This humidifier adds water vapor to the surrounding air which may help the user breathe better.
If you have any questions about the operation of your Vicks EasyCare+ Top Fill Filter Free Humidifier call our toll-free Consumer Relations line at 1-800-VAPOR-1-2 or contact us at www.VicksHumidifiers.com/contact- us.

IMPORTANT!
READ AND SAVE THESE INSTRUCTIONS

Important Safety Instructions

READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS BEFORE USING THIS HUMIDIFIER

WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO PEOPLE, INCLUDING THE FOLLOWING:

  1. The appliance should ALWAYS be placed on a firm, flat, level waterproof surface at least four feet (1.2m) away from bedside, 12 inches (30 cm) from the wall and out of reach of children and pets. Be sure the humidifier is in a stable position and the power cord is away from heated surfaces and out of the way to prevent the humidifier from being overturned.

  2. The humidifier should not be left unattended in a closed room. Leave room door partly open. DO NOT aim
    Mist Outlet directly at children, walls or furniture.

  3. Before using the humidifier, extend the cord and inspect for any signs of damage. DO NOT use the unit if the cord has been damaged. DO NOT operate with power cord coiled or with twist tie in place.

  4. CAUTION: To avoid fire or electric shock hazard, plug the humidifier directly into a 120V AC electrical outlet.
    To avoid risk of fire, electric shock or personal injury, DO NOT use an extension cord or power strip.

  5. The humidifier should ALWAYS be unplugged and emptied when not in operation or while being cleaned. Shut off and unplug humidifier before moving.
    DO NOT move or tilt humidifier while it is in operation. Plug and unplug unit with dry hands. NEVER pull by cord.

  6. DO NOT operate the humidifier without water. Turn off and unplug unit when tank is empty.

  7. Humidifier requires regular cleaning.
    Refer to and follow cleaning instructions.

  8. DO NOT operate outdoors; this humidifier is intended for indoor residential use only.

  9. DO NOT cover or insert objects into any openings on the unit.

  10. DO NOT block intake or output vents.

  11. DO NOT attempt to repair or adjust any electrical or mechanical functions on this humidifier. Doing so will void your warranty.

  12. DO NOT place in direct sunlight, high temperature areas or near computers or sensitive electronic equipment.

  13. DO NOT touch the nebulizer while the unit is plugged in as burns could result.

  14. DO NOT touch skin with exposed VapoPad or place VapoPad on furniture, fabric, bedding or plastic.

  15. DO NOT add any essential oils, or medications (e.g. Kaz Inhalant or Vicks VapoSteam) into Mist Outlet, Base, Water Reservoir or Water Tank. ONLY add Vicks VapoSteam or essential oils to the medicine cup.

  16. For residential use only.

  17. Only use this humidifier with the provided adapter.

  18. WARNING:
    CHOKING HAZARD – Small parts. Not for children under 3 yrs.

SAVE THESE INSTRUCTIONS

This device complies with Part 18 of the FCC rules (US only).

WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply within the limits for Consumer ISM equipment, pursuant to Part 18 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference with radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio TV technician for help.

How it Works

The Vicks EasyCare+ Top Fill Filter Free Humidifier is designed to quietly provide visible cool mist and comforting cough and cold relief. This filter free humidifier has a built-in nebulizer that quietly vibrates the water at ultrasonic frequency to break the water droplets into a fine, cool mist that you can see and feel.
The mist helps reduce respiratory and dry air discomforts by increasing humidity levels to help you breathe better and sleep more comfortably. Enhance your humidification experience by using Vicks VapoSteam or Vicks VapoPads for added comfort.

Components

Components

Accessories (Not Included)

The following accessories work great with your humidifier:

Vicks VapoSteam

US Only: When added to the medicine cup, it produces soothing menthol vapors to help provide medicated relief of coughs from colds. Enjoy up to 8 hours of soothing comfort per dose.

Canada Only: When added to medicine cup, Vicks VapoSteam produces soothing menthol mist.

Essential Oil Compatible

When added to the medicine cup, you can enjoy your favorite essential oils. This device is not a diffuser – the oil does not come in contact with water and is passively evaporated into the air. Enjoy the calm.

Vicks VapoPads (One menthol VapoPad sample included)
Use Vicks VapoPads with your humidifier for soothing vapors. Enjoy up to 8 hours of soothing comfort per pad. Choose from three scents: Soothing Menthol Vapors, Comforting Sleepy Time Comfort (eucalyptus, rosemary and lavender) and Calming Vapors (Menthol and Lavender).

Protec® Antimicrobial Cleaning Products (Not Included)
These products feature an antimicrobial, Rhino Guard™, that helps keep your humidifier cleaner, longer. Simply drop in the tank for fresh, clean mist!
Benefits of using these products include:

  • Kills up to 99% of odor causing bacteria
  • Keeps cleaning for up to 30 days
  • Contains no harmful chemicals

Accessories available at retailers and at www.VicksHumidifiers.com.

Setting Up Your Humidifier

Setting Up Your Humidifier
Setting Up Your Humidifier

  1. Remove packaging materials. Locate Float Paddle and set aside.This is required for operation. Keep instructions.

  2. Remove twist tie and extend power cord.

  3. Place on a firm, level, water resistant surface a minimum of 12 inches (30cm) from any walls.

  4. Plug adapter cord into the port on the back of the unit.

  5. Float Paddle Installation
    Line up the Float Paddle with the dashed line float paddle shape on the bottom of the Reservoir. Place paddle over brackets. It does NOT snap in, it is simply set in place. The paddle can be gently placed in the brackets.
    CAUTION: IMPROPER PLACEMENT OF THE FLOAT PADDLE COULD RESULT IN LEAKING OR WATER NOT FEEDING TO THE RESERVOIR.
    NOTE: YOU HAVE TWO OPTIONS FOR FILLING YOUR HUMIDIFIER’S WATER TANK: UNDER THE FAUCET AT THE SINK, OR WITH A PITCHER OF WATER AT THE HUMIDIFIER.

  6. If filling at the sink, remove Tank using handles on the sides of the Base, carry to sink and fill with cool water.
    OR If filling at the humidifier, ensure Tank is securely seated on Base. Open Lid Flap and fill with cool water using a water pitcher.
    NOTE: FILL TANK WITH COOL WATER. DO NOT FILL WITH WARM OR HOT WATER. DO NOT ADD ESSENTIAL OILS, MEDICATIONS, OR INHALANT LIQUIDS, SUCH AS VICKS VAPOSTEAM, TO THE TANK, ONLY THE MEDICINE CUP. DOING SO COULD CAUSE DAMAGE TO THE HUMIDIFIER AND VOID THE WARRANTY.

  7. Close the Lid Flap.

  8. If filled at the sink, carry the full Tank back using two hands and place back on Base.
    CAUTION: USE CARE WHEN HANDLING WATER TANK TO AVOID UNNECESSARY IMPACT. BANGING OR DROPPING THE WATER TANK COULD RESULT IN DAMAGE TO THE TANK THAT WILL CAUSE LEAKING.

Operating Humidifier

  1. Plug Adapter Cord into the port on the back of the unit.
    With the Power Knob in the off position, plug humidifier into a polarized 120V outlet.
    CAUTION: TO AVOID ELECTRIC SHOCK DO NOT PLUG HUMIDIFIER INTO OUTLET WITH WET HANDS.

  2. Output: Turn the Power Knob clockwise to highest setting. It is recommended you set the output to high until you reach a comfortable humidity level.

  3. Position humidifier to direct mist output away from walls, furniture and bedding.

  4. Humidity Level: When a comfortable humidity level is reached, turn Power Knob to a lower setting. A comfortable humidity level is between 40–60%.

To monitor your humidity level, use a humidity monitor such as the Vicks V70 (not included)

If you notice condensation on the walls, windows or around unit, your humidity level is too high. Turn humidifier off.

Using Vicks Vapo Steam or Your Own Essential Oils (Not Included)

This humidifier features a Medicine Cup that can be used with your favorite essential oil or liquid inhalant (like Vicks VapoSteam) for added enjoyment.
The cup is heated to help evaporate the oil. This is not a diffuser – the oil does not meet the water but is passively evaporated into the air. Essential oil and inhalant are not included.

  1. Turn off the humidifier.
  2. Add 1 Tablespoon Vicks VapoSteam or a few drops of essential oil to the Medicine Cup. Turn on the humidifier.
  3. To clean the Medicine Cup wait 5 minutes after turning the unit off. Then gently wipe residue from the cup with a soft cloth.

WARNING: DO NOT ADD ESSENTIAL OILS, LIQUID INHALANTS OR ANY ADDITIVES TO THE WATER. DOING SO CAN DAMAGE THE HUMIDIFIER AND VOID THE WARRANTY.

Using Vicks VapoPads

Using Vicks VapoPads

Your humidifier can be used with Vicks VapoPads to provide up to 8 hours of soothing vapors.
One free sample of the menthol VapoPad is included with your humidifier. To use your unit with Vicks VapoPads:

  1. Open VapoPad Door.
  2. Open VapoPad by tearing notch on pad bag. DO NOT touch pad with hands. If pad is touched DO NOT rub face or eyes as it may cause irritation.
  3. Insert Vicks VapoPad with angled end facing towards the product. Up to two VapoPads can be inserted. Close door.
  4.  After 8 hours, discard VapoPad.
    To continue using VapoPads, repeat steps 1-4

VapoPad Recommended Usage:

  • Not recommended for infants under 10 lbs (4.5 kg).
  • For children between 10-22 lbs (4.5-10 kg ) do not use more than 2 pads in a 24 hr period.

Sample VapoPad ingredients: Eucalyptus Oil, Menthol, Glycol, Cedar Leaf Oil & Others.

NOTE: ALWAYS REFERENCE VAPOPAD PACKAGING FOR RECOMMENDED USAGE INSTRUCTIONS AND WARNINGS.

Water Quality and Your Humidifier

High mineral content in your water, also known as “hard water” may cause a white mineral residue to accumulate on surfaces in the room near the humidifier. This mineral residue is commonly referred to as “White Dust.” The higher the mineral content or hardness of your water, the greater the potential that you may have white dust. “White Dust” is not a result of a defect or flaw in the humidifier. It is a result of the amount of minerals suspended in the water you are using. If you live in a hard water area, the use of distilled water will minimize the production of white dust.

Weekly Cleaning

It is recommended that you empty the Water Tank and Reservoir when the unit is not in use, rinse and let them air dry. To keep your humidifier running efficiently, clean it regularly. Weekly cleaning is recommended. To properly clean your humidifier we recommend the separate processes of Scale Removal and Disinfecting shown below. THESE TWO PROCESSES MUST BE PERFORMED SEPARATELY.

CAUTION: BEFORE MOVING HUMIDIFIER BASE, TURN OFF, UNPLUG AND EMPTY THE TANK. All maintenance should be done in the kitchen or bathroom on a water resistant surface near a faucet. DO NOT wash any components of this humidifier in the dishwasher.

Instructions for Scale Removal

Instructions for Scale Removal 

  1. Turn off and unplug the humidifier.

  2. Remove any accessories, and wipe any remaining residue from the Medicine Cup.

  3. Remove Water Tank from Base. Holding the Base, empty water from the Reservoir.

  4. Pour a minimum of 1 cup (1/4 liter) of undiluted distilled white vinegar in the Water Tank. Gently swish vinegar around in the Tank to wet entire inside of Tank.

  5. Place Tank on Base. Vinegar will drain into the Water Reservoir and loosen mineral buildup (scale) in the Reservoir and bottom of the Water Tank. There should be enough vinegar to cover the bottom inside of the Tank.

  6. Soak for 20 minutes, then remove Water
    Tank and slowly empty vinegar into sink.
    Rinse with tap water until the smell of vinegar is gone.

  7. Empty vinegar from Base and Reservoir area.

  8. Remove Float Paddle from Reservoir by lifting on the sides. Wipe Float Paddle and Reservoir area with a soft cloth to remove loosened minerals. If mineral build up is stubborn on the nebulizer, loosen with a soft tooth brush. Rinse the base making sure water does not enter the vented fan or power knob. Wipe dry with a soft cloth.
    NOTE: NEBULIZER IS FRAGILE. DO NOT APPLY EXTREME PRESSURE.

  9. Place Float Paddle back in Reservoir. Position in place. For detailed instructions, refer to the Float Paddle Installation section.

CAUTION: IMPROPER PLACEMENT OF THE FLOAT PADDLE COULD RESULT IN LEAKING OR WATER NOT FEEDING TO THE RESERVOIR.

CAUTION: DO NOT SUBMERGE BASE IN WATER. DOING SO WILL DAMAGE THE HUMIDIFIER AND VOID THE WARRANTY.

Instructions for Disinfecting

Instructions for Disinfecting

Follow Steps 1-3 in Scale Removal Instructions in previous section.
NOTE: BLEACH MAY STAIN CLOTHES. IT IS RECOMMENDED THAT YOU WEAR RUBBER GLOVES DURING THIS PROCESS TO PROTECT YOUR HANDS.

  1. Add 1/2 teaspoon (2.5mL) of bleach to 1/2 gallon (1.9L) of water. Pour the bleach solution into the Tank wetting the entire inside with the bleach solution. Place the Mist Nozzle inside to also disinfect.
    NOTE: USING MORE THAN 1 TEASPOON OF BLEACH TO 1 GALLON (3.8L) OF WATER MAY RESULT IN DAMAGE TO THE HUMIDIFIER.

  2. Place Tank on Base. Bleach solution will drain into the Water Reservoir.

  3. Soak for 20 minutes, then remove the Water Tank and slowly empty bleach solution into sink. Wearing rubber gloves carefully remove the Nozzle. Rinse Tank and Nozzle with water until the smell of bleach is gone.

