profi-pumpe Hauswasserwerk Inverter 3 Automatic Water Booster Pump Instruction Manual

June 13, 2024
profi-Pumpe

profi-pumpe Hauswasserwerk Inverter 3 Automatic Water Booster Pump

SAFETY INSTRUCTION AND WARNINGS

Please read the user manual before using the device
Pull power plug
Warning sign
Warning of electrical voltage

INTRODUCTION

We would like to congratulate you on the purchase of our pump. We appreciate your trust.
That‘s why funtional security and operational safety stands by us on first place.

To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the pump. Failure to follow the instructions and safety precautions can result in injury or property damage. Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them. Please always download the latest version of the user manual ofwww.profi-pumpe.de under „downloads“. This shall always prevail.

IN GENERAL

The pumps in the categories Centrifugal Pumps are developed according to the newest stand of technology, manufactured with much care and go under strict intensive controls. The pumps have been optimized by us especially for the special requirements for circulating and filtering large volumes of water. Make sure after unpacking the pump that the data given on the type label agree with the included operating instructions. In the case of doubt the pump is not to be used. Transport damages are immediately to be reported to the package distributor and to us in Witten form.

RANGES OF APPLICATION

These pumps are made for pumping clear water (free of mud and sand, see technical data)
The pumps are made for the following ranges of application:

  • Optimal for applications with highly fluctuating water demand
  • For pressure boosting in private as well as public buildings
  • Rainwater and service water utilization
  • Other clear water pumping

IMPORTANT!

The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any guarantee is void in case of improper use. They are not suitable for pumping flammable liquids or for use in places where there is danger of an explosion. These pumps are intended for private and industrial. These pumps are designed for continuous use (without interruptions). In continuous operation mode, the lifetime can be shortened accordingly. Never run more than 5 minutes against a closed valve pump. Pump has integrated dry run protection.

Never start and stop the pump more than 20 times per hour.
When the pump clocks, any claim under warranty is void.
Not suitable for use with solar photovoltaic panels.

INSTALLATION

The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the cables are not damaged. Check before the installation whether the electrical connections are earthed according to the statutory regulations and are installed. The pump is to be secured through a RCD circuit breaker with release current of 30 mA is technically correct, so this warranty is void. It must be ensured that the pump is sufficiently cooled during prolonged operation.

It is NOT recommended to perform even cable extensions or any other technical modifications.
The lines to the pump must be installed always steadily rising. A transfer of mechanical loads or vibrations from the pump or to the pump must be eliminated through appropriate actions (use of rubber buffers, braided hoses, line fixation, etc.). If the suction height is greater than 4m or the suction length is greater than 9m, please make the suction line in 1 1/4“ (approx. 32mm) or 1 1/2“ (approx. 38mm) instead of 25mm. Do not reduce the suction line.
All pipe/hose connections to and from the pump must be sealed (e.g. Teflon tape or sealing cord – no hemp!). We recommend that you implement the suction line „as one piece“ without any interruption in order to prevent and avoid leaks. Check pump and water lines for leaks by pressure testing min. 24 hours. Is dirt expected in the pump, an effective pre-filter should be installed before the pump inlet. Fill pump and suction pipe/hose with water. Please connect electrically pump with power supply. Start the pump. If necessary, the pump and the suction line must be refilled until a normal continuous operation has been established.

OPERATION

  • Please open the cap of the filler neck, fill in as much water as is needed to allow it to escape from the neck, turn the cap back in clockwise after filling the water.

  • Connect the power supply, the display shows „3.0“ or possibly „0.0“ bar.

  • Set the pressure display range to display the set pressure value, the power indicator lights up.

  • Open the discharge valve, press the „RUN“ button, start the pump.

  • Under all operating conditions, pressing the „STOP“ button stops the pump.

  • By pressing the “ ∧ “ or “ ∨ “ key, the setpoint value of the working pressure can be set; a short press of the “ ∧ “ key increases the pressure by 0.1 bar each time. A short press of the “ ∨ “ button reduces the pressure by 0.1 bar each, holding the buttons causes the pressure to rise or fall quickly.

  • Open the water tap after setting the pressure, the control system regulates the pump according to the water demand. Check that the pump is running normally and that the pressure shown on the display is constant. If this is the case, the installation is complete.
    If you notice any irregularities, please read the point 10. RECOGNISING AND REPAIRING \ OF MISTAKES.

