Perlick FR Series FR24RT-3-BL Glass Froster User Manual
- June 4, 2024
- Perlick
Table of Contents
Installation & Operation Manual
Glass/Mug Foresters
FR Series
FR Series FR24RT-3-BL Glass Froster
JOB|
---|---
AREA|
ITEM NO.|
MODEL NO.|
FR24 SERIES
FR36 SERIES
FR48 SERIES
FR60 SERIES
MODEL NUMBERS | FR24 | FR36 | FR48 | FR60 |
---|---|---|---|---|
EXTERIOR CABINET DIMENSIONS | Length – in. (mm) | 24 (610) | 36 (914) | |
48 (1219) | 60 (1524) | |||
Depth – in. (mm) | 24 (610) | 24 (610) | 24 (610) | 24 (610) |
Height – in. (mm) | 34-1/8 (866) | 34-1/8 (866) | 34-1/8 (866) | 34-1/8 (866) |
INTERNAL NET VOLUME – cubic ft. (liters) | 4.2 (118) | 8.6 (242) | 12.5 | |
(353) | 16.3 (462) | |||
**PLATE CAPACITY *** | 135 Plates | 215 Plates | 300 Plates | 400 Plates |
**GLASS CAPACITY *** | 90 Glasses | 142 Glasses | 214 Glasses | 286 Glasses |
W/ OPTIONAL THIRD SHELF | N/A | 172 Glasses | 273 Glasses | 363 Glasses |
SHIPPING WEIGHT LBS. (KG.) | 190 (86) | 245 (111) | 300 (136) | 353 (160) |
CABINET CONSTRUCTION (INTERIOR) | All models have stainless steel |
walls and floor.
CABINET CONSTRUCTION (EXTERIOR)| Choice of black, stainless steel, and
all stainless.
Black Option: Front and ends are black vinyl coated steel, back and
bottom are galvanized. Stainless Steel Option: Front and ends are
stainless steel, and the back and bottom are galvanized. All Stainless
Option: Front, ends, back and bottom are all stainless steel.
DOORS AND HARDWARE| Sliding style open. Stainless steel top and bottom
pans. Die-cast handle
PLUMBING| No drain is required. Condensate evaporates automatically.
INSULATION| 2-inch foamed-in-place, environmentally friendly Ecomate®
polyurethane insulation.
VENTILATION| The 2’ model is front vented, all other models require 2”
clearance from the wall on either the left end or back of the cabinet for
proper airflow.
TEMPERATURE SPECIFICATIONS| Default Temperature Setpoint: Standard
Temp (RT) Models – °F [°C]| 0 [-17.75]
Adjustable Setpoint Range: Standard Temp (RT) Models – °F [°C]| (-) 10 to
(+)10 [-23.3 to -12.2]
ELECTRICAL SPECIFICATIONS| Supply| 120 VAC/60 Hz/1 Ph
Running Load Amps| 3.8| 3.8| 3.8| 3.8
Power Cord| 6-foot length with NEMA 5-15 plug.
Thermostat| NSF Listed electronic control.
Defrost Type| Automatically defrosts electrically every 4 hrs for
approximately 20 minutes
Manual Defrost| The push button defrosts system, manually initiated at the end
of each day, Automatically terminates after six hours.
REFRIGERATION SPECIFICATIONS| Condensing Unit| The hermetic condensing
unit pulls out for service and cleaning.
Expansion Device| Capillary Tube
Refrigerant| R290
Refrigerant Charge (g)| 80| 100| 100| 115
Compressor H.P.| 1/4| 1/4| 1/4| 1/4
Total Heat of Rejection At 75°F ambient (BTU/h)| 2980| 2980| 2980| 2980
OPTIONAL ACCESSORIES| Flat shelving • Divider shelving • Roller basket
shelving
Set of 4 Adjustable legs (Multiple sizes available)
Set of 4 Casters w/ brakes (Multiple sizes available) • 2’, 3’, 4’, and 5’
Bottle Rail (field Installed)
- Capacity based on the use of 3″ diameter glass and 9-1/2″ diameter X 1/2″ thick plate.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
**GENERAL INFORMATION
**
Introduction
This manual has been prepared to assist you in the installation of your Glass
Froster and to acquaint you with its operation and maintenance.
