profi-pumpe 750-2 Submersible Well Pumps
Product Information
The product is a submersible water pump designed for pumping clear water. It is available in different models, including the Brunnen-Star 2250-4, Brunnen- Star 550-4, Brunnen-Star 750-2, and Brunnen-Star 1100-4. The pumps are suitable for various applications such as domestic water use from wells, circulation of large accumulations of water from containers, and other plain water pumping.
Technical Specifications
- Model: Brunnen-Star (various models)
- Version: 22.12
- Power Source: Electric
- Application: Pumping clear water
- Particle Size: Water may need to be pre-filtered to 0.2 mm
particle size
Safety Instructions and Warnings
- Please read the user manual before using the device.
- Pull the power plug before performing any maintenance or repairs.
- Be cautious of electrical voltage and follow the warning signs.
Assembly Instructions
Due to their size, the pump and motor modules are delivered partly separately. Follow the steps below for assembly:
- Slide the motor shaft into the housing of the pump shaft.
- Screw the two modules together, ensuring that the screws are tightened crosswise and evenly.
- Mount the filter strainer as shown in Figure 1.
(Figure 1: Insert image of assembly diagram here)
Installation Scheme
The installation must be carried out as shown in Figure 2a. It is recommended to install a pressure switch (Figure 2b) to monitor the function of the pump and protect it from damage.
(Figure 2a: Insert image of installation scheme here)
(Figure 2b: Insert image of pressure switch here)
Security Tips
- Avoid cross-section narrowing during installation.
- Pay attention to the given particle size and pre-filter the water if necessary.
- Before storing the pump for a long period, clean it with clear water and ensure it is dry.
- Test wells for sufficient flowing water to prevent dry run danger.
- The pump should be secured through a RCD circuit breaker with a release current of 30 mA.
- Always have electrical connections carried out by an authorized professional.
- The pump can be used by children aged 8 years and above, as well as persons with disabilities, under supervision.
Technical changes, misprints and mistakes reserved! Newest information about our products can be found online : http://www.profi-pumpe.de
SAFETY INSTRUCTION AND WARNINGS
- Please read the user manual before using the device
- Warning sign
- Pull power plug
- Warning of electrical voltage
INTRODUCTION
We would like to congratulate you on the purchase of our pump. We appreciate your trust. That‘s why funtional security and operational safety stands by us on first place.
To prevent damage to persons or property, you should read this user manual
carefully. Please observe all safety precautions and instructions for proper
use of the pump. Failure to follow the instructions and safety precautions can
result in injury or property damage.
Please keep this manual with the instructions and safety instructions
carefully in order to at any time you can restore them. Please always download
the latest version of the user manual of www.profi-pumpe.de under „downloads“.
This shall always prevail.
IN GENERAL
The pumps are developed according to the newest stand of technology,
manufactured with much care and go under strict intensive controls. These
pumps were optimised by us in particu-lar for the special demands in dirty
water areras. Make sure after unpacking the pump that the data given on the
type label match with the included operating instructions. In case of doubt
the pump is not to be used.
Transport damages are immediately to be reported to the package distributor
and to us in writ-ten form.
RANGES OF APPLICATION
These pumps are made for pumping clear water (free of mud and sand and
aggressive chemical substances (see technical data). The water may have to be
pre-filtered to 0.2 mm particle size
The pumps are made for the following ranges of application:
- domestic water use from wells with diameter from 3-inch diameter
- circulation of large accumulations of water from containers
- Other plain water pumping
IMPORTANT!
The pumps are designed for pumping clean water and chemically non-aggressive
liquids. Any guarantee is void in case of improper use. They are not suitable
for pumping flammable liquids or for use in places where there is a risk of
explosion. The pumps are designed for home use in the house and garden.
These pumps are designed for continuous use provided (max. 20 interruptions
per hour). Never run more than 2-3 minutes against a closed valve pump.
(Install dry running protection) pump adequately secured against dry running.
The pump must not be used in swimming pools.
Not suitable for use with solar photovoltaic panels.
OPERATION
The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the
cables are not damaged. Check before the installation whether the electrical
connections are earthed according to the statutory regulations and are
installed. The pump is to be secured through a RCD circuit breaker with
release current of 30 mA.
