profi-pumpe 6-800-10 Domestic Water Plant Inverter Instruction Manual

June 12, 2024
profi-Pumpe

profi-pumpe 6-800-10 Domestic Water Plant Inverter
profi-pumpe 6-800-10 Domestic Water Plant Inverter

SAFETY INSTRUCTION AND WARNINGS

Please read the user manual before using the pump
Warning sign
Pull power plug
Warning of electrical voltage

INTRODUCTION

We would like to congratulate you on the purchase of our pump. We appreciate your trust. That‘s why funtional security and operational safety stands by us on first place.

To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the pump. Failure to follow the instructions and safety precautions can result in injury or property damage.
Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them. Please always download the latest version of the user manual of www.profi-pumpe.de under „downloads“. This shall always prevail.

IN GENERAL

The pumps in the catagorie Centrifugal Pumps are developed according to the newest stand of technology, manufactured with much care and go under strict intensive controls.

The pumps were optimised by us in particular for their special demands. Make sure after unpacking the pump that the data given on the type label agree with the included operating instructions. In the case of doubt the pump is not to be used. Transport damages are immediately to be reported to the package distributor and to us in witten form.

RANGES OF APPLICATION

These pumps are made for pumping clear water (free of mud and sand, see technical data)
The pumps are made for the following ranges of application:

  • For rainwater use in house and garden
  • For deep well water supply
  • Pumping water from a brook a stream
  • For automatic irrigation
  • For house water supply / Pressure increase

IMPORTANT!

The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any guarantee is void in case of improper use. They are not suitable for pumping flammable liquids or for use in places where there is danger of an explosion. In continuous operation mode, the lifetime will be shortened accordingly. Never run more than 5 minutes against a closed valve pump.

Never start and stop the pump more than 20 times per hour. When the pump clocks, any claim under warranty is void.
Not suitable for use with solar photovoltaic panels.

OPERATION

The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the cables are not damaged. Check before the installation whether the electrical connections are earthed according to the statutory regulations and are installed. The pump is to be secured through a RCD circuit breaker with release current of 30 mA. is technically correct, so this warranty is void. It must be ensured that the pump is sufficiently cooled during prolonged operation.

It is not recommended to perform even cable extensions or any other technical modifications. The lines to th pump must be installed always steadily rising. A transfer of mechanical loads or vibrations from the pump or to the pump must be eliminated through appropriate actions (use of rubber buffers, braided hoses, line fixation, etc.).

If the suction height is greater than 4m or the suction length is greater than 9m, please make the suction line in 1 1/4“ (approx. 32mm) or 1 1/2“ (approx. 38mm) instead of 25mm. Do not reduce the suction line. Please install at the end of the suction line always a check valve, if necessary with floating inlet (at use of rainwater this is mandatory).

All pipe/hose connections to and from the pump must be sealed (e.g. Teflon tape or sealing cord – no hemp!). We recommend that you implement the suction line „as one piece“ without any interruption in order to prevent and avoid leaks. check valve and test water pipes for leaks by means of a pressure test for at least 24 hours. Is dirt expected in the pump, an effective pre-filter should be installed before the pump inlet. Fill pump and suction pipe/hose with water. Please connect electrically pump with power supply. Start the pump. If necessary, the pump and the suction line must be refilled until a normal continuous operation has been established.

If the pump is used outdoors, it must be protected against direct sunlight (risk of overheating) and rain (risk of short circuit).

INSTALLATION SCHEME

INSTALLATION SCHEME

DISPLAY OPERATION MANUAL

DISPLAY OPERATION MANUAL

NO. Display panel – description
0 On / Off button
1 Lock protection indicator light
2 Over temperature protection indicator light
3 Water shortage protection indicator light
4 Abnormal voltage indicator light
5 Button to Iower the pressure
6 Button to Increase to pressure
7 Display screen

(See page 14, point 12 for light indicator / error code)

PRESSURE ADJUSTMENT

  1. Press or ; the display screen will switch to pressure setting mode and the numbers start blinking.
    Then press or continuously to add or reduce pressure.

  2. After adjusting to required pressure, release the button for 5 seconds to exit the pressure setting mode.

  3. Check the recommended pressure for your pump, which you can set before using the pump. (This can be set as required)

Standard pressure setting:
Invert-Tech 6-400-10: 2,5 bar (25 m)
Invert-Tech 6-600-10: 2,8 bar (28 m)
Invert-Tech 6-800-10: 3,2 bar (32 m)

OVERVIEW OF THE COMPONENTS AND CONNECTIONS

Before opening the cover, please always disconnect the pump from the power supply. Electrical connections may only be made by a specialist. Do not make any electrical connections unless the power is turned off. The pump should be placed on the floor with a 30mA residual current circuit breaker. The electrical connection should correspond to the local Safety Guidelines (VDI). Follow the product information on the pump label and ensure that the specifications match. If the pump blades rotate counterclockwise, disconnect the pump from the power supply and arrange for the phases to be reversed by a specialist.
OVERVIEW OF THE COMPONENTS AND CONNECTIONS
OVERVIEW OF THE COMPONENTS AND CONNECTIONS

