Perlick FR Series FR36RT-3-SS 36-Inch Stainless Steel Glass Froster and Plate Chiller User Manual
- June 4, 2024
- Perlick
Table of Contents
- Perlick FR Series FR36RT-3-SS 36-Inch Stainless Steel Glass Froster and
- Glass Frosters Installation & Operation Manual
- GENERAL INFORMATION
- Introduction
- Warranty
- SAFETY
- IMPORTANT!
- PREPARING THE CABINET – GLASS FROSTERS
- Refrigerant
- Plumbing
- Electrical
- **** Adjustable Partitions & Shelving
- Installing Casters or Legs (optional)
- Placing the Cabinet
- HOW TO OPERATE – GLASS FROSTERS
- Temperature Control
- Digital Temperature Control
- Defrosting The System
- The Six Hour Manual Defrost
- The Four Hour Defrost Timer
- HOW TO OPERATE – GLASS FROSTERS
- Cleaning the Condenser
- Cleaning the Cabinets
- Avoiding Stainless Steel Corrosion
- WIRING DIAGRAM – GLASS FROSTERS
- REPLACEMENT PARTS – GLASS FROSTERS
- REPLACEMENT PARTS – GLASS FROSTERS
- SPEC DRAWINGS – GLASS FROSTERS
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Perlick FR Series FR36RT-3-SS 36-Inch Stainless Steel Glass Froster and
Plate Chiller User Manual
Glass Frosters Installation & Operation Manual
JOB|
---|---
AREA|
ITEM NO.|
MODEL NO.|
FR24 SERIES
FR36 SERIES
FR48 SERIES
FR60 SERIES
MODEL NUMBERS | FR24 | FR36 | FR48 | FR60 |
---|
EXTERIOR CABINET DIMENSIONS
| Length – in. (mm)| 24 (610)| 36 (914)| 48 (1219)| 60 (1524)
Depth – in. (mm)| 24 (610)| 24 (610)| 24 (610)| 24 (610)
Height – in. (mm)| 34-1/8 (866)| 34-1/8 (866)| 34-1/8 (866)| 34-1/8 (866)
INERNAL NET VOLUME – cubic ft. (liters)| 4.2 (118)| 8.6 (242)| 12.5
(353)| 16.3 (462)
PLATE CAPACITY | 135 Plates| 215 Plates| 300 Plates| 400 Plates
GLASS CAPACITY | 90 Glasses| 142 Glasses| 214 Glasses| 286 Glasses
W/ OPTIONAL THIRD SHELF| N/A| 172 Glasses| 273 Glasses| 363 Glasses
SHIPPING WEIGHT LBS. (KG.)| 190 (86)| 245 (111)| 300 (136)| 353 (160)
CABINET CONSTRUCTION (INTERIOR)| All models have stainless steel
walls and floor.
CABINET CONSTRUCTION (EXTERIOR)
| Choice of black, stainless steel and all stainless.
Black Option: Front and ends are black vinyl coated steel, back and bottom are galvanized. Stainless Steel Option: Front and ends are stainless steel, back and bottom are galvanized. All Stainless Option: Front, ends, back and bottom are all stainless steel.
DOORS AND HARDWARE| Sliding style open. Stainless steel top and bottom
panss. Die cast handle
PLUMBING| No drain required. Condensate evaporates automatically.
INSULATION| 2 inch foamed-in-place, environmentally friendly Ecomate®
polyurethane insulation.
VENTILATION| 2’ model is front vented, all other models require 2”
clearance from wall on either left end or back of cabinet for proper air flow.
TEMPERATURE SPECIFICATIONS
| Default Temperature Setpoint: Standard Temp (RT) Models – °F [°C]| 0
[-17.75]
Adjustable Setpoint Range: Standard Temp (RT) Models – °F [°C]| (-) 10 to
(+)10 [-23.3 to -12.2]
ELECTRICAL SPECIFICATIONS
| Supply| 120 VAC/60 Hz/1 Ph
Running Load Amps| 3.8| 3.8| 3.8| 3.8
Power Cord| 6-foot length with NEMA 5-15 plug.
Thermostat| NSF Listed electronic control.
Defrost Type| Automatically defrosts electrically every 4 hrs for approximatly
20 minutes
Manual Defrost| Push button defrost system, manually initiated at the end of
each day, Automatically terminates after six hours.
REFRIGERATION SPECIFICATIONS
| Condensing Unit| Hermetic condensing unit pulls out for service and
cleaning.
Expansion Device| Capillary Tube
Refrigerant| R290
Refrigerant Charge (g)| 80| 100| 100| 115
Compressor H.P.| 1/4| 1/4| 1/4| 1/4
Total Heat of Rejection At 75°F ambient (BTU/h)| 2980| 2980| 2980| 2980
OPTIONAL ACCESSORIES
| Flat shelving • Divider shelving • Roller basket shelving Set of 4 Adjustable legs (Multiple sizes available)
Set of 4 Casters w/ brakes (Multiple sizes available) • 2’, 3’, 4’,and 5’ Bottle Rail (field Installed)
GENERAL INFORMATION
Introduction
This manual has been prepared to assist you in the installation of your Glass
Froster and to acquaint you with its operation and maintenance.
We dedicate considerable time to ensure that our products provide the highest
level of customer satisfaction. If service is required, call Perlick at
1-800-777-7267 or your dealer who can
provide you with a list of qualified service agents. For your own protection,
never return merchandise for credit without our approval.
We thank you for selecting a Perlick product and assure you of our continuing
interest in your
Warranty
To register your product, visit our web site at
www.perlick.com. Click on “Commercial”, then
“Service”. Click on the link “Warranty Registration Form”. You must complete
and submit this form or the installation date will revert back to the ship
date.
Please record the purchase date and the dealer’s name, address and telephone
number below.
Model Number: _
Serial Number: _
Purchase Date:
Dealer Name & Address _
satisfaction.
_Phone Number __
SAFETY
PLEASE READ all instructions completely before attempting to install or
operate the unit.
Take particular note of the DANGER, WARNING an CAUTION information in the
manual.
The information is important for the safe and efficient installation,
operation and care of your Perlick unit.
DANGER Indicates a hazard that WILL result in serious injury or death if
precautions are not followed.
WARNING Indicates a hazard MAY cause serious injury or death if precautions
are not followed.
CAUTION Indicates a hazard where minor injury or product damage may occur if
precautions are not followed.
NOTICE Indicates that property damage may occur if warnings or instructions
are not followed.
IMPORTANT!
Read and understand all information in this manual before attempting the
installation.
All plumbing and electrical work must be performed by a qualified technician
and conform to all applicable state and local codes.
PREPARING THE CABINET – GLASS FROSTERS
Refrigerant
All models covered in this user manual are manufactured using refrigerant R290 (Propane). R290 is a hydrocarbon. This refrigerant is flammable and is only allowed for use in appliances which fulfill the requirements of UL 471 (To cover potential risk originated from the use of flammable refrigerants). Consequently, R290 is only allowed to be used in refrigerating appliances which are designed for this refrigerant and fulfill the above-mentioned standard.
- R290 is heavier than The concentration will always be highest at floor level.
- The explosion limits are as follows:
- Lower Limit: 7% by vol. (37 g/m3)
- Upper Limit: 5% by vol. (177 g/m3)
- Ignition Temperature: 470 °C
DANGER Take caution when handling, moving and using the product to avoid
damaging the refrigerant tubing or increasing the risk of a leak.
WARNING All service work shall be performed by factory authorized service
personnel and all component parts shall be replaced with like components to
minimize the risk of possible v CAUTION ignition due to incorrect parts or
improper service. If service is necessary, repair work must be performed by a
Perlick authorized servicer. Work done by unqualified individuals could
potentially be dangerous and will void the warranty.
NOTICE Uncrating and Inspection Remove all crating material. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transport company. Perlick is not responsible for damage in transit.
This product contains blown foam insulation using blowing agent R-611 (Methyl Formate). The foam in this product does not contain HFC’s, CFC’s, or HCFC’s.
Plumbing
No plumbing connections are required. Condensate from the cooling coil automatically evaporated through a condensate pan located in the condensing unit section.
Electrical
CAUTION The cabinet must be connected to a separately fused power source
(see Electrical Specification Plate affixed to unit) in accordance with
National and Local electrical codes.
