profi-pumpe PSM01143VK Inverter Pump Control 6 Instruction Manual

June 12, 2024
profi-Pumpe

profi-pumpe PSM01143VK Inverter Pump Control 6

profi-pumpe-PSM01143VK-Inverter-Pump-Control-6-product

Product Information

  • Product Name: Inverter Pump Control 6
  • Model Numbers:
    • IPC 6 – 0.75KW / 230V (PSM01142VK)
    • IPC 6 – 1.1KW / 230V (PSM01143VK)
    • IPC 6 – 1.5KW / 230V (PSM01145VK)
    • IPC 6 – 2.2KW / 230V (PSM01146VK)
  • Manufacturer: Profi-Pumpe
  • Website: www.profi-pumpe.de
  • Version: 23.06

Product Usage Instructions

Safety Instructions and Warnings:

  • Please read the user manual before using the device.
  • Always pull the power plug before performing any maintenance or troubleshooting.
  • Warning sign: Be cautious of electrical voltage.

Installation:

  1. The installation must be performed by a qualified professional.
  2. Before using, check that the electrical connections and cables are not damaged.
  3. Ensure that the electrical connections are earthed according to the statutory regulations.
  4. Avoid performing cable extensions as it may void the warranty.

Wiring:
Refer to the wiring diagram and instructions provided for service and technical staff only. The guarantee becomes void if the unit is opened. Follow the below guidelines:

  • Never connect the terminals U, V, W directly to the power supply.
  • Do not connect the AC main circuit power supply and output terminals U, V, W.
  • Perform wiring after the power is cut off.
  • Verify that the inverter rated voltage and the input supply voltage are consistent.
  • Do not perform dielectric voltage withstand test on the inverter.
  • Tighten terminal screws to a torque of 1.7N.m.
  • Ensure the ground terminal is connected before wiring the main circuit terminals.
  • Connect the input power after installing the panel, and do not remove the panel once the power is connected.

Operation – Inverter Pump Control 6:

  1. Check that the rated voltage of the controller matches the input voltage.
  2. Ensure the pressure sensor is connected with the system.
  3. Make sure the product is installed firmly.
  4. Follow the manufacturer’s instructions for pump installation, considering any conditions that must be met before starting up the pump.

INTRODUCTION

We would like to congratulate you on the purchase of our Inverter pump control. We appre-ciate your trust. That‘s why funtional security and operational safety stands by us on first place.

To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the device. Failure to follow the instructions and safety precautions can result in injury or property damage.Please keep the operating manual with the instructions and safety notes in a safe place for future reference. Please always download the latest version of the user manual from www.profi-pumpe. de under „downloads“. This shall always prevail.

IN GENERAL

The inverter pump control is a switching device which can automatically switch an electrical consumer (pump) on and off. The device monitors the pressure and the flow rate in the pressure line. Depending on the pressure or the flow rate, the inverter pump control switches one or more electrical consumers (max. 7.18A for 0,75kw / 10.7A for 1,1kw) on or off. The inverter pump control is to be used exclusively for non-abrasive clear water without deposits and other dirt. In the opposite case, an effective pre-filter with mesh size not coarser than 0.2mm must be installed in front of the unit. After unpacking, make sure that the data indicated on the type plate correspond to the intended operating conditions. In case of doubt, do not operate the unit.Transport damage must be reported immediately to the shipping company and to us in writing.

INSTALLATION

The installation must be performed by a qualified professional.

Please, check each time before using, the electrical connections and the cables are not damaged. Check before the installation whether the electrical connections are earthed according to the statutory regulations and are installed.
Also, it is NOT recommended to perform, for example, a cable extrension. It is not certain whether this modification technically correct, so this warranty is void.

INVERTER – PUMP CONTROL 6, WIRED
0,75 KW 230V / 1230V | 1,1 KW 230V / 1230V | 1,5 KW 230V / 1230V | 2,2 KW 230V / 1230V.

profi-pumpe-PSM01143VK-Inverter-Pump-Control-6-fig-
\(1\)

A non-return valve on the discharge side of the pump is absolutely necessary. We recommend the installation of a 5-way adapter with built-in non-return valve from our product range, wich is available to suit the line cross- section. These 5-way adapters have the possibility of connection for the pressure sensor, as well as for an additional pressure gauge (special accessory, Art.-No. A7257, A7258, A7259, A7260, A7261) We recommend the installation of a pressure gauge so that the line pressure can be checked at any time.

profi-pumpe-PSM01143VK-Inverter-Pump-Control-6-fig-
\(2\)

5 way adapter 1“ with integrated check valve (picture may differ from delivered product). Special accessories, not included in the scope of delivery!

