Regulus CSE TV ZV G 1F Pump Station
Product Information
- Product Name: CSE TV ZV G 1F Pump Station
- Manufacturer: REGULUS spol. s r.o.
- Website: www.regulus.eu
- Installation and Operation Manual: EN Manual
Introduction
This pump station is intended to ensure circulation in DHW distribution piping in buildings or to ensure hot water recirculation in DHW heating systems.
Description of the pump station
It consists of a UPM3 DHW 15-70 pump incl. power cable, insulation, check valve, two ball valves and thermometer.
Main features
Application| DHW circuits – recirculation or heating in a heat exchanger
Description| consists of UPM3 DHW 15-70 pump, insulation, valve, two ball
valves and thermometer
Working fluid| water, drinking water
Installation| to the piping, min. distance of the pipe axis from a wall is 100
mm
Code| 15181
Data of CSE TV ZV G 1F Pump Station
Fluid working temperature| 2 – 95 °C
Max. working pressure| 10 bar
Min. working pressure| 0.5 bar
Ambient temperature| 5 – 40 °C
Max. rel. humidity| 80 %, non condensing
Power supply| 230 V, 50 Hz
Insulation material| EPP RG 60 g/l
Overall dimensions| 325 x 140 x 150 mm
Total weight| 2.0 kg
Connections| 2x G 1″ F
Direction of Flow through the Pump Station
UPM3 DHW 15-70 Pump, 130 mm
Design
A wet-running circulation pump, G 1“ M connection.
Electrical data
Power supply| 230 V, 50 Hz
Power input (min./max.)| 2/52 W
Current (min./max.)| 0.04/0.52 A
IP rating| IP44
Max. speed| 5766 rpm
Weighted average power| ≤ 23 W
Energy Efficiency Index| ≤ 0.20 by EN 16 297/3
Motor protection| not needed
Pump control
The circulation pump can be controlled without a PWM signal by selecting the
pump performance curve or using an external PWM control signal (profile for
use in heating systems). A PWM pump control cable with connector is not
included. It can be purchased as an optional accessory (code 16792), cable
length 2 m.
The maximum operating curve of the pump can be defined.
- with no PWM signal the pump runs at max. speed following the selected curve
- with PWM signal the pump speed changes with the signal value up to the maximum of the selected curve
Performance curves
Performance display
The LED numbering is further omitted for better clarity.
WARNING: LEDs may be mirrored, depending on the specific pump type.
GREEN LED FLASHING FREQUENCY | GREEN LED FLASHING FREQUENCY |
---|---|
1 flash per second | NO |
12 flashes per second | YES |
When switched on, the pump runs at factory settings or the last setting. The display shows the current pump performance.
Setting Selection for UPM3
To select your desired setting, press the button repeatedly until you find
the setting you need (see the figure above). If you pass the desired setting,
you have to go one more round until it appears again.
Error Display
Prohibited positions
Permissible positions
Pump Wiring
- socket for power supply (A)
- and signal transmission (B)
- power supply (A)
- and signal (B) connectors
- N (blue)
- L (brown)
- PE (yellow-green)
- PWM GDN (blue)
- iPWM out (black)
- PWM in (brown)
- connector (B) with 2m cable is not
- included in supply; it can be purchased as
- optional accessory, code 16792