BUTTONS AND FUNCTIONAL DISCRIPTION

NO. NAME KEY FUNCTION AND DISPLAY DESCRIPTION
1 Rotor Icon The rotor icon rotates while pumping.
2 Performance bar One bar corresponds to 10% of the power.
3 Online Icon Appears as soon as more than two pumps are working.
4 Lock icon Pressure or speed control is blocked.
5 Bluetooth Not applicable.
6 WiFi Not applicable.
7 Current value Shows the current pressure value in bar. The pump stops at

0.0 bar.
8| Auto-Mode| Automatic constant voltage control mode.
9| Manu-Mode| Manual speed control mode.
10| Set value| Displays the manually set pressure value. The factory default value is 3 bar.
11| Temperature unit| Lights up when querying temperature.
12| Speed unit| Wird im manuellen Modus angezeigt.
13| Pressure unit| Wird im automatischen Modus angezeigt.
14| Fault icon| Leuchtet mit dem entsprechenden Fehlercode auf.
15| Increase button| Pressing the key increases the pressure by 0.1 bar each time, holding the key down causes the pressure to increase rapidly.
16| Decrease button| Pressing the key decrease the pressure by 0.1 bar at a time, holding the key down causes the pressure to drop rapidly.
17| STOP button| Switches the pump off.
18| RUN button| Starts the pump in manual or automatic mode (with constant pressure).

ERROR MESSAGES

NO. Code FAULT CAUSE – FAULT CODE DESCRIPTION
1 oU The voltage is higher than 280V and disappears when the voltage is

lower than 270V. Press the „RUN“ button to cancel the protection,need to return to the default setting to restore the overvoltage protection function.
2| LU| The voltage is lower than 80V and disappears when the voltage is higher than 90V.Press the “RUN” button to cancel the protection, need to return to the default setting to restore the overvoltage protection function.
3| oEP| The code appears when open phase occurs at the three-phase output terminal or the three-phase voltage imbalance exceeds 20%. Normal operation can be restored after manual troubleshooting.
4| oC| The temperature of the pump is above 80°C. Normal operation is automatically restored when the temperature drops below 60°C. Press the „RUN“ button to cancel the protection. The factory temperature value needs to be returned to the default setting to restore the over-temperature protection function.
5| oS| the pressure sensor is damaged or not connected, and only be restored after manual troubleshooting. Press the

„RUN“ button to cancel protection and automatically switch to manual mode. Automatically restore protection after power off and power on again.

6| oCP| The pressure of the pipe network is equal to 100% of the range of the pressure sensor, automatically restored when it is lower than 90%.
7| oLd| Dry run protection in case of water shortage.
8| oLP| The motor is short-circuited / over-current, and restored after manual troubleshooting.
9| EAA| The temperature is higher than the set max. temperature.
10| EH| The rotor is locked and it should be troubleshooting manually.
11| EP| Phase is lost and it should be troubleshooting manually.
12| LL| When the continuous running time of the pump exceeds the set value, it will automatically enter the protection program. After the water leakage fault is ruled out or it is confirmed normal, restored by changing parameters or restarting after power failure.
13| LP| When the pressure of the pipe network is continuously lower than the set pressure, it automatically enters the water shortage protection function.

SECURITY TIPS

  • Obey absolutely valid regulations on the electrical security
  • Never run pump dry
  • Pumping inflammable, as well as all other aggressive liquids is prohibited
  • Pay attention to the medium temperature max. 90°C
  • Never pull the pump on the electrical cable or pressure hose
  • Avoid cross section narrowing
  • Pay attention to the given particle size
  • During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
  • Test wells for enough flowing water (dry run danger)
  • The pump is to be secured through a RCD circuit breaker with a release current of 30 mA
  • he electrical connections are always to be carried out by an authorised professional
  • The pump may be used by children aged 8 years and above as well as persons with reduced physical, sensory or mental abilities or those who lack skills, experience and knowledge only if they are supervised. These aforementioned persons should only use the appliance while adhering to safe instructions and resulting dangers.
  • Cleaning and maintenance must not be carried out by children without supervision.
  • Under certain circumstance’s, it is possible that that contamination of water is caused by leakage.

THE MANUFACTURER EXPLAINS:

  • To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this book.
  • To reject every responsibility for the damages which originate from the improper use of the pump.

SERVICING

It must be regularly checked the pump filter and clean if necessary. The service intervals are based on the respective usage. We recommend a weekly control in much dirt accumulation, if necessary daily inspection. Under normal pumping conditions the pump requires no servicing.

With abrasive materials like sand the servicing duration can become shorter.

The following controls should be carried out regularly:

  • Intactness of the electric cable
  • Pre-pressure in the pressure tank (approx. 1.6 – 2.0 bar)
  • Medium temperature max. 90°C
  • That the connection hoses are not bent or broken
  • Cleanness of the pump medium Moreover, the pump should be emptied with risk of frost, be washed out with clear water and stored dry

GUARANTEE REGULATIONS

For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the pump. Shipping costs shall be borne by our company, except as required by law. Please report the warranty on our service platform www.profi- pumpe.de/information.php. We will inform you how to proceed with case-related.

Returns please sufficient postage. Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery. Our service we provide in Germany.

The warranty does not cover:

  • Material wear (sealing rings, impeller wheels, impeller chambers)
  • Unjustified interventions or changes in the pump
  • Damages by selffault
  • Improper servicing and improper use
  • DRY RUNNIG (Also partially!) of the pump
    Moreover, we give no damage compensation for secondary damages!

