Arrowhead Alarm Products PW KEYPAD-XK1 Access Systems Instruction Manual

June 10, 2024
Arrowhead Alarm Products

PW KEYPAD-XK1 Access Systems
Instruction Manual

PW KEYPAD-XK1 Access Systems

Arrowhead Alarm Products PW KEYPAD-XK1 Access Systems - fig
1

PW KEYPAD-XK1 & XK4

**SPECIFICATIONS:

**

Voltage: 12-28V AC/DC
Standby Current: 50mA
Operating Current: 120mA
Up to 999 users code & tags
IP66 Rated
Built in Prox Reader
Relay Reset time: 1-300sec. or ON/OFF (toggle) Mode  Arrowhead Alarm
Products PW KEYPAD-XK1 Access Systems - fig 2

Check www.aap.co.nz/xk1 for more information

ENTERING ADMIN MODE:
To enter programming mode press * (admin code) #. Arrowhead Alarm Products
PW KEYPAD-XK1 Access Systems - fig 3

Default admin code is: 888888.
The keypad will automatically time out after 30 seconds.
EXITING ADMIN MODE:
To Exit admin mode simply press :
ADDING USER CODES & PROX TAGS:
You can have up to 999 user codes and prox tags assigned to either Relay 1 or 2.
These are loaded at program address 11 then user slot (1 to 999)  a user slot can have a code and/or a prox tag.
First you must be in Admin Mode. Arrowhead Alarm Products PW KEYPAD-XK1
Access Systems - fig 5Note. If both 1 and 2 are pressed under Relay No. both relays 1 and 2 will operate.
Document the programmed user slots in the back of this paperwork.
DELETING USER CODES & PROX TAGS:
You can only delete a user code by knowing the user slot it is stored under.
First you must be in Admin Mode.
Arrowhead Alarm Products PW KEYPAD-XK1 Access Systems - fig
6

Prox Tags can either be deleted by slot number (same as above) or by presenting them (see below)
First you must be in Admin Mode.
Arrowhead Alarm Products PW KEYPAD-XK1 Access Systems - fig
7 Note. Multiple Prox Tags can be deleted in this was one after another.
To Delete All user slots follow the process below.
First you must be in Admin Mode.Arrowhead Alarm Products PW KEYPAD-XK1
Access Systems - fig 8 RELAY 1 RESET TIME: (default 5sec)
Relay 1 reset time can be set from 1 to 300 seconds. If 0 is selected the relay will toggle on & off.
To change reset time you must be in Admin Mode.
Arrowhead Alarm Products PW KEYPAD-XK1 Access Systems - fig
9 RELAY 2 RESET TIME: (default 5sec)
Relay 2 reset time can be set from 1 to 300 seconds. If 0 is selected the relay will toggle on & off.
To change reset time you must be in Admin Mode.
Arrowhead Alarm Products PW KEYPAD-XK1 Access Systems - fig
10 CHANGING ADMIN CODE:
To change Admin code you much be in Admin Mode first.         Arrowhead
Alarm Products PW KEYPAD-XK1 Access Systems - fig 11

Advance Programming Options

For all programming addresses below you must first be in Admin Mode.
KEYPAD BACKLIGHT: (default always On) Arrowhead Alarm Products PW KEYPAD-XK1
Access Systems - fig 13Buzzer Volume: (default level 3)
Arrowhead Alarm Products PW KEYPAD-XK1 Access Systems - fig
14DOOR BELL FEATURE: (Pressing 0 # triggers Relay 2) Note feature won’t work if users are assigned to relay 2.
Arrowhead Alarm Products PW KEYPAD-XK1 Access Systems - fig
15DOOR OPEN TOO LONG FEATURE: (requires reed switch connected between Brown & Grey wire). Arrowhead Alarm Products
PW KEYPAD-XK1 Access Systems - fig 16DOOR FORCED FEATURE: (requires reed switch connected between Brown & Grey wire).Arrowhead Alarm Products PW KEYPAD-XK1 Access Systems - fig
17

TAMPER ALARM: Arrowhead Alarm Products PW KEYPAD-XK1 Access Systems - fig
18

FACTORY RESET:
This will erase timers, options and admin code. (note the user codes and tags are kept in memory)
Power Down the keypad, press and hold then Power Up the keypad (keeping the * button pressed)
= Keypad has successfully reset

USER OPERATION:

Arrowhead Alarm Products PW KEYPAD-XK1 Access Systems - fig
20

SLOT NAME CODE Relay 1 Relay 2 TAG
001
002
003
004
005
006
007
008
009
010
011
012
013
014
015
016
017
018
019
020
021
022
023
024
025
026
027
028
029
030
031
032
033
034
035
036
037
Admin

Go to www.aap.co.nz/xk1 for more wiring diagrams and  Information. Arrowhead Alarm Products ltd.
1A Emirali Road, Silverdale 0932,
Auckland, NZ Ph. 09 414 0085
www.aap.co.nz
v1.01

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals