VICKS VWC775 Series Dual Comfort Cool + Warm Mist Humidifier Owner’s Manual

June 6, 2024
Vicks

VICKS VWC775 Series Dual Comfort Cool + Warm Mist Humidifier

If you have any questions about the operation of this product, please call us toll-free at 1-800-827-6712, e-mail us at [email protected], or visit our website at: www.VicksHumidifiers.com

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HUMIDIFIER
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

  1. The humidifier should ALWAYS be placed on a firm, flat, waterproof surface at least four feet (1.2m) away from bedside, 12 inches
    (30cm) from the wall. KEEP OUT OF REACH OF CHILDREN AND PETS. This product produces hot steam and should be placed in an area not accessible to children or pets, with the power cord out of reach.

  2. Be sure the humidifier is in a stable position and the power cord is away from heated surfaces and out of the way to prevent the humidifier from being overturned.

  3. DO NOT leave the humidifier unattended in a closed room, doing so may cause personal injury or property damage. If room becomes saturated, open the door and turn the humidifier off or down.

  4. Before using the humidifier, extend the cord and inspect for any signs of damage. DO NOT use the unit if the cord has been damaged. DO NOT operate with power cord coiled or with twist tie in place.

  5. The humidifier has a polarized plug (one blade is wider than the other) as a safety feature. This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.

  6. CAUTION: To avoid fire or electric shock hazard, plug the humidifier directly into a 120V AC electrical outlet. To avoid risk of fire, electric shock, or personal injury, NEVER use an extension cord or power strip.

  7. The humidifier should ALWAYS be unplugged and emptied when not in operation or while being cleaned. Turn off and unplug humidifier before moving. DO NOT move or tilt humidifier while it is in operation. Plug and unplug unit with dry hands. NEVER pull by cord.

  8. DO NOT operate the humidifier without water. Turn off and unplug unit when tank is empty and the reset light is on.

  9. Humidifier requires regular cleaning. Refer to and follow cleaning instructions.

  10. DO NOT operate outdoors; this humidifier is intended for indoor residential use only.

  11. DO NOT place in direct sunlight, high temperature areas or near computers or sensitive electronic equipment.

  12. DO NOT cover or insert objects into any openings on the unit. DO NOT block intake or output vents.

  13. DO NOT touch the Nebulizer or Heating Element while humidifier is plugged in or still hot, as burns could result

  14. DO NOT attempt to repair or adjust any electrical or mechanical functions on this humidifier. Doing so will void your warranty.

  15. DO NOT add any essential oils or medications (e.g. Vicks VapoSteam®) into the Water Reservoir or Water Tank. Doing so could damage the humidifier and void the warranty.

  16. DO NOT touch the steam vapor. Steam can cause burns.

  17. DO NOT operate without the Mist Chimney and Mist Chimney Cover in place.

  18. For Residential Use Only.

  19. SAVE THESE INSTRUCTIONS

GETTING TO KNOW YOUR COOL + WARM MIST HUMIDIFIER

How it Works

How it Works

How it Works 1

How it Works 2

Components

  1. Tank Handle
  2. Water Tank
  3. Mist Outlet
  4. Mist Chimney Cover
  5. Mist Chimney
  6. Medicine Cup
  7. Cleaning Brush
  8. Base
  9. Control Panel
  10. Tank Cap
  11. Gasket
  12. Plunger
  13. Float
  14. Water Reservoir
  15. Nebulizer
  16. Water Path
  17. Boiling Chamber
  18. Heating Element
  19. Fan Outlet
  20. Chimney Latch

SETTING UP YOUR HUMIDIFIER

Unpack the Humidifier
Keep this Owner’s Manual for reference.
Remove packaging materials. Remove twist tie from power cord and extend power cord to full length.
Ensure proper assembly. Remove Tape and be sure components are in place.
Place on a firm, level, water resistant surface a minimum of 12” (30cm) from any walls. Mist should be directed away from any walls, bedding and furniture.

WARNING: KEEP OUT OF REACH OF CHILDREN. THIS PRODUCT PRODUCES HOT STEAM AND SHOULD BE PLACED IN AN AREA NOT ACCESSIBLE TO CHILDREN OR PETS, WITH THE POWER CORD OUT OF REACH.

