F F DR-04G Hermetic Motion Sensor Instruction Manual

June 12, 2024
F F

F F DR-04G Hermetic Motion Sensor

Do not dispose of this device in the trash along with other waste!
According to the Law on Waste, electro coming from households free of charge and can give any amount to up to that end point of collection, as well as to store the occasion of the purchase of new equipment (in accordance with the principle of old-for-new, regard-less of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the environment and human health.

Purpose

The motion sensor is used for automatic and temporary swit-ching on of lighting if a person or other object appears in places such as hallways, courtyards, driveways, garages, etc.

Functioning

The sensor detects the infrared radiation sources. It analyzes the parameters such as the size of the object, the amount of heat emitted and the speed of movement between sectors of detec-tion. Movement in the detection area will automatically switch on the lighting. From this moment the light will stay on, as long as the sensor detects continuous movement. Only if there is no movement in the detection area triggers the lighting support time. Another movement in the detection area and its subsequ-ent disappearance in the course of time measurement starts the support time from the beginning. The specific of operation al-lows using the DR-04G as a presence sensor. The motion sensor is equipped with a twilight sensor to prevent switching on the lighting during the day. The detection status and the readiness to switch on the lighting are only activated after dusk. The ac-tivation time of the sensor can be adjusted by the user using a potentiometer. Additionally, it is possible to adjust the switching time of the re-ceiver in the range of 10 s÷15 min.

  • Changes in temperature can affect the motion detec-tion.
  • The motion sensor can work indoors and outdoors in places where it is not exposed to direct rain or snowfall and to the possibility of splashing the sensor housing and its electrical connection points with water or other liquid.
  • Avoid locations with large objects in the detection area such as trees that can be moved by the wind.
  • The minimum distance between the sensor and the light source is 60 cm.
  • If the motion sensor is installed too close to the switched light source, the system may be activated, which means that the sensor will automatically switch on and off the light source. It is necessary to move the sensor to an ap-propriate distance away from the light source.
  • Do not install the sensor in the immediate vicinity of he-ating, air-conditioning and lighting devices.

Settings

The detection area (range)

  • No adjustment Detection range of the sensor is fixed, up to 12 m (parameters specified for the sen-sor mounted at a height of 1,8÷2,5 m).

Switch-on time

The time of the receiver switching on can be adjus-ted within the range of 10 sec to 15 min. Turning the control knob right [+] increases the switching on time, turning left [–] reduces the switching on time.

he sensitivity of the twilight sensor

The sensitivity of the twilight sensor can be adjusted within the range of 3 lx to 2000 lx. Turning the control knob in the direction of the „3” value (min.) will switch the light later, turning it in the direction of the „2000” value (max) – will switch the light earlier. For the sensor to be active throughout the whole day, the control knob should be maximally turned in the direction of the „sun”.

Detection area (ceiling mounting)

The detector head is movable in 2 planes, allowing pre-cise adjustment of the detection field to suit individual user requirements.

Mounting

  1. Disconnect the power supply.
  2. Open the junction box cover.
  3. Pull the connection wires through the rubber grommets on the rear of the sensor junction box.
  4. Connect according to the diagram.
  5. Mount the sensor on the wall with 2 screws.
  6. Set the sensor head to the desired detection area.
  7. Set the sensitivity of the twilight automatic control and the switch-on time.
  8. Switch on the power supply of the sensor.
  • The sensor is inactive for the first 30 seconds after the power supply is switched on. During this time, the PIR system warms up.

Wiring diagram

Dimensions

Technical data

  • power supply 195÷265 V AC
  • maximum load current (AC-1) 5 A
  • twilight activation threshold 3÷2000 lx
  • motion detection 0.6÷1.5 m/s
  • switch-on time 10 s (±3 s)÷15 min. (±2 min.)
  • horizontal detection area 180°
  • vertical detection area 45°
  • max radius of detection (T<24°C) 12 m
  • head rotation range (horizontal) 60°
  • head rotation range (vertical) 180°
  • sensor mounting height 1.8÷2.5 m
  • power consumption standby 0.15 W on 0.5 W
  • terminal 1.5 mm² screw terminals
  • tightening torque 0.3 Nm
  • working temperature -20÷40°C
  • dimensions head folded out horizontally 80×52×120 mm
  • head folded out vertically 80×52×95 mm
  • mounting surface
  • ingress protection IP65

Power table

The above data are indicative and will heavily depend on the design of a specific receiver (that is especially important for LED bulbs, energy-saving lamps, electronic transformers and pulse power supply units), switching frequency and operating conditions. For more information visit: www.fif.com.pl.

Warranty

The F&F products are covered by a warranty of the 24 months from the date of purchase. Effective only with proof of purchase. Contact your dealer or directly with us.

CE declaration

F&F Filipowski L.P. declares that the device is in conformity with the essential requirements of The Low Voltage Directive (LVD) 2014/35/EU and the Electromagnetic Compatibility (EMC) Directive 2014/30/UE. The CE Declaration of Conformity, along with the references to the standards in relation to which conformity is declared, can be found at www.fif.com.pl on the product page.

F&F Filipowski L.P. Konstantynowska 79/81, 95-200 Pabianice, POLAND phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71 www.fif.com.pl; e-mail: biuro@fif.com.pl

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals