VICKS VUL530 Series NaturalCare Ultrasonic Humidifier Diffuser VapoPads and Nitetime-Light User Manual
- June 6, 2024
- Vicks
Table of Contents
- Vicks VUL530 Series Humidifier
- Vicks NaturalCare™ Humidifier (Model VUL530)
- VUL530 Series Accessories (Not Included)
- Setting Up Your Humidifier
- Operating
- Using Vicks VapoPads
- Operating the Nitetime-Light by Touching the
- Operating with Essential Oils
- Water Quality and Your Humidifier
- Weekly Cleaning
- End-Of-Season Care And Storage
- Consumer Relations
- Troubleshooting
- 2 Year Limited Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NaturalCare™
Ultrasonic Humidifier – Diffuser – VapoPads & Nitetime-Light
Use And Care Manual
• No filters required | • Whisper quiet |
---|---|
• Essential oil diffuser | • Use with Vicks VapoPads |
• Calming color changing light | • Auto Shut Off |
This humidifier adds water vapor to the surrounding air helping the user to breathe better. If you have any questions about the operation of your Vicks NaturalCare™ Humidifier, call our toll-free Consumer Relations line at 1-800-VAPOR-1-2 or e-mail us at ConsumerRelations@HelenofTroy.com.
IMPORTANT!
READ AND SAVE THESE INSTRUCTIONS
VUL530 Series
Important Safety Instructions
READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS BEFORE USING THIS
APPLIANCE
WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE
FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, AND INJURY TO PERSONS,
INCLUDING THE FOLLOWING:
- The appliance should ALWAYS be placed on a firm, flat, waterproof surface at least four feet (1.2 m) away from the bedside, 12 inches (30 cm) from the wall, and out of reach of children and pets. Be sure the appliance is in a stable position and the power cord is away from heated surfaces and out of the way to prevent the humidifier from being a tripping hazard doing so may result in personal injury or property damage.
- The appliance should not be left unattended in a closed room. Leave room door partly open. DO NOT aim Mist Outlet directly at walls, furniture, and bedding.
- Before using the appliance, extend the cord and inspect for any signs of damage. DO NOT use the unit if the cord has been damaged. DO NOT operate with power cord coiled or twist tie in place.
- The appliance has a polarized plug (one blade is wider than the other) as a safety feature. This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
- CAUTION To avoid fire or electric shock hazards, plug the appliance directly into a 120V AC electrical outlet. To avoid the risk of fire, electric shock, or personal injury, DO NOT use an extension cord or power strip.
- The appliance should ALWAYS be unplugged and emptied when not in operation or while being cleaned. Shut off and unplug the humidifier before moving. DO NOT move or tilt the humidifier while it is in operation. Plug and unplug the unit with dry hands. NEVER pull by the cord.
- The appliance requires regular cleaning. Refer to and follow cleaning instructions.
- DO NOT operate outdoors; this appliance is intended for indoor residential use only.
- DO NOT cover or insert objects into any openings on the unit.
- DO NOT attempt to repair or adjust any electrical or mechanical functions on this appliance. Doing so will void your warranty.
- DO NOT place in direct sunlight, high-temperature areas, or near computers or sensitive electronic equipment.
- DO NOT touch the nebulizer while the unit is plugged in as burns could result.
- DO NOT touch skin with exposed VapoPad or place VapoPad on furniture, fabric, bedding, or plastic.
- DO NOT add any medications (e.g. Kaz Inhalant or Vicks VapoSteam) into Mist Outlet, Base, Water Reservoir, or Water Tank.
Vicks VUL530 Series Humidifier
This device complies with Part 18 of the FCC rules.
Warning: Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user’s authority to operate
the equipment. This equipment has been tested and found to comply with the
limits for Consumer ISM equipment, pursuant to Part 18 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference with radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the users are encouraged to try to correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio TV technician for help.
Vicks NaturalCare™ Humidifier (Model VUL530)
VUL530 Series Accessories (Not Included)
The following optional accessories work great with your humidifier.