Also, it is NOT recommended to perform, for example, a cable extension. It is
not certain whether this modification is technically correct, so this warranty
is void. It must be en-sured that the pump is sufficiently cooled during
prolonged operation.
ASSEMBLING
Due to their size, pump and motor modules are delivered partly separately. The
assembly is carried out as shown in Figure 1.
Slide the motor shaft into the housing of the pump shaft. Screw the two
modules together.
Please make sure that the screws are tighten-ed crosswise and evenly.
Then mount the filter strainer as shown.
INSTALLATION SCHEME
The installation must be carried out as shown in Fig. 2a. We recommend the installation of a pressure switch (Fig. 2b), which monitors the function of the pump and protects it from damage.
SECURITY TIPS
-
Obey absolutely valid regulations on the electrical security
-
Never run pump dry
-
Pumping inflammable, as well as all other aggressive liquids is prohibited
-
Pay attention to the medium temperature max. 35°C
-
Never pull the pump on the electrical cable or pressure hose
-
Avoid cross section narrowing
-
Pay attention to the given particle size
-
During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
-
Test wells for enough flowing water (dry run danger)
-
The pump is to be secured through a RCD circuit breaker with a release current
of 30 mA. -
The electrical connections are always to be carried out by an authorised professional.
-
The pump may be used by children aged 8 years and above as well as persons with reduced physical, sensory or mental abilities or those who lack skills, experience and knowledge only if they are supervised. These aforementioned persons should only use the appliance while adhering to safe instructions and resulting dangers.
-
Cleaning and maintenance must not be carried out by children without supervision.
-
The pump must not be used or operated under any circumstances when there are people in the same water.
-
Under certain cirumstances, it is possible that contamination of water is caused by leakage.
THE MANUFACTURER EXPLAINS:
- To take over no responsibility in the case of accidents or damages on the basis of careless-ness or disregard to the instructions in this book.
- To reject every responsibility for the damages which originate from the improper use of the pump.
SERVICING
Under normal pumping conditions the pump requires no servicing. From an
operating period (with clear water) of approx. 2000 hours the mechanical
components should be checked: impeller wheels, chambers, sealing rings etc. on
wear and if necessary be changed. After 3000 pumping hours the oil in the
chamber should also be changed, if necessary (only with oil-dipped engine
types!). Please, only fill it up to 80% and check the sealing rings always for
density.
With abrasive materials like sand the servicing duration can become shorter.
The following controls should be carried out regularly:
- Intactness of the electric cable
- That the connection hoses are not bent or broken
- Cleanness of the pump medium
Moreover, the pump should be emptied with risk of frost, be washed out with clear water and stored dry.
GUARANTEE REGULATIONS
For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the pump. Shipping costs shall be borne by our company, except as required by law. Please report the warranty on our service platform http://www.profi-pumpe.de/service.php. We will inform you how to proceed with case-related. Returns please sufficient postage. Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery. Our service we provide in Germany.
The warranty does not cover:
- Improper installation (self-installation, unauthorized persons)
- Material wear (sealing rings, impeller wheels, impeller chambers)
- Unjustified interventions or changes in the pump
- Damages by selffault
- Improper servicing and improper use
- DRY RUNNING (Also partially!) of the pump
Moreover, we give no damage compensation for secondary damages!
RECOGNISING AND REPAIRING OF MISTAKES
Problem | Possible cause | Solution |
---|
Pump runs, no water is being pumped
| Air in the system (cannot es- cape)| Air in the system must be let out
Impeller wheel is blocked| Impeller wheel must be cleaned
Pump does not start or swit- ches itself off
| Engine guard has switched the pump off| Pump needs to be cooled
No electricity| Check electrical connections
Pump runs, Pump capacity slows down or stops
| Pump is inserted to deep| Insert pump not so deep
Hose connections systems have a leak| Check hose connection systems
Impeller wheel is worn down| Change impeller wheel
Filter has become dirty| Clean filter
NOTES ON PRODUCT LIABILITY
We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.