RECOGNISING AND REPAIRING OF MISTAKES

Problem Possible cause Solution
Pump runs, no wa- ter is being pumped / Highly fluctuating pressure Air in
the suction line Check suction line and connec- tions for vacuum tightness
Air in the system (cannot escape) Air in the system must be let out / Press

RUN key several times for a few minutes
Impeller wheel is blocked| Impeller wheel must be cleaned
Pump does not start or switches itself off| Engine guard has switched the pump off| Pump needs to be cooled
No electricity| Check electrical connections
Pump runs, Pump capacity slows down or stops| Pump does not suck in water| Install pump lower
Hose connections systems have a leak| Check hose connection systems
Impeller wheel is worn down| Change impeller wheel
Filter has become dirty| Clean filter

NOTES ON PRODUCT LIABILITY

We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.

NOTES ON DISPOSAL

Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to be disposed in your household garbage. We are registered at the German registration department EAR under the WEEE-No. DE79535656. This symbol means, that you’re not allowed to treat this product as a regular household waste item – it has to be disposed at a recycling collection point of electrical devices. This is the best way to save and protect our earth. THANK YOU FOR YOUR SUPPORT!

EU DECLARATION OF CONFORMITY

The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the product named overleaf, namely INVERT-TECH 3-550, INVERT-TECH 3-650 as placed on the market, complies with the relevant provisions listed below, the relevant EU harmonised directives and the EU standard for safety. This declaration of conformity applies insofar as no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer.

The sole authorised person to keep the technical documents:
Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich

Machinery Directive (2006/42/EC)
Low Voltage Directive (2014/35/EU)
EC Electromagnetic Compatibility Directive (2014/30/EU)

The following harmonized standards:
EN ISO 12100:2010,
EN 809:1998+A1:2009+AC:2010,
EN 60204-1:2018, EN 60335-1:2012+A13:2017,
EN 60335-2-41:2003+A1:2004+A2:2010,
EN 62233:2008+AC:2008,
EN 60034-1:2010+AC:2010, EN 55014-1:2017,
EN 61000-3-3:2013
RoHS: 2011/65/EU

Signed for and on behalf of:
Amur S.à r.l.
Remich, 10.02.2023

i.V. Dipl. Phys. Peter Neumüller
Technical Manager

INSTALLATION SCHEME 1

Before use, be sure to fill the pump and suction pipe / hose with water!

TECHNICAL DATA

| INVERT- 3-550 HW01116| INVERT- 3-650 HW01116-2
---|---|---
Power| 550 W| 650 W
Voltage| ~230V/ 50Hz| ~230V/ 50Hz
Max. head| 28 m| 46 m
Max. flow| 4,8 m³/h| 4,8 m³/h
Max. speed| 4000 RPM / UPM| 5000 RPM / UPM
Max. Pressure (Pmax.)| 2,8 bar| 4,6 bar
Max. temperature| 90°C| 90°C
Measures in mm| 284,5x170x240| 284,5x170x240
Inlet Connection (A1)| G1| G1
Outlet Connection (A2)| G1| G1
Protection class| IP54| IP54
Fastening Screws (S1)| M8| M8

DIMENSIONS IN MM

FLOW DIAGRAM

SPARE PARTS

Spare part / remark|

No.

|
---|---|---
Suction set 2 (without hose) For technical information see section 15.| A8494 AZ-AS2|
Prefilter 2 liters For technical information see section 15.| A88 P-FA2L|
Prefilter, Cartridge filter For technical information see section 15.| A86 Z-KF|

Other spare parts and accessories, on request.

Please note our disposal advice at section 12.

WE HIGHLY RECOMMEND

THE INVERTER PUMP CONTROLLERS FROM PROFI-PUMPE.DE

This product should not be used with pumps, which have an integrated control system.

Water cooled

  • Automatic demand-oriented switching on and off of pumps
  • ENERGY-SAVING pump operation: Up to 85% energy and cost reduction for pump operation with alternating load
  • Ensures constant water pressure in the pipes
  • Intelligent technology for optimum climate and environmental protection
  • Pressure reducer function: reduces the maximum pump pressure to the set pressure in the piping system
  • Minimizes average noise, quiet pump operation
  • Avoids dangerous pressure surges in the water pipes
  • Signifi cantly increases the service life of the pump and water pipes
  • Reduces the risk of fl ooding due to leaking water pipes
  • Reliable integrated dry run protection with adjustable auto-start
  • built-in check valve
  •  intelligent self-monitoring functions
  • easy commissioning and operation due to preset default values

With an INVERTER pump control from profi -pumpe.de you save over 80% on energy, actively protect the environment and climate and save on electricity costs! In many cases, the purchase is amortized by cost savings in a very short time.

CUSTOMERS SUPPORT

Imprint / Impressum
Amur S.à r.l.
www.amur.lu
Email: info@amur.lu
Tel.: +49 611 9458777-0
Fax: +49 611 9458777-11

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

profi-Pumpe User Manuals

Related Manuals