Do not attempt to operate the equipment on any other power source than
that listed on the
Electrical Specification Plate.
**** Adjustable Partitions & Shelving
Perlick Glass Frosters may be provided with adjustable partitions and shelving which will accommodate various bottle sizes.
- W h e n p l a c i n g g l a s s e s i n chiller make sure to ensure proper air flow between
- When loading product into cabinet, care must be taken to avoid blocking airflow into and out of the Maintain at least 2” of clearance on evaporator air intake and exhaust for proper operation.
Installing Casters or Legs (optional)
Attach casters or legs to the cabinet bottom in holes provided. Use the supplied 1/4” – 20 hex head self-tapping machine screws. If unit is tipped on its back for an extended period of time, wait 24 hours after unit is uprighted to plug the unit in.
Placing the Cabinet
To assure maximum performance, fresh air must be allowed to circulate through
the machinery compartment. It is important to allow at least two inched of
clearance at the back or left end of the cabinet. Do not place anything in
front of the cabinet that would obstruct air flow at these grilles. Do not
place the unit in an unventilated small room.
CAUTION Removing the factory installed back clearance
spacers without providing proper left side grill
clearance for compressor air flow will void
the warranty.
HOW TO OPERATE – GLASS FROSTERS
Cabinet should be leveled. For sanitation purposes, it may be necessary to seal the base of the cabinet to the floor. This can be accomplished by laying a bead of silicone sealant along the base of the cabinet as shown by the figure below (figure 1).
Temperature Control
A digital temperature control is located on the front face of the Glass Froster, above the condensing unit housing. It is factory set at approximately 0°F for standard refrigeration.
Digital Temperature Control
To display the Set point values press the key when the ‘SET’ label is
displayed. The Set point value appears on the display. To change the Set point
value, press the and keys within 15 seconds. Press to confirm the
modification.
The condenser fan motor turns off and on with compressor. The evaporator fan
motor runs continuously.
Figure 2: Digital Temperature Controller
Defrosting The System
This system consists of a six-hour, as well as a four hour defrost cycle. The six hour defrost cycle is manually activated and automatically terminated, while the four hour cycle is completely automatic.
The Six Hour Manual Defrost
The six hour manual defrost shuts off the power to the condensing unit, door frame heater, evaporator heater, and the automatic four hour defrost timer, while it supplies power to the evaporator fan. To activate the six hour defrost system, depress (and hold for 3 seconds) the defrost switch located next to the controller above the front grill of the cabinet. When the manual defrost cycle initiates a fan icon will appear on the controller display as well as “def” (figure 3a). When the defrost cycle ends, the cabinet resumes normal operation. To cancel a manual defrost cycle, momentarily turn off the electricity to the machine (unplug unit).
Figure 3a
The Four Hour Defrost Timer
This automatic defrost ensures that frost will not buildup on the evaporator coil. Every four hours it shuts down the condensing unit, box frame heater, evaporator fan and supplies power to the defrost element clamped to the bottom of the evaporator. When automatic defrost is initiated the controller will display a melting snowflake as well as “def” for the duration of the defrost (figure 3b).
Figure 3b
HOW TO OPERATE – GLASS FROSTERS
To manually initiate the automatic defrost cycle press and hold either the up or down arrows. The defrost cycle lasts for approximately 20 minutes followed by 2 minutes of drip time (where the evaporator fan shuts off to allow water to drip off the coil and drain before it can refreeze). (figure 3c).
Figure 3c
When the cycle is complete the unit will resume cooling operation shown on the controller with a snowflake and fan icon, however “def” will remain on the display screen until the next time the set point value is reached (figure 3d). During normal operation it is recommended that the doors are not left open to prevent excessive frost buildup on the coil.
Figure 3d
Cleaning the Condenser
DANGER Flammable Refrigerant. Risk of fire or explosion. Do not damage
refrigeration tubes.
The condenser (located behind the front grille) should be inspected every
30 days, and cleaned, if Failure to keep the condenser clean will cause a loss
in condensing unit efficiency, or compressor failure.
Cleaning the Doors
- Doors should be periodically removed from the cabinet and inspected for a buildup of foreign materials, such as syrups, beer, Buildups on the underside of the doors, along with the cabinet breaker strips on which they ride, will cause them to bind, and therefore, not function as designed. If dirty, these surfaces should be cleaned with a mild detergent and water and then coated with an NSF certified silicone lubricating material.