We dedicate considerable time to ensuring that our products provide the
highest level of customer satisfaction. If service is required, call Perlick
at 1-800-777-7267 or your dealer who
can provide you with a list of qualified service agents. For your own
protection, never return merchandise for credit without our approval.
We thank you for selecting a Perlick product and assure you of our continuing
interest in your satisfaction.
Warranty
To register your product, visit our website at
www.perlick.com. Click on “Commercial”, then
“Service”. Click on the link “Warranty Registration Form”. You must complete
and submit this form or the installation date will revert back to the ship
date.
Please record the purchase date and the dealer’s name, address, and telephone
number below.
Model Number: ____
Serial Number: __
Purchase Date:
Dealer Name & Address __
Phone Number__
SAFETY
PLEASE READ all instructions completely before attempting to install or
operate the unit.
Take particular note of the DANGER, WARNING, and CAUTION information in the
manual. The information is important for the safe and efficient installation,
operation, and care of your Perlick unit.
DANGER Indicates a hazard that WILL result in serious injury or death if
precautions are not followed.
WARNING
Indicates a hazard MAY cause serious injury or death if precautions are not
followed.
CAUTION
Indicates a hazard where minor injury or product damage may occur if
precautions are not followed.
NOTICE
Indicates that property damage may occur if warnings or instructions are not
followed.
IMPORTANT!
Read and understand all information in this manual before attempting the
installation.
All plumbing and electrical work must be performed by a qualified technician
and conform to all applicable state and local codes.
PREPARING THE CABINET – GLASS FORESTERS
Refrigerant
All models covered in this user manual are manufactured using refrigerant R290
(Propane). R290 is a hydrocarbon. This refrigerant is flammable and is only
allowed for use in appliances that fulfill the requirements of UL 471 (To
cover potential risk originating from the use of flammable refrigerants).
Consequently, R290 is only allowed to be used in refrigerating appliances that
are designed for this refrigerant and fulfill the above-mentioned standard.
- R290 is heavier than air. The concentration will always be highest at floor level.
- The explosion limits are as follows:
– Lower Limit: 1.7% by vol. (37 g/m3)
– Upper Limit: 9.5% by vol. (177 g/m3)
– Ignition Temperature: 470 °C
DANGER
Take caution when handling, moving, and using the product to avoid damaging
the refrigerant tubing or increasing the risk of a leak.
WARNING
All service work shall be performed by factory-authorized service personnel
and all component parts shall be replaced with like components to minimize the
risk of possible ignition due to incorrect parts or improper service.
CAUTION
If service is necessary, repair work must be performed by a Perlick authorized
servicer. Work done by unqualified individuals could potentially be dangerous
and will void the warranty.
Uncrating and Inspection
Remove all crating material. Carefully inspect the cabinet for hidden damage.
If damage is discovered, file your claim immediately with the transport
company. Perlick is not responsible for damage in transit. This product
contains
NOTICE
This product contains blown foam insulation using blowing agent R-611 (Methyl
Formate).
The foam in this product does not contain HFCs, CFCs, or HCFCs.
Plumbing
No plumbing connections are required.
Condensate from the cooling coil automatically evaporated through a condensate
pan located in the condensing unit section.
Electrical
The cabinet must be connected to a separately fused power source (see
Electrical Specification Plate affixed to unit) in accordance with National
and Local electrical codes.
CAUTION
Do not attempt to operate the equipment on any other power source than that
listed on the Electrical Specification Plate.
Adjustable Partitions & Shelving
Perlick Glass Frosters may be provided with adjustable partitions and shelving
which will accommodate various bottle sizes.
- When placing glasses in the chiller make sure to ensure proper airflow between glasses.
- When loading product into the cabinet, care must be taken to avoid blocking airflow into and out of the evaporator. Maintain at least 2” of clearance on the evaporator air intake and exhaust for proper operation.
