ADP HD Series Premier Horizontal Evaporator Coil User Guide
- June 14, 2024
- ADP
Table of Contents
ADP HD Series Premier Horizontal Evaporator Coil
Product Features
- Rifled copper tubing.
- Lanced fin design.
- Dual 3/4″ FPT condensate drains on front of the coil.
- Refrigerant connections are 3/8″ ODF liquid and 7/8″ ODF suction.
- Non-captive panels allow access to the inside of the cabinet without the need to cut refrigerant lines.
- Optional painted or embossed galvanized steel cabinets.
- Side panel with only six screws for fast and easy coil access.
- UV-resistant drain pans are molded of high-temperature (450 deg. F) engineered polymer.
- Coils are air pressure tested at 500 psi, leak tested with Helium, sealed with rubber plugs and then charged with dry air.
- “No-hassle” 5-year warranty. 10-year Limited Warranty available.
- Threaded expansion valves are available factory-installed or as a field-installed kit.
- Heavy 24 gauge embossed galvanized cabinets fully lined with 5/8″ foil-faced insulation.
- All coils are foam-packed and include bar coding on the label.
- Easy to use filler strip, if coil dimensions are larger than furnace.
- The drain pan has a trough to fully drain condensate away.
- Microban® antimicrobial additive to inhibit the growth of mold and mildew in the drain pan.
Nomenclature
- Piston will always be sized to match the nominal MBTUH rating of the coil.
Dimensions
| Slab *** Number| Nominal**
Tonnage
| Dimensions (in)| Pallet Qty| Weight (lbs)
---|---|---|---|---|---
Height| Length| CU| AL
Core Slabs| (D,P) 12| 2.0 – 3.0| 14.5| 26.5| 8| 50| 40
(D,P) 13| 2.5 – 3.5| 17.5| 21.5| 8| 50| 40
(D,P) 14| 2.5 – 4.0| 17.5| 26.5| 8| 50| 40
(D,P) 15| 3.0 – 4.0| 17.5| 26.5| 8| 56| 45
(D,P) 16| 3.0 – 5.0| 21| 26.5| 4| 61| 49
(D,P) 17| 3.5 – 5.0| 21| 26.5| 4| 64| 52
(D,P) 19| 3.5 – 5.0| 21| 26.5| 4| 60| 48
(D,P) 21| 1.5 – 3.0| 14.5| 31.5| 4| 55| 43
(D,P) 29| 3.5 – 5.0| 21| 31.5| 2| 64| 52
(D,P) 38| 3.0 – 4.0| 17.5| 31.5| 4| 56| 45
(D,P) 42| 1.5 – 3.0| 14.5| 26.5| 8| 50| 40
(D,P) 44| 1.5 – 3.0| 14.5| 31.5| 4| 58| 47
(D,P) 45| 2.5 – 3.5| 17.5| 26.5| 8| 56| 45
(D,P) 52| 3.5 – 5.0| 21| 31.5| 2| 63| 51
(D,P) 74| 3.0 – 4.0| 21| 21.5| 4| 50| 40
(D,P) 75| 3.0 – 4.0| 21| 21.5| 4| 50| 40
(D,P) 78| 2.0 – 4.0| 17.5| 31.5| 4| 70| 56
Non-Core Slabs| (D,P) 03| 2.0 – 3.0| 14.5| 26.5| 8| 49| 40
(D,P) 04| 2.5 – 3.5| 17.5| 21.5| 8| 45| 36
(D,P) 05| 2.5 – 4.0| 17.5| 26.5| 8| 47| 38
(D,P) 06| 3.0 – 4.0| 17.5| 26.5| 8| 50| 40
(D,P) 07| 3.0 – 5.0| 21| 26.5| 4| 51| 41
(D,P) 11| 1.5 – 2.5| 14.5| 21.5| 8| 50| 40
(D,P) 18| 3.0 – 5.0| 24.5| 26.5| 4| 58| 47
(D,P) 26| 2.0 – 4.0| 17.5| 31.5| 4| 53| 43
(D,P) 27| 3.0 – 5.0| 21| 31.5| 2| 63| 51
(D,P) 47| 3.0 – 4.0| 21| 26.5| 4| 60| 48
(D,P) 50| 3.5 – 5.0| 21| 31.5| 2| 63| 51
(D,P) 57| 3.5 – 4.0| 21| 31.5| 2| 63| 51
(D,P) 72| 2.0 – 3.0| 17.5| 21.5| 8| 53| 43
(D,P) 76| 4.0 – 5.0| 24.5| 21.5| 4| 64| 52
(D,P) 77| 4.0 – 5.0| 24.5| 26.5| 4| 74| 60
(D,P) 79| 3.5 – 5.0| 24.5| 26.5| 4| 75| 60
D = Copper slab; P = Aluminum slab
| Opening Dimensions by Cabinet Height|
---|---|---
Opening Type| 14.5″| 17.5″| 21″| 24.5″
__Supply opening (Height x Width)
Return opening (Height x Width)