WIRING

Wiring Diagram and Instruction (For service & technical staff only*)

profi-pumpe-PSM01143VK-Inverter-Pump-Control-6-fig-
\(3\)

  1. Never connect the terminals U,V,W directly to the power supply
  2. Don‘t connect the AC main circuit power supply and output terminals U, V, W.
  3. Wiring after the power cut off.
  4. To verify the inverter rated voltage and the input supply voltage are consistent
  5. The inverter can‘t be done the dielectric voltage withstand test.
  6. Terminal screw tightening torque 1.7N.m.
  7. Make sure the ground terminal is connected before wiring the main circuit terminals.
  8. Connect the input power after installing the panel,when the power is connected, don‘t remove the panel

OPERATION

INVERTER PUMP CONTROL 6

Checking before Operation

  1. Check the rated voltage of the controller and the input voltage match.
  2. Check whether the pressure sensor is connected with the system.
  3. Check whether the product is installed firmly
  4. Perform pump installation according to manufacturer‘s instructions. (it is essential to refer to the operating instructions for the pump to find out what conditions must be met before starting up the pump).
Operating Steps
  1. Connect power ,pressure display “00.00”bar, the power indicator lights.
  2. Open the outlet valve, press “RUN” and start the pump.
  3. Any conditions can press “STOP”, and stop the pump.
  4. Press „ “ or „ “, can check the working pressure, if you want to change the pressure press „ “, to increase the setting pressure or press „ “ to reduce the setting pressure.
  5. Open the tap after setting pressure, the inverter will take frequency speed control on pump according to the water using status .Observing whether the pump is running normally, the pressure showed in the display whether is constant. If it does, the installation and debugging is finished, content to remove the faults and debug it again.

Schematic Diagram| No.| Name or

Function

| Instruction
---|---|---|---
| 1| Start-Button| Starts the pump manually.
2| Stop-Button| Stops the pump manually.

3

| Pressure increase| Pressing once increases the pressure by 0.1 bar. Pressing and holding allows a quick increase up to the desired pressure.

4

| Pressure reduction| Pressing once reduces the pressure by

0.1 bar. Pressing and holding allows rapid reduction to the desired pressure.

5| Power display| It lights up when the power is on.

6

| Pump display| The display flashes quickly when the motor is in speed control. The indicator flashes slowly at constant speed or when there is a lack of water. The light fades during an automatic stop and goes out completely during a manual stop.
7| Group display| Lights up when the multiple pumps are connected.

8

| Water shortage| The indicator lights up when there is a lack of water or air gets into the line / pump. In this condition, the system is restarted in the preset time. The interval time is 8 sec, 1 min, 10 min, 30 min, 1 hr, 2 hr and endless loop.
9| Pressure setting| The indicator lights up when the pressure is set.

10

| Display range for the current pressure| Displays the current pressure in bar.
11| Display of the Pressure setting| Displays the set target pressure in bar. The factory default setting is 3 bar.

Code and Function Instruction
No. Code name Schematic Diagram Instruction
1 Over-Voltage- protection In case of overvoltage, this code is displayed.

If the voltage drops, the device switches back to normal operating mode.
2| Under-Voltage protection| | In case of undervoltage, this code is displayed. If the voltage rises, the device switches back to normal operating mode.
3| Thermal protection| | When the heat sink reaches the max. temperature, this code is displayed. If the temperature drops, the device switches back to normal operating mode.
4| Sensor error| | If the pressure sensor is damaged or disconnected, this code is displayed. After the error has been corrected, the device returns to normal operating mode.
5| Over-pressure protection| | If the line pressure rises above the max. pressure of the sensor, this code is displayed. If the pressure drops, the normal operating mode is restored.
6| Open phase protection| | Self-test for incoming and outgoing power.
7| Overload protection| | If the max. permissible current is exceeded, this code is displa- yed. After troubleshooting, the device returns to normal opera- ting mode.
8| Over-current or short circuit protection| | If problems appear with a short circuit or exceeding the maxi- mum current (pump power too high), this code is displayed.After troubleshooting, the device returns to normal operating mode.

