profi-pumpe DPY01114-4 Diesel Barrel Pump Instruction Manual

October 31, 2023
profi-Pumpe

profi-pumpe DPY01114-4 Diesel Barrel Pump Instruction Manual

profi-pumpe DPY01114-4 Diesel Barrel Pump Instruction
Manual

*AdBlue®, a registered trademark of
Technical changes, misprints and mistakes reserved! Newest information about our products can be found online. :
http://www.profi-pumpe.de

SAFETY INSTRUCTION AND WARNINGS

profi-pumpe DPY01114-4 Diesel Barrel Pump Instruction Manual - SAFETY
INSTRUCTION AND WARNINGS

1. INTRODUCTION

We would like to congratulate you on the purchase of our pump. We appreciate your trust. That`s why functional security and operational safety stands on first place for us.
To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the pump. Failure to follow the instructions and safety precautions can result in injury or property damage. Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them.

2. IN GENERAL

The barrel pumps are developed according to the newest stand of technology, manufactured with much care and go under strict intensive controls ­ each pump is checked individually ­ rests of the check-fluid could be still inside the pump or on the package. The counter (if available) shows more than 0,0 Liter because of that (usually 5-12L). The pumps were optimized by us in particular for their special demands. Make sure after unpacking the pump that the data given on the type label agree with the operating conditions. In the case of doubt the pump is not to be used. Transport damages are immediately to be reported to the package distrib utor and to us in witten form. By transport with DHL please contact your local DHL office within 7 days.

3. RANGES OF APPLICATION

These diesel-pumps are made for pumping diesel or fuel oil ONLY! The AdBlue®-pump is intended exclusively for pumping AdBlue®
⚠ IMPORTANT!
They are not suitable for pumping ignitable liquids like gasoline, kerosene, or for pumping at places where the danger of an explosion exists. When using the pump, make sure there are no open flames, lighters, matches, cigarettes or similar things present around you. When operating suitable protective gloves must be worn.

These pumps are made for pumping clean diesel / biodiesel or fuel oil ONLY! The pumped liquid should not contain abrasive components. Abrasive components reduces pump life.

4. OPERATION

The installation must be performed by a qualified professional. Please, check each time before using, the electrical connections and the cables are not damaged. Also, it is NOT recommended to perform, for example, a cable extension. It is not certain whether this modification is technically correct, so this warranty is void. It must be ensured that the pump is sufficiently cooled during prolonged operation.
Diesel pumps are electrical products, which have to be protected against outer influences, f.e. caused by weather. Only use the pump in well-ventilated rooms and areas with enough fresh air. The floor, on which the pump may be used, should be flat. Please keep enough space from walls. The specified suction lift is the maximum suction at optimal conditions. Do not reduce the cross area of suction and discharge lines.

CAUTION: Do not connect more than 4m of 1″ hose on the pressure side. For smaller hose diameters, use shorter hose. Operation with dispensing guns is not recommended and is therefore at your own risk. These measures must be strictly adhered to in order to avoid damage to the pump.

Installation of the barrel pump

  1. Connect all parts correctly and ensure outlet connections are in proper placement.

  2. Apply power cord to the motor by plugging the power cord into a power source. Turn on the pump by use the on/off switch.
    The flow of the 230 volt pump can be adjusted with the flow regulating screw.

  3. Refuel as usual.

  4. When fueling is complete, return the nozzle to its storage position and turn off the pump.

profi-pumpe DPY01114-4 Diesel Barrel Pump Instruction Manual - Installation
of the barrel pump

⚠ ATTENTION!

5. SECURITY TIPS

profi-pumpe DPY01114-4 Diesel Barrel Pump Instruction Manual - SECURITY
TIPS

Diesel

  • If you do not intend to use the pump for an extended period of time, drain the fluid from the the pump, flush it out with diesel/heating oil and store it dry at room temperature
  • Pumping of liquids other than diesel or fuel oil is prohibited

AdBlue®

  • If you do not intend to use the pump for an extended period of time, drain the fluid from the the pump, flush it out with AdBlue®* and store it dry at room temperature
  • Pumping of liquids other than AdBlue®* is prohibited

