profi-pumpe HAUSWASSERWERK Inverter Automatic Water Booster Pump User Manual

June 12, 2024
profi-Pumpe

profi-pumpe HAUSWASSERWERK Inverter Automatic Water Booster Pump User

Manual

INTRODUCTION

We would like to congratulate you on the purchase of our pump. We appreciate your trust.
That‘s why funtional security and operational safety stands by us on first place.

To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the pump. Failure to follow the instructions and safety precautions can result in injury or property damage.

Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them. Please always download the latest version of the user manual of www.profi-pumpe.de under „downloads“. This shall always prevail.

IN GENERAL

The pumps in the catagorie Centrifugal Pumps are developed according to the newest stand of technology, manufactured with much care and go under strict intensive controls.
The pumps have been optimized by us especially for the special requirements for circulating and filtering large volumes of water. Make sure after unpacking the pump that the data given on the type label agree with the included operating instructions. In the case of doubt the pump is not to be used. Transport damages are immediately to be reported to the package distributor and to us in witten form

RANGES OF APPLICATION

These pumps are made for pumping clear water (free of mud and sand, see technical data)
The pumps are made for the following ranges of application:

  • In private and in public swimming pool
  • Circulating large volumes of water
  • Other Clear water pumping

IMPORTANT!

The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any guarantee is void in case of improper use. They are not suitable for pumping flammable liquids or for use in places where there is danger of an explosion. These pumps are intended for private use in the home and garden. These pumps are not designed for continuous use (without interruptions). In continuous operation mode, the lifetime will be shortened accordingly. Never run more than 5 minutes against a closed valve pump. Save the pump against dry running (in- stall dry run protection).

Never start and stop the pump more than 20 times per hour. When the pump

clocks, any claim under warranty is void.

Not suitable for use with solar photovoltaic panels.

INSTALLATION

The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the cables are not damaged. Check before the installation whether the electrical connections are earthed according to the statutory regulations and are installed. The pump is to be secured through a RCD circuit breaker with release current of 30 mA. is technically correct,
so this warranty is void. It must be ensured that the pump is sufficiently cooled during
prolonged operation.

It is NOT recommended to perform even cable extensions or any other

technical modifications. The lines to the pump must be installed always steadily rising. A transfer of mechanical loads or vibrations from the pump or to the pump must be eliminated through appropriate actions (use of rubber buffers, braided hoses, line fixation, etc.). If the suction height is greater than 4m or the suction length is greater than 9m, please make the suction line in 1 1/4“ (approx.

32mm) or 1 1/2“ (approx. 38mm) instead of 25mm. Do not reduce the suction line. All pipe/ hose connections to and from the pump must be sealed (e.g. Teflon tape or sealing cord – no hemp! ). Do not reduce the suction line. All pipe/hose connections to and from the pump must be sealed. We recommend that you implement the suction line „as one piece“ without any interruption in order to prevent and avoid leaks. Check pump and water lines for leaks by pressure testing min. 24 hours. Is dirt expected in the pump, an effective pre-filter should be installed before the pump inlet. Fill pump and suction pipe/hose with water. Please connect electrically pump with power supply. Start the pump. If necessary, the pump and the suction line must be refilled until a normal continuous operation has been established.
NOTE: Please note that a tapering of the pump connections may cause a defect in the pump. Here, the terminal sizes specified should be strictly adhered to. With strong restriction of flowthrough on the pressure side of the pump (for example, due to clogged sand filter) water can come out of the housing.

OPERATION

  • Please remove the cover of the filler neck, fill in as much water as is necessary to allow it to escape from the filler neck, connect the hose sealingly after filling with
  • If the pump is used for self-priming well water, make sure that a non-return valve is installed at the front end of the suction
  • Connect the power supply, the display shows „0.0“ bar and the indicator light is
  • Pump works Then open the outlet valve in order to remove air from pipes.
  • Start and stop the pump by press the button „“ at any operation
  • By pressing the “ “ or “ “ key, the setpoint value of the working pressure can be set; a short press of the “   “ key increases the pressure by 1 bar each time. A short press of the “                    “ button reduces the pressure by 0.1 bar each, holding the buttons causes the pressure to rise or fall quickly.
  • Open the tap after setting pressu- re, the inverter will take frequency speed control on pump according to the water using status .Observing whether the pump is running normal- ly ,the pressure showed in the dis- play whether is If this is the case, the installation is complete. If you notice any irregularities, please read the point 10.