NO. Electrical connections – names
1 Pressure sensor plug
2 Blue wire L
3 Brown wire N
4 Pressure sensor interface
5 Flow sensor interface
6 Red wire U
7 Blue wire V
8 Yellow wire W
9 Green yellow wire

SECURITY TIPS

  • It is essential to follow applicable regulations and VDI guidelines on electrical safety.
  • Never run pump dry
  • Pumping inflammable, as well as all other aggressive liquids is prohibited
  • Pay attention to the water temperature max. 90°C
  • Never pull the pump on the electrical cable or pressure hose
  • Avoid cross section narrowing
  • Pay attention to the given particle size
  • During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
  • Test wells for enough flowing water (dry run danger)
  • The pump is to be secured through a RCD circuit breaker with a release current of 30 mA.
  • The electrical connections are always to be carried out by an authorised professional
  • Operation can not be performed by children and young people under 16 and people with intellectual disabilities

THE MANUFACTURER EXPLAINS:

  • To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this book.
  • To reject every responsibility for the damages which originate from the improper use of the pump.

SERVICING

Under normal pumping conditions the pump requires no servicing. From an operating period (with clear water) of approx. 2000 hours the mechanical components should be checked: impeller wheels, chambers, sealing rings etc. on wear and if necessary be changed. After 3000 pumping hours the oil in the chamber should also be changed, if necessary (only with oil-dipped engine types!). Please, only fill it up to 80% and check the sealing rings always for density.
With abrasive materials like sand the servicing duration can become shorter.
The following controls should be carried out regularly:

  • Intactness of the electric cable
  • That the connection hoses are not bent or broken
  • Cleanness of the pump medium
    Moreover, the pump should be emptied with risk of frost, be washed out with clear water and stored dry.

GUARANTEE REGULATIONS / STATUTORY WARRANTY

For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the pump. Shipping costs shall be borne by our company, except as required by law. Please report the warranty on our service platform http://www.profi-pumpe.de/service.php. We will inform you how to proceed with case-related. Returns please sufficient postage. Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery. Our service we provide in Germany.

The warranty does not cover:

  • Material wear (sealing rings, impeller wheels, impeller chambers)
  • Unjustified interventions or changes in the pump
  • Damages by self fault
  • Improper servicing and improper use
  • DRY RUNNING (Also partially!) of the pump
    Moreover, we give no damage compensation for secondary damages!
RECOGNISING AND REPAIRING OF MISTAKES
LIGHT INDICATOR PROBLEM REASON SOLUTION
Abnormal voltage protection Input voltage is abnormal Check whether the

circuit voltage is between 180V-260V. If not, install a voltage stabilizer
| Overload / Overheating protection| Pump overload has occurred| Voltage is too low or too high. Adjust the voltage according to the device
Bad heat dissipation| Check whether the cooling fan fell off or got damaged
Impeller got stuck| Open the pump and remove the debries
Winding stator damaged| Replace the winding stator


Ambient temperature is too high

| ****

Set the ambient temperature below 45°C

| Watershortage protection| Water shortage| Check the water source
Unable self-priming,

Automatic suction is no longer possible

| Check whether the water level is lower than the foot valve
Check whether the suction exceed 8m
Check if the pump is filled with water. If not, refill water into the pump body
Check if the inlet pipe is sealed. Any little leakage will seriously impact suction
Check if the impeller is broken. If yes, replace the impeller
| Lock protection Pump does not run or not running properly.| The impeller is stuck or wedged| Check that the shaft rotates and remove rotates and remove any deposits, by opening the pump if necessary.
Bearing is broken| Replace the bearing

DISPLAY FAULT CODES
Code Fault Code Warning
E10 Impeller Blocking A14 Low voltage
E11 Overvoltage fault A15 High voltage
E12 Inverter Board overheating A16 Pump tacking
E13 Water shortage
E17 Pressure sensor fault
E18 Electricity fault
RECOGNISING AND REPAIRING OF MISTAKES – PUMP
Problem Possible cause Solution
Pump runs, no water is being pumped Air in the suction line Check suction

line and connections for vacuum tightness
Air in the system (cannot escape)| Air in the system must be let out
Impeller wheel is blocked| Impeller wheel must be cleaned
Pump does not start or switches itself off| Engine guard has switched the pump off| Pump needs to be cooled
No electricity| Check electrical connections
Pump runs, Pump capacity slows down or stops| Pump is inserted to deep| Insert pump not so deep
Hose connections systems have a leak| Check hose connection systems
Impeller wheel is worn down| Change impeller wheel
Filter has become dirty| Clean filter
Motor not running| Flow sensor backwater valve stuck| Disassemble the induction nut to clean out any solids or debris

NOTES ON PRODUCT LIABILITY

We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.

