V-TAC VT-118S-1 PIR Sensor Floodlight Instruction Manual

June 12, 2024
V TAC

V-TAC-logo-latest

V-TAC VT-118S-1 PIR Sensor Floodlight

Product Information

  • Product Name: PIR Sensor Floodlight
  • Model: VT-118S-1, VT-128S-1, VT-138S-1, VT-158S-1
  • SKU: 20292, 20293, 20294, 20280, 20281, 20282, 20295, 20296, 20297, 20283, 20284, 20285, 20298, 20299, 20300, 20286, 20287, 20288, 20291, 20301, 20302, 20303, 20289, 20290
  • Lumens: VT-128S-1 – 1510 LM, VT-138S-1 – 2340 LM, VT-158S-1 – 4000 LM
  • Watts: VT-118S-1 – 20w, VT-128S-1 – 30w
  • Beam Angle: >80
  • CRI: >0.9
  • Dimension: VT-118S-1 – 113x133x60mm, VT-128S-1 – 128x157x60mm, VT-138S-1 – 143x177x60mm
  • Input Power: AC: 220-240V, 50/60 Hz
  • Life Span: 25,000 Hours
  • Installation Height: 1.8m~2.5m
  • Time Delay: Not specified
  • Body Type: Not specified
  • Detection Range: Not specified
  • Efficiency: Not specified
  • Detection Distance: Not specified

Product Usage Instructions

  1. Switch off the power.
  2. Confirm the installation position.
  3. Punch holes in the building surface with an impact drill.
  4. Insert expansion bolts into the holes.
  5. Fix the bracket onto the expansion bolts.
  6. Connect the input line with the L live wire (brown), N zero wire (blue), and yellow-green ground wire. Use insulation tape and waterproof tape for proper insulation and waterproof treatment. It is recommended to use a professional waterproof junction box.
  7. Switch on the power and test the light.

Note: When switching between different modes, there should be a gap of at least 2 seconds. If the gap exceeds 3 seconds, the mode will not switch. If you have any queries or issues with the product, please contact us at support@v-tac.eu. For more product range and inquiries, please reach out to our distributor or nearest dealers located at V-TAC Europe Ltd., Bulgaria, Plovdiv 4000, Bul.L. Karavelow 9B.

Please refer to the QR code provided to access the user manual in multiple languages.
This marking indicates that this product should not be disposed of with other household wastes. Caution, risk of electric shock.

TECHNICAL DATA

MODEL VT-118S-1 VT-128S-1 VT-138S-1 VT-158S-1
SKU 20292,20293

20294,20280

20281,20282

| 20295,20296

20297,20283

20284,20285

| 20298,20299

20300,20286

20287,20288

| 20291,20301

20302,20303

20289,20290

LUMENS| 735 LM| 1510 LM| 2340 LM| 4000 LM
WATTS| 10w| 20w| 30w| 50w
BEAM ANGLE| 100°| 100°| 100°| 100°
CRI| >80| >80| >80| >80
DF| >0.9| >0.9| >0.9| >0.9
DIMENSION| 113x133x60mm| 128x157x60mm| 143x177x60mm| 178x195x60mm
INPUT POWER| AC: 220-240V, 50/60 Hz
LIFE SPAN| 25,000 Hours
INSTALLATION HEIGHT| 1.8m~2.5m
TIME DELAY| Min: 10sec±3sec; Max: 7min±2min
BODY TYPE| Aluminums
DETECTION RANGE| 140°±20°
EFFICIENCY| 85+ Lm/w
DETECTION DISTANCE| 3-10m(Radius)

INTRODUCTION & WARRANTY
Thank you for selecting and buying V-TAC product. V-TAC will serve you the best. Please read these instructions carefully before starting the installation and keep this manual handy for future reference. If you have any another query, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at the best. The warranty is valid for 5 years from the date of purchase. The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no warranty against damage to any surface due to incorrect removal and installation of the product. The products are suitable for 10-12 Hours Daily operation. Usage of product for 24 Hours a day would void the warranty. This product is warranted for manufacturing defects only.

