
The detector can be assigned an iNELS RF Control2 (RFIO2) communication
protocol.
Functions and programming with RF transmitters
Function button
Description of button
The output contact will be closed by pressing the button and opened by
releasing the button.
For the correct execution of individual commands (press = closing / releasing
the button = opening), the time delay between these commands must be a min of
. 1s (press – delay 1s – release).
Programming
Function switch on
Description of switch on
The output contact will be closed by pressing the button.
Programming
Function switch off
Description of switch off
The output contact will be opened by pressing the button.
Programming
Function impulse relay
Description of impulse relay
The output contact will be switched to the opposite position by each press of the button. If the contact was closed, it will be opened and vice versa.
Programming
Funcion delayed off
Description of delayed off
The output contact will be closed by pressing the button and opened after the set time interval has elapsed.
Programming
Function delayed on
Description of delayed on
The output contact will be opened by pressing the button and closed after the set time interval has elapsed.
Programming
Safe handling
When handling a device unboxed it is important to avoid contact with liquids. Avoid contact with the components of the device.
Programming with RF control units
The address listed on the side of the actuator is used for programming and controlling actuators by RF control units.
Delete actuator
Deleting one position of the transmitter
By pressing the programming button on the actuator for 5 sec-onds, deletion of
one transmitter activates. LED fl ashs 4x in each 1s interval.
Pressing the required button on the transmitter deletes it from the actuator’s
memory.
To confirm deletion, the LED will confi rm with a fl ash long and the component
returns to the operating mode. The memory status is not indicated.
Deletion does not aff ect the pre-set memory function.
Selecting the memory function
Memory function on:
- For functions 1-4, these are used to store the last state of the relay output before the supply voltage drops, the change of state of the output to the memory is recorded 15 seconds after the change.
- For functions 5-6, the target state of the relay is immediately entered into the memory after the delay, after re-connecting the power, the relay is set to the target state.
Memory function off:
When the power supply is reconnected, the relay remains off.
Technical parameters
Supply voltage: | 230 V AC / 50 – 60 Hz | 120 V AC / 60Hz | 12-24 V AC/DC 50-60Hz |
---|---|---|---|
Apparent power: | 5 VA / cos φ = 0.1 | 5 VA / cos φ = 0.1 | – |
Dissipated power: | 0.6 W | 0.6 W | 0.7 W |
Supply voltage tolerance: | +10 %; -15 % | ||
Output | |||
Number of contacts: | 1 x switching | ||
Rated current: | 12 A / AC1 | ||
Switching power: | 3000 VA / AC1, 384 W / DC | ||
Peak current: | 30 A / <3 s | ||
Switching voltage: | 250 V AC1 / 24 V DC | ||
Min. switching power DC: | 500 mW | ||
Mechanical service life: | 3×107 | ||
Electrical service life (AC1): | 0.7×105 | ||
Control | |||
RF command from the transmitter: | 866 MHz, 868 MHz, 916 MHz | ||
Manual control: | button / PROG (ON/OFF) | ||
Range in open space: | up to | ||
Other data | |||
Operating temperature: | -15 … + 50 °C | ||
Operating position: | any | ||
Mounting: | screws | ||
Protection: | IP65 | ||
Overvoltage category: | III. | ||
Contamination degree: | 2 | ||
Cross-section of connecting wires (mm2): | max.1×2.5,max. 2×1.5 | ||
Recommended power cord: | CYKY 3×1.5 (CYKY 4×1.5) | ||
Dimensions: | 136 x 62 x 34 mm | ||
Weight: | 146 g | ||
Related standards: | EN 60669, EN 300220, EN 301489 R&TTE Directive, Order. No |
426/2000 Coll. (Directive 1999/EC)
Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1
cm between each units.
Between the individual commands must be an interval of at least 1s.
Warning
Instruction manual is designated for mounting and also for user of the
device. It is always a part of its packing. Instal-lation and connection can
be carried out only by a person with adequate professional qualifi cation upon
under-standing this instruction manual and functions of the device, and while
observing all valid regulations. Trouble-free function of the device also
depends on transportation, storing and handling. In case you notice any sign
of damage, deformation, malfunction or missing part, do not install this
device and return it to its seller. It is necessary to treat this product and
its parts as electronic waste after its lifetime is terminated. Before
starting installation, make sure that all wires, connected parts or terminals
are de-energized. While mounting and servicing observe safety regula-tions,
norms, directives and professional, and export regulations for working with
electrical devices. Do not touch parts of the device that are energized – life
threat. Due to transmissivity of RF signal, observe correct location of RF
components in a building where the installation is taking place. RF Control is
designated only for mounting in interiors. Devices are not designated for
installation into exteriors and humid spaces. The must not be installed into
metal switchboards and into plastic switchboards with metal door –
transmissivity of RF signal is then impossible. RF Control is not recommended
for pulleys etc. – radiofrequency signal can be shielded by an obstruction,
inter-fered, battery of the transceiver can get fl at etc. and thus disable
remote control.