ADP 14.5 x 21.5 Premier Evaporator Coil User Guide

June 12, 2024
ADP

ADP 14.5 x 21.5 Premier Evaporator Coil

Product Information

The Premier Evaporator Coil by ADP is a high-quality upgrade for any HVAC system. These coils are specifically designed to provide optimal performance and reliability. They have undergone thorough testing to ensure top-notch quality and are built to deliver consistent ratings. The Premier Evaporator Coil saves installation time and guarantees a leak-free system. It is the perfect solution for various applications.

Features:

  • Built-in plenum flanges with rounded corners for fast and safe installation
  • Available in upflow, downflow, and multi-position configurations
  • Options for AL (Aluminum) and CU (Copper) coil materials to support local markets
  • No cutting required for suction and liquid lines during installation
  • Non-captive front panels for easy coil access without cutting refrigerant lines
  • Cabinet air leakage of 1% or less
  • Improved air quality with mold-resistant building materials
  • Lower height for space-saving opportunities and perfect fit with furnaces

Energy Savings:

Many models of the Premier Evaporator Coil are available to achieve higher SEER (Seasonal Energy Efficiency Ratio) levels, making them compliant with ENERGY STAR requirements. This can make you eligible for utility rebates and federal tax credits, leading to potential energy savings.

Warranty:

The Premier Evaporator Coil comes with a hassle-free 5-year warranty. Additionally, there is an option to register online at www.ADPwarranty.com for an extended 10-year limited warranty.

Product Usage Instructions

Installation:

  1. Ensure that the Premier Evaporator Coil is compatible with your HVAC system.
  2. Follow the manufacturer’s instructions for proper placement and orientation of the coil.
  3. Use the built-in plenum flanges with rounded corners for fast and safe installation.
  4. Select the appropriate configuration (upflow, downflow, or multi-position) based on your system requirements.
  5. Choose the coil material (AL or CU) that suits your local market.
  6. Connect the suction and liquid lines without cutting them.
  7. Securely attach the non-captive front panels for easy access to the coil.
  8. Ensure that the cabinet air leakage is 1% or less.

Maintenance:

  1. Regularly inspect the Premier Evaporator Coil for any signs of damage or leakage.
  2. Clean the coil as recommended by the HVAC system manufacturer to maintain optimal performance.
  3. Monitor and control moisture levels to prevent mold growth on the coil and other surfaces.

Warranty Registration:

To take advantage of the extended 10-year limited warranty, register your Premier Evaporator Coil online at www.ADPwarranty.com. Follow the provided instructions for registration.
Note : For detailed nomenclature information, refer to the product’s Spec Guide.

The Premier Upgrade for Any System

ADP premier evaporator coils match perfectly with your system, providing an upgrade over standard matched coils. ADP coils are thoroughly tested to ensure optimal quality and deliver reliable ratings. They are uniquely designed to save customers time on installation, while ensuring a leak-free system. ADP premier evaporator coils are the perfect solution for your application.ADP-14-5-x-21-5-Premier-Evaporator-Coil-FIG-
\(3\)

Improved Air Quality
Microbes can double every 20 minutes on an untreated surface!

  • Mold is part of our environment and there are no practical ways to completely eliminate mold spores.
  • The best defense against mold in a home is to prevent it from taking hold through moisture control and the use of mold resistant building materials.

Lower Height

ADP provides space saving opportunities and a perfect fit with your furnace!ADP-14-5-x-21-5-Premier-Evaporator-Coil-FIG-
\(5\)

THE ADP ADVANTAGE

  • PROTECTION ADP is the exclusive provider of coils featuring antimicrobial product protection by Microban®, a recognized consumer brand.
  • QUALITY ADP proprietary testing technology ensures leak-free performance at the higher operating pressures of R-410A systems.
  • SERVICE ADP coils are made for seamless installation and easy access.
  • ENERGY SAVINGS Many models are available to achieve higher SEER levels for ENERGY STAR compliance, utility rebates, and federal tax credits.
  • WARRANTY ADP coils come with a no hassle 5-year warranty and feature an available 10-year limited warranty. Simply register online at www.ADPwarranty.com.

NOMENCLATURE

H E30 9 24 C 145 B 12 05 AP
Cabinet Color

Slab No.

| Metering Device| Nominal MBTUH| Cabinet Depth|

Width

| Cabinet Upper Notch| Cabinet Height| Product Code|

Access Port

H: Embossed/| E &A: CU

slab

G: AL slab

| 1: Piston (R-410A)| 18| A: Unc.| Cased

140: 14.0″

142: 14.25″

145: 14.5″

175: 17.5″

210: 21.0″

245: 24.5″

255: 25.5″

Uncased

130: 13.0″

140: 14.0″

155: 15.5″

170: 17.0″

200: 20.0″

205: 20.5″

235: 23.5″

251: 25.12″

| A: Unc.| 00: Unc.| 00 : RH Uncased

01: RH Cased

04: LH Uncased

05: LH Cased

20: RH Cased

multi-pos.

22: LH Cased

multi-pos.

| AP: TXV Access Port
uncased| 9: Non-bleed| 24| C: 20.5″| B: 0.75″| 12: 12.5″
A: Armstrong

D: Ducane/ Aire-Flo

| HP-A/C TXV (R-410A)| 30

36

| D: 21.0″

E: 21.5″

| (cased)| 16: 16.5″

18: 18.5″

G: ICP|  | 42|  |  | (up to 31.5″)
J: Goodman/|  | 48|  |  |
Amana|  | 60|  |  |
N: Nordyne|  |  |  |  |
P: Carrier/|  |  |  |  |
Bryant/|  |  |  |  |
Payne|  |  |  |  |
R: Rheem/|  |  |  |  |
Ruud|  |  |  |  |
T: Trane/|  |  |  |  |
American|  |  |  |  |
Standard|  |  |  |  |
Y: York/|  |  |  |  |
Luxaire/|  |  |  |  |
Coleman|  |  |  |  |

See Spec Guide for additional nomenclature details

ADDITIONAL FEATURES

  • TXV with all threaded connections saves time in the field No brazing required
  • Patented HydroTEC™ low water retention drain pan
    • Dual drain connections on each side for ease of installation
  • Painted cabinet options for furnace color coordination

Proudly distributed by:

2175 West Park Place Boulevard Stone Mountain, Georgia 30087 www.adpnow.com
© by Advanced Distributor Products. All rights reserved. We reserve the right to make changes in specification, at any time, without notice and without liability to purchasers or owners of previously sold equipment.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ADP User Manuals

Related Manuals