Regulus CSE TV ZV G 1F Pump Station User Manual

June 13, 2024
Regulus

Regulus CSE TV ZV G 1F Pump Station

Product Information

  • Product Name: CSE TV ZV G 1F Pump Station
  • Manufacturer: REGULUS spol. s r.o.
  • Website: www.regulus.eu
  • Installation and Operation Manual: EN Manual

Introduction

This pump station is intended to ensure circulation in DHW distribution piping in buildings or to ensure hot water recirculation in DHW heating systems.

Description of the pump station

It consists of a UPM3 DHW 15-70 pump incl. power cable, insulation, check valve, two ball valves and thermometer.

Main features

Application| DHW circuits – recirculation or heating in a heat exchanger
Description| consists of UPM3 DHW 15-70 pump, insulation, valve, two ball valves and thermometer
Working fluid| water, drinking water
Installation| to the piping, min. distance of the pipe axis from a wall is 100 mm
Code| 15181
Data of CSE TV ZV G 1F Pump Station

Fluid working temperature| 2 – 95 °C
Max. working pressure| 10 bar
Min. working pressure| 0.5 bar
Ambient temperature| 5 – 40 °C
Max. rel. humidity| 80 %, non condensing
Power supply| 230 V, 50 Hz
Insulation material| EPP RG 60 g/l
Overall dimensions| 325 x 140 x 150 mm
Total weight| 2.0 kg
Connections| 2x G 1″ F

Direction of Flow through the Pump Station

Regulus-CSE-TV-ZV-G-1F-Pump-Station-FIG-1

UPM3 DHW 15-70 Pump, 130 mm

Design
A wet-running circulation pump, G 1“ M connection.

Electrical data

Power supply| 230 V, 50 Hz
Power input (min./max.)| 2/52 W
Current (min./max.)| 0.04/0.52 A
IP rating| IP44
Max. speed| 5766 rpm
Weighted average power| ≤ 23 W
Energy Efficiency Index| ≤ 0.20 by EN 16 297/3
Motor protection| not needed

Pump control
The circulation pump can be controlled without a PWM signal by selecting the pump performance curve or using an external PWM control signal (profile for use in heating systems). A PWM pump control cable with connector is not included. It can be purchased as an optional accessory (code 16792), cable length 2 m.
The maximum operating curve of the pump can be defined.

  •  with no PWM signal the pump runs at max. speed following the selected curve
  •  with PWM signal the pump speed changes with the signal value up to the maximum of the selected curve

Performance curvesRegulus-CSE-TV-ZV-G-1F-Pump-Station-
FIG-3

Performance display

The LED numbering is further omitted for better clarity.Regulus-CSE-TV-ZV-G
-1F-Pump-Station-FIG-5

WARNING: LEDs may be mirrored, depending on the specific pump type.

GREEN LED FLASHING FREQUENCY GREEN LED FLASHING FREQUENCY
1 flash per second NO
12 flashes per second YES

When switched on, the pump runs at factory settings or the last setting. The display shows the current pump performance.

Setting Selection for UPM3
To select your desired setting, press the button repeatedly until you find the setting you need (see the figure above). If you pass the desired setting, you have to go one more round until it appears again.
Error DisplayRegulus-CSE-TV-ZV-G-1F-Pump-Station-
FIG-6

Prohibited positions

Permissible positionsRegulus-CSE-TV-ZV-G-1F-Pump-Station-
FIG-8

Pump WiringRegulus-CSE-TV-ZV-G-1F-Pump-Station-
FIG-9

  • socket for power supply (A)
  • and signal transmission (B)
  • power supply (A)
  • and signal (B) connectors
  • N (blue)
  • L (brown)
  • PE (yellow-green)
  • PWM GDN (blue)
  • iPWM out (black)
  • PWM in (brown)
  • connector (B) with 2m cable is not
  • included in supply; it can be purchased as
  • optional accessory, code 16792