NOTES ON DISPOSAL

Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to be disposed in your household garbage. We are registered at the German registration department EAR under the WEEE-No. DE79535656. This symbol means, that you’re not allowed to treat this product as a regular household waste item – it has to be disposed at a recycling collection point of electrical devices.
This is the best way to save and protect our earth.
THANK YOU FOR YOUR SUPPORT!

EU DECLARATION OF CONFORMITY

The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the product named overleaf, namely Invert-TECH 6-400/500/600-10 as placed on the market, complies with the relevant provisions listed below, the relevant EU harmonised directives and the EU standard for safety. This declaration of conformity applies insofar as no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer.
The sole authorised person to keep the technical documents:
Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich
Machinery Directive (2006/42/EC)
Low Voltage Directive (2014/35/EU)
Electromagnetic compatibility directive (2014/30/EU)
The following harmonized standards: EN ISO12100:2010, EN 809:1998+A1:2009+AC:2010, EN 60204-1:2018, EN 60335-1:2012+A13:2017, EN 60335-2-41:2003+A1:2004+A2:2010,EN 62233:2008+AC:2008, EN 60034-1:2010+AC:2010, EN 550141:2017,EN 55104-2:2015,EN 61000-3-2:2014,EN 61000-3-3:2013, RoHS: 2011/65/EU
Signed for and on behalf of:
Amur S.à r.l.
Remich, 11.05.2023

i.V. Dipl. Phys. Peter Neumüller
Technical Manager

TECHNICAL DATA

English| INVERT-TECH

6-400-10

| INVERT-TECH

6-600-10

| INVERT-TECH

6-800-10 (HW01120)

---|---|---|---
Power (P2)| 400 W| 600 W| 800 W
Current| 1,8 A| 2,7 A| 3,6 A
Max. pump capacity| 2,3 m³/h| 3,2 m³/h| 3,5 m³/h
Max. pressure| 3,5 bar| 4,0 bar| 4,5 bar
Max. pump height| 35 m| 40 m| 45 m
Water temperature| 0-90°C| 0-90°C| 0-90°C
Ambient temperature| 0-45°C| 0-45°C| 0-45°C
Max. suction height| 8m| 8m| 8m
Suitable for / Liquid| clean water / sauberes klares Wasser
Protective class| IPX4| IPX4| IPX4
Voltage| ~230V/50 Hz| ~230V/50 Hz| ~230V/50 Hz
Measures in cm| 34,6×25,2×31,3| 34×26,3×33| 34x26x33
Weight| 12 kg| 15,4 kg| 16,3 kg
Connection in/out| 1” IG| 1” IG| 1” IG
Cable length| 1,5m| 1,5m| 1,5m

TECHNICAL DATA

| A| B| C| D| E| F| G| H| I
---|---|---|---|---|---|---|---|---|---
INVERT-TECH

6-400-10

| 184mm| 99mm| 42mm| 164mm| 120mm| 159mm| 208mm| 261mm| 251mm
INVERT-TECH

6-600-10

| 188mm| 103mm| 45mm| 190mm| 148mm| 177mm| 232mm| 290mm| 275mm
INVERT-TECH

6-800-10

| 188mm| 103mm| 45mm| 190mm| 148mm| 177mm| 232mm| 290mm| 275mm

WE HIGHLY RECOMMEND THE INVERTER PUMP CONTROLLERS FROM [PROFI-

PUMPE.DE](http://PROFI-PUMPE.DE)

This product should not be used with pumps, which have an integrated control system.
Water cooled

  • Automatic demand-oriented switching on and off of pumps
  • ENERGY-SAVING pump operation: Up to 85% energy and cost reduction for pump operation with alternating load
  • Ensures constant water pressure in the pipes
  • Intelligent technology for optimum climate and environmental protection
  • Pressure reducer function: reduces the maximum pump pressure to the set pressure in the piping system
  • Minimizes average noise, quiet pump operation
  • Avoids dangerous pressure surges in the water pipes
  • Significantly increases the service life of the pump and water pipes
  • Reduces the risk of flooding due to leaking water pipes
  • Reliable integrated dry run protection with adjustable auto-start
  • built-in check valve
  • intelligent self-monitoring functions
  • easy commissioning and operation due to preset default values

Lables
With an INVERTER pump control from profi -pumpe.de you save over 80% on energy, actively protect the environment and climate and save on electricity costs! In many cases, the purchase is amortized by cost savings in a very short time.
Lables

Imprint

Amur S.à r.l.
www.amur.lu
Email: info@amur.lu
Tel.: +49 611 9458777-0
Fax: +49 611 9458777-11

References