INTRODUCTION

We would like to congratulate you on the purchase of our pump. We appreciate your trust. That‘s why funtional security and operational safety stands by us on first place.
To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the pump. Failure to follow the instructions and safety precautions can result in injury or property damage.
Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them. Please always download the latest version of the user manual of www. profi- pumpe.de under „downloads“. This shall always prevail.

IN GENERAL

The pumps in the catagorie Centrifugal Pumps are developed according to the newest stand of technology,manufactured with much care and go under strict intensive controls.
The pumps were optimised by us in particular for their special demands. Make sure after unpacking the pump that the data given on the type label agree with the included operating instructions. In the case of doubt the pump is not to be used. Transport damages are immediately to be reported to the package distributor and to us in witten form.

RANGES OF APPLICATION

These pumps are made for pumping clear water (free of mud and sand, see technical data)

The pumps are made for the following ranges of application:

  • For rainwater use in house and garden l For deep well water supply
  • Pumping water from a brook a stream l For automatic irrigation
  • For house water supply / Pressure increase

IMPORTANT!

The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any guarantee is void in case of improper use. They are not suitable for pumping flammable liquids or for use in places where there is danger of an explosion. The pumps are designed for home use in the house and garden.
The pumps are designed for continuous operation for professional work. In continuous operation mode, the lifetime will be shortened accordingly. Never run more than 5 minutes against a closed valve pump. Never start and stop the pump more than 20 times per hour. When the pump clocks, any claim under warranty is void.

Not suitable for use with solar photovoltaic panels

OPERATION

The installation must be performed by a qualified professional.

Please, check each time before using, the electrical connections and the cables are not damaged. Check before the installation whether the electrical connections are earthed according to the statutory regulations and are installed. The pump is to be secured through a RCD circuit breaker with release current of 30 mA. is technically correct, so this warranty is void. It must be ensured that the pump is sufficiently cooled during pro- longed operation. If the suction height is greater than 4m or the suction length is more than 9m, please make the suction line 1 1/4 „(about 32mm) or 1 1/2“ (about 38mm) instead of 25mm.It is not recommended to perform even cable extensions or any other technical modifications. The lines to the pump must be installed always steadily rising. A transfer of mechanical loads or vibrations from the pump or to the pump must be eliminated through appropriate actions (use of rubber buffers, braided hoses, line fixation, etc.). If the suction height is greater than 4m or the suction length is greater than 9m, please make the suction line in 1 1/4“ (approx. 32mm) or 1 1/2“ (approx. 38mm) instead of 25mm. Do not reduce the suction line. Please install at the end of the suction line always a check valve, if necessary with floating inlet (at use of rainwater this is mandatory). All pipe/hose connections to and from the pump must be sealed (e.g. Teflon tape or sealing cord – no hemp! ). We recommend that you implement the suction line „as one piece“ without any interruption in order to prevent and avoid leaks. check valve and test water pipes for leaks by means of a pressure test for at least 24 hours. Is dirt expected in the pump, an effective pre-filter should be installed before the pump inlet. Fill pump and suction pipe/hose with water. Please connect electrically pump with power supply. Start the pump. If necessary, the pump and the suction line must be refilled until a normal continuous operation has been established. If the pump is used outdoors, it must be protected against direct sunlight (risk of overheating) and rain (risk of short circuit).

INSTALLATION SCHEME

The diameter of the pipes to be connected should correspond to the pump connections.
Otherwise, additional noise, negative pressure, etc. may occur. The inlet pressure should be at least 0.3 bar lower than the start pressure of the pump

OPERATION MANUAL

After the pump has been properly connected (suction and pressure lines connected, electrical connection establis- hed), the pump should be in the „AUTOMATIC“ operating mode. If this is not the case, press the „AUTO / TANK“ button for longer than 5 seconds until the „AUTOMATIC“ indicator lights up. In this mode, the pump starts automa- tically when the tap is opened. After closing the tap, the pump also stops automatically after approx.15 seconds.