RECOGNISING AND REPAIRING OF MISTAKES.

BUTTONS AND FUNCTIONAL DISCRIPTION


|  | Key function and display description
---|---|---
NO.| NAME| Description
1| Increase button| Press the button one time can increase 0.1 bar, long time press will increase rapidly.


2

| Pressure display area| Displays the current set of pressure values, unit: bar. The screen flickers after pressing the up and down buttons to set the working pressure.
3| Power indicator light| The light on when the power is connected.


4

| ****

Pump indicator light

| The indicator light flickers rapidly when the motor is in the state of speed regulation and it flickers slowly when the motor works in the constant speed or there is no water. The light will always be on when stops automati- cally. The light will be off when motor stops manually.
5| Pressure setting indicator light| The indicator light will flicker when setting the pressure.


6

| ****

Water shortage indicator light

| Indicator light flickers when there is no water in the pipe. It will automatically restart after water shortage, the restart interval time is 8s, 1min, 10min, 30min, 1h, 2h..2h recycle.


7

| ****

Start/ Stop button

| Press the button to start/stop the pump and to recovery normal state manually when pump is in a state of water shortage.
8| Decrease button| Press the button one time can reduce 0.1 bar, long time press will reduce rapidly.
 | Fault code description
---|---
NO.| Name of code| Code| Fault cause
1| Over-voltage Protection| oU| This code appears when the voltage is higher than 270V and disappears when the voltage is lower than 260V.
2| Low-voltage Protection| LU| This code appears when the voltage is lower than 80V and disappears when the voltage is higher than 90V.
3| Overtemperature Protection| oC| This code appears when the temperature is higher than 80 °C and disappears when the temperature is lower than 60 °C.
4| Sensor Error| oS| This code appears when the pressure sensor is damaged or disconnected and it should be troubleshooting manually.
5| Overpressure Protection| oCP| This code appears when the pipeline pressure equals 99% range of pressure sensor and it should be troubleshooting manually.
6| Overload Protection| oLP| This code appears when the current or the power is overloaded and it should be troubleshooting manually.
 | Fault code description
---|---
NO.| Name of code| Code| Fault cause
7| Overcurrent/Short Circuit Protection| oLP| This code appears when the motor is overcurrent/short circuit and it should be troubleshooting manually.
8| Communication Failure Protection| EAA| This code appears when the communication failure occurred between drive board and control board and it should be troubleshooting manually.
9| Locked-rotor Protection| EH| This code appears when the rotor is locked and it should be troubleshooting manually.
10| Lost Phase Protection| EP| This code appears when phase is lost and it should be troubleshooting manually.


11

| ****

Leakage Protection

| ****

LL

| When the pump runs continuously for 4 hours, it automatically enters the protection program. After eliminating leakage or confirming that it works properly, it can be restarted by changing parameters or power off.

SECURITY TIPS

  • Obey absolutely valid regulations on the electrical security
  • Never run pump dry
  • Pumping inflammable, as well as all other aggressive liquids is prohibited
  • Pay attention to the medium temperature 35°C
  • Never pull the pump on the electrical cable or pressure hose
  • Avoid cross section narrowing
  • Pay attention to the given particle size
  • During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
  • Test wells for enough flowing water (dry run danger)
  • The pump is to be secured through a RCD circuit breaker with a release current of 30
  • The electrical connections are always to be carried out by an authorised professional
  • The pump may be used by children aged 8 years and above as well as persons with reduced physical, sensory or mental abilities or those who lack skills, experience and knowledge only if they are supervised. These aforementioned persons should only use the appliance while adhering to safe instructions and resulting
  • Cleaning and maintenance must not be carried out by children without
  • Under certain cirumstances, it is possible that that contamination of water is caused by

