ADP HH Series Evaporator Coils User Guide

June 14, 2024
ADP

HH Series Evaporator Coils

Product Information

Specifications

  • Nomenclature : H H57 1 24 A 185 A 21 02 AP
  • Slab Number : Metering Device 1 = Piston (R-410A) 9 = Non Bleed HP-A/C TXV (R-410A)
  • Nominal MBTUH : Cabinet Depth [1] A = 10
  • Cabinet Opening Width [2 ]: 185 = 18 5/8, 225 = 22 5/8, 265 = 26 5/8, 305 = 30 5/8, 365 = 36 5/8, 425 = 42 5/8
  • R-410A Pistons MBTUH Size : 12 = 41, 18 = 49, 24 = 53, 30 = 59, 36 = 67, 42 = 73, 48 = 76, 60 = 93
  • AP : TXV Access Port [3] Product Code: 02 = Cased H
  • Cabinet Opening Height : 21 = 21 1/4, A = Bi-directional airflow [1]

Dimensions

  • Slab Number : H57, Nominal Tonnage: 1.5 – 3
  • Slab Number : H58, Nominal Tonnage: 2 – 4
  • Slab Number : H59, Nominal Tonnage: 2.5 – 4
  • Slab Number : H60, Nominal Tonnage: 3 – 5
  • Slab Number : H61, Nominal Tonnage: 3.5 – 5
  • Slab Number : H62, H66, Nominal Tonnage: 3 – 5

Weight / Pallet Qty

  • Slab Number : H57, Weight (lbs): 36, Pallet Quantity: 6
  • Slab Number : H58, Weight (lbs): 41, Pallet Quantity: 4
  • Slab Number : H59, Weight (lbs): 44, Pallet Quantity: 4
  • Slab Number : H60, Weight (lbs): 50, Pallet Quantity: 4
  • Slab Number : H61, Weight (lbs): 57, Pallet Quantity: 3
  • Slab Number : H62, Weight (lbs): 61, Pallet Quantity: 3
  • Slab Number : H66, Weight (lbs): 75, Pallet Quantity: 3

Airflow Data

Slab Number| 600 CFM| 800 CFM| 1000 CFM| 1200 CFM| 1400 CFM| 1600 CFM| 2000 CFM| 2400 CFM
---|---|---|---|---|---|---|---|---
H57| 0.17| 0.19| 0.22| 0.25| –| –| –| –
H58| –| –| –| –| 0.05| –| –| –
H59| –| –| –| –| –| –| –| –
H60| –| 0.18| 0.20| 0.22| 0.24| 0.26| –| –
H61| –| –| 0.08| 0.11| 0.15| 0.19| 0.23| –
H62| –| –| –| –| –| –| –| –
H66| –| –| –| –| –| –| –| –

Product Usage Instructions

Step 1: Installation
Follow these steps to install the product

  1. Choose the appropriate cabinet opening width based on the dimensions provided.
  2. Ensure the cabinet depth is set to 10, as it is the only selectable option.
  3. Connect the metering device according to the desired configuration (Piston or Non Bleed HP-A/C TXV).
  4. Ensure the supply and return openings are sized correctly based on the formula provided.
  5. Place the product in the desired location and secure it properly.

Step 2: Operation
To operate the product, follow these steps

  1. Turn on the power supply.
  2. Set the desired temperature or mode using the control panel.
  3. Monitor the airflow and adjust the settings if necessary.
  4. Maintain regular maintenance and cleaning to ensure optimal performance.

Step 3: Troubleshooting
If you encounter any issues with the product, refer to the troubleshooting section in the user manual or contact customer support for assistance.

FAQ

  • Q: What are the available cabinet opening widths?
    • A: The available cabinet opening widths are 185 = 18 5/8, 225 = 22 5/8, 265 = 26 5/8, 305 = 30 5/8, 365 = 36 5/8, and 425 = 42 5/8.
  • Q: How do I determine the correct supply and return opening sizes?
    • A: The supply and return opening sizes can be calculated using the provided formula: (A – 1.50) x (B – 4 3/8), where A is the cabinet opening height and B is the cabinet opening width.
  • Q: What is the warranty period for this product?
    • A: Please refer to the warranty information provided in the user manual or contact customer support for details on the warranty period.

HH Series – Features & Nomenclature

Product Features

  • High efficiency lanced fin design.
  • “No-hassle” 5-year warranty. 10 year Limited Warranty available.
  • R-22, R-410A, AC & Heat Pump compatible.
  • All coils have durable packaging with bar coded labels on the box.
  • Threaded expansion valves available factory installed or as a field installed kit.
  • Coils are air pressure tested at 500 psi, leak tested with helium, sealed with rubber plugs, then charged with dry air.
  • Piston options include externally accessible body for easy piston change out and/or TXV installation.
  • Liquid line refrigerant connections are 3/8″ ODF.
  • Suction line refrigerant connections are 7/8″ ODF.
  • Microban® antimicrobial additive to inhibit the growth of mold and mildew in the drain pan.
  • UV resistant drain pans are molded of high temperature (450° F) engineered polymer.
  • Cased coil cabinets are fully lined with 5/8″ foil faced insulation.
  • Non-captive refrigerant lines with long stubs make for easy installation.
  • Copper distributor tube assembly provides brass to brass threads for trouble-free service of TXV.
  • Corrosion resistant coil header plates.

Nomenclature

ADP-HH-Series-Evaporator-Coils- \(1\)

  1. Depth is fixed, 10″ is the only selectable option.
  2. Cabinet opening width is not a selectable option; see dimensions.
  3. Piston will always be sized to match the nominal BTU rating of the coil.

R-410A Pistons

MBTUH| | Size
12| =| 41
18| =| 49
24| =| 53
30| =| 59
36| =| 67
42| =| 73
48| =| 76
60| =| 93

HH Series – Specifications

  • A = Height
  • B = Width
  • C = Depth (excluding flange)
    • Supply Opening: (A – 1.50″) x (B – 4 3/8″)
    • Return Opening : (A – 1.50″) x (B – 4 3/8″)

Weight / Pallet Qty

Slab Num Weight (lbs) Pallet Quantity
H57 36 6
H58 41 4
H59 44 4
H60 50 4
H61 57 3
H62 61 3
H66 75 3

Dimensions

Slab Number| Nominal
Tonnage| Overall| Supply/Return Opening
---|---|---|---
Height [A]| Width [B]| Depth [C]| Height| Width
H57| 1.5 3| 22 3/4″| 23″| 10″| 21 1/4″| 18 5/8″
H58| 2 4| 22 3/4″| 27″| 10″| 21 1/4″| 22 5/8″
H59| 2.5 4| 22 3/4″| 31″| 10″| 21 1/4″| 26 5/8″
H60| 3 5| 22 3/4″| 35″| 10″| 21 1/4″| 30 5/8″
H61| 3.5 5| 22 3/4″| 41″| 10″| 21 1/4″| 36 5/8″
H62, H66| 3 5| 22 3/4″| 47″| 10″| 21 1/4″| 42 5/8″

Airflow Data

Slab Number| Wet Coil Air Pressure Drop (Inches W.C.) by CFM
---|---
600| 800| 1000| 1200| 1400| 1600| 2000| 2400
H57| .17| .19| .22| .25| –| –| –| –
H58| –| .18| .20| .22| .24| .26| –| –
H59| .05| .08| .11| .15| .19| .23| –| –
H60| –| –| –| .17| .18| .23| .27| –
H61| –| –| –| –| .19| .21| .25| –
H62| –| –| –| .15| .17| .19| .23| .27
H66| –| –| .08| .11| .14| .17| .23| .31

  • 2175 West Park Place Boulevard
  • Stone Mountain, GA 30087

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals