Perlick CR-ACC-D1 Column Dual Installation Kit Handle To Handle with Heater Instructions

June 12, 2024
Perlick

Perlick CR-ACC-D1 Column Dual Installation Kit Handle To Handle with Heater Instructions
Handle To Handle with Heater

Instruction

STEP #1: OPEN THE DOORS TO THE CABINETS. GRAB BOTH SIDES OF THE FRONT GRILL PLATE AND PULL STRAIGHT OUT IN ORDER TO POP THE CLIPS OUT OF THE LATCHS. DO THIS TO BOTH CABINETS.
Installation Instruction

STEP #2: DETERMINING WHICH CABINET WILL BE ON THE LEFT SIDE. ATTACH THE “SIDE BY SIDE HEATER ASSEMBLY” (1010469) TO THE RIGHT SIDE OF THE LEFT CABINET WITH (3) M50050-466.

STEP #3: ONCE THE HEATER ASSEMBLY IS ATTACHED, SNAP (1) 1-1/4″ BUSHING INTO THE SIDE OF THE CABINET.
Installation Instruction

STEP#4: RUN THE WIRES FROM THE HEATING ASSEMBLY THROUGH THE 1- 1/4″ BUSHING AND SNAP THE END CONNECTOR INTO THE CUT OUT OF BRACKET 1009975-1

STEP #5: ATTACH BRACKET 1009975-1 WITH (2) M50095-122. CAUTION: DO NOT PINCH WIRES FROM HEATING ASSEMBLY.

ITEM NO. PART NUMBER DESCRIPTION Default/QTY.
1 1008781 SCREW, M6 X 12MM, THRD 8
2 1009975-1 BRACKET, MOUNTING, MACHINE COMP. WIRE HARNESS, COLUMN 1
3 1010469 SIDE BY SIDE HEATER ASSEMBLY, COLUMN 1
4 1010546 M5x10 MACH SCR, LOW HEAD, NBK PART NO: SSH-M5-10 6
5 1010667 BUSHING, SPLIT, 1-1/4″ HOLE, BLACK, HEYCO 2881 1
6 1012862 POWER CORD KIT 1
7 1013719-1 BRACKET, ATTACHING, COLUMN, FOR SIDE BY SIDE INSTALLS 4
8 1015035-1 CENTER TRIM, SIDE BY SIDE INSTALL, COLUMN 1
11 M50050-466 #10 X 1/2″ PH Truss Head SMS #410 S.S., Type “AB”, 11
12 M50095-122 Screw, Sheet Metal, #10-16 x 1/2″ Thin-Lock TM, PH
Undercut Pan 2
D 47.75″ WAS 49″ 2/05/2019
--- --- ---
C UPDATE

INSTRUCTION
LAYOUT| 5/30/2018

STEP #6: SELECT THE CABINET THAT WILL BE PLACED ON THE RIGHT SIDE. SECURE (1) 1013719-1TO THE FRONT BASE WITH (2) 1008781 SCREWS
Installation Instruction

STEP #7: REMOVE ALL PROTECTIVE FILM FROM THE CENTER TRIM (1015035-1).

STEP #8: ATTACH THE CENTER TRIM TO LEFT SIDE OF THE CABINET THAT WILL BE ON THE RIGHT, WITH (6) 1010546. BEFORE FULLY TIGHTENING SCREWS, MAKE SURE THE CENTER TRIM SITS FLUSH WITH THE CABINET FACE.
Installation Instruction

STEP #9 : MOVE BOTH CABINETS DIRECTLY NEXT TO EACH OTHER SO THAT THE LEFT CABINET COMES IN CONTACT WITH THE CENTER TRIM.

STEP #10: SECURE BOTH CABINETS TOGETHER BY SECURING THE “ATTACHING BRACKET (1013719-

  1. ” PREVIOUSLY SECURED TO THE RIGHTCABINET, TO THE LEFT CABINET WITH (2) 1008781 SCREWS
    Installation Instruction

STEP #11: SECURE BOTH CABINETS TOGETHER AT THE TOP WITH (2) 1013719-1 AND (8) M50050-466
Installation Instruction

STEP #12: SECURE BOTH CABINETS TOGETHER AT THE BACK WITH (1) 1013719-1 AND (4) 1008781

STEP #13: ONCE ALL BRACKETS HAVE BEEN SECURED IN PLACE, ATTACH THE FRONT GRILLS BACK ONTO THE UNT.

STEP #14: PLUG POWER CORD (1012862) INTO HEATING ASSEMBLY CONNECTOR NOTE: HEATING ASSEMBLY CAN UTILIZE SAME ELECTRICAL CIRCUIT AS THE CABINET

PERLICK CORPORATION
MILWAUKEE, WI 53223
PROPERTY OF THE PERLICK CORP.
NOT TO BE COPIED OR USED DETRIMENTAL TO OUR INTERESTS

D:\Perlick\Engineering\Projects\Refrigeration\1601802\CAD Files\1014974.slddrw