profi-pumpe NVERT-TEC 600 Centrifugal Pumps Instruction Manual
- June 12, 2024
- profi-Pumpe
Table of Contents
- profi-pumpe NVERT-TEC 600 Centrifugal Pumps
- Product Information
- Product Usage Instructions
- INTRODUCTION
- IN GENERAL
- RANGES OF APPLICATION
- OPERATION
- SECURITY TIPS
- THE MANUFACTURER EXPLAINS:
- SERVICING
- GUARANTEE REGULATIONS / STATUTORY WARRANTY
- RECOGNISING AND REPAIRING OF MISTAKES
- NOTES ON PRODUCT LIABILITY
- NOTES ON DISPOSAL
- EU DECLARATION OF CONFORMITY
- TECHNICAL DATA
- ABOUT COMPANY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
profi-pumpe NVERT-TEC 600 Centrifugal Pumps
Product Information
The product is a range of jet, centrifugal, and multistage pumps. It is available in three models: INVERT-TEC 600 (KP01103), INVERT-TEC 1200 (KP01104), and INVERT-TEC 1300 (P-AT130). The pumps are designed for pumping clear water, free of mud and sand, and can be used for various applications such as filling and emptying rain tanks and containers, water re-circulation, rainwater use in house and garden, pumping water from a brook or stream, use in a pond, and others. The pumps come with operational safety and functional security as top priorities.
Product Usage Instructions
- Ensure that the water being pumped is clear and free of mud and sand, as specified in the technical data.
- Choose the appropriate model of the pump based on your requirements (INVERT-TEC 600, INVERT-TEC 1200, or INVERT-TEC 1300).
- Before operating the pump, check the suction line and connections for vacuum tightness.
- If there is air in the system that cannot escape, release the air to ensure proper operation.
- If the impeller wheel is blocked, clean it before starting the pump.
- Make sure the engine guard has not switched off the pump due to any issues. Check electrical connections and ensure there is electricity supply.
- If the pump capacity slows down or stops, check if it has been inserted too deep. Adjust the pump depth accordingly.
- Inspect hose connection systems for leaks. Repair or replace any faulty connections.
- If the impeller wheel is worn down, it needs to be replaced to restore the pump’s performance.
- Clean the filter regularly to prevent clogging and maintain optimal pump functionality.
- Refer to the user manual for recognizing and repairing other potential mistakes or issues with the pump.
- It is important to note that the manufacturer does not take responsibility for accidents or damages resulting from carelessness or disregard for the instructions provided. Improper use of the pump may void the warranty, and damages caused by material wear, unjustified interventions or changes, self-fault, improper servicing, improper use, or dry running of the pump are not covered under warranty. Additionally, the manufacturer does not provide damage compensation for secondary damages.
- For further information and country-specific regulations, please refer to the latest product information available online. Disposal of the product should be done in accordance with applicable regulations.
- Please consult the EU Declaration of Conformity for specific details regarding compliance with relevant directives and harmonized standards for each pump model.
INTRODUCTION
We would like to congratulate you on the purchase of our pump. We appreciate your trust. That‘s why funtional security and operational safety stands by us on first place.
- To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the pump. Failure to follow the instructions and safety precautions can result in injury or property damage.
- Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them. Please always download the latest version of the user manual of www.profi-pumpe.de under „downloads“. This shall always prevail.
IN GENERAL
- The pumps in the catagorie Centrifugal Pumps are developed according to the newest stand of technology, manufactured with much care and go under strict intensive controls.
- The pumps were optimised by us in particular for their special demands. Make sure after unpacking the pump that the data given on the type label agree with the included operating instructions. In the case of doubt the pump is not to be used. Transport damages are immediately to be reported to the package distributor and to us in witten form.
RANGES OF APPLICATION
- These pumps are made for pumping clear water (free of mud and sand, see technical data)
- The pumps are made for the following ranges of application:
- Filling and emptying rain tanks and containers
- For water re-circulation
- For rainwater use in house and garden
- Pumping water from a brook a stream
- Use in a pond
- Others
IMPORTANT!
- The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any guarantee is void in case of improper use. They are not suitable for pumping flammable liquids or for use in places where there is danger of an explosion.
- This pump is intended for private use in the home and garden. These pumps are not designed for continuous use (without interruptions). In continuous operation mode, the lifetime will be shortened accordingly. Never run more than 5 minutes against a closed valve pump. Save the pump against dry running (install dry run protection).
- Never start and stop the pump more than 20 times per hour. When the pump clocks, any claim under warranty is void.
- Not suitable for use with solar photovoltaic panels.
OPERATION
The installation must be performed by a qualified professional.
- Please, check each time before using, the electrical connections and the cables are not damaged. Check before the installation whether the electrical connections are earthed according to the statutory regulations and are installed. The pump is to be secured through a RCD circuit breaker with release current of 30 mA. is technically correct, so this warranty is void. It must be ensured that the pump is sufficiently cooled during prolonged operation.
- It is not recommended to perform even cable extensions or any other technical modifications. The lines to the pump must be installed always steadily rising. A transfer of mechanical loads or vibrations from the pump or to the pump must be eliminated through appropriate actions (use of rubber buffers, braided hoses, line fixation, etc.).