Automatic mode:

The indicator (4) is on. The indicator (2) lights up when water is being pumped. When the tap is half-open, indicators (2) and (3) light up. After closing the water tap, the pump stops automatically after waiting for approx. 15 seconds. The display (3) is „ON“ and the display (2) is „OFF“. After opening the water tap, the line
pressure drops and the display (3) goes out (set target pressure has been undercut), the pump starts automatically and the display (2) lights up. If the water supply to the pump is disturbed (e.g. due to a lack of water), the pump goes into dry-running protection mode. In this case, the displays (2) and (3) are „OFF“. After about 6 minutes of operation, the pump is automatically switched off to prevent pump damage, the display (4) flashes. In dry-running protection mode, the pump checks automatically at time intervals of 1, 5, 6, 8 and 12 hours whether there is enough water, and the pump is switched on for a short time. If there is enough water and the set pressure can be built up, the pump automatically switches back to normal operation. If there is still not enough water in the suction line after 12 hours, the pump is switched off and must be started manually by the customer.

Water tank mode:

This mode is used for filling a water storage tank with the additional protection against water loss or overflow of the tank due to a dripping / leaking floating valve. The pump is connected to the water tank on the pressure side. A mechanical floating valve must be installed in the water tank (p.9 fig.3) and adjusted to the desired maximum water level. We recommend for the tank installation the floating valve with the art. No. A373. To enter water tank mode (fig.4), press button (1) for more than 5 seconds and one of the water tank indicators (5), (6), (7) or (8) will light up. Press button (1) to select the pump‘s operating cycle between 3, 6, 12 and 24 hours.
The pump stops automatically when the water level reaches the maximum float position in the water tank and the water supply in the tank is interrupted by the float valve. Depending on the selected working cycle (5), (6), (7) or (8), the pump will only start up again and fill the water tank after the selected time (3/6/12/24 hrs.) has elapsed. If the pump should be reset to automatic mode, press button (1) for longer than 5 seconds in water tank mode

  Display panel – description
1 Operating mode selection button
2 Water is transported
3 Pressure
4 Automatic mode „ON“
5 Tank mode 3h is selected
6 Tank mode 6h is selected
7 Tank mode 12h is selected
8 Tank mode 24h is selected

SETTING THE ON AND OFF PRESSURE

Set the automatic mode. After opening the tap, the pump should start automatically and stop when the tap is closed. If the pump does not stop within approx. 15 seconds, turn the pressure regulator a little bit counter- clockwise in direction (-) until the pump stops. Open the water tap and check the function several times until the wanted function has been achieved.
If the water tap is closed and the pump starts to cycle, check all lines, tapping points and the non-return valve on the suction side for leaks and eliminate the leaks.
If the pump stops by itself during operation and starts again even though the tap is open, turn the pressure regulator a little bit clockwise in the direction (+) until the pump works without interruption.
The setting of the pressure regulator is located above the fan wheel of the pump (fig.5). The pressure regulator itself is located inside the pump, not accessible from the outside (fig. 6).

SECURITY TIPS

  • Obey absolutely valid regulations on the electrical security
  • Never run pump dry
  • Pumping inflammable, as well as all other aggressive liquids is prohibited
  • Pay attention to the medium temperature 90°C
  • Never pull the pump on the electrical cable or pressure hose
  • Avoid cross section narrowing
  • Pay attention to the given particle size
  • During longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
  • Test wells for enough flowing water (dry run danger)
  • The pump is to be secured through a RCD circuit breaker with a release current of 30
  • The electrical connections are always to be carried out by an authorised professional
  • Operation can not be performed by children and young people under 16 and people with intellectual disabilities

THE MANUFACTURER EXPLAINS:

  • To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to theinstructions in this book.
  • To reject every responsibility for the damages which originate from the improper use of the

SERVICING

Under normal pumping conditions the pump requires no servicing. From an operating period (with clear water) of approx. 2000 hours the mechanical components should be checked: impeller wheels, chambers, sealing rings etc. on wear and if necessary be changed. After 3000 pumping hours the oil in the chamber should also be changed, if necessary (only with oil-dipped engine types!). Please, only fill it up to 80% and check the sealing rings always for density.
With abrasive materials like sand the servicing duration can become shorter.
The following controls should be carried out regularly:

  • Intactness of the electric cable
  • That the connection hoses are not bent or broken
  • Cleanness of the pump medium

Moreover, the pump should be emptied with risk of frost, be washed out with clear water and stored dry.

