DiNUY EGEPDIA1 Analog Time Switch
Features
230V AC +/- 10% (50/60)Hz
-5…+50°C
16 (1,5) A 250V
2000 Wa
Operating instructions
Slide Switch (3)
Automatic operation:
The output switches according to the program selected with the tappets
Permanently On: The output is always on.
Permanently OFF
Input actual time:
Turn the tappet (4) wheel in the direction of the vertical arrow.
Switch-program input:
Move the tappets to the left to switch ON. The time period of one tappet is 30
minutes.
Time Switches with reserve.
During a supply interruption the time switch runs for approximately 72h.
Installation details
The installation and assembly of electrical equipment must be only carried out only by a skilled person!
Otherwise exists fire danger or danger of an electric shock
Warranty void if housing opened by unauthorised person.
The electronic circuit is protected against a wide range of external
influences.
Incorrect operating may occur if external influences exceed certain limits.
Connections
Connect the supply voltage/frequency as stated on the product label in accordance with the connection details shown for this time switch and the appliance/s to be switched.