CE LINK SR1KW8L-SG1 Series Portable Power Station User Manual
- June 12, 2024
- CE-LINK
Table of Contents
- CE LINK SR1KW8L-SG1 Series Portable Power Station
- Product Information
- Parameters
- Product Usage Instructions
- Parameters
- Safety guidelines
- Guideline for users
- FAQs (Frequently Asked Questions)
- Error messages & solutions
- What’s in the box
- Disclaimer
- FCC Statement
- ISED Statement
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CE LINK SR1KW8L-SG1 Series Portable Power Station
Product Information
The product is the S1 W8L-SG1 SE IES, a portable power station with multiple charging options. It has a capacity of Wh and supports Wi-Fi connectivity. The power station has AC output, USB-A and USB-C ports for charging devices, as well as car charging and PV charging capabilities. It features intelligent inversion and an EPS function for emergency power supply.
Parameters
-
Net weight: kg ( lbs)
-
Dimension: mm ( in)
-
AC Output (SR1KW8L-SG1-UK/SR1KW8L-SG1-EU/SR1KW8L-SG1-FR/SR1KW8L-SG1-AU/SR1KW8L-SG1-ZA): pure sine-wave, total W (peak W), – V~ ( Hz/ Hz)
-
AC Output (SR1KW8L-SG1-US): pure sine-wave, total 1800W (peak 3000W), 100-120V~ (50Hz/60Hz)
-
USB-A: x
-
USB-A quick charge: x2
-
USB-C: x
-
Car charger DC5521 output: x2
-
Car charge and DC share power: 5V 2.4A (constant voltage), 12W
Max./output 5V 3A 9V 2A 12V 1.5A (constant voltage), 18W
Max./output 5/9/12/15V 3A 20V 5A (constant voltage),100W
Max./output 12.6V 10A, 126W Max. 12.6V 3A W Max. -
AC input voltage (SR1KW8L-SG1-UK/SR1KW8L-SG1-EU/SR1KW8L-SG1-FR/SR1KW8L-SG1-AU/SR1KW8L-SG1-ZA): – V~ ( Hz/ Hz)
-
AC input power charge only mode: W, A Max.
-
AC input power (bypass mode): 1800W, 10A Max.
-
AC input voltage (SR1KW8L-SG1-US): 100-120V~ (50Hz/60Hz)
-
AC input power charge only mode: 1200W, 15A Max.
-
AC input power (bypass mode): 1800W, 15A Max.
-
Car charging input: V/ V battery supported, A by default
-
PV charge: W, 1 -4 V ADC A Max.
-
Battery: lithium iron phosphate battery (LiFePO )
-
Life cycle: remaining capacity still over % after , cycles
-
Protection type: over temperature protection, low temperature protection, over discharge protection, over charge protection, over load protection, short circuit protection, over current protection
-
Charge temperature:
-
Discharge temperature :
Product Usage Instructions
Use
- Avoid collision, drop, and violent vibration. If severe impact happens, shut down the power supply immediately. Securely fix SR KW L-SG1 during transportation to avoid vibration and impact.
- If SR KW L-SG1 falls into water accidentally, place it in a safe and wide area and keep yourself away from it until it’s dry. Do not use the dried product again. Dispose of it properly according to the user manual.
- When connecting the power station to a refrigerator, it may automatically shut down due to the power fluctuation property of the refrigerator. If connecting to a refrigerator that stores medicine, vaccines, or other valuable items, it is recommended to set the AC output to “Never off” in the APP to ensure continuous power. Pay attention to power consumption.
Discard
If conditions permit, discharge the battery completely before putting SR KW L-SG1 in the specified battery recycling bin. SR KW L-SG1 contains dangerous batteries and must not be discarded in ordinary dust bins. Follow local laws and regulations on battery recycling and disposal.
Parameters
-
General
- Net weight: ~22kg (~48.5lbs)
- Dimension: 432270300mm (1710.611.8in)
- Capacity: 1229Wh
- Wi-Fi: supported
-
Output
-
(SR1KW8L-SG1-UK/SR1KW8L-SG1-EU/SR1KW8L-SG1-FR/SR1KW8L-SG1-AU/SR1KW8L-SG1-ZA)
AC output (×3) pure sine-wave, total 1800W (peak 3000W), 220-240V~ (50Hz/60Hz) -
(SR1KW8L-SG1-US)
AC output (×4)
pure sine-wave, total 1800W (peak 3000W), 100-120V~ (50Hz/60Hz) -
USB-A (x2): 5V -= 2.4A (constant voltage), 12W Max./output
-
USB-A quick charge (x2): 5V -= 3A 9V.-= 2A 12V =1.5A (constant voltage), 18W Max./output
-
USB-C (x2): 5/9/12/15V- 3A 20V..: 5A (constant voltage), 100W Max./output
-
Car charger: 12.6V -=: 10A, 126W Max.
