VAGNER POOL Dynamik Time Dosing Peristaltic Pump Instruction Manual
- June 13, 2024
- VAGNER POOL
Table of Contents
DYNAMIK TIME
INSTRUCTIONS MANUAL
General Features
- Power Supply 100÷240 Vac
- Digital Display
- Priming (MOM), Run (ON), Stand-by (OFF) mode selectable by switch
- Flow rate 4, 2 and 1 l/h (at 1,5 Bar) selectable by programming menù
- External trigger 24÷240 Vac
Functioning:
-
Priming mode (Switch position MOM / Priming) “Pump run for all time long that the switch is pressed”
-
Working mode (Switch position ON / Run) “Wait trigger to start dosing”
Pump waits a “trigger” and the display shows A_on flashing
When the pump receives a “trigger”, it start to dose and the display shows Arun flashing.
Pump can works in the following two ways:
A. Batch Dosing: the pump starts every time receive the external trigger and work only for the set active time:
a1. set A (activation time) from 1 to 60 min and P (pause time) to 0.
i) Example with A= 5 and P=0 minutes: the pump doses for 5 minutes every time a trigger comes;B. Cyclic Dosing: the pump works cyclically until the trigger is present.
b1. 2) set A (activation time) and P (pause time) from 1 to 60 minutes
ii) Example with A= 5 and P=8 minutes: the pump works for 5 minutes (ON) and stop for 8 minutes (OFF) until the trigger is present; -
Programming mode (Switch position OFF / Stand-by) “Pump is stopped”
Press Time key to adjust dosing time limit:
- A (Active – dosing time) from 1 to 60 minutes
- P (Pause – wait time) from 0 to 60 minutes
Press Dosing to adjust flow rate pump:
A = Summer 4 l/h
B = Middle season 2 l/h
C = Winter 1 l/h
Customer may use this function to select the desired dosing amount according
to the season or to the period of use of the swimming pool.
code: 0000136964