  4. Empty bleach solution from Base an Reservoir area. Carefully rinse, making sure water does not enter the vented fan or power knob, until the smell of bleach is gone.

  5. Remove Float Paddle from Reservoir by lifting on the sides and rinse.

  6. Using a soft cloth wipe the Base, VapoPad Door, Medicine Cup, Chimney, Float Paddle, and Mist Nozzle.

  7. Place Float Paddle back in Reservoir. Position in place. For detailed instructions, refer to the Float Paddle Installation section.

CAUTION: IMPROPER PLACEMENT OF THE FLOAT PADDLE COULD COULD RESULT IN LEAKING OR WATER NOT FEEDING TO THE RESERVOIR.

End-Of-Season Care And Storage

Follow the CLEANING instructions when the humidifier will not be used for at least one week, or it is the end of the season. At the end of the season, remove any accessories used with the humidifier and allow the humidifier and accesories to dry completely before storing.

DO NOT store with water inside the Base, Water Reservoir or Tank.

Troubleshooting

If your humidifier is not working properly, refer to the following:

Problem Possible Cause Solution
Power Switch is set to On and Indicator Light is Off • Unit not plugged in
• No power at outlet Plug unit in

• Check circuits, fuses, test outlet
Noticeable dripping sound| Machine is stabilizing| No action is required. The noise level will decrease on its own.
Little or no mist is produced| • No water in Tank
• Unit is not level
• Mineral deposits on Nebulizer
• Water Tank was washed with detergent| Fill Water Tank
• Place on a level surface
• Follow Cleaning Instructions on Pages 6-8
• Rinse thoroughly with clean water
Water overflows from Reservoir| Tank may be leaking| Check the Tank for leaks and replace if necessary
Condensation forms around humidifier or windows| Mist Intensity is set too high for room size or
pre-existing humidity level| Decrease mist output to low setting, open door to the room or turn the unit off
• Float Paddle is floating in the Base
Water leaking from Base or Reservoir| Float Paddle not placed correctly
• Unit may not be on level surface
• Plunger is sticking or damaged
• Tank is cracked
• Plunger may have foreign
material stuck under the Tank
Gasket| Ensure Float Rod properly placed on brackets over the dotted line indicator
• Push and release Plunger to be
sure it is moving freely
• Inspect tank for damage;
contact Consumer Relations
• At sink, push and release Plunger system so water may flow

NOTE: FAILURE TO KEEP THIS UNIT CLEAN FROM MINERAL DEPOSITS NORMALLY CONTAINED IN ANY WATER SUPPLY WILL AFFECT THE EFFICIENCY OF OPERATION OF THIS UNIT. CUSTOMER FAILURE TO FOLLOW THESE INSTRUCTIONS MAY VOID THE WARRANTY.

Consumer Relations

For questions, technical support or to order replacement parts, contact Consumer Relations.
Call us toll-free at: 1-800-VAPOR-1-2 (1-800-827-6712)
Hours: Mon-Fri 8:00AM-6:00PM EST
Connect with an agent at: www.VicksHumidifiers.com/contact- us
Or visit our website at: www.VicksHumidifiers.com
Please be sure to specify model number.

Electrical Ratings

Electrical Rating: 24V , 28.8W

Capacity

0.6 gallons (~2.25 L)

WARRANTY

2 YEAR LIMITED WARRANTY

YOU SHOULD FIRST READ ALL INSTRUCTIONS BEFORE ATTEMPTING TO USE THIS PRODUCT.

A. This 2 year limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.
B. At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship.
C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.
D. This warranty does not cover the filters, pre-filters, UV bulbs or other accessories (if included) except for material or workmanship defects.

Call us toll-free at 1-800-827-6712 or https://www.vickshumidifiers.com/contact-us

Please be sure to specify a model number. In some scenarios, you must prepay shipping charges.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE HUMIDIFIER TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE BASE OR TAMPER WITH THE POWER KNOB YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

© 2022 All Rights Reserved.
Manufactured by: Kaz USA, Inc., a Helen of Troy Company 400 Donald Lynch Blvd., Suite 300, Marlborough, MA 01752 Imported by: Kaz Canada, Inc., a Helen of Troy Company, 6700 Century Avenue, Suite 210, Mississauga, Ontario L5N 6A4 Certain trademarks used under license from The Procter & Gamble Company or its affiliates.
Protec® is a registered trademark owned by Helen of Troy Limited.
Rhino Guard is a registered trademark of K2 Concepts Inc., Atlanta GA.
To contact us call 1-800-VAPOR-1-2 (1-800-827-6712) or visit our website at www.VicksHumidifiers.com
Made in China.

Company Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals