SAFETY INSTRUCTION AND WARNINGS
Please read the user manual before using the device
Warning sign
Pull power plug
Warning of electrical voltage
INTRODUCTION
We would like to congratulate you on the purchase of our pump. We appreciate
your trust.
That‘s why functional security and operational safety stands by us on first
place.
To prevent damage to persons or property, you should read this user manual
carefully. Please observe all safety precautions and instructions for proper
use of the pump. Failure to follow the instructions and safety precautions can
result in injury or property damage.
Please keep this manual with the instructions and safety instructions
carefully in order to at any time you can restore them. Please always download
the latest version of the user manual of www.profi-pumpe.de under „downloads“.
This shall always prevail.
IN GENERAL
The pumps in the catagorie Centrifugal Pumps are developed according to the
newest stand of technology, manufactured with much care and go under strict
intensive controls.
The pumps have been optimized by us especially for the special requirements
for circulating and filtering large volumes of water. Make sure after
unpacking the pump that the data given on the type label agree with the
included operating instructions. In the case of doubt the pump is not to be
used. Transport damages are immediately to be reported to the package
distributor and to us in witten form.
RANGES OF APPLICATION
These pumps are made for pumping clear water (free of mud and sand, see technical data) The pumps are made for the following ranges of application:
- Optimal for applications with highly fluctuating water demand
- For pressure boosting in private as well as public buildings
- Rainwater and service water utilization
- Other clear water pumping
IMPORTANT!
The pumps are designed for pumping clean water and chemically non-aggressive
liquids. Any guarantee is void in case of improper use. They are not suitable
for pumping flammable liquids or for use in places where there is danger of an
explosion. These pumps are intended for private and industrial use. These
pumps are designed for continuous use (without interruptions).
In continuous operation mode, the lifetime can be shortened accordingly. Never
run more than 5 minutes against a closed valve pump. Pump has integrated dry
run protection.
Never start and stop the pump more than 20 times per hour. When the pump
clocks, any claim under warranty is void.
Not suitable for use with solar photovoltaic panels.
INSTALLATION
The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the
cables are not damaged. Check before the installation whether the electrical
connections are earthed according to the statutory regulations and are
installed. The pump is to be secured
through a RCD circuit breaker with release current of 30 mA is technically
correct, so this warranty is void. It must be ensured that the pump is
sufficiently cooled during prolonged operation.
It is NOT recommended to perform even cable extensions or any other technical
modifications. The lines to the pump must be installed always steadily rising.
A transfer of mechanical loads or vibrations from the pump or to the pump must
be eliminated through
appropriate actions (use of rubber buffers, braided hoses, line fixation,
etc.). If the suction height is greater than 4m or the suction length is
greater than 9m, please make the suction line in 1 1/4“ (approx. 32mm) or 1
1/2“ (approx. 38mm) instead of 25mm. Do not reduce the suction line. All
pipe/hose connections to and from the pump must be sealed (e.g. Teflon tape or
sealing cord – no hemp!). Do not reduce the suction line. All pipe/hose
connections to and from the pump must be sealed. We recommend that you
implement the suction line „as one piece“ without any interruption in order to
prevent and avoid leaks. Check pump and water lines for leaks by pressure
testing min. 24 hours. Is dirt expected in the pump, an effective pre-filter
should be installed before the pump inlet. Fill pump and suction pipe/hose
with water. Please connect electrically pump with power supply. Start the
pump. If necessary, the pump and the suction line must be refilled until a
normal continuous operation has been established.
NOTE : Please note that a tapering of the pump connections may cause a
defect in the pump. Here, the terminal sizes specified should be strictly
adhered to. With strong restriction of flow through on the pressure side of
the pump (for example, due to clogged sand filter) water can come out of the
housing.
OPERATION
- Please open the cap of the filler neck, fill in as much water as is needed to allow it to escape from the neck, turn the cap back in clockwise after filling the water.
- Connect the power supply, the display shows „3.0“ or possibly „0.0“ bar.
- Set the pressure display range to display the set pressure value, the power indicator lights up.
- Open the discharge valve, press the „RUN“ button, start the pump.
- Under all operating conditions, pressing the „STOP“ button stops the pump.
- By pressing the “ “ or “ “ key, the setpoint value of the working pressure can be set; a short press of the “ “ key increases the pressure by 0.1 bar each time. A short press of the “ “ button reduces the pressure by 0.1 bar each, holding the buttons causes the pressure to rise or fall quickly.
- Open the water tap after setting the pressure, the control system regulates the pump according to the water demand. Check that the pump is running normally and that the pressure shown on the display is constant. If this is the case, the installation is complete. If you notice any irregularities, please read the point 10. RECOGNISING AND REPAIRING OF MISTAKES.
6.1 BUTTONS AND FUNCTIONAL DISCRIPTION
| Key function and display description
---|---
NO.| NAME| DESCRIPTION
1| Rotor Icon| The rotor icon rotates while pumping.