-
DC5521 output (×2): 12.6V.==: 3А
-
-
Car charge and DC5521 share power, 126W Max.
-
Input
- (SR1KW8L-SG1-UK/SR1KW8L-SG1-EU/SR1KW8L-SG1-FR/SRIKW8L-SG1-AU/SR1KW8L-SG1-ZA)
- AC input voltage: 220-240V~ (50Hz/60Hz)
- AC input power (charge only mode): 1200W, 10A Max.
- AC input power (bypass mode): 1800W, 10A Max.
- (SR1KW8L-SG1-US)
- AC input voltage: 100-120V~ (50Hz/60Hz)
- AC input power (charge only mode): 1200W, 15A Max.
- AC input power (bypass mode): 1800W, 15A Max.
- Car charging input: 12V/24V battery supported, 8A by default
- PV charge; 400W, 13-45V – 12A, DC12A Max.
-
Battery
- Cell Type: lithium iron phosphate battery (LiFePO)
- Life cycle: remaining capacity still over 80% after 2,000 cycles
- Protection typ e: over temperature protection, low temperature protection, over discharge protection, over charge protection, over load protection, short circuit protection, over current protection
- Charge temperature: 0~45°C (0~113°F)
- Discharge temperature: -20~45°C (-4~113°F)
*Whether the product can be charged or discharged is subject to the actual battery pack temperature.
Safety guidelines
Use
- Do not let a working SRIKW8L-SG1 be close to the heat source, such as fire or heater.
- Do not make SR1KW8L-SG1 contact with any liquid.
- Do not use SR1KW8L-SGI in a strong electrostatic or strong magnetic field environment.
- Do not disassemble SRIKWL-SG1 in any way or pierce it with a sharp object.
- Do not short SR1KW8L-SG1 by wire or other metal objects.
- Do not use ingenuine parts or accessories. For part or accessory replacement, please visit official sales channel for purchase information.
- When using SR1KW8L-SG1, please follow the operating temperature defined in this user manual strictly. If the temperature is too high, battery may catch fire or even explode. If the temperature is too low, SRIKWSL-SG1 performance will be seriously impaired, even normal use will be impacted.
- Do not stack heavy objects on SRIKW8L-SG1.
- Do not stop the fan by force or expose SR1KW8L-SG1 in an unventilated or dusty environment when it is working.
- Please avoid collision, drop, and violent vibration. If severe impact happens, shut down the power supply immediately. Please fix SRIKW8L-SG1 firmly during transportation to avoid vibration and impact.
- If SRIKW8L-SG1 falls into water accidentally, place it in a safe and wide area, and keep yourself away from it until its dry. Dried product shall not be used again. Dispose it properly according to chapter 2.2 in this user manual. If SR1KWL-SG1 is on fire, please use fire extinguishing equipment in the recommended order: water or water mist, sand, fire blanket, dry powder, dioxide carbon fire extinguisher.
- If there is dirt, use a dry cloth to wipe it.
- Place SRIKW8L-SGI carefully to prevent damage. If SRIKWL-SG1 is tipped over and seriously damaged, turn off SRIKW8L-SG1 immediately and place the battery in a spacious place and keep it away from flammable materials and people, and scrap it in accordance with the requirements of local laws and regulations.
- Keep SR1KW8L-SG1 out of the reach of children and pets.
- Keep SRIKW8L-SGi in a dry and ventilated place.
- In humid environment (seaside, water, etc.), it is recommended to equip SRIKW8L-SG1 with moisture-proof bag. If water is found inside product, do not use/start it again. Please take countermeasures to prevent electric shock before touching SRIKWSL-SG1. Put it in a safe and waterproof open area, and contact customer service immediately.
- It is not recommended to use SRIKW8L-SG1 to supply power for safety-related emergency medical equipment, including but not limited to medical grade breathing machine (hospital version CAP: Continuous Positive Airway Pressure), artificial lung (ECMO, Extracorporal Membrane Oxygenation). It can be used to supply power for home version CAP at home and does not require continuous professional monitoring. Please follow your doctor’s advice and consult the manufacturer for any restrictions on the use of the device. For general medical equipment, please pay attention to the power condition to ensure that power does not run out.