FILLING / REFILLING

NOTE: Tank should be carried using two hands; one hand on the Tank Handle and the other supporting the bottom of the tank.
Kaz USA, Inc. will not accept responsibility for property damage caused by water spillage.
This humidifier holds 1.2 gallons (4.5L) of water (tank and reservoir combined).

Filling

Filling

  1. Remove Water Tank and turn upside down. Remove Tank Cap by turning counter clockwise (left). Fill Tank with cool water. DO NOT fill with warm or hot water.
  2. Replace Tank Cap by turning clockwise (right), aligning arrow to lock symbol. Be sure Gasket is in place.
  3. Place Tank on Base. Water will drain from the Tank into the Reservoir when the Plunger is engaged.

USING YOUR HUMIDIFIER

VWC775 Manual Control Panel

  1. Power: Press Power Button to turn on.
    Unit defaults to cool mist, high output setting.

  2. Mist Temperature: Press Cool or Warm selectors to toggle between cool and warm mist output settings.
    The Mist Output LEDs and light around the Mist Temperature buttons will be blue when unit is in cool mist mode and orange when in warm mist mode.
    NOTE: Cool mist is immediate but please allow up to 5 minutes or more for water to boil to produce warm mist. It is normal to hear the sound of the water boiling occasionally as more water drains into the Boiling Chamber.

  3. Mist Output Level: Press the desired Mist Temperature icon ( ) to cycle through low, medium and high mist output settings. One light for low, two lights for medium and three lights for high.
    The higher the output setting, the more moisture enters the air.
    The lower the output setting, the longer the run time before needing to be refilled.

  4. Reset: The Reset Light has several functions. See next section for details.

USING YOUR HUMIDIFIER

RESETTING YOUR HUMIDIFIER

Situation Reset Light How to Reset
Water Tank Removed Illuminates Orange Replace Tank on Base (must

contain water)
Tank Empty| Illuminates Orange| Fill Tank and Replace on Base
Mineral Buildup on Heating Element| Blinks Red| See Cleaning Instructions

2-WAY MIST OUTLET
This humidifier features a 2-Way Mist Outlet that allows you to direct mist in in two directions. Positioning both openings in the same direction results in a strong mist plume into the room. Separating the mist outlets allows for pointing the mist in two directions for wider distribution.

2-WAY MIST OUTLET

USING THE MEDICINE CUP

This humidifier features a Medicine Cup that can be used with your favorite essential oil or liquid inhalant (like Vicks VapoSteam) for added enjoyment. The cup is heated to help evaporate the oil. This is not a diffuser – the oil does not come in contact with the water but is passively evaporated into the air. Essential oil and inhalant are not included.

  1. Turn off the humidifier.

  2. Add Vicks VapoSteam or essential oil to the Medicine Cup, turn on the humidifier.
    WARNING: DO NOT ADD ESSENTIAL OILS, LIQUID INHALANTS OR ANY ADDITIVES TO THE WATER. DOING SO CAN DAMAGE THE HUMIDIFIER AND VOID THE WARRANTY.

  3. To clean the Medicine Cup wait 5 minutes after turning the unit off. Then gently wipe residue from the cup with a soft cloth.

USING THE MEDICINE CUP

USING VICKS VAPOPADS
Your humidifier can be used with Vicks VapoPads to provide up to 8 hours of soothing vapors. One free sample of the menthol VapoPad is included with your humidifier. To use your unit with Vicks VapoPads:

  1. Open VapoPad Door.
  2. Open VapoPad by tearing notch on pad bag. DO NOT touch pad with hands. If pad is touched DO NOT rub face or eyes as it may cause irritation.
  3. Insert Vicks VapoPad with angled end facing towards the product. Up to two VapoPads can be inserted. Close door.
  4. After 8 hours, discard scent pad.
    To continue using scent pads, repeat steps 1-4.