2| Performance bar| One bar corresponds to 10% of the power.
3| Online Icon| Appears as soon as more than two pumps are working.
4| Lock icon| Pressure or speed control is blocked.
5| Bluetooth| Not applicable.
6| VViFi| Not applicable.
7| Current value| Shows the current pressure value in bar. The pump stops at
0.0 bar.
8| Auto-Mode| Automatic constant voltage control mode.
9| Manu-Mode| Manual speed control mode.
10| Set value| Displays the manually set pressure value. The factory default
value is 3 bar.
11| Temperature unit| Lights up when querying temperature.
12| Speed unit| Wird im manuellen Modus angezeigt.
13| Pressure unit| Wird im automatischen Modus angezeigt.
14| Fault icon| Leuchtet mit dem entsprechenden Fehlercode auf.
15| Increase button| Pressing the key increases the pressure by 0.1 bar each
time, holding the key down causes the pressure to increase rapidly.
16| Decrease button| Pressing the key descrease the pressure by 0.1 bar at a
time, holding the key down causes the pressure to drop rapidly.
17| STOP button| Switches the pump off.
18| RUN button| Starts the pump in manual or automatic mode (with constant
pressure).
6.2 ERROR MESSAGES
| Fault code description
---|---
NO.| Code| FAULT CAUSE
1| oU| The voltage is higher than 280V and disappears when the voltage is
lower than 270V. Press the „RUN” button to cancel the protection,need to
return to the default setting to restore the overvoltage protection function.
2| LU| The voltage is lower than 80V and disappears when the voltage is higher
than 90V.Press the “RUN” button to cancel the protection, need to return to
the default setting to restore the overvoltage protection function.
3| oEP| The code appears when open phase occurs at the three-phase output
terminal or the three-phase voltage imbalance exceeds 20%. Normal operation
can be restored after manual troubleshooting.
4| oC| The temperature of the pump is above 80°C. Normal operation is
automatically restored when the temperature drops below 60°C. Press the „RUN”
button to cancel the protection. The factory temperature value needs to be
returned to the default setting to restore the over-temperature protection
function.
5| oS| the pressure sensor is damaged or not connected, and only be restored
after manual troubleshooting. Press the „RUN” button to cancel protection and
automatically switch to manual mode. Automatically restore protection after
Dower off and Dower on again.
6| oCP| The pressure of the pipe network is equal to 100% of the range of the
pressure sensor, automatically restored when it is lower than 90%.
7| oLd| Dry run protection in case of water shortage.
8| oLP| The motor is short-circuited / over-current, and restored after manual
troubleshooting.
9| EM| The temperature is higher than the set max. temperature.
10| EH| The rotor is locked and it should be troubleshooting manually.
11| EP| Phase is lost and it should be troubleshooting manually.
12| LL| When the continuous running time of the pump exceeds the set value, it
will automatically enter the protection program. After the water leakage fault
is ruled out or it is confirmed normal, restored by changing parameters or
restarting after power failure.
13| LP| When the pressure of the pipe network is continuously lower than the
set pressure, it automatically enters the water shortage protection function.
SECURITY TIPS
- Obey absolutely valid regulations on the electrical security
- Never run pump dry
- Pumping inflammable, as well as all other aggressive liquids is prohibited
- Pay attention to the medium temperature max. 90°C
- Never pull the pump on the electrical cable or pressure hose
- Avoid cross section narrowing
- Pay attention to the given particle size
- During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
- Test wells for enough flowing water (dry run danger)
- The pump is to be secured through a RCD circuit breaker with a release current of 30 mA
- The electrical connections are always to be carried out by an authorised professional
- The pump may be used by children aged 8 years and above as well as persons with reduced physical, sensory or mental abilities or those who lack skills, experience and knowledge only if they are supervised. These aforementioned persons should only use the appliance while adhering to safe instructions and resulting dangers.
- Cleaning and maintenance must not be carried out by children without supervision.
- Under certain circumstances, it is possible that that contamination of water is caused by leakage.
THE MANUFACTURER EXPLAINS:
- To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this book.
- To reject every responsibility for the damages which originate from the improper use of the pump.
SERVICING
It must be regularly checked the pump filter and clean if necessary. The
service intervals are based on the respective usage. We recommend a weekly
control in much dirt accumulation, if necessary daily inspection. Under normal
pumping conditions the pump requires no servicing.
With abrasive materials like sand the servicing duration can become shorter.
The following controls should be carried out regularly:
- Intactness of the electric cable
- Pre-pressure in the pressure tank (approx. 1.6 – 2.0 bar)
- Medium temperature max. 90°C
- That the connection hoses are not bent or broken
- Cleanness of the pump medium
Moreover, the pump should be emptied with risk of frost, be washed out with clear water and stored dry.