To remove doors:
- With door closed, lift it upward by its handle and slide forward until doors clears the cabinet top. Use the reverse procedure to reinstall the doors.
Cleaning the Cabinets
- Use a damp cloth with a mild detergent and water to clean the inside and outside of the Dry thoroughly. Do not allow cleaning agents or large amounts of water to go down the drain. Use an acceptable stainless steel polish to clean all stainless steel surfaces. Never use steel wool or scouring pads to clean stainless steel.
Avoiding Stainless Steel Corrosion
Corrosion can be prevented by following product cautions, cleaning instructions and avoiding use of certain chemicals or objects which will cause stainless steel corrosion.
STAINLESS STEEL ENEMY
- Steel wool or steel scouring pads
- Cherry/Orange/Olive juice
- Chlorine Bleach
- Sharp Objects
WIRING DIAGRAM – GLASS FROSTERS
REPLACEMENT PARTS – GLASS FROSTERS
REPLACEMENT PARTS – GLASS FROSTERS
MODEL NOS.| | FR24 RT – 3| FR36 RT – 3| FR48 RT – 3|
FR60 RT – 3
---|---|---|---|---|---
Item| Description| Part Numbers
1
| Complete condensing unit| 1018400| 1018400| 1018400| 1018400
Replacement compressor, R290| C22999CMP11| C22999CMP11| C22999CMP11|
C22999CMP11
Condensing unit fan motor assy.| 1013047| 1013047| 1013047| 1013047
Condensing unit filter drier| C22999DAH01| C22999DAH01| C22999DAH01|
C22999DAH01
Condensing units start components| C22999STCP10| C22999STCP10| C22999STCP10|
C22999STCP10
3| Evaporator fan| 71386| 71386| 71386| 71386
4| Evaporator coil| 64785-1EP| C17511-1EP| C17511-1EP| C17511-2EP
5| Defrost heater| C25655-1| 65045-1| 65045-1| 61900
6| Temperature sensor| 1005668| 1005668| 1006584| 1006584
7| Controller Bracket| 1024461-1| 1024228-2| 1024428-2| 1024228-2
8| Manual Defrost Switch| 1026317| 1026317| 1026317| 1026317
9| Front grille| 1024465-1| 1024230-1| 1024230-1| 1024230-1
10| Rear grille/panel| 66498-1| 65662-3| 65662-3| 65662-3
11| Top assembly| RT-SL2| RT-SL2| RT-SL2| RT-SL2
12| Top wiper gasket| 63671-24| 63671-36| 63671-48| 63671-60
13| Door assembly| RD-SL2| RD-SL2| RD-SL2| RD-SL2
14| Vertical partition| 65503| 66441| 66441| 66441
15| Roller basket| N/A| 66442-1| 66442-1| 66442-1
16| Wide shelf| N/A| 64811-1| 64811-1| 64811-1
17
| Narrow shelf| 64809-1| 64809-1| 64809-1| 64809-1
Bottom floor rack (wide)| 64814-1| 64814-1| 64814-1| 64814-1
18
| Bottom floor rack (narrow)| N/A| N/A| 64815-1| 64815-1
Shelf with side rail| N/A| 64810-1| 64810-1| 64810-1
19| Shelf bracket| 65653-24| 65653-36| 65653-48| 65653-60
20| Door handle| 63931| 63931| 63931| 63931
21| Evaporator drain pan| 1025311-1| 1025311-2| 1025583-1| 1025583-2
ITEMS NOT SHOWN
| Wire harness, main| 1026161| 1026161| 1026161| 1026161
Suction line and capillary tube assembly| 1026509| 1026509| 1026526| 1026528
Mullion assembly| N/A| N/A| 66551| 66551
Refrigerant charge (grams R290)| 80| 100| 100| 115
Defrost temp. limit switch| 57676| 57676| 57676| 57676
Evaporator fan DC driver| 68758| 68758| 68758| 68758
Digital temperature controller| 1026455| 1026455| 1026455| 1026455
SPEC DRAWINGS – GLASS FROSTERS
24″ CABINET
36″, 48″, 60″ CABINET
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>