| 13″ x 19.75″| 16″ x 19.75″| 19.5″ x 19.75″| 23″ x 19.75″
13.5″ x 20.25″| 16.5″ x 20.25″| 20″ x 20.25″| 23.5″ x 20.25″
Refrigerant Connections
Liquid Line – 3/8″ ODF
Suction Line – 7/8″ ODF
Airflow Data
| Slab
Number
| Nominal
Tonnage
| ^ Air Pressure Drop (in WC) by CFM
---|---|---|---
600| 800| 1000| 1200| 1400| 1600| 1800|
2000
Core Slabs| (D,P) 12| 1.5 – 3.0| 0.11| 0.17| 0.25| 0.35| –| –| –| –
(D,P) 13| 1.5 – 3.5| 0.08| 0.14| 0.20| 0.27| 0.36| –| –| –
(D,P) 14| 2.5 – 4.0| –| –| 0.17| 0.24| 0.32| 0.41| –| –
(D,P) 15| 3.0 – 4.0| –| –| 0.14| 0.20| 0.28| 0.35| –| –
(D,P) 16| 3.0 – 5.0| –| –| –| 0.17| 0.23| 0.29| 0.36| 0.43
(D,P) 17| 3.0 – 5.0| –| –| 0.10| 0.14| 0.19| 0.24| 0.25| 0.36
(D,P) 19| 3.5 – 5.0| –| –| –| –| 0.22| 0.33| 0.41| 0.48
(D,P) 21| 1.5 – 3.0| 0.09| 0.13| 0.20| 0.27| –| –| –| –
(D,P) 29| 3.5 – 5.0| –| –| –| –| 0.12| 0.15| 0.19| 0.23
(D,P) 38| 3.0 – 4.0| –| –| –| 0.18| 0.25| 0.31| –| –
(D,P) 42| 1.5 – 3.0| 0.09| 0.14| 0.20| 0.28| –| –| –| –
(D,P) 44| 1.5 – 3.0| 0.06| 0.10| 0.14| 0.20| –| –| –| –
(D,P) 45| 2.5 – 3.5| –| –| 0.19| 0.27| 0.35| –| –| –
(D,P) 52| 3.5 – 5.0| –| –| 0.12| 0.16| 0.20| 0.26| 0.32| 0.39
(D,P) 74| 3.0 – 4.0| –| –| 0.19| 0.25| 0.33| 0.41| –| –
(D,P) 75| 3.0 – 5.0| –| –| –| 0.20| 0.26| 0.33| –| –
(D,P) 78| 2.0 – 4.0| –| 0.09| 0.12| 0.17| 0.23| 0.30| –| –
Non-Core Slabs| (D,P) 03| 2.0 – 3.0| –| 0.16| 0.25| 0.35| –| –| –| –
(D,P) 04| 2.5 – 3.5| –| –| 0.17| 0.23| 0.34| –| –| –
(D,P) 05| 2.5 – 4.0| –| –| 0.13| 0.19| 0.25| 0.32| –| –
(D,P) 06| 2.5 – 4.0| –| 0.09| 0.13| 0.18| 0.24| 0.27| –| –
(D,P) 07| 3.0 – 5.0| –| –| –| 0.14| 0.19| 0.24| 0.30| 0.35
(D,P) 11| 1.5 – 2.5| 0.15| 0.25| 0.37| –| –| –| –| –
(D,P) 18| 3.0 – 5.0| –| –| –| 0.11| 0.14| 0.18| 0.23| 0.28
(D,P) 26| 2.0 – 4.0| –| 0.08| 0.11| 0.16| 0.21| 0.27| –| –
(D,P) 27| 3.0 – 5.0| –| –| –| 0.11| 0.15| 0.18| 0.23| 0.28
(D,P) 47| 2.0 – 3.0| –| 0.11| 0.16| 0.17| –| –| –| –
(D,P) 50| 3.5 – 5.0| –| –| –| –| 0.16| 0.21| 0.27| 0.33
(D,P) 57| 3.0 – 4.0| –| –| –| 0.14| 0.18| 0.22| –| –
(D,P) 72| 2.0 – 3.0| –| 0.19| 0.27| 0.37| –| –| –| –
(D,P) 76| 3.0 – 5.0| –| –| –| 0.17| 0.22| 0.28| 0.34| 0.40
(D,P) 77| 3.5 – 5.0| –| –| 0.11| 0.14| 0.19| 0.21| 0.27| 0.34
(D,P) 79| 3.5 – 5.0| –| –| –| –| 0.22| 0.28| 0.34| 0.40
- D = Copper slab; P = Aluminum slab
- Air pressure drop data is under dry coil conditions. For wet coil conversion at standard AHRI conditions, use 1.3 multiplier.
CONTACT
- Product improvement is a continuous process at Advanced Distributor Products.
- Therefore, product specifications are subject to change without notice and without obligation on our part.
- Please contact your ADP representative or distributor to verify the details.
- © by Advanced Distributor Products. All rights reserved.
- 2175 West Park Place Blvd., Stone Mountain, GA 30087
- www.adpnow.com.
- 2175 West Park Place Boulevard
- Stone Mountain, GA 30087
References
- Residential evaporator coils, air handlers and unit heaters
- Residential evaporator coils, air handlers and unit heaters
- Residential evaporator coils, air handlers and unit heaters
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>