V-TAC-VT-118S-1-PIR-Sensor-Floodlight Instruction-Fig-
\(2\)

WARNING

  • Please make sure to turn off the power before starting the installation.
  • Installation must be performed by a qualified electrician.
  • The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire should be replaced.
  • If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
  • Proper grounding should be ensured throughout the installation.
  • Replace any cracked protective shield.
  • Minimum distance from lighted objects 1m.
  • Waterproof terminal block is not included
  • To reduce the risk of strangulation the flexible wiring connected to this luminaire shall be effectively fixed to the wall if the wiring is within arm’s reach.

This marking indicates that this product should not be disposed of with other household wastes.
Caution, risk of electric shock.

MULTI-LANGUAGE MANUAL QR CODE
Please scan the QR code to access the manual in multiple languages.

INSTALLATION DIAGRAM

V-TAC-VT-118S-1-PIR-Sensor-Floodlight Instruction-Fig-
\(6\)

INSTALLATION INSTRUCTION

  1. Switch off the power.
  2. Confirm the installation position.
  3. Punch holes in building surface with impact drill.
  4. Insert expansion bolt.
  5. Fixed bracket.
  6. The input line is connected with “L” live wire in brown, “N” zero wire in blue, and yellow-green ground wire. Insulation tape and waterproof tape are needed after connecting the wires. Make insulation and waterproof treatment. It is recommended to use professional waterproof junction box.
  7. Switch on the power and test the light.

FUNCTION

  • LUX Setting: Can identify day and night. The consumer can adjust the work ambient light. It can work during the daytime and at night when adjusted to the “sun” position (max). It can work in the ambient light less than 10LUX when it is adjusted on the “moon” position (min). As for the adjustment pattern, please refer to the testing pattern.
  • SENS adjustable: For low sensitivity with 3m for detection distance set the SENS knob to (-); for High sensitivity with 10m set the knob to (+).
  • Time-Delay is added continually: When it receives the second induction signals after the first induction, it will compute time once more on the basis of the first time-delay rest.
  • Time–Delay is adjustable. It can be set according to the consumer’s desire. The minimum time is 10s. The maximum is 7 min.

MANUAL OVERRIDE FUNCTION

  • The floodlight comes with a special feature where it can be switched between sensor mode and constant lighting mode.
  • To activate constant lighting mode, switch off the power and then switch it on within 2 seconds.
  • The light shall flash for a while confirming that it has been switched to constant lighting mode.
  • To activate sensor mode, switch off the power and then switch it on after 2 seconds.
  • The light shall flash for a while confirming that it has been switched to sensor mode.

NOTE: Kindly keep a gap of 2 seconds when switching between the two modes. If it exceeds 3 seconds,it will not switched.

TEST

  • Turn the SENS knob clockwise on the maximum (+). Turn the TIME knob anti-clockwise on the minimum(-). Turn the LUX knob clockwise on the maximum(sun).
  • When you switch on the power, the light will be on at once, and 5-30 seconds later will be off automatically. Then if the light receives induction signal, it can work normally
  • After 10sec of the first detection, the light could work again. If there is no induction signal, the load will stopped working within
  • Turn the LUX knob anti-clockwise to minimum. If it is adjusted to 10LUX the load and the sensor should not work when testing in daylight. If you cover the detection window with opaque object such as towel etc, the load will work. Under no induction signal the load will stop working within 10 seconds.

Note: When testing in daylight, please turn the LUX knob to (SUN) position, otherwise the sensor lamp will not work.

  • In front of the detection window please ensure there is no hinder or unrest objects effecting the detection.
  • The working temperature will affect the detection distance. The working temperature is -20°C ~+ 24°C

TROUBLESHOOTING

Why does the sensor not switch OFF the light automatically?

  • Please check if there is a continuous signal in the detection field.
  • Please check if the time delay has been set to maximum.
  • Please check if the power corresponds to the instructions.
  • Please check if the temperature near the sensor changes such as air condition or central heating.

Why is the sensitivity of the sensor poor?

  • Please check if there is any hinder in front of the detection window.
  • Please check if the ambient temperature is too high.
  • Please check if the induction signal source is in the detection field.
  • Please check if the installation height corresponds as per the installation height mentioned on the instructions.