- Power supplies will inevitably generate electromagnetic fields when it is in use, which might affect the implantable medical device or normal operation of personal medical device, such as pacemaker devices, cochlear implants, hearing AIDS, defibrillators, etc. If any of these medical devices are used, please consult the manufacturer about the restrictions on the use to ensure that SRIKW8L-SG1 is operated at a safe distance from implanted medical devices such as pacemakers, cochlear implants, hearing AIDS, defibrillators.
- When the power station is connected to a refrigerator, it may automatically shut down because of the power fluctuation property of the refrigerator. When connecting the power supply to a refrigerator that stores medicine, vaccines or other valuable items, it is recommended to set the AC output to “Never off” in the APP, so as to ensure continuous power. Users should pay attention to power consumption.
Discard
- Conditions permitting, be sure to discharge the battery completely, and then put SR1KWL-SG1 in the specified battery recycling bin. SR1KW8L-SG1 contains batteries, which are dangerous. It is strictly prohibited to discard them in ordinary dust bins. For details, follow local laws and regulations on battery recycling and disposal.
- If the battery cannot be discharged completely due to product failure, do not discard the battery directly in the battery recycling bin. Contact a professional battery recycling company for further disposal.
- The battery will not start after over discharge. Please dispose it as discarded.
Guideline for users
Product overview
LCD screen
Battery capacity: When SR1KW8L-SG1 is being charged, SOC icon will
flicker.
Wi-Fi connection status: The flickering icon indicates that SR1KWL-SG1 is
ready for pairing. The icon will keep flickering if a mobile phone and SR1KWL-
SG1 are connected by hotspot. After network connection succeeds, the icon will
always be on. If connection fails, the icon will be off.
- Please refer to clause 5 for more details regarding error message.
Use
Note: Press and hold the ON/OFF button for 10 seconds to restart the BMS and
clear the fault information.
- On and off
- Press the main power switch to turn on the device, then the screen will be lit and the main power indicator will enter the breathing light mode.
- If no operation is performed to SR1KW8L-SG1 for 5 minutes, SR1KW8L-SG1 will enter hibernation state and the LCD will automatically turn off. When there is load change or operation to SR1KWL-SG1, the LCD screen will be automatically lit. Press the main power switch to turn on or turn off the LCD.
- Press and hold the main power switch will turn off SR1KW8L-SG1.
- The default standby time is 2 hours. If other output power switches are not turned on and not any loads are connected, SR1KWL-SG1 will automatically shut down after 2 hours. Standby time can be set on the APP.
Note: When no AC input, long press the above AC output button, you can switch the AC off-grid output frequency , long press 2s to switch, the AC output icon will flash 3 times after successtul switching.
- AC output
- After the main power is on, press the AC output power switch to enable the AC output port. Press the AC output power switch again to turn it off.
- The default standby time of the AC output is 1 hour. After 1 hour without any loads, the AC output power switch will be automatically off.
- When the AC output is not in use, turn it off to save power consumption.
- 12V DC output
- After the main power switch is turned on, press the 12V DC output power switch to enable the DC output port.
- Press the 12V DC output power switch again to turn it off.
- When the 12V DC output power switch is turned on, SR1KWL-SG1 does not shut down automatically.
AC charging
Quick charging technology is designed for AC charging. You can control the
charging power via the AC charging speed switch. The slow charge mode is on by
default when SR1KWL-SG1 is turned on, and can be switched to quick charge mode
by the button. Quick and slow charging mode switching can also be set by APP.
If the current is continuously higher than 20A, the charging input port will
start the self-protection function, and the charging overload protection
switch will automatically trip. Press the charge overload protection switch to
restore charging after confirming no fault.
Quick charge and slow charge can be switched by the button.
The charging power range can be adjusted by APP.
Please use the standard AC charging Cable for fast charging. AC Charging Cable
should directly plug into 10A (or above) wall-mounted socket. We take no
responsibilities for any damage caused by using unofficial AC charging cable,
and other failures to follow instructions.
PV charging
*Solar charging cable (DC7909)
- Please follow the user manual to connect the solar panels.
- Before connecting the solar panel, check whether its output voltage is within SRIKW8L-SG1 specifications to avoid damage to SR1KW8L-SG1.
Car charging
SRIKW8L-SG1 can be charged by a car charging port. It should be charged after
the car starts, so as to avoid the car battery loss and failure to start. At
the same time, ensure good connection between the car charging port and
cigarette lighter. We take no responsibilities for any loss caused by improper
operation.
Intelligent inversion
To avoid operation faults arising from charging overload, when the total
output power is over the rated output power, the constant output power will be
automatically enabled, so that SRIKW8L-SG1 can supply power to the high power
device at rated output power.
Please take note of the following while using constant power:
- The constant power output function is not enabled by default, which can be turned on or off by App.
- In the following cases, constant power output function is not enabled:
- AC output turned on in charging status (bypass mode).
- Constant power output turned off.
- Constant power output function is more suitable for heater and motor instead of all electrical equipment. It is not suitable for some electrical appliances with voltage protection (such as precision instruments). Constant power output function application is subject to actual testing.
APP
You can control and view information and data about this product by App.
EPS function
This product supports the EPS function. When the grid is connected with
SR1KW8L-SG1 AC input port by AC cable, the output port enables the electrical
appliance to work. In such case, power is from grid instead of battery. When
power grid is off, the power station can switch to battery-supplying mode
within 14mS. Such function is unprofessional EPS, which does not support
switch in OmS, so do not connect it to equipment with strict EPS requirement,
such as data server and workstation or please confirm compatibility after
tests, and suggest only use one device instead of multiple devices at the same
time so as not to cause overload to the power station. We shall not be liable
for abnormal work or data loss arising from operation not following this user
manual.
FAQs (Frequently Asked Questions)
-
What kind of battery is used?
Lithium iron phosphate battery (LiFePO,). -
What equipment can be connected to the AC output ports?
The AC output has high rating power and maximum power, which enables it to supply power to most household appliances. Suggest check the equipment power prior to connecting and make sure power of all equipment lower than rated power. -
How to know the supply time?
Time shows in the LCD, which can be referred to for estimation for equipment with stable power consumption. -
How to know it is charging?
When in charge, the LCD shows remaining charging time. The SOC flickers, and input power is shown. -
How to clean the unit?
Clean the unit with a dry, soft and clean cloth or tissue. -
How to store the unit?
Turn it off, and keep it in a dry and ventilated place. Do not expose it close to water. For long-term storage, suggest discharge to 0% and charge to 100% every 3 months to extend the service life. -
Can it be taken on board?
No.
Error messages & solutions
What’s in the box
Maintenance
- It is recommended to use or store SR1KWL-SG1 under 20-30°C ambient temperature. Keep it away from water, heater and metal parts.
- For long-term storage, charge and discharge every 3 months, i.e. discharge to 0% then charge to 100%.
- For safety, do not store SR1KW8L-SG1 with temperature above 45°C or below -10°C. If the capacity is lower than 1%, please charge to 60%. Long-term storage with serious power shortage will cause irreversible damage to the cell and shorten the service life of the product.
- If the capacity is seriously insufficient and idle time is too long, the product will enter deep sleep mode, and the product can only be used after being charged.
Disclaimer
- The product has a built-in battery management system, which has protections such as overcharge, overdischarge, overcurrent, short circuit, high and low temperature, and abnormal communication. During the use of this product, protection may occur and cause output interruption. Power supply to special equipment, such as medical equipment, server, the indirect loss caused by accidental power failure has nothing to do with the company; all accidents caused by illegal use, self-dismantling, and man-made damage have nothing to do with the company.
- Before using the power station SR1W8L-SGI, please read this user manual to ensure understanding and proper use. After reading the user manual, please keep it well for future reference. Improper operation may cause serious injury to yourself or others, or result in product damage and property loss. Once using SRIKW8L-SG1, you are deemed to have understood and accepted all terms and contents herein. Users promise to be responsible for their actions and all consequences arising therefrom. We shall not be liable for any loss arising from user’s not following this user manual.
- In compliance with laws and regulations, the company reserves the right of final interpretation of this document and all related documents of this product. Subject to update, revision or termination without prior notice, please visit the official website for the latest product information.
FCC Statement
- This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
- Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
- Note:This equipment has been tested and found to comply with the limits for a class B digital device,pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
- This equipment generates uses and can radiate radio frequence energy and,if not installed and used in accordance with the instructions,may cause harmful interference to radio communications.However,there is no guarantee that interference will not occur in a particular installation.if this equipmemt does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an autlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- The device has been evaluated to meet general RF exposure requirement, This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body.
ISED Statement
- This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
- This equipment should be installed and operated with a minumum distance of 20 cm between the radiator and your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>