NOTES ON DISPOSAL
Electro devices of our company, labeled with the symbol of the crossed trash
bin, are not permitted to be disposed in your household garbage. We are
registered at the German registration department EAR under the WEEE-No.
DE79535656.
This symbol means, that you’re not allowed to treat this product as a regular
household waste item – it has to be disposed at a recycling collection point
of electri-cal devices. This is the best way to save and protect our earth.
THANK YOU FOR YOUR SUPPORT!
EU DECLARATION OF CONFORMITY
The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies
that the products named overleaf, namely 3” BRUNNEN-STAR 250-4, 3” BRUNNEN-
STAR 550-4, 3” BRUNNEN-STAR 750-2 , 3” BRUNNEN-STAR 1100-4 as placed on the
market, comply with the relevant provisions listed below, the relevant EU
harmonised directives and the EU standard for safety. This declaration of
conformity applies insofar as no modifications are made to the product. The
sole responsibility for issuing this declaration of conformity lies with the
manufacturer.
The sole authorised person to keep the technical documents:
Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich
Low Voltage Directive (2014/35/EU)
EC Electromagnetic compatibility directive (2014/30/EU)
EN ISO 12100:2010; EN 809:1998+A1:2009+AC:2010; EN 60204-1:2018;
EN 60335-1:2012+A 11:2014+A13:2017+A1:2019+A14:2019+A2:2019; EN
60335-2-41:2003+A1:2004+A2:2010; EN 62233:2008+AC:2008; EN 55014-
1:2017+A11:2020; EN 55014-2:2015; EN IEC 61000-3-2:2019; EN 61000-3-
3:2013+A1:2019
ROHS: 2011/65/EU
Signed for and on behalf of:
Amur S.à r.l.
Remich, 22.12.2022
i.V. Dipl. Phys. Peter NeumüllerTechnical Manager
TECHNICAL DATA
English| 5 007 006 002| 5 007 006 003| 5 007 006
004| 5 007 006 005
---|---|---|---|---
Power Achievement| 250 Watt| 550 Watt| 750 Watt| 1100 Watt
Max. pump capacity| 3,7 m³/h| 3,7 m³/h| 3,7 m³/h| 4,5 m³/h
Max. pressure| 4,1 bar| 6,1 bar| 8,1 bar| 11,4 bar
Max. pump height| 41 m| 61 m| 81 m| 114 m
Max. water temperature| 35°C| 35°C| 35°C| 35°C
Max. particle size| 0,2 mm| 0,2 mm| 0,2 mm| 0,2 mm
Protection grade| IPX8| IPX8| IPX8| IPX8
Electrical tension| 230V/50 Hz| 230V/50 Hz| 230V/50 Hz| 230V/50 Hz
Connection pressure side (IT)| 1”| 1”| 1”| 1”
Diameter with cable protection| 80 mm| 80 mm| 80 mm| 80 mm
Height| 810 mm| 1015 mm| 1210 mm| 1490 mm
Weight| 15 kg| 18 kg| 18 kg| 25 kg
Cable length| 15 m| 15 m| 15 m| 15 m
SPARE PARTS
The spare parts will be available for purchase from AMUR S.à.r.l. at www .profi-pumpe.de from March 2023.
| 3” Tiefbrunnenpumpe
BRUNNEN-STAR 250- 4
(5 007 006 002)
| 3” Tiefbrunnenpumpe
BRUNNEN-STAR 550- 4
(5 007 006 003)
| 3” Tiefbrunnenpumpe
BRUNNEN-STAR 750- 2
(5 007 006 004)
| 3” Tiefbrunnenpumpe
BRUNNEN-STAR 1100- 4
(5 007 006 005)
---|---|---|---|---
Pump Part without Motor
| –| BP01208| BP01148| BP01150
| | |
Motor only without Connection Box
| –| BP01207| BP01147| BP01149
|
|
|
Connection Box
| –| BP09108| –|
| | |
Please note our disposal advice at section 12.
Amur S.à r.l.
www.amur.lu
Email: info@amur.lu
Tel.: +49 611 9458777-0
Fax: +49 611 9458777-11
References
Read User Manual Online (PDF format)