profi-pumpe PSM01120V Flow Switch 3.2 Instruction Manual

June 13, 2024
profi-Pumpe

FLOW SWITCH 3.2
DURCHFLUSSWÄCHTER 3.2
Version 23.02
profi-pumpe PSM01120V Flow Switch 3.2

Technical changes, misprints and mistakes reserved! Newest information about our products can be found online
http://www.profi-pumpe.de

SAFETY INSTRUCTION AND WARNINGS

| Please read the user manual before using the device
---|---
| Warning sign
| Pull power plug
| Warning of electrical voltage

INTRODUCTION

We would like to congratulate you on the purchase of our flow switch. We appreciate your trust.
That‘s why funtional security and operational safety stands by us on first place.
To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the 3.2. Failure to follow the instructions and safety precautions can result in injury or property damage.
Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them. Please always download the latest version of the user manual of www.profi-pumpe.de under „downloads“. This shall always prevail.

IN GENERAL

The 3.2 is a circuit device that an electrical load (pump) automatically switches on and off. The device monitors the pressure and the flow in the pressure line. Depending upon the pressure or the flow rate, the AC switch 5 one or more electrical consumers (MAX 10A) on and off.
The 3.2 is to be used exclusively for non abrasive clear water without debris and other dirt. In the opposite case, an effective pre-filter with a mesh size should be installed no coarser than 0.2 mm in front of the device.
The manometer indicates the pressure in the system. It helps to monitor the proper pump function and to detect leaks in the system.
Make sure after unpacking that the data given on the nameplate agree with the foreseen operating conditions. When in doubt, the operation is prohibited.
Transport damages are reported immediately to the transport company and to us in writing.

INSTALLATION

  • The device is installed at any point between the outlet of the pump and the first collector, so that the direction of the arrow on the side between the two 1 „connections with the flow direction of the fluid in the pipeline matches. Make sure that the hydraulic connections are completely sealed. If a pump with maximum pressure used above 7 bar, a pressure reducer at the entrance of the device must be installed. The pump controller is to be used only for pumps that produce a minimum pressure of 2.5 bar at the device installation point.
  • The electrical connection of the unwired version is after the electrical diagram (see paragraph.
  1. produce. If a consumer is used with a power more than 1.1 kW and the ambient temperature is higher than 25 °C, must be used for the wiring is not less than 99 °C cable with heat resistance. For wiring, only use this specific pliers. When ready to plug in wired version, it is sufficient to connect the power cord of the pump with the outlet of 3.2 and shut the power plug of 3.2 to an electrical outlet the power grid on.
  • The pressure at which the device starts is set to 1.5 bar, this pressure is optimal for most applications.
  • The height of the water column above the 3.2 should not exceed 10m.

Warning : no additional check valve should be installed between the pump and the 3.2, as it sometimes causes problems.

OPERATION

The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the cables are not damaged. Check before the installation whether the electrical connections are earthed according to the statutory regulations and are installed.
Also, it is NOT recommended to perform, for example, a cable extension. It is not certain whether this modification is technically correct, so this warranty is void.

SECURITY TIPS

  • Obey absolutely valid regulations on the electrical security
  • To avoid shocks and fire risks, read and follow closely the following instructions:
  • Always unplug the device from the mains before carrying out any work on it.
  • Be sure that the electric line connecting the device to the mains and the extension  leads have a cross-section suitable for pump power and be sure that the electrical connections are far away from any water source
  • When Flow guard is used for swimming pools, ponds and fountains if is necessary to use an automatic RCD with IDn = 3OmA protection.

Warning : when the pump stops the pipes are under pressure consequently we recommend opening a tap to discharge the system before carrying out any work.

  • The electrical connections are always to be carried out by an authorised professional
  • The pump may be used by children aged 8 years and above as well as persons with reduced physical, sensory or mental abilities or those who lack skills, experience and knowledge only if they are supervised. These aforementioned persons should only use the appliance while adhering to safe instructions and resulting dangers.
  • Cleaning and maintenance must not be carried out by children without supervision.
  • The pump must not be used or operated under any circumstances when there are people in the same water.
  • Under certain cirumstances, it is possible that that contamination of water is caused by leakage.

THE MANUFACTURER EXPLAINS:

  • To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this book.
  • To reject every responsibility for the damages which originate from the improper use of the device.

SERVICING

It may happen occasionally that dirt is retained in the internal check valve and this is no longer seals 100%. The first remedy should be always trying to flush the check valve free. For this purpose, eg. As the Garden side faucet on full blast, so that the pump at full rated power promotes about 30 minutes water. Is then the timing is not clear, the unit must be replaced. Prior to installation of the new device, the pump is in, free to flush any case, as previously described.
Opening the device on non-return valve is prohibited and always results in the loss of any existing warranty. In addition, persons could be dangerous when Operating a clocking pump occur, so that the pump may be operated under any circumstances continue. Until the device replacement, the pump must be taken out of service. For abrasive materials such as sand, shortening the Maintenance period and the device lifetime.

The following checks should be carried out regularly:

  • functional test (min. every 3 months)
  • integrity of the power cord
  • Clean the guide lines (eg no buckling)
  • Clean the media (no sand, no sludge)

GUARANTEE REGULATIONS / STATUTORY WARRANTY

For all manufacturing and material defects, the statutory warranty applies. In these cases, we assume the Exchange or appliance repairs. Shipping costs are borne by us only to the extent legally is prescribed.
In case of warranty please call our service platform http://www.profi- pumpe.de/service.php log the event.
Then we will inform you how to proceed with case by case basis.
Returns please sufficient postage. Unfortunately prepaid returns will not be accepted, because they are filtered out before delivery. Our service we provide in Germany.
The warranty does not cover:

  • Improper installation (proper installation, unauthorized persons)
  • Material wear (eg. seals) or dirt in the unit
  • Unjustified interventions or changes in the device
  • Damages by selffault
  •  Improper servicing and improper use
    Moreover, we give no damage compensation for secondary damages!

RECOGNISING AND REPAIRING OF MISTAKES

Problem Motiliche Ursache Losung

The pump permanently switches on and off
(Pump clocked)| The system has leaks. Internal check valve may leak| Vent system
Check system to dripping pipes!cets / valves.
Check non-return valve in the unit for leaks
The pump will not start| 1.No mains voltage present
2.Too much difference in height between the device and a customer (taps)
3.The pump is defective
4.Malfunction of the device| 1.Check the electrical connections
2.Reduce height difference
3.Contact a qualified technician
4.Montact the merchant
The pump will not stop| 1.The system has greater leakages
2.Malfunction of the device
3.Internal check valve is dirty| 1.Check the system
2.contact the dealer
3.Pump + Rinse machine (see 6)

NOTES ON PRODUCT LIABILITY

We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.

NOTES ON DISPOSAL

**** Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to be disposed in your household garbage. We are registered at the German registration department EAR under the WEEE-No. DE79535656.
This symbol means, that you’re not allowed to treat this product as a regular household waste item – it has to be disposed at a recycling collection point of electrical devices. This is the best way to save and protect our earth.
THANK YOU FOR YOUR SUPPORT!

EU DECLARATION OF CONFORMITY

The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the product named overleaf, namely DURCHFLUSSWÄCHTER 3.2 AUTOMATIC- CONTROLLER VERKABELT / UNVERKABELT as placed on the market, complies with the relevant provisions listed below, the relevant EU harmonised directives and the EU standard for safety. This declaration of conformity applies insofar as no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer.
The sole authorised person to keep the technical documents:
Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich
Low Voltage Directive (2014/35/EU)
EC Electromagnetic compatibility directive (2014/30/EU)
The following harmonized standards:
EN 60730-1:2016; EN 60730-2-6:2016; EN 55014-1:2017; EN 55014-2:2015;
EN 61000-3-2:2014; EN 61000-3-3:2013;
RoHS: 2011/65/EU
Signed for and on behalf of:
Amur S.à r.l.
Remich, 22.02.2023

TECHNICAL DATA

English PSM01120V / PSM01119U
Tension/Voltage ~230V bei 50/60Hz
Max. Current 10A
Max. Power demand 1,1 kW
Rating pressure 1,5 bar
Max. working Pressure 7 bar
Max. operating Pressure 7 bar
Max water temperature 35 °C
Input connector 2,54 cm (1“)
Output connector 2,54 cm (1“)
Protection-grade IP65

ELECTRICAL INSTALLATION/ELEKTRISCHER ANSCHLUSS-PLAN UND INSTALLATIONSSCHEMA

1. Pump  brown(Phase)
2. Pump  green-yellow(Erde)
3. Pump  blue (Null)
4. Power  brown(Phase)
5. Power  green-yellow (Erde)
6. Power  blue/(Null)

The device is normally connected as shown in figure. Pumps can be operated on the device with higher performance, with a current consumption over 10A, and even three-phase pumps. In this case, the connection means of a suitable circuit protection is provided (more information can be found on our Internet site.

Notes ——————–

Imprint

Amur S.à r.l.
www.amur.lu
Email:info@amur.lu
Tel.: +49 611 9458777-0
Fax: +49 611 9458777-11

Documents / Resources

| profi-pumpe PSM01120V Flow Switch 3.2 [pdf] Instruction Manual
PSM01120V Flow Switch 3.2, PSM01120V, Flow Switch 3.2, Switch 3.2
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

profi-Pumpe User Manuals

Related Manuals