VICKS V912US SpeedRead Digital Thermometer Instruction Manual
- June 13, 2024
- Vicks
Table of Contents
VICKS V912US SpeedRead Digital Thermometer
Product Information
- Model: V912US, V912BBUS
- Features: Large screen display, Fever InSight feature
- Thermometer Type: Digital
- Usage: Oral, Rectal, Underarm
- Power Source: Battery (located in the battery compartment onthe back side)
READ AND SAVE THESE INSTRUCTIONS
Thank you for purchasing the Vicks SpeedRead Digital Thermometer with large
screen display and Fever InSight feature, a professionally accurate instrument
for faster and easier temperature taking. Please read these instructions
carefully to ensure accurate temperatures and safe operation. When used
properly, this high quality product will give you years of accurate,
dependable service.
IMPORTANT SAFETY INFORMATION
- High, prolonged fever requires medical attention especially for young children. Please contact your physician.
- Do not allow children to take their temperatures unattended.
- Do not allow children to walk or run during temperature taking
If you have any questions or comments about the Vicks SpeedRead Digital Thermometer, call our toll-free Consumer Relations Line: 1-800-477-0457 or e-mail consumerrelations@kaz.com.
CHANGING THE DISPLAY FROM FAHRENHEIT (F) OR CENTIGRADE (C):
With the thermometer in the OFF position, hold down the center button until
the display shows Lo. Release the button. To choose desired scale, press the
button again to move between the “F” or “C” icon shown below the Lo. Once the
“C” or “F” starts to blink, push the button again to turn off the thermometer.
You can now turn on the thermometer and the display will be in Fahrenheit (F)
or Centigrade (C) based on the scale you set in the above steps. Your
thermometer will return to Fahrenheit (F) readings when you replace your
battery. You can repeat this process to switch to Centigrade (C).
TEMPERATURE READINGS
Temperature readings vary from person to person. Although there is no one
“normal” temperature reading, a temperature, taken orally, ranging between
97°F and 100°F is considered normal. A rectal temperature is generally 1°
higher and an underarm (axillary) temperature will be 1° lower.
The best method to determine your own normal temperature is to use the
thermometer when you are feeling well. Record your reading twice a day (early
morning and late afternoon). Take the average of the two temperatures. This is
considered your normal body temperature. Any variation from it may indicate
some sort of illness and you should consult your physician.
Product Usage Instructions
Before Use:
- Remove the label from the display.
- Your Vicks SpeedRead Digital Thermometer is a 3-in-1 thermometer for oral, rectal, or underarm use. Whichever method is used, it is recommended that for 15 minutes prior to use, avoid eating or drinking any liquids, exercising, taking showers or baths, or smoking.
PROBE COVERS
Disposable probe covers are provided with your Vicks SpeedRead Digital
Thermometer. Place a cover on the probe tip each time the thermometer is used
to help prevent spread of germs. Additional probe covers can be purchased at
most drug stores or pharmacy departments.
OPERATING YOUR Vicks SpeedRead DIGITAL THERMOMETER
TURNING THE UNIT ON
- Turn unit on by pressing the On/Off button (Fig. 1).
- A beep will sound and the display will flash Red/Yellow/Green for 1 second.
- Wait for unit to get ready
- The display will perform a self-test (Fig. 2).
- The display will show last measurement for 2 seconds (Fig. 3).
- After about 5 seconds, the display will show it’s ready (Fig. 4).
SELECTING A TEMPERATURE LOCATION
Oral Use
- It is suggested to use a probe cover for Oral Use to prevent the spread of germs.
- Place thermometer under the tongue. It is important to place the tip of the thermometer well under the tongue to get a good, accurate reading. (Fig. 5) Place sensor tip in areas marked with “3”. Keep mouth closed and sit still to help ensure an accurate measurement.
- When the peak temperature is reached (usually 9 seconds), 5 beep signals will sound and the “°F” or “°C” sign will stop flashing. The temperature is now ready to read and will not change when the thermometer is removed.
- Dispose of used probe cover and wash the thermometer as recommended.
Under-the-arm (Axillary) Use
This method is used for babies and young children.
-
Wipe the underarm with a towel.
-
Place the probe tip under the arm so the tip is touching the skin and position your arm next to your body (Fig. 6) . With a young child, it is sometimes helpful to hug the child to keep their arm next to their body. This ensures that the room air does not affect the reading.
-
When the peak temperature is reached (usually 11 seconds), 5 beep signals will sound and the “°F” or “°C” sign will stop flashing. The temperature is now ready to read and will not change when the thermometer is removed.
Note: This method produces a temperature 1° lower than a temperature taken orally. -
Wash the thermometer as recommended.
Rectal Use
Commonly used for babies, young children, or when it is difficult to take an
oral or underarm temperature.
-
Cover the thermometer’s tip with a probe cover and lubricate with a water-soluble jelly for easier insertion. Do not use petroleum jelly. Read the label of the lubricant to be sure you are using the right kind.
-
Lay the patient on his/her side. If the patient is an infant, the proper position for a baby is to lay on its stomach with legs hanging down, either across your knees or at the edge of a bed or changing table. This positions the infant’s rectum for safe and easy insertion of the thermometer.
-
Gently insert the tip of the thermometer NO MORE THAN 1/2 inch into the rectum. If you detect resistance, stop. Hold the thermometer in place during measurement.
-
When the peak temperature is reached (usually 10 seconds) 5 beep signals will sound and the “°F” or “°C” sign will stop flashing. The temperature is now ready to read and will not change when the thermometer is removed.
Note: This method produces a temperature 1° higher than a temperature taken orally. -
Dispose of used probe cover and wash the thermometer as recommended.
Preparation:
- Avoid eating or drinking any liquids, exercising, takingshowers or baths, or smoking for 15 minutes prior to use.
FEVER INSIGHT FEATURE
Fever InSight helps you to better understand the meaning of your child’s temperature with the color indicated on the display. The screen displays Green if no fever, Yellow when the temperature is slightly elevated and a Red alert for fever.
Color | Range (°F) | Range (°C) | Meaning |
---|---|---|---|
Green | 97.0-98.9 | 36.1-37.1 | Acceptable |
Yellow | 99.0-100.9 | 37.1-38.3 | Elevated |
Red | 101+ | 38.3+ | Possible High Fever |
TURNING THE UNIT OFF
Turn the thermometer off by pressing the On/Off button. If you forget to turn
it off, the thermometer will automatically turn off after approximately 1 1/2
minutes.
CLEANING INSTRUCTIONS
- Clean the probe tip by washing with soap and warm water or by disinfecting with rubbing alcohol (70% isopropyl alcohol).
- Wipe dry with soft cloth. •
- NOT BOIL OR CLEAN IN DISHWASHER. This will cause the thermometer to no longer function and will void the warranty.
- Do not wash the unit with any thinner or chemical solvent.
CHANGING THE BATTERIES
The Vicks SpeedRead Digital Thermometer features a long life battery. When the “ ” appears and flashes in the center top of the display, the battery is exhausted and needs replacing.
- Using a coin, unlock the battery cover and carefully remove the battery with a non-metallic
- Replace the battery with a 3V, CR1225 silver oxide type or Insert the new battery with the positive (+) side facing the battery cover.
- Carefully replace the battery cover and, using a coin, tighten the cover.
To protect the environment, dispose of empty batteries at appropriate collection sites according to national or local regulations. Keep out of reach of young children, elderly and pets.
SPECIFICATIONS
- Battery Life: More than 300 measurements or approximately 2 years if used every other day.
- Temperature Range: 89.6-109.2°F. If less than 89.6°F, “Lo” is displayed. If more than 109.2°F, “Hi” is displayed. “
- BPA Free” Implies:
- Plastics used to make the thermometer are BPA Free
- A comprehensive audit to ensure a BPA Free process
- A screening test based on acceptance criteria
- Beeper: Unit will beep for approximately 8 seconds when peak temperature is reached. For temperatures over 101.0°F, the audible Fever Signal will sound 5 times.
- Error Messages: The display will read “Err” when a malfunction occurs and the unit will power off after 1 minute.
- Accuracy in Water-bath: +/-0.2°F between 96.0-107.0°F at room temperature of 71°F.
TEST PROTOCOL (Laboratory use only)
- Place thermometer into a stable liquid bath with a temperature set above 95°F. The tip of the thermometer should be approximately 8 inches (2cm) below the surface.
- Wait for 10 seconds, then turn thermometer on by pressing the blue “On / Off”
- When the measurement is completed (approximately 8 seconds), record the temperature
1 YEAR LIMITED WARRANTY
You should first read all Instructions before attempting to use this product.
- This 1 year limited warranty applies to repair or replacement of product found to be defective in material or This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.
- At its option, Kaz will repair or replace this product if it is found to be defective in material or
- This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction Call us toll-free at 1-800-477-0457 or e-mail: consumerrelations@kaz.com. Please be sure to specify a model number.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE PRODUCT OR PERSONAL INJURY.
If you have any further questions or concerns about using the Vicks SpeedRead Digital Thermometer, please contact our toll-free Consumer Relations Line at 1-800-477-0457 or email us at consumerrelations@kaz.com. 2016 All rights reserved. Kaz USA, Inc., a Helen of Troy Company • Marlborough, MA 01752 • www.vicksthermometers.com
This product is distributed under license from The Procter & Gamble Company. VICKS and other associated trademarks are owned by The Procter & Gamble Company. Fever InSight and ComfortFlex are registered trademarks owned by Helen of Troy Limited. Protected by U.S. patents D535,898 and 5829878
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>