USING VICKS VAPOPADS

VAPOPAD RECOMMENDED USAGE:

  • Not recommended for infants under 10 lbs (4.5 kg).
  • For children between 10-22 lbs (4.5-10 kg ) do not use more than 2 pads in a 24 hr period. Sample VapoPad ingredients: Eucalyptus Oil, Menthol, Glycol, Cedar Leaf Oil & Others.
    NOTE: ALWAYS reference VapoPad packaging for recommended usage instructions and warnings.

HARD WATER AND YOUR HUMIDIFIER
High mineral content in your water, also known as hard water, may cause a white mineral residue to accumulate on surfaces in the room near the humidifier. This mineral residue is commonly referred to as white dust. The higher the mineral content (hardness) of your water, the greater the potential that an ultrasonic humidifier may produce white dust.
With warm mist humidifiers the minerals can cling to the heating element which can prevent it from running efficiently. It is important to clean the heating element regularly.
White dust is not a result of a defect or flaw in the humidifier. It is a result of the amount of minerals suspended in the water you are using. Tap water can be diluted with distilled water to reduce white dust.

CLEANING YOUR HUMIDIFIER

To keep your humidifier running efficiently, clean it regularly. Weekly cleaning is recommended. All maintenance should be done in the kitchen or bathroom on a water resistant surface near a faucet.
To properly clean your humidifier, we recommend the separate processes of Scale Removal and Disinfecting.
These two processes must be performed separately.

Before Cleaning
If the humidifier has recently been in use on the warm setting, wait at least 20 minutes for unit to cool before beginning the cleaning process.

  1. Turn off and unplug humidifier.
    Never clean the humidifier when it is running.

  2. Remove Water Tank and empty completely. Remove any accessories from the water tank.

  3. Ensure Chimney is removed (See Disassembly below), then pour solution from the Base into the sink. Be sure to pour out of the side of the Base, as indicated by an arrow, to avoid leaking into the Control Panel.

  4. Replace Chimney and Chimney Cover before beginning the cleaning process.

CLEANING YOUR HUMIDIFIER 1

Disassembly

  1. Mist Chimney Cover – a) slide blue latch and b) remove.
  2. Mist Chimney – grasp Chimney and pull straight up.
  3. Mist Outlet – pull out of Mist Chimney Cover (optional).

CLEANING YOUR HUMIDIFIER 2

Reassembly

  1. Replace Mist Chimney.
  2. If removed, replace Mist Outlet on top of Mist Chimney Cover.
  3. Slide the blue latch a) and place the Mist Chimney Cover in place b); secure the latch.

CLEANING YOUR HUMIDIFIER 3

Scale Removal (Mineral Build-up)
Follow steps 1-4 in Before Cleaning section, then follow the additional steps below.

CLEANING YOUR HUMIDIFIER 4

  1. Pour 2.5 cups (.6 liters) of undiluted distilled white vinegar into the Water Tank.

  2. Replace Tank Cap and swish vinegar in Tank to coat the inside of the Water Tank.

  3. Place Tank on Base, allowing vinegar to drain into the Water Reservoir. The vinegar will loosen mineral buildup on the Nebulizer, Heating Element and Float, and in the bottom of the Tank. Soak for 20 minutes.

  4. Remove Water Tank and empty vinegar into sink.CLEANING YOUR HUMIDIFIER 5

  5. Remove Mist Chimney Cover, Mist Chimney and Mist Outlet to access Reservoir area (see Disassembly instructions). Use Cleaning Brush to loosen mineral buildup in corners of Reservoir, Water Path and Boiling Chamber.

  6. Gently wipe Nebulizer, Heating Element and Reservoir area with a soft cloth or small soft brush (avoids damage) to remove loosened minerals.
    NOTE: Nebulizer is fragile. DO NOT apply extreme pressure.

  7. Ensure Chimney is removed, then pour vinegar from the Base into the sink. Be sure to pour from the side as indicated by an arrow to avoid leaking into the Control Panel. Rinse the Tank and Reservoir with clean water until the smell of vinegar is gone.
    CAUTION: DO NOT submerge Base in water. Doing so will damage the humidifier and void the warranty.

  8. Reassemble Mist Chimney, Mist Chimney Cover, and Mist Outlet (see Reassembly instructions).

Disinfecting
Before starting the disinfecting process, follow Steps 1-4 in the Before Cleaning section. NOTE: Bleach may stain clothes. It is recommended to wear rubber gloves during this process to protect your hands.

  1. Add 1 teaspoon of bleach to 1 gallon (3.8L) of water and add to Water Tank.
  2. Replace Tank Cap and swish bleach solution in Tank to coat the inside of the Water Tank.
  3. Place Tank on Base, allowing solution to drain into the Water Reservoir. Soak for 20 minutes.
  4. Remove Water Tank and empty solution into sink.
  5. Ensure Chimney is removed, then pour solution from the Base into the sink. Be sure to pour out of the side of the Base, as indicated by an arrow, to avoid leaking into the Control Panel.
  6. Rinse Tank and Reservoir area with clean water until the smell of bleach is gone.
    CAUTION: DO NOT submerge Base in water. Doing so will damage the humidifier and void the warranty.

CLEANING YOUR HUMIDIFIER 6

CLEANING YOUR HUMIDIFIER 7

END OF SEASON CARE AND STORAGE
Follow the cleaning instructions when the humidifier will not be used for at least one week, or at the end of the season. At the end of the season, remove any accessories from the humidifier.
Dry the humidifier completely before storing. DO NOT store with water inside the Water Tank or Reservoir. Pack unit in original carton and store in a cool, dry location.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE SOLUTION
Power is on but no mist appears Water Tank is empty

Auto shut off has been engaged inadvertently

| Fill Tank with water

Remove the Tank and adjust the Float

Reset Light Illuminated (orange)| Water Tank is empty Water Tank is not secured on Base| Fill Tank with Water

Make sure there are no obstructions and position tank to fit flush with the rest of the unit

Reset Light Blinking (red)| Mineral Deposits on Heating Element| See Cleaning Instructions
Unit is leaking| Cap is not on tight Cracked tank| Ensure cap is secured in the lock position

Inspect for cracks; contact Consumer Relations for replacement

Sounds different on warm mist setting than cool mist setting| The sound may increase on warm mist setting as the heating element warms up to boil water| Wait up to 5 minutes for water to boil then sound should decrease; sound will be slightly higher on warm mist setting
Condensation forms around humidifier or on windows| Mist Intensity is set too high for room size or pre-existing humidity level| Decrease mist output to low setting or open door to the room
White dust settling on surfaces in room| Mineral content in hard water| Dilute tap water with distilled water to minimize white dust

NOTE: Failure to keep this unit clean from mineral deposits normally contained in any water supply will affect the efficiency of operation of this unit. Customer failure to follow these instructions may void the warranty.

CONSUMER RELATIONS
We are here to help. Call us toll-free at: 1-800-827-6712
E-mail: [email protected]
Or visit our website at: www.VicksHumidifiers.com
Please be sure to specify Model number VWC775.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY. DO NOT RETURN TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE ELECTRICAL HOUSING YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR PERSONAL INJURY.

SPECIFICATIONS

Electrical rating: 120V, 60Hz., 180W
Capacity: 1.2 gallons (4.5 L)

2 YEAR LIMITED WARRANTY

You should first read all instructions before attempting to use this product.

  1. This 2 year limited warranty applies to repair or replacement of product found to be defective in
    material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.

  2. At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship.

  3. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.

  4. This warranty does not cover the filters, pre-filters, UV bulbs or other accessories (if included) except for material or workmanship defects.

© 2021 All rights reserved.
Manufactured by: Kaz USA, Inc., a Helen of Troy Company 400 Donald Lynch Blvd., Suite 300, Marlborough, MA 01752
Imported by: Kaz Canada, Inc., a Helen of Troy Company 6700 Century Avenue, Suite 210, Mississauga, Ontario L5N 6A4
Certain trademarks used under license from The Procter & Gamble Company or its affiliates.
To contact us call 1-800-VAPOR-1-2 (1-800-827-6712) or visit our website at www.VicksHumidifiers.com
Made in China
For Responsible recycling, please visit: www.RecycleNation.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Vicks User Manuals

Related Manuals