SECURITY TIPS

  • Obey absolutely valid regulations on the electrical security
    • To avoid shocks and fire risks, read and follow closely the following instructions:
    • Always unplug the device from the mains before carrying out any work on it.
    • Be sure that the electric line connecting the device to the mains and the extension leads have a cross-section suitable for pump power and be sure that the electrical connections are far away from any water source.
    • When Flow guard is used for swimming pools, ponds, fountains or humid rooms if is necessary to use an automatic RCD with IDn = 30 mA protection.
    • Do not operate the device permanently in the sun (risk of overheating).
    • Installation only in frost-proof areas without condensation.

Warning:
When the pump stops, the pipes are under pressure consequently we recommend opening a tap to discharge the system before carrying out any work.

  • The electrical connections are always to be carried out by an authorised professional.
  • The device must not be operated by children or persons with reduced physical, sensory or mental capabilities. Persons with insufficient experience and knowledge may only use the device according to instructions or supervision if they have been instructed in the safe use of the device and understand the resulting dangers.
  • Cleaning and maintenance may only be carried out by qualified personnel.

THE MANUFACTURER EXPLAINS:

  • To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this book.
  • To reject every responsibility for the damages which originate from the improper use of the device.

SERVICING

It may happen occasionally that dirt is retained in the internal check valve and this is no longer seals 100%. The first remedy should be always trying to flush the check valve free. This is done, for example, by turning on the garden-side faucet fully so that the pump delivers water at full capacity for about 30 minutes. If the clocking does not disappear afterwards, the adapter must be replaced. Before installing the new device, the pump must always be flushed free as described above. Opening this unit, which has already been pre-wired, is not permitted and always leads to the loss of any warranty claims. In addition, considerable dangers can arise during operation of a cycling pump, so that the pump must not be operated further under any circumstances. The pump must be taken out of service until the equipment is replaced. Abra-sive materials, such as sand, will shorten the maintenance time and equipment life.

The following checks should be carried out regularly:

  • functional test (min. every 3 months)
  • integrity of the power cord
  • Clean the guide lines (e.g. no buckling)
  • Clean the media (no sand, no sludge)

GUARANTEE REGULATIONS/STATUTORY WARRANTY

For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the device. Shipping costs shall be borne by our company, except as required by law. Please report the warranty on our service platform: www.profi-pumpe.de/infor mation.php. We will inform you how to proceed with case-related. Returns please sufficient postage. Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery. We provide our service in Germany.

The warranty does not cover:

  • Improper installation (proper installation, unauthorized persons)
  • Material wear (e.g. seals) or dirt in the unit
  • Unjustified interventions or changes in the device
  • Damages by selffault
  • Improper servicing and improper use

Moreover, we give no damage compensation for secondary damages!

Please note that the max. starting current is given by the design of your pump. It is limited in the inverter to protect the devices. The max. starting current of the pump must be smaller than the max. permissible inverter current. Therefore we cannot guarantee the function of any inverter/pump combination.

RECOGNISING AND REPAIRING OF MISTAKES

Problem Possible cause Solution
The pump permanently switches on and off (Pump clocked) The system has leaks.
Internal check valve may leak Vent system

Check system to dripping pipes/faucets / valves.

Check non-return valve for leaks

The pump will not start| 1. No mains voltage present

2. Too much difference in height between

the device and a customer (taps)

3. The pump is defective

4. Malfunction of the device

| 1. Check the electrical connections

2. Reduce height difference

3. Contact a qualified technician

4. Contact the merchant

The pump will not stop| 1. The system has greater leakages

2. Malfunction of the device

3. Internal check valve is dirty

| 1. Check the system

2. Contact the seller

3. Pump + Rinse machine

NOTES ON PRODUCT LIABILITY
We point out that we are only liable for damages under the Product Liability Act which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.