- Do not reduce the suction line. Please install at the end of the suction line always a check valve, if necessary with floating inlet (at use of rainwater this is mandatory) . All pipe/hose connections to and from the pump must be sealed. We re-commend that you implement the suction line „as one piece“ without any interruption in order to prevent and avoid leaks. Check valve and water pipes for leaks at least by pressure testing. during min. 24h. test.
- Is dirt expected in the pump, an effective pre-filter should be installed before the pump inlet. Fill pump and suction pipe/hose with water. Please connect electrically pump with power supply. Start the pump. If necessary, the pump and the suction line must be refilled until a normal continuous operation has been established.
SECURITY TIPS
- Obey absolutely valid regulations on the electrical security
- Never run pump dry
- Pumping inflammable, as well as all other aggressive liquids is prohibited
- Pay attention to the medium temperature max. 35°C
- Never pull the pump on the electrical cable or pressure hose
- Avoid cross section narrowing
- Pay attention to the given particle size
- During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
- Test wells for enough flowing water (dry run danger)
- The pump is to be secured through a RCD circuit breaker with a release current of 30/300mA*.
- The electrical connections are always to be carried out by an authorised professional
- Operation can not be performed by children and young people under 16 and people with intellectual disabilities
THE MANUFACTURER EXPLAINS:
- To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this book.
- To reject every responsibility for the damages which originate from the improper use of the pump.
SERVICING
- Under normal pumping conditions the pump requires no servicing. From an operating period (with clear water) of approx. 2000 hours the mechanical components should be checked: impeller wheels, chambers, sealing rings etc. on wear and if necessary be changed. After 3000 pumping hours the oil in the chamber should also be changed, if necessary (only with oil-dipped engine types!). Please, only fill it up to 80% and check the sealing rings always for density.
- With abrasive materials like sand the servicing duration can become shorter.
- The following controls should be carried out regularly:
- Intactness of the electric cable
- That the connection hoses are not bent or broken
- Cleanness of the pump medium
Moreover, the pump should be emptied with risk of frost, be washed out with clear water and stored dry.
GUARANTEE REGULATIONS / STATUTORY WARRANTY
For all manufacturing and material defects, the statutory warranty applies. In
these cases we take the replacement or repair of the pump. Shipping costs
shall be borne by our company, except as required by law. Please report the
warranty on our service platform http://www.profi-pumpe.de/service.php. We
will inform you how to proceed with case-related. Returns please sufficient
postage. Unfortunately not prepaid returns can not be accepted because they
are filtered out before delivery. Our service we provide in Germany.
The warranty does not cover:
- Material wear (sealing rings, impeller wheels, impeller chambers)
- Unjustified interventions or changes in the pump
- Damages by selffault
- Improper servicing and improper use
- DRY RUNNIG (Also partially!) of the pump
Moreover, we give no damage compensation for secondary damages!
RECOGNISING AND REPAIRING OF MISTAKES
Problem | Possible cause | Solution |
---|---|---|
Pump runs, no water is being pumped | Air in the suction line | Check suction |
line and connections for vacuum tightness
Air in the system (cannot escape)| Air in the system must be let out
Impeller wheel is blocked| Impeller wheel must be cleaned
Pump does not start or switches itself off| Engine guard has switched the pump
off| Pump needs to be cooled
No electricity| Check electrical connections
Pump runs, Pump capacity slows
down or stops
| Pump is inserted to deep| Insert pump not so deep
Hose connections systems have
a leak
| Check hose connection systems
Impeller wheel is worn down| Change impeller wheel
Filter has become dirty| Clean filter
NOTES ON PRODUCT LIABILITY
We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.
NOTES ON DISPOSAL
Electro devices of our company, labeled with the symbol of the crossed trash
bin, are not permitted to be disposed in your household garbage. We are
registered at the German registration department EAR under the WEEE-No.
DE79535656. This symbol means, that you’re not allowed to treat this product
as a regular household waste item – it has to be disposed at a recycling
collection point of electrical devices. This is the best way to save and
protect our earth.
THANK YOU FOR YOUR SUPPORT!
EU DECLARATION OF CONFORMITY
TECHNICAL DATA
English | INNO-TEC 600 | INNO-TEC 1200 | INNO-TEC 1300 |
---|---|---|---|
Power (P1) | 600 W | 1200 W | 1300 W |
**Max. pump capacity*** | 3 m³/h | 3,8 m³/h | 5,4 m³/h |
Max. pressure | 3,5 bar | 4,8 bar | 5,6 bar |
Max. pump height | 35 m | 48 m | 56 m |
Max. water temperature | 35°C | 35°C | 35°C |
Max. suction height | 6m** | 8m** | 8m** |
Protective class | IP44 | IP44 | IP44 |
Tension | ~230V/50 Hz | ~230V/50 Hz | ~230V/50 Hz |
Measures in cm | 37x21x26 | 37x21x26 | 46x22x26 |
Weight | ca. 8 kg | ca. 12 kg | ca. 16 kg |
Connection in/out | 1” IG | 1” IG | 1” IG |
Cable length | 1,2 m | 1,2 m | 1,2 m |
- 1 m³/h = 16,667 l/min
- depending on installing conditions
ABOUT COMPANY
- Amur S.à r.l.
- www.amur.lu
- Email: info@amur.lu
- Tel.: +49 611 9458777-0
- Fax: +49 611 9458777-11
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>