ADP HH Series Evaporator Coils User Guide
- June 14, 2024
- ADP
Table of Contents
HH Series Evaporator Coils
Product Information
Specifications
- Nomenclature : H H57 1 24 A 185 A 21 02 AP
- Slab Number : Metering Device 1 = Piston (R-410A) 9 = Non Bleed HP-A/C TXV (R-410A)
- Nominal MBTUH : Cabinet Depth [1] A = 10
- Cabinet Opening Width [2 ]: 185 = 18 5/8, 225 = 22 5/8, 265 = 26 5/8, 305 = 30 5/8, 365 = 36 5/8, 425 = 42 5/8
- R-410A Pistons MBTUH Size : 12 = 41, 18 = 49, 24 = 53, 30 = 59, 36 = 67, 42 = 73, 48 = 76, 60 = 93
- AP : TXV Access Port [3] Product Code: 02 = Cased H
- Cabinet Opening Height : 21 = 21 1/4, A = Bi-directional airflow [1]
Dimensions
- Slab Number : H57, Nominal Tonnage: 1.5 – 3
- Slab Number : H58, Nominal Tonnage: 2 – 4
- Slab Number : H59, Nominal Tonnage: 2.5 – 4
- Slab Number : H60, Nominal Tonnage: 3 – 5
- Slab Number : H61, Nominal Tonnage: 3.5 – 5
- Slab Number : H62, H66, Nominal Tonnage: 3 – 5
Weight / Pallet Qty
- Slab Number : H57, Weight (lbs): 36, Pallet Quantity: 6
- Slab Number : H58, Weight (lbs): 41, Pallet Quantity: 4
- Slab Number : H59, Weight (lbs): 44, Pallet Quantity: 4
- Slab Number : H60, Weight (lbs): 50, Pallet Quantity: 4
- Slab Number : H61, Weight (lbs): 57, Pallet Quantity: 3
- Slab Number : H62, Weight (lbs): 61, Pallet Quantity: 3
- Slab Number : H66, Weight (lbs): 75, Pallet Quantity: 3
Airflow Data
Slab Number| 600 CFM| 800 CFM| 1000 CFM| 1200 CFM| 1400 CFM| 1600 CFM| 2000
CFM| 2400 CFM
---|---|---|---|---|---|---|---|---
H57| 0.17| 0.19| 0.22| 0.25| –| –| –| –
H58| –| –| –| –| 0.05| –| –| –
H59| –| –| –| –| –| –| –| –
H60| –| 0.18| 0.20| 0.22| 0.24| 0.26| –| –
H61| –| –| 0.08| 0.11| 0.15| 0.19| 0.23| –
H62| –| –| –| –| –| –| –| –
H66| –| –| –| –| –| –| –| –
Product Usage Instructions
Step 1: Installation
Follow these steps to install the product
- Choose the appropriate cabinet opening width based on the dimensions provided.
- Ensure the cabinet depth is set to 10, as it is the only selectable option.
- Connect the metering device according to the desired configuration (Piston or Non Bleed HP-A/C TXV).
- Ensure the supply and return openings are sized correctly based on the formula provided.
- Place the product in the desired location and secure it properly.
Step 2: Operation
To operate the product, follow these steps
- Turn on the power supply.
- Set the desired temperature or mode using the control panel.
- Monitor the airflow and adjust the settings if necessary.
- Maintain regular maintenance and cleaning to ensure optimal performance.
Step 3: Troubleshooting
If you encounter any issues with the product, refer to the troubleshooting
section in the user manual or contact customer support for assistance.
FAQ
- Q: What are the available cabinet opening widths?
- A: The available cabinet opening widths are 185 = 18 5/8, 225 = 22 5/8, 265 = 26 5/8, 305 = 30 5/8, 365 = 36 5/8, and 425 = 42 5/8.
- Q: How do I determine the correct supply and return opening sizes?
- A: The supply and return opening sizes can be calculated using the provided formula: (A – 1.50) x (B – 4 3/8), where A is the cabinet opening height and B is the cabinet opening width.
- Q: What is the warranty period for this product?
- A: Please refer to the warranty information provided in the user manual or contact customer support for details on the warranty period.
HH Series – Features & Nomenclature
Product Features
- High efficiency lanced fin design.
- “No-hassle” 5-year warranty. 10 year Limited Warranty available.
- R-22, R-410A, AC & Heat Pump compatible.
- All coils have durable packaging with bar coded labels on the box.
- Threaded expansion valves available factory installed or as a field installed kit.
- Coils are air pressure tested at 500 psi, leak tested with helium, sealed with rubber plugs, then charged with dry air.
- Piston options include externally accessible body for easy piston change out and/or TXV installation.
- Liquid line refrigerant connections are 3/8″ ODF.
- Suction line refrigerant connections are 7/8″ ODF.
- Microban® antimicrobial additive to inhibit the growth of mold and mildew in the drain pan.
- UV resistant drain pans are molded of high temperature (450° F) engineered polymer.
- Cased coil cabinets are fully lined with 5/8″ foil faced insulation.
- Non-captive refrigerant lines with long stubs make for easy installation.
- Copper distributor tube assembly provides brass to brass threads for trouble-free service of TXV.
- Corrosion resistant coil header plates.
Nomenclature
- Depth is fixed, 10″ is the only selectable option.
- Cabinet opening width is not a selectable option; see dimensions.
- Piston will always be sized to match the nominal BTU rating of the coil.
R-410A Pistons
MBTUH| | Size
12| =| 41
18| =| 49
24| =| 53
30| =| 59
36| =| 67
42| =| 73
48| =| 76
60| =| 93
HH Series – Specifications
- A = Height
- B = Width
- C = Depth (excluding flange)
- Supply Opening: (A – 1.50″) x (B – 4 3/8″)
- Return Opening : (A – 1.50″) x (B – 4 3/8″)
Weight / Pallet Qty
Slab Num | Weight (lbs) | Pallet Quantity |
---|---|---|
H57 | 36 | 6 |
H58 | 41 | 4 |
H59 | 44 | 4 |
H60 | 50 | 4 |
H61 | 57 | 3 |
H62 | 61 | 3 |
H66 | 75 | 3 |
Dimensions
Slab Number| Nominal
Tonnage| Overall| Supply/Return Opening
---|---|---|---
Height [A]| Width [B]| Depth [C]| Height|
Width
H57| 1.5 – 3| 22 3/4″| 23″| 10″| 21 1/4″| 18 5/8″
H58| 2 – 4| 22 3/4″| 27″| 10″| 21 1/4″| 22 5/8″
H59| 2.5 – 4| 22 3/4″| 31″| 10″| 21 1/4″| 26 5/8″
H60| 3 – 5| 22 3/4″| 35″| 10″| 21 1/4″| 30 5/8″
H61| 3.5 – 5| 22 3/4″| 41″| 10″| 21 1/4″| 36 5/8″
H62, H66| 3 – 5| 22 3/4″| 47″| 10″| 21 1/4″| 42 5/8″
Airflow Data
Slab Number| Wet Coil Air Pressure Drop
(Inches W.C.) by CFM
---|---
600| 800| 1000| 1200| 1400| 1600| 2000|
2400
H57| .17| .19| .22| .25| –| –| –| –
H58| –| .18| .20| .22| .24| .26| –| –
H59| .05| .08| .11| .15| .19| .23| –| –
H60| –| –| –| .17| .18| .23| .27| –
H61| –| –| –| –| .19| .21| .25| –
H62| –| –| –| .15| .17| .19| .23| .27
H66| –| –| .08| .11| .14| .17| .23| .31
- 2175 West Park Place Boulevard
- Stone Mountain, GA 30087
References
- Residential evaporator coils, air handlers and unit heaters
- Residential evaporator coils, air handlers and unit heaters
- Residential evaporator coils, air handlers and unit heaters