SR KWL-SG -US Parameters
- Net weight: 3 kg
- Dimension: * mm
- Capacity: Wh, . V
- Wi-Fi supported
Output
AC output x :
- Maximum load
- USB-A (x )
- USB-A quick charge x2
- USB-C (x )
- Car charger DC5521 output x2
- Car charge and DC share power
AC output (x ): – V~ ( / Hz), A – W
AC output (x ): – V~ ( / Hz), A – W
AC output (bypass mode): – V~ ( / Hz) A – W
W, bypass mode W
V . A (constant voltage), W Max./output V A V A V . A (constant voltage), W
Max./output 5/9/12/ V A V A (constant voltage), W Max./output
. V A, W Max.
.V A W Max.
Input
AC input power: W Max., A – V~ Hz/ Hz
AC input voltage: – V~ Hz/ Hz
PV charge: V/ V battery supported, A by default
Battery
- Cell Type: lithium iron phosphate battery (LiFePO)
- Life cycle: remaining capacity still over % after , cycles
- Protection type: over-temperature protection, low-temperature protection, over-discharge protection, over-charge protection, over-load protection, short-circuit protection, over-current protection
- Operating temperature: ~
- Optimal operating temperature: ~
- Discharge ambient temperature: -~
- Charge ambient temperature: ~
- Storage ambient temperature: – ~ ( ~ preferred)
- *Whether the product can be charged or discharged is subject to the actual battery pack temperature.
Others
Battery Expansion: Wh, support expansion battery packs at most, separate
selling.
Product Usage Instructions
Safety Guidelines
Utilisation
Jeter
Guideline for Users – Product Overview
The product includes the following components:
- LCD screen
- AC charging
- PV charging
- Car charging
- Battery expansion
- APP
- UPS function
Guideline for Users – LCD Screen
The LCD screen displays various information such as battery pack status, remaining charge/discharge time, fan status, quick charge/car charge status, and error codes.
Use
To turn on the device, press the main power switch. The screen will light
up and the main power indicator will enter the breathing light mode.
To turn off the device, long press the main power switch.
Note: For more detailed information and error messages, refer to clause in the user manual.
SRO3KWL-SG1-US parameters
Guideline for users
Product overview
LCD screen
Battery capacity: When SR03KWL-SG1-US is being charged, SOC icon will flicker.
Wi-Fi connection status: The flickering icon indicates that SR03KWL-SG1-US is
ready for pairing. The icon will
keep flickering if a mobile phone and SR03KWL-SG1-US are connected by hotspot.
After network connection succeeds, the icon will always be on. If connection
fails, the icon will be off.
Please refer to clause 5 for more details regarding error message.
Use
On and off
- Press the main power switch to turn on the device, then the screen will be lit and the main power indicator will enter the breathing light mode.
- If no operation is performed to SR03KWL-SG1-US for 5 minutes, SR03KWL-SG1-US will enter hibernation state and the LCD will automatically turn off. When there is load change or operation to SR03KWL-SG1-US, the LCD screen will be automatically lit. Press the main power switch to turn on or turn off the LCD.
- Press and hold the main power switch will turn off SR03KWL-SG1-US.
- The default standby time is 2 hours. If other output power switches are not turned on and not any loads are connected, SR03KWL-SG1-US will automatically shut down after 2 hours. Standby time can be set on the APP.
- USB output is enabled by default after the main power switch is turned on.
- After the main power switch is turned on, press the 12V DC output power switch to enable the DC output port.
- Press the 12V DC output power switch again to turn it off.
- When the 12V DC output power switch is turned on,SR03KWL-SG1-US does not shut down automatically.
- After the main power is on, press the AC output power switch to enable the AC output port. Press the AC output power switch again to turn it off.
- The default standby time of the AC 1 output is 1 hour. After 1 hour without any loads, the AC output power switch will be automatically off.
- When the AC output is not in use, turn it off to save power consumption.
AC charging
Quick charging technology is designed for AC charging. You can control the charging power via the AC charging speed switch. The slow charge mode is on by default when SR03KWL-SG1-US is turned on, and can be switched to quick charge mode by the button. Quick and slow charging mode switching can also be set by APP. If the current is continuously higher than 20A, the charging input port will start the self-protection function, and the charging overload protection switch will automatically trip. Press the charge overload protection switch to restore charging after confirming no fault.
Quick charge and slow charge can be switched by the button.
The charging power range can be adjusted by APP.
Please use the standard AC charging Cable for fast charging. AC Charging Cable should directly plug into 15A (or above) wall-mounted socket. We take no responsibilities for any damage caused by using unofficial AC charging cable, and other failures to follow instructions.
PV charging
Users can use solar panels to charge SR03KWL-SG1-US as shown in the picture.
Dual solar panels supported.
Solar charging cable (DC7909)
Please follow the user manual to connect the solar panels.
Before connecting the solar panel, check whether its output voltage is within
SR03KWL-SG1-US specifications to avoid damage to SR03KWL-SG1-US.
Car charging
SR03KWL-SG1-US can be charged by a car charging port. It should be charged
after the car starts, so as to avoid the car battery loss and failure to
start. At the same time, ensure good connection between the car charging port
and cigarette lighter. We take no responsibilities for any loss caused by
improper operation.