AdBlue® can not be mixed with diesel, because the chemical is injected from a separate tank into the exhaust system. Where ammonia is released, which reacts with the nitrogen oxides in the catalyst and converts to nitrogen and water vapor
AdBlue®
consists of 32.5% urea and 67.5 of demineralized water.
AdBlue®* is odorless and non-toxic, not flammable, explosive or dangerous for the environment.

profi-pumpe DPY01114-4 Diesel Barrel Pump Instruction Manual -
DIESEL

THE MANUFACTURER EXPLAINS:

  • To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this user manual.
  • To reject every responsibility for the damages which originate from the improper use of the pump

6. SERVICING

Under normal pumping conditions the pump requires no servicing. But it is important to keep the suctions and delivery sections perfectly clean and free from all clogging. The following controls should be carried out regularly: l Intactness of the electric cable l That the connection hoses are not bent or broken l Cleanness of the pump medium Moreover, the pump should be emptied at risk of frost, be washed out with diesel/fuel oil and stored dry.

7. GUARANTEE REGULATIONS

For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the pump. Shipping costs shall not be borne by our company, except as required by law. Please report the warranty on our service platform http://www.profi-pumpe.de/service.php. We will inform you how to proceed with case-related. Please mark returns sufficient postage. Unfortunately not prepaid returns can not be accepted because they are filtered out before destination. We provide our service in Germany. The warranty does not cover:

  • Material wear (sealing rings, impeller wheels, impeller chambers)
  • Unjustified interventions or changes in the pump
  • Damages by self fault
  • Improper servicing and improper use
  • DRY RUNNIG (Also partially!) of the pump Moreover, we give no damage compensation for secondary damages!

8. RECOGNISING AND REPAIRING OF MISTAKES

profi-pumpe DPY01114-4 Diesel Barrel Pump Instruction Manual - RECOGNISING
AND REPAIRING OF MISTAKES

9. NOTES ON PRODUCT LIABILITY

We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.

10. NOTES ON DISPOSAL

Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to be disposed in your household garbage. We are registered at the German registration department EAR under the WEEE-No. DE79535656. This symbol means, that you’re not allowed to treat this product as a regular household waste item ­ it has to be disposed at a recycling collection point of electrical devices. This is the best way to save and protect our earth. THANK YOU FOR YOUR SUPPORT!

11. EU DECLARATION OF CONFORMITY

The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the product named overleaf, namely DIESEL 12V Fasspumpe, DIESEL 24V Fasspumpe, DIESEL 230V Fasspumpe, Adblue® 230V Fasspumpe as placed on the market, complies with the relevant provisions listed below, the relevant EU harmonised directives
and the EU standard for safety. This declaration of conformity applies insofar as no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer.

The sole authorised person to keep the technical documents: Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich

Low Voltage Directive (2014/35/EU) EC Electromagnetic compatibility directive (2014/30/EU)

The following harmonized standards: EN 60335-1:2012; EN 60335-2-41:2003+A2:2010; EN 55014-1:2006+A2:2011; EN 55014-2:1997+A2:2008 EN 61000-3-2:2006+A2:2009; EN 61000-3-3:2008; RoHS: 2011/65/EU

Signed for and on behalf of:

12. TECHNICAL DATA

profi-pumpe DPY01114-4 Diesel Barrel Pump Instruction Manual - TECHNICAL
DATA

*AdBlue®, a registered trademark of All products listed in this manual are Made in PRC. ****

At the time of printing this manual, the specifications were not available completely.
Please download the updated version now in our online shop.

profi-pumpe DPY01114-4 Diesel Barrel Pump Instruction Manual - At the time
of printing this manual

  1. Pump head
  2. Cable (powerline)
  3. Switch
  4. Motor
  5. Coupling
  6. Stub axle
  7. Deep grove bearing
  8. Seal ring
  9. Locking hand wheel
  10. Locking exit
  11. Outer pipe
  12. Pump tube
  13. Main shaft
  14. Tripod
  15. Seal ring
  16. Impeller
  17. Strainer
  18. Lower cover of the electric motor

Notes


Imprint

Amur S.à r.l.
www.amur.lu
Email: info@amur.lu
Tel.: +49 611 9458777-0
Fax: +49 611 9458777-11

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

profi-Pumpe User Manuals

Related Manuals