GUARANTEE REGULATIONS / STATUTORY WARRANTY

For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the pump. Shipping costs shall be borne by our company, except as required by law. Please report the warranty on our service platform http://www.profi- pumpe.de/service.php. We will inform you how to proceed with case-related. Returns please sufficient postage. Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery. Our service we provide in Germany.

The warranty does not cover:

  • Material wear (sealing rings, impeller wheels, impeller chambers)
  • Unjustified interventions or changes in the pump
  • Damages by selffault
  • Improper servicing and improper use
  • DRY RUNNIG (Also partially!) of the pump

Moreover, we give no damage compensation for secondary damages!

**** RECOGNISING AND REPAIRING OF MISTAKES

Problem Possible cause Solution

Pump runs, no water is being pumped

| Air in the suction line| Check suction line and connections for vacuum tightness
Air in the system (cannot escape)| Air in the system must be let out
Impeller wheel is blocked| Impeller wheel must be cleaned


Pump does not start or switches

itself off

| Engine guard has switched the pump off| Pump needs to be cooled
No electricity| Check electrical connections
Check the settings from point 8 and make new settings if necessary.


Pump runs, Pump capacity slows

down or stops

| Pump is inserted to deep| Insert pump not so deep
Hose connections systems have a leak| Check hose connection systems
Impeller wheel is worn down| Change impeller wheel
Filter has become dirty| Clean filter
Problem| Possible cause| Solution
---|---|---
The pump is running, but no lon- ger provides the same pressure / flow rate as when it was new| ****

Dirt has gotten into the pump

| ****

Have the pump and impellers cleaned


The motor shaft only turns with considerable effort.

| ****

After long periods of inactivity, depo- sits have formed on the motor shaft

| Have the pump cleaned, if necessary, lightly grease the motor shaft with acid- free grease in the area of the mechani- cal seal. Change the mechanical seal.
Frequent takeoff during shutdown| Pressure tank has no pressure or is broken| Replace with new pressure tank, and reinsert


Motor not running

| Flow sensor backwater valve stuck| Check check valve and clean/flush if necessary.
Flow sensor broken| Replace flow sensor


PC board broken

| Poor contact of flow sensor| Uncover and tighten signal line
Replace or repair circuit board


Pump stops during operation

| Flow sensor breakage/fault or water shortage| Replace flow sensor or change water

source

NOTES ON PRODUCT LIABILITY

We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.

NOTES ON DISPOSAL

Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to be disposed in your household garbage. We are registered at the German registration department EAR
under the WEEE-No. DE79535656. This symbol means, that you’re not allowed to treat this product as a regular household waste item – it has to be disposed at a recycling collection point of electrical devices. This is the best way to save and protect our earth.

THANK YOU FOR YOUR SUPPORT!

** EU DECLARATION OF CONFORMITY
The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the product named overleaf, namely
HAUSWASSERWERK MIT SENSOR CONTROL 400-10/500-10/600-10** as placed on the market, complies with the relevant provisions listed below, the relevant EU harmonised directives and the EU standard for safety. This declaration of conformity applies insofar as no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer.
The sole authorised person to keep the technical documents:
Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich

Machinery Directive (2006/42/EC) Low Voltage Directive (2014/35/EU)

Electromagnetic compatibility directive (2014/30/EU)

The following harmonized standards: EN ISO12100:2010, EN 809:1998+A1:2009+AC:2010, EN 60204-1:2018, EN 60335-1:2012+A13:2017, EN 60335-2-41:2003+A1:2004+A2:2010,EN 62233:2008+AC:2008,
EN 60034-1:2010+AC:2010, EN 550141:2017,EN 55104-2:2015,EN 61000-3-2:2014,EN 61000-3-3:2013, RoHS: 2011/65/EU Signed for and on behalf

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

profi-Pumpe User Manuals

Related Manuals