Vicks VapoPads (One menthol VapoPad sample included) Use Vicks VapoPads
with your humidifier for soothing vapors. Enjoy up to 8 hours of soothing
comfort per pad. Choose from three scents: Soothing Menthol Vapors,
Comforting Sleepy Time Comfort (eucalyptus, rosemary, and lavender), and
Calming Vapors (menthol and lavender).
Protec® Antimicrobial Cleaning Products (Not Included)
Why use a Protec Humidifier Cleaning Ball? Humidifier tanks hold water which
is an ideal breeding ground for microorganisms. This can cause odor and
buildup and may require more frequent cleaning. The Protec Humidifier Cleaning
Ball or Fish:
- Kills up to 99% of odor-causing bacteria
- Keeps cleaning for 30 days
- Contains no harmful chemicals
Protec® Demineralization Cartridge
This humidifier works with a Demineralization Cartridge that helps remove
minerals from the water. This helps prevent the build-up of minerals (“white
dust”) that can occur in hard water areas. If you live in a hard water area,
we recommend the use of this demineralization cartridge if not using distilled
water
Setting Up Your Humidifier
- Remove packing materials. Keep instructions.
- Remove twist tie and extend the power cord.
- Place on a firm, level, water-resistant surface a minimum of12” (30cm) from any walls.
Filling/Refilling
NOTE: Tank should be carried using two hands. One hand uses a carrying handle
located on a tank top and the other hand supports the base of the tank.
This Humidifier holds .6 gallons (1.9L) of water (tank and reservoir
combined).
Always turn the humidifier off before removing the Water Tank.
- Remove Tank and turn upside down.
- Remove Tank Cap in the direction of the open lock symbol.
- Fill Tank with cool water. Do not fill with warm or hot water.
- Securely replace Tank Cap, aligning arrow to lock symbol.
- Place Tank back on Base.
CAUTION: USE CARE WHEN HANDLING WATER TANKS TO AVOID UNNECESSARY IMPACT. BANGING OR DROPPING THE WATER TANK COULD RESULT IN DAMAGE TO THE TANK THAT WILL CAUSE LEAKING.
Operating
-
Power: With the Power Knob in the off position, plug the humidifier into a polarized 120V outlet.
Caution: To avoid electric shock do not plug the humidifier into an outlet with wet hands. -
Humidity Output: Turn the Power Knob to the highest setting.
-
Humidity Level: When a comfortable humidity level is reached turn Power Knob to a lower setting. A comfortable humidity level is between 40-60%.
To monitor your humidity level use a humidity monitor such as the Vicks V70 or V70-CAN model.
If you notice condensation on the walls, windows, or around the unit, your humidity level is too high.
Turn humidifier off, or lower humidity output level. -
180° mist nozzle, directs mist output away from walls, furniture, and bedding.
CAUTION: BEFORE MOVING THE HUMIDIFIER, TURN IT OFF, UNPLUG AND EMPTY THE HUMIDIFIER.
Using Vicks VapoPads
Your humidifier can be used with Vicks VapoPads to provide up to 8 hours of soothing vapors. One free sample of the Vicks Soothing Menthol VapoPad is included with your humidifier. To use your unit with Vicks VapoPads:
- Open VapoPad Door by pressing the button on the left side of the Scent Pad area.
- Open VapoPad by tearing notch on pad bag. DO NOT touchpad with hands. If the pad is touched DO NOT rub the face or eyes as it may cause irritation.
- Insert up to 2 Vicks VapoPads with the angled ends facing towards the product. Close door.
- After 8 hours, discard scent pads.
To continue using scent pads, repeat steps 1-4.
VapoPad Recommended Usage:
- Not recommended for infants under 10 lbs (4.5 kg).
- For children between 10-22 lbs (4.5-10 kg ) do not use more than 2 pads in a 24 hr period.
Scent Pad Ingredients: VSP-19, VSP-19-CAN: Eucalyptus Oil, Menthol, Glycol, Cedar Leaf Oil & Others
Operating the Nitetime-Light by Touching the
- 1st Press: Color changing Nitetime-Light turns ON
- 2nd Press: Light stops on the current color
- 3rd Press: Turns Nitetime-Light function OFF
You can Press and Hold to dim the light at any time, there are 3 dimming
levels
Note: The nighttime light can be used with or without the use of the
humidifier. The Nitetime-Light will remain on, even if the humidifier has been
turned off. Touch the lightbulb icon to turn the nighttime light off.