THE MANUFACTURER EXPLAINS:

  • To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this
  • To reject every responsibility for the damages which originate from the improper use of the

SERVICING

It must be regularly checked the pump filter and clean if necessary. The service inter- vals are based on the respective usage. We recommend a weekly control in much dirt accumulation, if necessary daily inspection. Under normal pumping conditions the pump requires no servicing. From an operating period (with clear water) of approx. 2000 hours the mechanical components should be checked: impeller wheels, chambers, sealing rings etc. on wear and if necessary be changed. After 3000 pumping hours the oil inthe chamber should also be changed, if necessary (only with oil-dipped engine types!).
Please, only fill it up to 80% and check the sealing rings always for density. With abrasive materials like sand the servicing duration can become shorter. The following controls should be carried out regularly:

  • Intactness of the electric cable
  • That the connection hoses are not bent or broken
  • Cleanness of the pump medium

Moreover, the pump should be emptied with risk of frost, be washed out with clear water and stored dry.

GUARANTEE REGULATIONS / STATUTORY WARRANTY

For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the pump. Shipping costs shall be borne by our company, except as required by law. Please report the warranty on our service platfrom
www.profi-pumpe.de/information.php. We will inform you how to proceed with case-related. Returns please sufficient postage. Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery. Our service we provide in Germany.

The warranty does not cover:

  • Material wear (sealing rings, impeller wheels, impeller chambers)
  • Unjustified interventions or changes in the pump
  • Damages by selffault
  • Improper servicing and improper use
  • DRY RUNNIG (Also partially!) of the pump

Moreover, we give no damage compensation for secondary damages!

Problem Possible cause Solution

Pump runs, no wa- ter is being pumped

/ Highly fluctuating

pressure

| Air in the suction line| Check suction line and connec- tions for vacuum tightness


Air in the system (cannot escape)

| Air in the system must be let out / Press RUN key several times for a few minutes
Impeller wheel is blocked| Impeller wheel must be cleaned


Pump does not start

or switches itself off

| Engine guard has switched the

pump off

| Pump needs to be cooled


No electricity

| ****

Check electrical connections



Pump runs, Pump capacity slows down or stops

| Pump does not suck in water| Install pump lower
Hose connections systems have a leak| Check hose connection systems
Impeller wheel is worn down| Change impeller wheel
Filter has become dirty| Clean filter

 NOTES ON PRODUCT LIABILITY

We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.

NOTES ON DISPOSAL

Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to be disposed in your household garbage. We are registered at the German registration department EAR under the WEEE-No. DE79535656.

This symbol means, that you’re not allowed to treat this product as a regular household waste item – it has to be disposed at a recycling collection point of electrical devices. This is the best way to save and protect our earth.

THANK YOU FOR YOUR SUPPORT!

EU DECLARATION OF CONFORMITY

The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the product named overleaf, namely INVERT-TECH 1 as placed on the market, complies with the relevant provisions listed below, the relevant EU harmonised directives and the EU standard for safety. This declaration of conformity applies insofar as no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer.
The sole authorised person to keep the technical documents:
Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich

Machinery Directive (2006/42/EC) Low Voltage Directive (2014/35/EU)

EC Electromagnetic compatibility directive (2014/30/EU
The following harmonized standards:
EN ISO 12100:2010; EN 809:1998+A1:2009+AC:2010; EN 60204-1:2018; EN 60335-1:2012+A13:2017;
EN 60335-2-41:2003+A1:2004+A2:2010;
EN 62233:2008+AC:2008; EN 60034-1:2010+AC:2010; EN 55014-1:2017; EN 55014-2:2015; EN 61000-3-2:2014;
EN 61000-3-3:2013 RoHS: 2011/65/EU
Signed for and on behalf of:
Amur S.à r.l.
Remich, 21.02.2023

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

profi-Pumpe User Manuals

Related Manuals