Installing Casters or Legs (optional)
Attach casters or legs to the cabinet bottom in the holes provided. Use the
supplied 1/4” – 20 hex head self-tapping machine screws. If the unit is tipped
on its back for an extended period of time, wait 24 hours after the unit is
uprighted to plug the unit in.
Placing the Cabinet
To assure maximum performance, fresh air must be allowed to circulate through
the machinery compartment. It is important to allow at least two inches of
clearance at the back or left end of the cabinet. Do not place anything in
front of the cabinet that would obstruct airflow at these grilles. Do not
place the unit in an unventilated small room.
CAUTION
Removing the factory-installed back clearance spacers without providing proper
left-side grill clearance for compressor airflow will void the warranty.
The cabinet should be leveled.
For sanitation purposes, it may be necessary to seal the base of the cabinet
to the floor. This can be accomplished by laying a bead of silicone sealant
along the base of the cabinet as shown in the figure below (figure 1).
Figure 1. Sealing Cabinet to Floor
Temperature Control
Digital temperature control is located on the front face of the Glass Froster,
above the condensing unit housing. It is factory set at approximately 0°F for
standard refrigeration.
Digital Temperature Control
To display the Setpoint values press the key when the ‘SET’ label is
displayed. The Setpoint value appears on the display. To change the Setpoint
value, press the and keys within 15 seconds. Press to confirm the
modification.
The condenser fan motor turns off and on with the compressor. The evaporator
fan motor runs continuously.
Figure 2: Digital Temperature Controller
Defrosting The System
This system consists of a six-hour, as well as a four-hour defrost cycle. The
six-hour defrost cycle is manually activated and automatically terminated,
while the four-hour cycle is
completely automatic.
The Six-Hour Manual Defrost
The six-hour manual defrost shuts off the power to the condensing unit, door
frame heater, evaporator heater, and automatic four-hour defrost timer, while
it supplies power to the evaporator fan. To activate the six-hour defrost
system, depress (and hold for 3 seconds) the defrost switch located next to
the controller above the front grill of the cabinet. When the manual defrost
cycle initiates a fan icon will appear on the controller display as well as
“def” (figure 3a). When the defrost cycle ends, the cabinet resumes normal
operation. To cancel a manual defrost cycle, momentarily turn off the
electricity to the machine (unplug the unit).
The Four-Hour Defrost Timer
This automatic defrost ensures that frost will not build up on the evaporator
coil. Every four hours it shuts down the condensing unit, box frame heater,
and evaporator fan and supplies power to the defrost element clamped to the
bottom of the evaporator. When automatic defrost is initiated the controller
will display a melting snowflake as well as “def” for the duration of the
defrost (figure 3b).
To manually initiate the automatic defrost cycle press and hold either the up or down arrows. The defrost cycle lasts for approximately 20 minutes followed by 2 minutes of drip time (where the evaporator fan shuts off to allow water to drip off the coil and drain before it can refreeze). (figure 3c).
When the cycle is complete the unit will resume cooling operation shown on the controller with a snowflake and fan icon, however “def” will remain on the display screen until the next time the set point value is reached (figure 3d). During normal operation, it is recommended that the doors are not left open to prevent excessive frost buildup on the coil.
Cleaning the Condenser
DANGER
Flammable Refrigerant.
Risk of fire or explosion. Do not damage refrigeration tubes.
- The condenser (located behind the front grille) should be inspected every 30 days and cleaned, if necessary. Failure to keep the condenser clean will cause a loss in condensing unit efficiency or compressor failure.
Cleaning the Doors
- Doors should be periodically removed from the cabinet and inspected for a buildup of foreign materials, such as syrups, beer, etc. Buildups on the underside of the doors, along with the cabinet breaker strips on which they ride, will cause them to bind, and therefore, not function as designed. If dirty, these surfaces should be cleaned with a mild detergent and water and then coated with an NSF-certified silicone lubricating material.
- To remove doors:
- With the door closed, lift it upward by its handle and slide forward until the door clears the cabinet top. Use the reverse procedure to reinstall the doors.
- Cleaning the Cabinets
- Use a damp cloth with mild detergent and water to clean the inside and outside of the cabinet. Dry thoroughly. Do not allow cleaning agents or large amounts of water to go down the drain. Use an acceptable stainless steel polish to clean all stainless steel surfaces. Never use steel wool or scouring pads to clean stainless steel.
- Avoiding Stainless Steel Corrosion
Corrosion can be prevented by following product cautions, cleaning instructions, and avoiding the use of certain chemicals or objects which will cause stainless steel corrosion.
STAINLESS STEEL ENEMY
- Steel wool or steel scouring pads
- Cherry/Orange/Olive juice
- Chlorine Bleach
- Sharp Objects
WIRING DIAGRAM
REPLACEMENT PARTS – GLASS FORESTERS
MODEL NOS.| FR24 RT – 3| FR36 RT – 3| FR48 RT – 3| FR60
RT – 3
---|---|---|---|---
Item| Description| Part Numbers
1| Complete condensing unit| 1018400| 1018400| 1018400| 1018400
Replacement compressor, R290| C22999CMP11| C22999CMP11| C22999CMP11|
C22999CMP11
Condensing unit fan motor assy.| 1013047| 1013047| 1013047| 1013047
Condensing unit filter drier| C22999DAH01| C22999DAH01| C22999DAH01|
C22999DAH01
Condensing units start components| C22999STCP10| C22999STCP10| C22999STCP10|
C22999STCP10
3| Evaporator fan| 71386| 71386| 71386| 71386
4| Evaporator coil| 64785-1EP| C17511-1EP| C17511-1EP| C17511-2EP
5| Defrost heater| C25655-1| 65045-1| 65045-1| 61900
6| Temperature sensor| 1005668| 1005668| 1006584| 1006584
7| Controller Bracket| 1024461-1| 1024228-2| 1024428-2| 1024228-2
8| Manual Defrost Switch| 1026317| 1026317| 1026317| 1026317
9| Front grille| 1024465-1| 1024230-1| 1024230-1| 1024230-1
10| Rear grille/panel| 66498-1| 65662-3| 65662-3| 65662-3
11| Top assembly| RT-SL2| RT-SL2| RT-SL2| RT-SL2
12| Top wiper gasket| 63671-24| 63671-36| 63671-48| 63671-60
13| Door assembly| RD-SL2| RD-SL2| RD-SL2| RD-SL2
14| Vertical partition| 65503| 66441| 66441| 66441
15| Roller basket| N/A| 66442-1| 66442-1| 66442-1
16| Wide shelf| N/A| 64811-1| 64811-1| 64811-1
17| Narrow shelf| 64809-1| 64809-1| 64809-1| 64809-1
Bottom floor rack (wide)| 64814-1| 64814-1| 64814-1| 64814-1
18| Bottom floor rack (narrow)| N/A| N/A| 64815-1| 64815-1
Shelf with side rail| N/A| 64810-1| 64810-1| 64810-1
19| Shelf bracket| 65653-24| 65653-36| 65653-48| 65653-60
20| Door handle| 63931| 63931| 63931| 63931
21| Evaporator drain pan| 1025311-1| 1025311-2| 1025583-1| 1025583-2
ITEMS NOT SHOWN
Wire harness, main | 1026161 | 1026161 | 1026161 | 1026161 |
---|---|---|---|---|
Suction line and capillary tube assembly | 1026509 | 1026509 | 1026526 | 1026528 |
Mullion assembly | N/A | N/A | 66551 | 66551 |
Refrigerant charge (grams R290) | 80 | 100 | 100 | 115 |
Defrost temp. limit switch | 57676 | 57676 | 57676 | 57676 |
Evaporator fan DC driver | 68758 | 68758 | 68758 | 68758 |
Digital temperature controller | 1026455 | 1026455 | 1026455 | 1026455 |
SPEC DRAWINGS – GLASS FORESTERS
NOTES
8300 West Good Hope Road
Milwaukee, WI 53223
Toll Free 800.558.5592
Fax 414.353.7069
www.perlick.com
Form No. Z2296