NOTES ON DISPOSAL
Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to be disposed in your household garbage. We are registered at the German registration department EAR under the WEEE-No. DE79535656.This symbol means, that you’re not allowed to treat this product as a regular household waste item – it has to be disposed at a recycling collection point of electrical de-vices. This is the best way to save and protect our earth.

THANK YOU FOR YOUR SUPPORT!

DECLARATION OF CONFORMITY

EU DECLARATION OF CONFORMITY
The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the product named overleaf, namely Pumpensteuerung 6 / IPC 6 – 0,75KW / IPC 6 – 1,1KW/IPC 6 – 1,5KW / IPC 6 – 2,2KW as placed on the market, complies with the relevant provisions listed below, the relevant EU harmonised directives and the EU standard for safety. This declaration of conformity applies insofar as no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer.

The sole authorised person to keep the technical documents:
Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich

Low Voltage Directive (2014/35/EU)
EC Electromagnetic compatibility directive (2014/30/EU)

The following harmonized standards:

  • EN IEC 61800-3:2018 (IEC 61000-2-1:1990, IEC 61000-2-4:2002,
  • EN 61000-4-2:2018, EN IEC 61000-4-3:2020, EN 61000-4-4:2012,
  • EN 61000-4-6:2014, EN 61000-4-5:2014+A1:2017),
  • EN 61800-5-1:2007+A1:2017+A11:2021,
  • RoHS: 2011/65/EU

Signed for and on behalf of:
Amur S.à r.l.
Remich, 19.06.2023

i.V. Dipl. Phys. Peter Neumüller
Technical Manager

TECHNICAL DATA

profi-pumpe-PSM01143VK-Inverter-Pump-Control-6-fig-
\(17\)

English| 0,75 KW

(PSM01142VK)

| 1,1 KW

(PSM01143VK)

| 1,5 KW

(PSM01145VK)

| 2,2 KW

(PSM01146VK)

---|---|---|---|---
Power Supply| 230V, 50Hz
Input Voltage| 230V
Output Voltage| 1*230V (single-phase)
Input Frequency| 50Hz
Output Frequency| 20-50Hz
Rated current/maximal current| 4,8 A/max. 7.18 A| 7 A /max. 10.7 A| 9,6A /max. 14,4 A| 11,5A / max. 17,25 A
Rated Type| Single-phase pump
Sensor cable| ca. 2,0m
Power supply cable| ca. 1,5m
Pump cable| ca. 0,5m
Pressure Sensor| 24V, 4-20mA (max. 10 bar)
Pressure Sensor range| 1 ~ 9.0 bar


System Configuration requirement

| Must add ≥ 4L pressure tank on the pipe net (inflation pressure = 60% setting).
Max.Temperature| 0 ~ + 40°C


Self-Starting pressure

| The self-starting pressure is always 0.3 bar lower than the set target pressure value.


Setup requirement

| Before the product into use, must ensure reliable grounding measures

  • Name
  • Date
  • Signature
  • Performed service work (as precise and detailed as possible)

WE HIGHLY RECOMMEND THE WATER BOOSTER PUMP FROM PROFI-PUMPE.DE
The inverter water booster pump is not to be used with additional external inverter pump controls

  • for circulating large and small quantities of water (ideal for washing machines and WC operation)
  • Good for the environment & climate and COST-SAVING at the same time
  • Intelligent pump system with many self-control functions
  • Automatic switching on and off of the pump
  • Self-priming after filling the suction pipe
  • Permanent magnetic core motor
  • Excellent efficiency, powerful, up to 80% energy saving
  • Best for rainwater/service water use in house & garden
  • With overvoltage, low-voltage and overheating protection
  • With variable number of revolutions
  • Clear display with LED indicator
  • Quiet operation
  • With integrated pressure tank
  • Precisely adjustable working pressure (set value)
  • Sophisticated precise pressure sensor
  • With intelligent inverter control for constant line pressure
  • Integrated non-return valve (easily accessible)
  • Developed according to the latest state of the art

profi-pumpe-PSM01143VK-Inverter-Pump-Control-6-fig-
\(21\)

With an INVERTER-pump from profi-pumpe.de you save over 80% on energy, actively protect the environment and climate and save on electricity costs! In many cases, the purchase is amortized by cost savings in a very short time.