Operating with Essential Oils
To use essential oils in your humidifier, add a few drops of your favorite essential oil(s) to the water in the Tank and replace the Cap. DO NOT operate without water. ONLY use 100% natural essential oils, use of other oils may cause damage to the Humidifier.
ALWAYS reference the essential oil labeling for usage and dosage
instructions.
NOTE: The Tank and Reservoir are made of oil-proof materials but other
parts of the Humidifier are not. Essential oils should only be allowed in the
Tank and Reservoir. If any oils spill outside of the Tank or Reservoir, be
sure to wipe down gently with a wet paper towel and then dry gently with a dry
paper towel.
Water Quality and Your Humidifier
High mineral content in your water, also known as “hard water” may cause a
white mineral residue to accumulate on surfaces in the room near the
humidifier. This mineral residue is commonly referred to as “white dust.”
The higher the mineral content or hardness of your water, the greater the
potential that you may have white dust.
“White dust” is not a result of a defect or flaw in the humidifier. It is a
result of the number of minerals suspended in the water you are using.
If you live in a hard water area the use of distilled water will minimize the
production of white dust.
Weekly Cleaning
To properly clean your humidifier we recommend the separate processes of Scale
Removal and Disinfecting shown below. These two processes must be performed
separately.
All maintenance should be done in the kitchen or bathroom on a water-resistant
surface near a faucet. DO NOT wash any components of this humidifier in
the dishwasher.
Instructions for Scale Removal
-
Turn off and unplug the humidifier.
-
Remove Water Tank from Base. Remove Tank Cap, taking care that the rubber Cap Seal does not come off. Empty water from Water Tank and Base.
-
If Antimicrobial Cleaning Product is installed, remove Antimicrobial Cleaning Product and set it aside. DO NOT clean Antimicrobial Cleaning Product. This will damage the Antimicrobial Cleaning Product.
-
Add 2 cups of undiluted distilled white vinegar to Water Tank. Replace Tank Cap and swish vinegar solution around in Tank. Place Tank on Base. The vinegar solution will drain into Water Reservoir and loosen mineral buildup (scale) on Nebulizer and Float as they soak in the solution. It will also loosen the scale on the bottom of the Water Tank.
-
Soak for 15-20 minutes.
-
After soaking, unlock the Tank Cap and pour the solution out into the sink. Pour the solution from Water Reservoir out in the sink. Wipe Nebulizer and Float with a soft cloth to remove loosened mineral deposits.
-
Rinse Water Reservoir and Water Tank until the smell of vinegar (for the Scale Removal process) or bleach solution (for Disinfecting process) is gone. Make sure water does not enter the fan opening (vented opening on right side of Reservoir) or Power Knob.
CAUTION: DO NOT SUBMERGE THE BASE IN WATER. DOING SO WILL DAMAGE THE HUMIDIFIER AND VOID THE WARRANTY.
Instructions for Disinfecting
Follow Steps 1-3 in Scale Removal Instructions in the previous section.
For Step 4: Add ½ tsp of bleach to ½ gallon (1.9L) of water and add to
Tank. Replace Tank Cap. Swish solution around in Tank. Place Tank on Base.
Bleach solution will drain into Reservoir and will disinfect Reservoir and
other components as they soak.
NOTE: Using more than ½ tsp of bleach to ½ gallon of water may result in
damage to your humidifier.
See steps 5-7 in Scale Removal Instructions in the previous section to
complete Disinfecting process.
NOTE: DO NOT mix vinegar and bleach solutions together. Scale Removal and
Disinfecting must be done separately.
End-Of-Season Care And Storage
Follow the CLEANING instructions when the humidifier will not be used for
at least one week, or at the end of the season.
At the end of the season, remove any accessories used with the humidifier and
allow the humidifier and accessories to dry completely before storing.
DO NOT store water inside the Base, Reservoir, or Tank.
Pack unit safely and store in a cool, dry location.
Consumer Relations
TO ORDER REPLACEMENT PARTS CONTACT CONSUMER RELATIONS
Call us toll-free at: 1-800-VAPOR-1-2
E-mail:
ConsumerRelations@HelenofTroy.com
Or visit our website at:
www.VicksHumidifiers.com
Please be sure to specify model number VUL530.
Electrical Ratings
The Vicks VUL530 Series model is rated at 120V, 60 Hz 25W.
Troubleshooting
If your humidifier is not working properly, refer to the following:
Problem | Possible Cause | Solution |
---|---|---|
Power Knob is turned “on” and the power light is off | • Unit not plugged in | |
• No power at outlet | • Plug unit in |
• Check home circuits, fuses, test outlet
Power is on and little or no mist is produced| • No water in the tank
• Unit is not level
• Mineral deposits on Nebulizer
• Power setting may be too low
• Water Tank or Base was
washed with detergent| • Fill Water Tank with cool water
• Place on a level surface
• Clean Nebulizer (refer to Weekly Care & Cleaning instructions)
• Turn the Power Knob to increase output
• Rinse thoroughly with clean water until there is no foam or smell of
cleaning solution
Water overflows
from Reservoir| • Tank may be damaged
• Tank Cap is not tight
• Tank Cap Seal may be missing| • Check the Tank for any cracks or damage.
and replace if necessary
• Close Tank Cap to lock position
• Check to see if Cap Seal is attached to Tank Cap. If not, contact Consumer
Relations
Condensation forms around humidifier or on windows and walls| • Mist
Intensity is set too high for room size or pre-existing humidity level
• Humidifier may be too close to wall or window| • Decrease mist output to a
lower setting or open door to the room
• Move humidifier away from wall or point Mist Outlet away from wall or
window
No Nitetime-Light
display| • Light Button is not pressed| • Press the Light Button to turn on
the color-changing light and press a second time to stop on the current color
NOTE: Failure to keep this unit clean from mineral deposits normally contained in any water supply will affect the efficiency of operation of this unit. Customer failure to follow these instructions may void the warranty.
2 Year Limited Warranty
YOU SHOULD FIRST READ ALL INSTRUCTIONS BEFORE ATTEMPTING TO USE THIS
PRODUCT.
A. This 2-year limited warranty applies to repair or replacement of
products found to be defective in material or workmanship. This warranty does
not apply to damage resulting from commer cial, abusive, unreasonable use,
or supplemental damage. Defects that are the result of normal wear and tear
will not be considered manufacturing defects under this warranty. KAZ IS NOT
LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS
PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. Some
jurisdictions do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied warranty lasts, so
the above limitations or exclusions may not apply to you. This warranty gives
you specific legal rights, and you also may have other rights which vary from
jurisdiction to jurisdiction. This warranty applies only to the original
purchaser of this product from the original date of purchase.
B. At its option, Kaz will repair or replace this product if it is found
to be defective in material or workmanship.
C. This warranty does not cover damage resulting from any unauthorized
attempts to repair or from any use not in accordance with the instruction
manual.
D. This warranty does not cover the filters, pre-filters, UV bulbs or
other accessories (if included) except for material or workmanship defects.
Call us toll-free at 1-800-477-0457 or
e-mail:
ConsumerRelations@HelenofTroy.com
Please be sure to specify a model number.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST
OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF
PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF, DOING SO MAY VOID
YOUR WARRANTY AND CAUSE DAMAGE TO THE PRODUCT OR PERSONAL INJURY.
© 2021 All rights reserved.
Kaz USA, Inc., a Helen of Troy Company
400 Donald Lynch Blvd., Suite 300, Marlborough, MA 01752
In Canada: Distributed by Kaz Canada, Inc., a Helen of Troy Company
6700 Century Avenue, Suite 210, Mississauga, Ontario L5N 6A4
www.VicksHumidifiers.com
Certain trademarks used under license from The Procter & Gamble Company or its
affiliates.
Protec® and Sleepy Time™ are trademarks of Helen of Troy Limited.
Aquastat is a registered trademark of K2 Concepts, Inc., Atlanta, GA.
Made and printed in China.
**For Responsible recycling, please visit:
www.RecycleNation.com
A005730R0
18MAR21**