GUARANTEE REGULATIONS / STATUTORY WARRANTY
For all manufacturing and material defects, the statutory warranty applies. In
these cases we take the replacement or repair of the pump. Shipping costs
shall be borne by our company, except as required by law. Please report the
warranty on our service platform
www.profi-pumpe.de/information.php. We will inform you how to proceed with case-
related.
Returns please sufficient postage. Unfortunately not prepaid returns can not
be accepted because they are filtered out before delivery. Our service we
provide in Germany.
The warranty does not cover:
- Material wear (sealing rings, impeller wheels, impeller chambers)
- Unjustified interventions or changes in the pump
- Damages by selffault
- Improper servicing and improper use
- DRY RUNNIG (Also partially!) of the pump
Moreover, we give no damage compensation for secondary damages!
RECOGNISING AND REPAIRING OF MISTAKES
Problem | Possible cause | Solution |
---|---|---|
Pump runs, no water is being pumped / Highly fluctuating pressure | Air in the | |
suction line | Check suction line and connections for vacuum tightness | |
Air in the system (cannot escape) | Air in the system must be let out / Press |
RUN key several times for a few minutes
Impeller wheel is blocked| Impeller wheel must be cleaned
Pump does not start or switches itself off| Engine guard has switched the pump
off| Pump needs to be cooled
No electricity| Check electrical connections
Pump runs, Pump capacity slows down or stops| Pump does not suck in water|
Install pump lower
Hose connections systems have a leak| Check hose connection systems
Impeller wheel is worn down| Change impeller wheel
Filter has become dirty| Clean filter
NOTES ON PRODUCT LIABILITY
We point out, that we are only liable for damages under the Product Liability
Act, which are caused by our units if no changes were made to the equipment.
If repairs are carried out by our authorized service, we are only liable if
original spare parts and accessories were used.
NOTES ON DISPOSAL
**** Electro devices of our company, labeled with the symbol of the crossed
trash bin, are not permitted to be disposed in your household garbage. We are
registered at the German registration department EAR under the WEEE-No.
DE79535656.
This symbol means, that you’re not allowed to treat this product as a regular
household waste item – it has to be disposed at a recycling collection point
of electrical devices.
This is the best way to save and protect our earth.
THANK YOU FOR YOUR SUPPORT!
EU DECLARATION OF CONFORMITY
The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies
that the product named overleaf, namely INVERT-TECH 4-800/4-1200 as placed on
the market, complies with the relevant provisions listed below, the relevant
EU harmonised directives and the EU standard for safety. This declaration of
conformity applies insofar as no modifications are made to the product. The
sole responsibility for issuing this declaration of conformity lies with the
manufacturer.
The sole authorised person to keep the technical documents:
Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich
Machinery Directive (2006/42/EC)
Low Voltage Directive (2014/35/EU)
EC Electromagnetic Compatibility Directive (2014/30/EU)
The following harmonized standards:
EN ISO 12100:2010; EN 809:1998+A1:2009+AC:2010;
EN 60204-1:2018; EN 60335-1:2012+A13:2017;
EN 60335-2-41:2003+A1:2004+A2:2010;
EN 62233:2008+AC:2008; EN 60034-1:2010+AC:2010;
EN 55014-1:2017; EN 55014-2:2015; EN 61000-3-2:2014;
EN 61000-3-3:2013
RoHS: 2011/65/EU
Signed for and on behalf of:
Amur S.à r.l.
Remich, 22.02.2023
TECHNICAL DATA
English| INVERT-TECH 4-800
HWO1117| INVERT-TECH 4-1200
HW01118
---|---|---
Power| 800 W| 1200 W
Voltage| —230V/ 50Hz| —230V/ 50Hz
Max. head| 38 m| 54 m
Max. flow| 5,1 m’/1| 7,0 in3/h
Max. speed| 3500 RPM / UPM| 3500 RPM / UPM
Max. temperature| 90°C| 90°C
Protective class| IPX5| IPX5
Measures in mm| 325x161x425| 343x161x425
Inlet Connection (A1)| G1| G1
Outlet Connection (A2)| G1| G1
Total length (L1)| 325| 343
Partial length (L2)| 115| 133
Partial length (L3)| 30| 40
Fastening Screws (S1)| M8| M8
Service
Name| Date| Signature| Performed service work (as precise
and detailed as possible)
---|---|---|---
| | |
| | |
| | |
INSTALLATION SCHEME
Schematic illustration as an example. Please refer to the offer description for the contents of delivery.
Imprint
Amur S.à r.l.
www.amur.lu
Email:info@amur.lu
Tel.: +49 611 9458777-0
Fax: +49 611 9458777-11
Documents / Resources
|
profi-pumpe 4-800 Inverter-Automatic Water Booster
Pump
[pdf] Instruction Manual
4-800 Inverter-Automatic Water Booster Pump, 4-800, Inverter-Automatic Water
Booster Pump, Automatic Water Booster Pump, Water Booster Pump, Booster Pump,
Pump
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>