Battery expansion
SR03KWL-SG1-US supports connection with 6 expansion battery packs at the same
time for larger capacity.
Please refer to the user manual of battery pack for details.
Notes,
- Before connecting the battery pack, please make sure both SR03KWL-SG1-US and battery pack are off.
- After the battery pack is connected, check if battery icon is shown in the displays of both SR03KWL-SG1-US and battery pack.
- While in charging, please do not connect or remove the battery pack. If connection or need to connect or remove it, turn off SR03KWL-SG1-US prior to operation.
- Please do not touch the metal terminals. If there is foreign matter on the metal terminals, clean it with dry cloth gently and carefully.
Scenarios of battery pack connection
Scenario 1
- Turn off the power station and expansion battery pack.
- Plug one end of the cable to expansion port of power station, the other end to Power Output of battery pack.
- After parallelization, press power button of power station to enable the power station and battery pack to show current capacity. The power station shows the paralleled quantity, and capacity is expanded.
- After parallelization, connect ports of the power station for charging or discharging (refer to clause 3.3, 3.4, 3.5 and 3.6).
Remark: There are + and ‒ symbols on battery packs and cables in case of reverse polarities.
Scenario 2
- Turn off the power station and expansion battery packs.
- Plug one end of cable #1 to expansion port of power station, the other end to Power Output of battery pack #1. Plug one end of cable #2 to Power Input of battery pack #1, the other end to Power Output of battery pack #2. Plug one end of cable #3 to Power Input of battery pack #2, the other end to Power Output of battery pack #3. 6 battery packs can be parallelized at most.
- After parallelization, press power button of the power station to enable the power station and battery packs to show current capacity. The power station shows the paralleled quantity, and capacity is expanded.
- After parallelization, connect ports of the power station for charging or discharging (refer to clause 3.3, 3.4, 3.5 and 3.6).
Remark: There are + and – symbols on battery packs and cables in case of reverse polarities.
APP
You can control and view information and data about this product by App.
UPS function
This product supports the UPS function. When you connect the electrical
appliance with SR03KWL-SG1-US by AC cable, the output enables the appliance to
work. In such case, power is from grid instead of battery. When power grid is
off, the power station can switch to battery-supplying mode within 14mS. Such
function is unprofessional UPS, which does not support switch in OmS, so do
not connect it to equipment with strict UPS requirement, such as data server
and workstation or please confirm compatibility after tests, and suggest only
use one device instead of multiple devices at the same time so as not to cause
overload to the power station.
We shall not be liable for abnormal work or data loss arising from operation
not following this user manual.
FAQs (Frequently Asked Questions)
-
What kind of battery is used?
Lithium iron phosphate battery (LiFePO,). -
What equipment can be connected to the AC output ports?
The AC output has high rating power and maximum power, which enables it to supply power to most household appliances. Suggest check the equipment power prior to connecting and make sure power of all equipment lower than rated power. -
How to know the supply time?
Time shows in the LCD, which can be referred to for estimation for equipment with stable power consumption. -
How to know it is charging?
When in charge, the LCD shows remaining charging time. The SOC flickers, and input power is shown. -
How to clean the unit?
Clean the unit with a dry, soft and clean cloth or tissue. -
How to store the unit?
Turn it off, and keep it in a dry and ventilated place. Do not expose it close to water. For long-term storage, suggest discharge to 0% and charge to 100% every 3 months to extend the service life. -
Can it be taken on board?
No.
Error messages & solutions
If there is a warning occurs during the use of this product, and the warning icon still does not disappear after restarting the device, please stop using it immediately (do not try to charge or discharge).
If none solve problem please contact the custom consultation.
What’s in the box
Disclaimer
Before using the power station SR03KWL-SG1-US, please read this user manual to
ensure understanding and proper use. After reading the user manual, please
keep it well for future reference. Improper operation may cause serious injury
to yourself or others, or result in product damage and property loss. Once
using SR03KWL-SG1-US, you are deemed to have understood and accepted all terms
and contents herein. Users promise to be responsible for their actions and all
consequences arising therefrom. We shall not be liable for any loss arising
from user’s not following this user manual.
In compliance with laws and regulations, the company reserves the right of
final interpretation of this document and all related documents of this
product. Subject to update, revision or termination without prior notice,
please visit the official website for the latest product information.
ISED Statement
This device contains licence-exempt transmitter (s)/receiver(s) that comply
with?Innovation, Science and Economic
Development?Canada’s licence-exempt RSS(s). Operation is subject to the
following two conditions:
- This device may not cause interference.
- This device must accept any interterence, including interterence that may cause undesired operation of the device.
The device has been evaluated to meet general RF exposure requirement. The devicecan be used in portable exposure conction without restrictions
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
a for a class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates uses and can radiate radio frequence energy and,if
not installed and used in accordance with the instructions,may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.if this equipmemt
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user S encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an autlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. The
devicecan be used in portable exposure condition without restriction.
This equipment should be installed and operated with a minumum distance of 20
cm between the radiator and your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>